SIST EN 302 065 V1.1.1:2008
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Ultra WideBand (UWB) technologies for communication purposes - Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
- Abstract
Draft ETSI Harmonised Standard (EN) including specific new definitions, methods of measurements and limits required for Ultra Wide Band (UWB) technology in close cooperation with ECC.The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes.
The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies.
The present document applies to fixed (indoor only), mobile or portable applications, e.g.:
• stand-alone radio equipment with or without its own control provisions;
• plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.;
• plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.;
• combined equipment or a combination of a plug-in radio device and a specific type of host equipment;
• equipment for use in road and rail vehicles.
The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography).
The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
- Status
- Published
- Public Enquiry End Date
- 31-Jul-2007
- Publication Date
- 02-Jul-2008
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 10-Jun-2008
- Due Date
- 15-Aug-2008
- Completion Date
- 03-Jul-2008
- Mandate
- M/284
Buy Documents
ETSI EN 302 065 V1.1.1 (2007-12) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Ultra WideBand (UWB) technologies for communication purposes; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
ETSI EN 302 065 V1.1.1 (2008-02) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Ultra WideBand (UWB) technologies for communication purposes; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
SIST EN 302 065 V1.1.1:2008 is an ETSI harmonized European Standard for Ultra WideBand (UWB) radio equipment used for short-range communication. It defines the technical requirements, measurement methods, and limits that transceivers, transmitters, and receivers using UWB technologies must meet to support Article 3.2 of the Radio and Telecommunications Terminal Equipment (R&TTE) Directive.
What does SIST EN 302 065 V1.1.1:2008 specify?
SIST EN 302 065 V1.1.1:2008 specifies the radio spectrum and electromagnetic compatibility requirements for UWB communication equipment, including impulse, modified impulse, and RF carrier based technologies. It applies to fixed indoor, mobile, and portable equipment, including stand-alone devices, plug-in radio devices, combined equipment, and equipment used in road and rail vehicles.
The standard covers equipment with either a dedicated antenna connection or an integral antenna. It excludes UWB transmitter equipment intended for fixed outdoor installation and equipment for flying models, aircraft, and other aviation uses.
The document is organized into five clauses and six annexes. Clause 4 sets the technical limits, Clause 5 gives the essential radio test suites, and Annex A links the requirements to the conformance tests.
| Annex | What it covers |
|---|---|
| Annex A | HS Requirements and conformance Test specifications Table (HS-RTT) |
| Annex B | Radiated measurements, test sites, antenna arrangements, coupling, and calibration methods |
| Annex C | Example measurement antenna and preamplifier specifications |
| Annex D | Calculation of the peak limit for 3 MHz measurement bandwidth |
| Annex E | Bibliography |
| Annex F | EN title in the official languages |
What are the key requirements of SIST EN 302 065 V1.1.1:2008?
SIST EN 302 065 V1.1.1:2008 is mainly a limits-and-test standard. The most important practical point is that the equipment must be measured in declared operating modes, against the right limit set, with the right test configuration and uncertainty treatment.
Emission limits and operating bandwidth
- Clause 4.1.1 requires an operating bandwidth greater than 50 MHz, measured at the -23 dB points. In practice, the device must occupy a sufficiently wide band to qualify as UWB under this standard.
- Clause 4.1.2 limits the maximum mean power spectral density, with different limits in different frequency ranges and additional conditions linked to Low Duty Cycle (LDC) and Transmit Power Control (TPC). This matters because the applicable limit depends on how the product is designed and where it is used.
- Clause 4.1.3 limits maximum peak power and explains how the limit changes when the spectrum analyzer uses a different resolution bandwidth. This matters for lab work because the reported peak level depends on the measurement bandwidth.
- Clause 5.8.2 and Clause 5.8.3 define the measurement setups for mean power spectral density and peak power, including the analyzer modes, bandwidth settings, and the need to repeat measurements at band edges. This helps labs compare results consistently.
Timing, power control, and special functions
- Clause 4.1.4 requires TPC for UWB devices intended for road or rail vehicles, and it requires the full power range from highest to lowest level. In practice, the equipment must be able to reduce transmitted power to limit aggregate interference.
- Clause 4.1.6 applies to impulse and modified impulse transmitters and requires a Pulse Repetition Frequency (PRF) of at least 1 MHz, together with a declared pulse timing description. This means the pulse structure has to be documented and meet the minimum repetition rate.
- Clause 4.1.7 applies to devices with LDC in the 3.4 GHz to 4.8 GHz band and sets limits on burst length, spacing, and accumulated transmit time. For users, this means the manufacturer must show that the transmission pattern stays within the allowed duty cycle.
- Clause 4.1.8 sets a transmitter timeout of up to 10 s when there is no acknowledgement response from the associated receiver, except for network control and management information. This matters for systems that must stop talking when a link is not established.
Receiver emissions and test discipline
- Clause 4.1.5 limits receiver spurious emissions in both narrowband and wideband form. In practice, the receiver is not just checked in transmit mode - its unintended emissions in receive mode also have to stay below the stated limits.
- Clause 5.1 requires the manufacturer to declare the UWB technology, modulation, operating ranges, equipment type, antenna combinations, power supply, test modulation, and mitigation features. This information is needed to choose the right test configuration.
- Clause 5.2 requires a test modulation representative of normal use and producing the highest mean transmit power spectral density. If a device supports several modulation schemes, the manufacturer must declare which one is used for the test.
