Specifications for particular types of winding wires -- Part 26: Polyamide-imide enamelled round copper wire, class 200

IEC 60317-26:1990 specifies the requirements of enamelled round copper winding wire of class 200 with a sole coating based on polamide-imide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is:
Grade 1: 0,071 mm up to and including 1,600 mm;
Grade 2: 0,071 mm up to and including 0,500 mm.
The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1. This second edition of IEC 60317-26 replaces the first edition issued in 1988.

Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten -- Teil 26: Runddrähte aus Kupfer, lackisoliert mit Polyamidimid, Klasse 200

Spécifications pour types particuliers de fils de bobinage -- Partie 26: Fil de section circulaire en cuivre émaillé avec polyamide-imide, classe 200

IEC 60317-26:1990 concerne les fils de bobinage de section circulaire en cuivre émaillé de classe 200 avec un revêtement unique à base de résine polyamideimide. Une classe 200 est une classe thermique qui exige un indice de température minimal de 200 et une température de choc thermique d'au moins 220 °C. La température en degrés Celsius correspondant à l'indice de température n'est pas nécessairement celle à laquelle il est recommandé d'utiliser le fil et cela dépendra de beaucoup de facteurs, y compris du type d'équipement considéré. La gamme des diamètres nominaux des conducteurs couverte par la présente norme est:
- Grade 1: 0,071 mm jusqu'à et y compris 1,600 mm;
- Grade 2: 0,071 mm jusqu'à et y compris 0,500 mm.
Les diamètres nominaux des conducteurs sont spécifiés dans l'article 4 de IEC 60317-0-1. Cette deuxième édition de IEC 60317-26 remplace la première édition parue en 1988.

Specifications for particular types of winding wires - Part 26: Polyamide-imide enamelled round copper wire, class 200

Ta mednarodni standard določa zahteve za emajliran bakren okrogel vodnik razreda 200 z enojnim premazom, osnovanim na poliamidimidni smoli. Razred 200 je toplotni razred, ki zahteva minimalni temperaturni indeks 200 °C in temperaturo toplotnega šoka najmanj 220 °C. Temperatura v stopinjah Celzija, ki ustreza temperaturnemu indeksu, ni nujno ta, pri kateri se priporoča delovanje vodnika, saj je le-to odvisno od več dejavnikov, vključno s tipi uporabljene opreme. Razpon nominalnih premerov prevodnikov, ki jih zajema ta standard, je:
stopnja 1: 0,071 mm do vključno 1,600 mm;
stopnja 2: 0,071 mm do vključno 0,500 mm.
Nominalni premeri prevodnikov so določeni v klavzuli 4 IEC 317-0-1.

General Information

Status
Withdrawn
Publication Date
31-Aug-2001
Withdrawal Date
12-Apr-2023
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
12-Apr-2023
Due Date
05-May-2023
Completion Date
13-Apr-2023

Relations

Buy Standard

Standard
EN 60317-26:2001
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60317-26:2001
01-september-2001
Specifications for particular types of winding wires - Part 26: Polyamide-imide
enamelled round copper wire, class 200
Specifications for particular types of winding wires -- Part 26: Polyamide-imide enamelled
round copper wire, class 200
Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten -- Teil 26:
Runddrähte aus Kupfer, lackisoliert mit Polyamidimid, Klasse 200
Spécifications pour types particuliers de fils de bobinage -- Partie 26: Fil de section
circulaire en cuivre émaillé avec polyamide-imide, classe 200
Ta slovenski standard je istoveten z: EN 60317-26:1996
ICS:
29.060.10 Žice Wires
SIST EN 60317-26:2001 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60317-26:2001

---------------------- Page: 2 ----------------------

SIST EN 60317-26:2001

---------------------- Page: 3 ----------------------

SIST EN 60317-26:2001

---------------------- Page: 4 ----------------------

SIST EN 60317-26:2001

---------------------- Page: 5 ----------------------

SIST EN 60317-26:2001

---------------------- Page: 6 ----------------------

SIST EN 60317-26:2001
CEI
NORME
INTERNATIONALE IEC
317-26
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
1990-10
Spécifications pour types particuliers
de fils de bobinage
Partie 26:
Fil de section circulaire en cuivre émaillé
avec polyamide-imide, classe 200
Specifications for particular types
of winding wires
Part 26:
Polyamide-imide enamelled round copper wire,
class 200
Numéro de référence
IEC
Reference number

CEI/IEC 317-26: 1990

---------------------- Page: 7 ----------------------

SIST EN 60317-26:2001
317-26 ©IEC - 3 -
CONTENTS
Page
FOREWORD 5
INTRODUCTION 7
Clause
1 Scope
2 Normative references 9
3 Definitions and general notes on methods of test 9
11
4 Dimensions
11 5 Electrical resistance
11
6 Elongation
11
7 Springiness
11
8 Flexibility and adherence
9 Heat shock 11
11
10 Cut-through
11
11 Resistance to abrasion
13
12 Resistance to solvents
13
13 Breakdown voltage
14 Continuity of insulation 13
13
15 Temperature index
15
16 Resistance to refrigerants
15
17 Solderability
18 Heat or solvent bonding 15
15
19 Dielectric dissipa on factor ti
15
20 Resistance to transformer oil
15
21 Loss of mass
15
22 High temperature failure
15
30 Packaging

---------------------- Page: 8 ----------------------

SIST EN 60317-26:2001
317-26 0 IEC - 5 -
INTERNATIONAL ELECTROTECHNICAL COMMISSION
SPECIFICATIONS FOR PARTICULAR TYPES
OF WINDING WIRES
enamelled round copper wire,
Part 26: Polyamide-imide
class 200
FOREWORD
1) The formal decisions or agreements of the IEC on technical matters, prepared by Technical Committees on
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
They have the form of recommendations for international use and they are accepted by the National
2)
Committees in that sense.
3) In order to promote international unification, the IEC expresses the wish that all National Committees
, will
should adopt the text of the IEC recommendation for their national rules in so far as national conditions
permit. Any divergence between the IEC recommendation and the corresponding national rules should, as
far as possible, be clearly indicated in the latter.
This International Standard has been prepared by IEC Technical Committee No. 55:
Winding wires.
This second edition of IEC 317-26 replaces the first edition issued in 1988.
It has been decided to issue IEC 182 and IEC 317 in a new la out. The text of IEC 182
y
All general
has been incorporated into the relevant IEC 317 without technical changes.
requirements for enamelled round copper wires have been removed to IEC 317-0-1 with-
out technical changes unless otherwise stated in the foreword of IEC 317-0-1.

---------------------- Page: 9 ----------------------

SIST EN 60317-26:2001
317-26 © IEC – 7
INTRODUCTION
This International Standard is one of a series which deals with insulated wires used for
windings in electrical equipment. The series has three groups describing:
1) methods of test (IEC 851) ;
2)
specifications (IEC 317);
3) packaging (IEC 264).

---------------------- Page: 10 ----------------------

SIST
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.