C01.14 - Non-hydraulic Cements
Non-hydraulic Cements
General Information
SIGNIFICANCE AND USE
4.1 These test methods are used to develop data for comparison with the requirements of Test Methods C1910/C1910M or other specifications for cements that require carbonation curing. These test methods are based on standardized testing in the laboratory and are not intended to simulate job conditions. All tests are performed with mortar and therefore, the results may not provide a direct correlation of how the tested cementitious material will perform in concrete.
4.2 Compressive Strength—The test for compressive strength is used to determine whether the cement tested will develop a minimum level of strength when carbonated under laboratory conditions.
4.3 Chemically Bound Carbon Dioxide—Determined using mortar cube specimens prepared for determining compressive strength, the test for chemically bound carbon dioxide is used as an estimate of the mass of carbon dioxide bound during the carbonation curing process and is expressed as a percent of the mass of cement in the test mixture. The actual amount of carbon dioxide bound in a manufactured product is affected by the carbonation process and the cement used, and the physical characteristics of the manufactured product.
SCOPE
1.1 These test methods cover procedures for testing cements that require carbonation curing and are intended for use in concrete.
1.2 The procedures are organized in the following sections:
Casting and Carbonation Curing Test Specimens
Section 8
Compressive Strength
Section 9
Bound Carbon Dioxide
Section 10
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this standard. Some values only have SI units because the inch-pound equivalents are not used in standard.
1.4 If required results obtained from another standard are not reported in the same system of units as used by this standard, it is permitted to convert those results using the conversion factors found in the SI Quick Reference Guide, Annex A in Form and Style for ASTM Standards, www.astm.org/COMMIT/Blue_Book.pdf.
1.5 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Warning—Common cementitious mixtures are caustic and may cause burns to skin and tissue upon prolonged exposure.2
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SCOPE
1.1 This specification covers cements that require controlled exposure to carbon dioxide to achieve strength, referred to as carbonation curing. These cements are for use in concrete that does not contain steel reinforcement. There are no restrictions on the constituents of the cement. The producer is required to demonstrate that carbon dioxide is chemically bound by the cement.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. Values are stated in only SI units when inch-pound units are not used in practice.
1.3 If required results obtained from another standard are not reported in the same system of units as used by this standard, it is permitted to convert those results using the conversion factors found in the SI Quick Reference Guide, Annex A in Form and Style for ASTM Standards, www.astm.org/COMMIT/Blue_Book.pdf.
1.4 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) are not requirements of the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method provides a means of determining the compressive strength of alkali-activated cementitious material mortars and results may be used to determine compliance with specifications.
SCOPE
1.1 This test method covers determination of the compressive strength of alkali activated cementitious material mortars, using 2-in. [50 mm] cube specimens.
1.2 This test method references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the test method.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. If required results obtained from another standard are not reported in the same system of units as used by this standard, it is permitted to convert those results using the conversion factors found in the SI Quick Reference Guide.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2)
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
Frequently Asked Questions
C01.14 is a Technical Committee within ASTM International. It is named "Non-hydraulic Cements". This committee has published 3 standards.
C01.14 develops ASTM standards in the area of Information technology. Currently, there are 3 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.