- Clause 5.3 to 5.6 cover test conditions, host or test fixture use for plug-in radio devices, model selection, and measurement uncertainty. This matters because the standard expects results to be taken under controlled, repeatable conditions and recorded with their uncertainty.
What terms does SIST EN 302 065 V1.1.1:2008 define?
- Combined equipment - A mix of non-radio equipment and a plug-in radio device that would not work fully without the radio part.
- Dedicated antenna - A removable antenna supplied and tested with the radio equipment as an indispensable part of it.
- Equivalent isotropically radiated power (e.i.r.p.) - The power radiated in a given direction compared with an isotropic antenna reference.
- Effective radiated power (e.r.p.) - The power radiated in a given direction compared with a half-wave dipole reference.
- Low Duty Cycle (LDC) - Intermittent or burst transmission with long off periods between bursts.
- Pulse Repetition Frequency (PRF) - The minimum number of UWB pulses transmitted per second during continuous transmission of the normal test signal.
- Transmit Power Control (TPC) - A mechanism that provides the full power range and is required for UWB devices intended for road or rail vehicles.
- Plug-in radio device - A radio module intended to work with host, combined, or multi-radio equipment using their control functions and power supply.
Who uses SIST EN 302 065 V1.1.1:2008?
SIST EN 302 065 V1.1.1:2008 is used by UWB equipment manufacturers, RF engineers, and test laboratories that need to demonstrate compliance with the R&TTE radio spectrum requirements. It is also relevant for quality managers and technical file owners who must document declared modes, antenna combinations, and test results.
It is especially relevant for suppliers of stand-alone equipment, plug-in radio devices, combined equipment, and vehicle-mounted UWB systems. Buyers and conformity assessors use it to check whether a product’s operating band, power limits, duty-cycle behavior, and test approach match the intended application.
Which standards are used with SIST EN 302 065 V1.1.1:2008?
| Reference | What it contributes |
|---|---|
| ETSI TR 100 028 | Guidance on measurement uncertainty for mobile radio equipment characteristics |
| ANSI C63.5:2006 | Antenna calibration for radiated emission measurements |
| ITU-R Recommendation SM 329-10 | Treatment of unwanted emissions in the spurious domain |
| ETSI TS 102 321 | Normalized Site Attenuation and validation of a fully lined anechoic chamber up to 40 GHz |
| ITU-R Recommendation SM.1754 | Measurement techniques for UWB transmissions, cited for radiated measurement arrangements |
| ETSI TR 102 273 | Guidance on radiated measurement methods and corresponding measurement uncertainties |
| ETSI TR 102 070-2 | Guidance on harmonized standards for multi-radio and combined radio and non-radio equipment |
What does the SIST EN 302 065 V1.1.1:2008 document contain?
SIST EN 302 065 V1.1.1:2008 contains the requirement-to-test mapping in Annex A, plus detailed radiated measurement guidance in Annex B. Annex B covers anechoic chamber use, conductive ground-plane chambers, antenna types, coupling methods, standard test methods, and a calibration method.
Clause 5.8 gives the practical measurement procedures for mean power spectral density, peak power, operating bandwidth, receiver spurious emissions, LDC, and transmitter timeout. The document also includes analyzer settings, band-edge measurement offsets, and reporting rules for cases where bandwidth or distance has to be adjusted.
Annex C gives example performance data for the horn antenna and preamplifier used for very low UWB radiated levels, and Annex D explains the peak-limit calculation for a 3 MHz measurement bandwidth. These annexes are mainly used when building a lab setup and when converting measured data into values that can be compared with the limits.
Buy Documents
ETSI EN 302 065 V1.1.1 (2007-12) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Ultra WideBand (UWB) technologies for communication purposes; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
ETSI EN 302 065 V1.1.1 (2008-02) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Ultra WideBand (UWB) technologies for communication purposes; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 302 065 V1.1.1:2008 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM) - Ultra WideBand (UWB) technologies for communication purposes - Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive". This standard covers: Draft ETSI Harmonised Standard (EN) including specific new definitions, methods of measurements and limits required for Ultra Wide Band (UWB) technology in close cooperation with ECC.The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes. The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies. The present document applies to fixed (indoor only), mobile or portable applications, e.g.: • stand-alone radio equipment with or without its own control provisions; • plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.; • plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.; • combined equipment or a combination of a plug-in radio device and a specific type of host equipment; • equipment for use in road and rail vehicles. The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography). The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
Draft ETSI Harmonised Standard (EN) including specific new definitions, methods of measurements and limits required for Ultra Wide Band (UWB) technology in close cooperation with ECC.The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes. The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies. The present document applies to fixed (indoor only), mobile or portable applications, e.g.: • stand-alone radio equipment with or without its own control provisions; • plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.; • plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.; • combined equipment or a combination of a plug-in radio device and a specific type of host equipment; • equipment for use in road and rail vehicles. The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography). The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
SIST EN 302 065 V1.1.1:2008 is classified under the following ICS (International Classification for Standards) categories: 33.060.99 - Other equipment for radiocommunications; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 302 065 V1.1.1:2008 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC; Standardization Mandates: M/284. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 302 065 V1.1.1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 7 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 8 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 1 Scope
- 9 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 2 References
- 2.1 Normative references
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 10 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 3.2 Symbols
- 3.3 Abbreviations
- 11 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 4 Technical requirements specification
- 4.1 Technical requirements
- 12 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 13 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 14 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 30 MHz to 1 GHz - 57 dBm (e.r.p.)
- 30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
- 15 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 16 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 5 Essential radio test suites
- 5.1 Product information
- 5.2 Requirements for the test modulation
- 5.3 Test conditions, power supply and ambient temperatures
- 17 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 18 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 5.4 Choice of equipment for test suites
- 19 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 5.5 Testing of host connected equipment and plug-in radio
- 5.6 Interpretation of the measurement results
- 20 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 21 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 5.7 Other emissions from device circuitry
- 5.8 Test procedures for essential radio test suites
- 22 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 23 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 24 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 25 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 26 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 6 Pulse Repetition 4.1.6 C Applies only to X
- 27 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 28 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 29 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 30 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 31 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 32 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 33 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 34 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 35 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 36 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 37 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 38 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 50 MHz RBW
- 3 MHz RBW
- 1 MHz RBW
- 39 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 1.5 MHz
- 6.9 MHz
- 40 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- Bibliography
- 41 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
- 42 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
Introduction
The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive. The modular structure is shown in EG 201 399 (see bibliography).
UWB Technologies The present document provides a generic set of technical requirements covering many different types of UWB technologies used for short range communications. These technologies can be broken down into two groups:
1) Impulse based technologies; and 2) RF carrier based technologies.
The following clauses give a brief overview of these UWB technologies and their associated modulation techniques. ETSI
7 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
Impulse technology Impulse derived UWB technology consists of a series of impulses created from a dc voltage step whose risetime can be modified to provide the maximum useful number of spectral emission frequencies. This derived impulse can then be suitably modified by the use of filters to locate the resulting waveform within a specific frequency spectrum range. This filter can be a stand alone filter or incorporated into an antenna design to reduce emissions outside the designated frequency spectrum.
Modulation techniques include pulse positioning in time, pulse suppression and other techniques to convey information. The transmitted energy is summed at the receiver to reproduce the transmitted pulse. This technology is suitable for direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
RF carrier based technology RF carrier based UWB technology is based upon classical radio carrier technology suitably modulated by a baseband modulating process. The modulating process must produce a bandwidth in excess of 50 MHz to be defined as UWB. Different modulating processes are used to transmit the data information to the receiver and can consist of a series of single hopping frequencies or multi-tone carriers.
This technology can be used for both direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
Test and measurement limitations The ERA report 2006-0713 (see bibliography) has shown that there are practical limitations on measurements of RF radiated emissions. The minimum radiated levels that can be practically measured in the lower GHz frequency range by using a radiated measurement setup with a horn antenna and pre-amplifier are typically in the range of about -70 dBm/MHz to -75 dBm/MHz (e.i.r.p) to have sufficient confidence in the measured result (i.e. UWB signal should be at least 6 dB above the noise floor of the spectrum analyser and the measurement is performed under far-field conditions at a one meter distance). However, RF conducted measurements with a pre-amplifier can be carried out to somewhere around -100 dBm/MHz.
For equipment that have detachable antennas and provide a 50 Ω antenna port, measurements can be made providing suitable antenna calibrations can be provided.
For integrated antenna equipment, previous ETSI testing standards have allowed equipment modification to provide a 50 Ω adaptor to be added to provide the necessary test port. However, UWB integral equipment and particularly impulse based technology does not use classical radio techniques and as such is unlikely to have matched 50 Ω antenna port impedances.
The present document therefore recognizes these difficulties and provides a series of test methods suitable for the different UWB technologies.
ETSI
8 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
1 Scope
The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes.
The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies. The present document applies to fixed (indoor only), mobile or portable applications, e.g.:
- stand-alone radio equipment with or without its own control provisions;
- plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.;
- plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.;
- combined equipment or a combination of a plug-in radio device and a specific type of host equipment;
- equipment for use in road and rail vehicles.
The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography). The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
These radio equipment types are capable of operating in all or part of the frequency bands given in table 1. Table 1: Radiocommunications frequency bands Radiocommunications frequency bands Transmit 3,4 GHz to 4,8 GHz Receive 3,4 GHz to 4,8 GHz Transmit 6,0 GHz to 8,5 GHz Receive 6,0 GHz to 8,5 GHz
ETSI
9 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [2] ANSI C63.5 (2006): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electro Magnetic Interference".
[3] ITU-R Recommendation SM 329-10 (2003): "Unwanted emissions in the spurious domain". [4] ETSI TS 102 321 (V1.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Normalized Site Attenuation (NSA) and validation of a fully lined anechoic chamber up to 40 GHz".
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
combined equipment: any combination of non-radio equipment and a plug-in radio device that would not offer full functionality without the radio device dedicated antenna: removable antenna supplied and tested with the radio equipment, designed as an indispensable part of the equipment effective radiated power (e.r.p): product of the power supplied to the antenna and its gain relative to a half-wave dipole in a given direction (RR 1.162) ETSI
10 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
equivalent isotropically radiated power (e.i.r.p): product of the power supplied to the antenna and the antenna gain in a given direction relative to an isotropic antenna (absolute or isotropic gain) (RR 1.161) gating: transmission that is intermittent or of a low duty cycle referring to the use of burst transmissions where a transmitter is switched on and off for selected time intervals hopping: spread spectrum technique whereby individual radio links are continually switched from one subchannel to another host: host equipment is any equipment which has complete user functionality when not connected to the radio equipment part and to which the radio equipment part provides additional functionality and to which connection is necessary for the radio equipment part to offer functionality impulse: pulse whose width is determined by its dc step risetime and whose maximum amplitude is determined by its dc step value integral antenna: permanent fixed antenna, which may be built-in, designed as an indispensable part of the equipment narrowband: See test in clause 5.8.5.
plug-in radio device: radio equipment module intended to be used with or within host, combined or multi-radio equipment, using their control functions and power supply pulse: short transient signal whose time duration is nominally the reciprocal of its -10 dB bandwidth rf carrier: fixed radio frequency prior to modulation stand-alone radio equipment: equipment that is intended primarily as communications equipment and that is normally used on a stand-alone basis wideband: emission whose occupied bandwidth is greater than the test equipment measurement bandwidth
3.2 Symbols
For the purposes of the present document, the following symbols apply:
f frequency f highest frequency of the power envelope H f lowest frequency of the power envelope L R Distance Ω ohm λ wavelength
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AC Alternate Current ATT ATTenuator/ATTenuation dB deciBel dBi gain in decibels relative to an isotropic antenna dBm gain in decibels relative to one milliwatt DC Direct Current e.i.r.p. equivalent isotropically radiated power e.r.p. effective radiated power EUT Equipment Unter Test LDC Low Duty Cycle LNA Low Noise Amplifier OFDM Orthogonal Frequency Division Multiplexing PRF Pulse Repetition Frequency RBW Resolution BandWidth ETSI
11 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
R&TTE Radio and Telecommunications Terminal Equipment RF Radio Frequency RMS Root Mean Square RR Radio Regulations Rx Receiver SNR Signal to Noise Ratio SRD Short Range Device TPC Transmit Power Control Tx Transmitter UWB Ultra WideBand VBW Video BandWidth VSWR Voltage Standing Wave Ratio
4 Technical requirements specification
4.1 Technical requirements
4.1.1 Operating bandwidth
4.1.1.1 Definition
The width of a frequency band such that, below the lower and above the upper frequency limits, the mean powers emitted are each equal to a percentage of 0,5 % of the total mean power of a given emission. For the purposes of the present document the measurements are made at the -23 dB points.
4.1.1.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.4).
4.1.1.3 Limit
The operating bandwidth shall be greater than 50 MHz (at -23 dB relative to the maximum spectral power density).
4.1.1.4 Measurement uncertainty
See table 9.
NOTE: The operating bandwidth is calculated from the two measured frequencies for which the uncertainty figure for frequency applies. However, the uncertainty of either radiated or conducted power will need to be taken into account when deriving the uncertainty value for frequency measurements at the -23 dB points.
4.1.2 Maximum value of mean power spectral density
4.1.2.1 Definition
The maximum mean power spectral density (specified as e.i.r.p.) of the device under test, at a particular frequency, is the average power per unit bandwidth (centred on that frequency) radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.2.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.2) for the frequencies as shown in table 2.
ETSI
12 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
This test shall be repeated at the frequencies as shown in table 3 including the frequency band edges at 1,6 GHz, 2,7 GHz, 3,4 GHz, 3,8 GHz, 4,2 GHz, 4,8 GHz, 6,0 GHz and 8,5 GHz and 10,6 GHz as shown in table 3.
4.1.2.3 Limit
The maximum mean power spectral density measured using the above test procedure shall not exceed the limits given in tables 2 and 3.
Table 2: Maximum value of mean power spectral density limit Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) 3,4 < f ≤ 4,8 ≤ -41,3 (see note 1) 4,2 < f ≤ 4,8 ≤ -41,3 (see note 2) 6 < f ≤ 8,5 ≤ -41,3 (see note 2) NOTE 1: LDC is required (see clause 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -80 dBm/MHz;
- 3,8 GHz to 4,2 GHz ≤ -70 dBm/MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of mean power spectral density. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -53,3 dBm/MHz;
- 6 GHz to 8,5 GHz ≤ -53,3 dBm/MHz.
Table 3: Maximum value of mean power spectral density limit at frequency band edges Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) f ≤ 1,6 -90 1,6 < f ≤ 2,7 -85 2,7 < f ≤ 3,4 -70 3,4 < f ≤ 3,8 -80 (applies for equipment not using LDC) 3,8 < f ≤ 4,8 -70 (applies for equipment not using LDC) 4,8 < f ≤ 6 -70 8,5 < f ≤ 10,6 -65 f > 10,6 -85
4.1.2.4 Maximum allowable measurement uncertainty
See table 9.
4.1.3 Maximum value of peak power
4.1.3.1 Definition
The power specified as e.i.r.p. contained within a 50 MHz bandwidth at the frequency at which the highest mean radiated power occurs, radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.3.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.3).
4.1.3.3 Limit
The maximum peak power limit measured using the above test procedure shall not exceed the limits given in table 4. ETSI
13 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
Table 4: Maximum peak power limit Frequency Maximum peak power (GHz) (dBm, measured in 50 MHz) 3,4 < f ≤ 4,8 0 (see note 1) 4,2 < f ≤ 4,8 0 (see note 2) 6 < f ≤ 8,5 0 (see note 2) NOTE 1: LDC is required (see 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -40 dBm, measured in 50 MHz;
- 3,8 GHz to 4,2 GHz ≤ -30 dBm, measured in 50 MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of peak power. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -12 dBm, measured in 50 MHz;
- 6 GHz to 8,5 GHz ≤ -12 dBm, measured in 50 MHz.
The power reading on the spectrum analyser can be directly related to the peak power limit when a spectrum analyser resolution bandwidth of 50 MHz is used for the measurements. If a spectrum analyser resolution bandwidth of X MHz is used instead, the maximum peak power limit shall be scaled down by a factor of 20 log (50/X), where X represents the measurement bandwidth used.
EXAMPLE: If the maximum peak power in a particular frequency band is 0 dBm/50 MHz, and a 3 MHz resolution bandwidth is used in case of an impulsive technology, then the measured value shall not exceed -24,4 dBm (see annex D).
For rf carrier based modulation using multi-tone carriers and not having gating techniques implemented, the maximum peak power limit shall be scaled down by a different factor of 10 log(50/X), where X represents the measurement bandwidth used.
4.1.3.4 Maximum allowable measurement uncertainty
See table 9.
4.1.4 Transmit Power Control
4.1.4.1 Definition
Transmit Power Control (TPC) is a mechanism to be used to ensure an interference mitigation on the aggregate power from a large number of devices. The TPC mechanism shall provide the full range from the highest to the lowest power level of the device and is required for UWB devices intended to be used in road or rail vehicles.
4.1.4.2 Test procedure
TPC tests to assess the highest and lowest power spectral density level shall be measured using a radiated or conducted test procedure (see clauses 5.8.2).
4.1.4.3 Limit
The maximum value of power spectral density when configured to operate at the highest level of the TPC range shall not exceed the levels given in table 5a.
Table 5a: Limits for maximum value of power spectral density at the highest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 41,3 6 000 to 8 500 - 41,3
ETSI
14 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
The maximum value of power spectral density when configured to operate at the lowest level of the TPC range shall not exceed the levels given in table 5b.
Table 5b: Limits for maximum value of power spectral density at the lowest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 53,3 6 000 to 8 500 - 53,3
4.1.4.4 Maximum allowable measurement uncertainty
See table 9.
4.1.5 Receiver spurious emissions
4.1.5.1 Definition
Receiver spurious emissions are emissions at any frequency when the equipment is in receive mode.
4.1.5.2 Test procedure
See clause 5.8.5.
4.1.5.3 Limit
The narrowband spurious emissions of the receiver shall not exceed the values in tables 6 and 7 in the indicated bands. Table 6: Narrowband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 57 dBm (e.r.p.)
above 1 GHz to 40 GHz - 47 dBm (e.i.r.p.)
The above limit values apply to narrowband emissions, e.g. as caused by local oscillator leakage. The measurement bandwidth for such emissions may be as small as necessary to get a reliable measurement result. Wideband spurious emissions shall not exceed the values given in table 7. Table 7: Wideband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
above 1 GHz to 40 GHz - 37 dBm/MHz (e.i.r.p.)
4.1.5.4 Maximum allowable measurement uncertainty
See table 9.
4.1.6 Pulse Repetition Frequency (PRF)
This test only applies to impulse and modified impulse UWB transmitters. ETSI
15 Final draft ETSI EN 302 065 V1.1.1 (2007-12)
4.1.6.1 Definitions
For the purposes of the present document the Pulse Repetition Frequency (PRF) is defined as the minimum number of UWB pulses transmitted per second by the device when it is continuously transmitting a normal test signal as defined in clause 5.
4.1.6.2 Declaration
The provider shall give a description of the timing of pulses transmitted by the device and shall declare the minimum PRF for the transmitter under any transmitting condition.
4.1.6.3 Limits
The PRF of the UWB transmitter shall be equal or greater than 1 MHz.
4.1.7 Low Duty Cycle (LDC)
This test only applies to UWB devices with LDC implemented and operating in the frequency band 3,4 GHz to 4,8 GHz.
4.1.7.1 Definitions
Tx on is the duration of a transmission burst and Tx off is the time interval between two consecutive transmission bursts.
...
Contents
- Introduction
- 7 ETSI EN 302 065 V1.1.1 (2008-02)
- 8 ETSI EN 302 065 V1.1.1 (2008-02)
- 1 Scope
- 9 ETSI EN 302 065 V1.1.1 (2008-02)
- 2 References
- 2.1 Normative references
- 2.2 Informative references
- 10 ETSI EN 302 065 V1.1.1 (2008-02)
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 3.2 Symbols
- 11 ETSI EN 302 065 V1.1.1 (2008-02)
- 3.3 Abbreviations
- 4 Technical requirements specification
- 4.1 Technical requirements
- 12 ETSI EN 302 065 V1.1.1 (2008-02)
- 13 ETSI EN 302 065 V1.1.1 (2008-02)
- 14 ETSI EN 302 065 V1.1.1 (2008-02)
- 15 ETSI EN 302 065 V1.1.1 (2008-02)
- 30 MHz to 1 GHz - 57 dBm (e.r.p.)
- 30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
- 16 ETSI EN 302 065 V1.1.1 (2008-02)
- 5 Essential radio test suites
- 5.1 Product information
- 17 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.2 Requirements for the test modulation
- 5.3 Test conditions, power supply and ambient temperatures
- 18 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.4 Choice of equipment for test suites
- 19 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.5 Testing of host connected equipment and plug-in radio
- 20 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.6 Interpretation of the measurement results
- 21 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.7 Other emissions from device circuitry
- 5.8 Test procedures for essential radio test suites
- 22 ETSI EN 302 065 V1.1.1 (2008-02)
- 23 ETSI EN 302 065 V1.1.1 (2008-02)
- 24 ETSI EN 302 065 V1.1.1 (2008-02)
- 25 ETSI EN 302 065 V1.1.1 (2008-02)
- 26 ETSI EN 302 065 V1.1.1 (2008-02)
- 27 ETSI EN 302 065 V1.1.1 (2008-02)
- 6 Pulse Repetition 4.1.6 C Applies only to X
- 28 ETSI EN 302 065 V1.1.1 (2008-02)
- 29 ETSI EN 302 065 V1.1.1 (2008-02)
- 30 ETSI EN 302 065 V1.1.1 (2008-02)
- 31 ETSI EN 302 065 V1.1.1 (2008-02)
- 32 ETSI EN 302 065 V1.1.1 (2008-02)
- 33 ETSI EN 302 065 V1.1.1 (2008-02)
- 34 ETSI EN 302 065 V1.1.1 (2008-02)
- 35 ETSI EN 302 065 V1.1.1 (2008-02)
- 36 ETSI EN 302 065 V1.1.1 (2008-02)
- 37 ETSI EN 302 065 V1.1.1 (2008-02)
- 38 ETSI EN 302 065 V1.1.1 (2008-02)
- 39 ETSI EN 302 065 V1.1.1 (2008-02)
- 50 MHz RBW
- 3 MHz RBW
- 1 MHz RBW
- 40 ETSI EN 302 065 V1.1.1 (2008-02)
- 1.5 MHz
- 6.9 MHz
- 41 ETSI EN 302 065 V1.1.1 (2008-02)
- Bibliography
- 42 ETSI EN 302 065 V1.1.1 (2008-02)
- 43 ETSI EN 302 065 V1.1.1 (2008-02)
Introduction
The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive. The modular structure is shown in EG 201 399 (see bibliography).
UWB Technologies The present document provides a generic set of technical requirements covering many different types of UWB technologies used for short range communications. These technologies can be broken down into two groups:
1) Impulse based technologies; and 2) RF carrier based technologies.
ETSI
7 ETSI EN 302 065 V1.1.1 (2008-02)
The following clauses give a brief overview of these UWB technologies and their associated modulation techniques. Impulse technology Impulse derived UWB technology consists of a series of impulses created from a dc voltage step whose risetime can be modified to provide the maximum useful number of spectral emission frequencies. This derived impulse can then be suitably modified by the use of filters to locate the resulting waveform within a specific frequency spectrum range. This filter can be a stand alone filter or incorporated into an antenna design to reduce emissions outside the designated frequency spectrum.
Modulation techniques include pulse positioning in time, pulse suppression and other techniques to convey information. The transmitted energy is summed at the receiver to reproduce the transmitted pulse. This technology is suitable for direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
RF carrier based technology RF carrier based UWB technology is based upon classical radio carrier technology suitably modulated by a baseband modulating process. The modulating process must produce a bandwidth in excess of 50 MHz to be defined as UWB. Different modulating processes are used to transmit the data information to the receiver and can consist of a series of single hopping frequencies or multi-tone carriers.
This technology can be used for both direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
Test and measurement limitations The ERA report 2006-0713 (see bibliography) has shown that there are practical limitations on measurements of RF radiated emissions. The minimum radiated levels that can be practically measured in the lower GHz frequency range by using a radiated measurement setup with a horn antenna and pre-amplifier are typically in the range of about -70 dBm/MHz to -75 dBm/MHz (e.i.r.p) to have sufficient confidence in the measured result (i.e. UWB signal should be at least 6 dB above the noise floor of the spectrum analyser and the measurement is performed under far-field conditions at a one meter distance). However, RF conducted measurements with a pre-amplifier can be carried out to somewhere around -100 dBm/MHz.
For equipment that have detachable antennas and provide a 50 Ω antenna port, measurements can be made providing suitable antenna calibrations can be provided.
For integrated antenna equipment, previous ETSI testing standards have allowed equipment modification to provide a 50 Ω adaptor to be added to provide the necessary test port. However, UWB integral equipment and particularly impulse based technology does not use classical radio techniques and as such is unlikely to have matched 50 Ω antenna port impedances.
The present document therefore recognizes these difficulties and provides a series of test methods suitable for the different UWB technologies.
ETSI
8 ETSI EN 302 065 V1.1.1 (2008-02)
1 Scope
The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes.
The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies. The present document applies to fixed (indoor only), mobile or portable applications, e.g.:
- stand-alone radio equipment with or without its own control provisions;
- plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.;
- plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.;
- combined equipment or a combination of a plug-in radio device and a specific type of host equipment;
- equipment for use in road and rail vehicles.
The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography). The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
These radio equipment types are capable of operating in all or part of the frequency bands given in table 1. Table 1: Radiocommunications frequency bands Radiocommunications frequency bands Transmit 3,4 GHz to 4,8 GHz Receive 3,4 GHz to 4,8 GHz Transmit 6,0 GHz to 8,5 GHz Receive 6,0 GHz to 8,5 GHz
ETSI
9 ETSI EN 302 065 V1.1.1 (2008-02)
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [2] ANSI C63.5 (2006): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electro Magnetic Interference".
[3] ITU-R Recommendation SM 329-10 (2003): "Unwanted emissions in the spurious domain". [4] ETSI TS 102 321 (V1.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Normalized Site Attenuation (NSA) and validation of a fully lined anechoic chamber up to 40 GHz".
2.2 Informative references
None.
ETSI
10 ETSI EN 302 065 V1.1.1 (2008-02)
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
combined equipment: any combination of non-radio equipment and a plug-in radio device that would not offer full functionality without the radio device dedicated antenna: removable antenna supplied and tested with the radio equipment, designed as an indispensable part of the equipment effective radiated power (e.r.p): product of the power supplied to the antenna and its gain relative to a half-wave dipole in a given direction (RR 1.162) equivalent isotropically radiated power (e.i.r.p): product of the power supplied to the antenna and the antenna gain in a given direction relative to an isotropic antenna (absolute or isotropic gain) (RR 1.161) gating: transmission that is intermittent or of a low duty cycle referring to the use of burst transmissions where a transmitter is switched on and off for selected time intervals hopping: spread spectrum technique whereby individual radio links are continually switched from one subchannel to another host: host equipment is any equipment which has complete user functionality when not connected to the radio equipment part and to which the radio equipment part provides additional functionality and to which connection is necessary for the radio equipment part to offer functionality impulse: pulse whose width is determined by its dc step risetime and whose maximum amplitude is determined by its dc step value integral antenna: permanent fixed antenna, which may be built-in, designed as an indispensable part of the equipment narrowband: See test in clause 5.8.5.
plug-in radio device: radio equipment module intended to be used with or within host, combined or multi-radio equipment, using their control functions and power supply pulse: short transient signal whose time duration is nominally the reciprocal of its -10 dB bandwidth rf carrier: fixed radio frequency prior to modulation stand-alone radio equipment: equipment that is intended primarily as communications equipment and that is normally used on a stand-alone basis wideband: emission whose occupied bandwidth is greater than the test equipment measurement bandwidth
3.2 Symbols
For the purposes of the present document, the following symbols apply:
f frequency f highest frequency of the power envelope H f lowest frequency of the power envelope L R Distance Ω ohm λ wavelength ETSI
11 ETSI EN 302 065 V1.1.1 (2008-02)
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AC Alternate Current ATT ATTenuator/ATTenuation dB deciBel dBi gain in decibels relative to an isotropic antenna dBm gain in decibels relative to one milliwatt DC Direct Current e.i.r.p. equivalent isotropically radiated power e.r.p. effective radiated power EUT Equipment Unter Test LDC Low Duty Cycle LNA Low Noise Amplifier OFDM Orthogonal Frequency Division Multiplexing PRF Pulse Repetition Frequency RBW Resolution BandWidth R&TTE Radio and Telecommunications Terminal Equipment RF Radio Frequency RMS Root Mean Square RR Radio Regulations Rx Receiver SNR Signal to Noise Ratio SRD Short Range Device TPC Transmit Power Control Tx Transmitter UWB Ultra WideBand VBW Video BandWidth VSWR Voltage Standing Wave Ratio
4 Technical requirements specification
4.1 Technical requirements
4.1.1 Operating bandwidth
4.1.1.1 Definition
The width of a frequency band such that, below the lower and above the upper frequency limits, the mean powers emitted are each equal to a percentage of 0,5 % of the total mean power of a given emission. For the purposes of the present document the measurements are made at the -23 dB points.
4.1.1.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.4).
4.1.1.3 Limit
The operating bandwidth shall be greater than 50 MHz (at -23 dB relative to the maximum spectral power density). ETSI
12 ETSI EN 302 065 V1.1.1 (2008-02)
4.1.1.4 Measurement uncertainty
See table 9.
NOTE: The operating bandwidth is calculated from the two measured frequencies for which the uncertainty figure for frequency applies. However, the uncertainty of either radiated or conducted power will need to be taken into account when deriving the uncertainty value for frequency measurements at the -23 dB points.
4.1.2 Maximum value of mean power spectral density
4.1.2.1 Definition
The maximum mean power spectral density (specified as e.i.r.p.) of the device under test, at a particular frequency, is the average power per unit bandwidth (centred on that frequency) radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.2.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.2) for the frequencies as shown in table 2.
This test shall be repeated at the frequencies as shown in table 3 including the frequency band edges at 1,6 GHz, 2,7 GHz, 3,4 GHz, 3,8 GHz, 4,2 GHz, 4,8 GHz, 6,0 GHz and 8,5 GHz and 10,6 GHz as shown in table 3.
4.1.2.3 Limit
The maximum mean power spectral density measured using the above test procedure shall not exceed the limits given in tables 2 and 3.
Table 2: Maximum value of mean power spectral density limit Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) 3,4 < f ≤ 4,8 ≤ -41,3 (see note 1) 4,2 < f ≤ 4,8 ≤ -41,3 (see note 2) 6 < f ≤ 8,5 ≤ -41,3 (see note 2) NOTE 1: LDC is required (see clause 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -80 dBm/MHz;
- 3,8 GHz to 4,2 GHz ≤ -70 dBm/MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of mean power spectral density. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -53,3 dBm/MHz;
- 6 GHz to 8,5 GHz ≤ -53,3 dBm/MHz.
ETSI
13 ETSI EN 302 065 V1.1.1 (2008-02)
Table 3: Maximum value of mean power spectral density limit at frequency band edges Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) f ≤ 1,6 -90 1,6 < f ≤ 2,7 -85 2,7 < f ≤ 3,4 -70 3,4 < f ≤ 3,8 -80 (applies for equipment not using LDC) 3,8 < f ≤ 4,8 -70 (applies for equipment not using LDC) 4,8 < f ≤ 6 -70 8,5 < f ≤ 10,6 -65 f > 10,6 -85
4.1.2.4 Maximum allowable measurement uncertainty
See table 9.
4.1.3 Maximum value of peak power
4.1.3.1 Definition
The power specified as e.i.r.p. contained within a 50 MHz bandwidth at the frequency at which the highest mean radiated power occurs, radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.3.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.3).
4.1.3.3 Limit
The maximum peak power limit measured using the above test procedure shall not exceed the limits given in table 4. Table 4: Maximum peak power limit Frequency Maximum peak power (GHz) (dBm, measured in 50 MHz) 3,4 < f ≤ 4,8 0 (see note 1) 4,2 < f ≤ 4,8 0 (see note 2) 6 < f ≤ 8,5 0 (see note 2) NOTE 1: LDC is required (see 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -40 dBm, measured in 50 MHz;
- 3,8 GHz to 4,2 GHz ≤ -30 dBm, measured in 50 MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of peak power. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -12 dBm, measured in 50 MHz;
- 6 GHz to 8,5 GHz ≤ -12 dBm, measured in 50 MHz.
The power reading on the spectrum analyser can be directly related to the peak power limit when a spectrum analyser resolution bandwidth of 50 MHz is used for the measurements. If a spectrum analyser resolution bandwidth of X MHz is used instead, the maximum peak power limit shall be scaled down by a factor of 20 log (50/X), where X represents the measurement bandwidth used.
EXAMPLE: If the maximum peak power in a particular frequency band is 0 dBm/50 MHz, and a 3 MHz resolution bandwidth is used in case of an impulsive technology, then the measured value shall not exceed -24,4 dBm (see annex D).
ETSI
14 ETSI EN 302 065 V1.1.1 (2008-02)
For rf carrier based modulation using multi-tone carriers and not having gating techniques implemented, the maximum peak power limit shall be scaled down by a different factor of 10 log(50/X), where X represents the measurement bandwidth used.
4.1.3.4 Maximum allowable measurement uncertainty
See table 9.
4.1.4 Transmit Power Control
4.1.4.1 Definition
Transmit Power Control (TPC) is a mechanism to be used to ensure an interference mitigation on the aggregate power from a large number of devices. The TPC mechanism shall provide the full range from the highest to the lowest power level of the device and is required for UWB devices intended to be used in road or rail vehicles.
4.1.4.2 Test procedure
TPC tests to assess the highest and lowest power spectral density level shall be measured using a radiated or conducted test procedure (see clauses 5.8.2).
4.1.4.3 Limit
The maximum value of power spectral density when configured to operate at the highest level of the TPC range shall not exceed the levels given in table 5a.
Table 5a: Limits for maximum value of power spectral density at the highest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 41,3 6 000 to 8 500 - 41,3
The maximum value of power spectral density when configured to operate at the lowest level of the TPC range shall not exceed the levels given in table 5b.
Table 5b: Limits for maximum value of power spectral density at the lowest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 53,3 6 000 to 8 500 - 53,3
4.1.4.4 Maximum allowable measurement uncertainty
See table 9.
4.1.5 Receiver spurious emissions
4.1.5.1 Definition
Receiver spurious emissions are emissions at any frequency when the equipment is in receive mode.
4.1.5.2 Test procedure
See clause 5.8.5.
ETSI
15 ETSI EN 302 065 V1.1.1 (2008-02)
4.1.5.3 Limit
The narrowband spurious emissions of the receiver shall not exceed the values in tables 6 and 7 in the indicated bands. Table 6: Narrowband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 57 dBm (e.r.p.)
above 1 GHz to 40 GHz - 47 dBm (e.i.r.p.)
The above limit values apply to narrowband emissions, e.g. as caused by local oscillator leakage. The measurement bandwidth for such emissions may be as small as necessary to get a reliable measurement result. Wideband spurious emissions shall not exceed the values given in table 7. Table 7: Wideband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
above 1 GHz to 40 GHz - 37 dBm/MHz (e.i.r.p.)
4.1.5.4 Maximum allowable measurement uncertainty
See table 9.
4.1.6 Pulse Repetition Frequency (PRF)
This test only applies to impulse and modified impulse UWB transmitters.
4.1.6.1 Definitions
For the purposes of the present document the Pulse Repetition Frequency (PRF) is defined as the minimum number of UWB pulses transmitted per second by the device when it is continuously transmitting a normal test signal as defined in clause 5.
4.1.6.2 Declaration
The provider shall give a description of the timing of pulses transmitted by the device and shall declare the minimum PRF for the transmitter under any transmitting condition.
4.1.6.3 Limits
The PRF of the UWB transmitter shall be equal or greater than 1 MHz.
4.1.7 Low Duty Cycle (LDC)
This test only applies to UWB devices with LDC implemented and operating in the frequency band 3,4 GHz to 4,8 GHz.
4.1.7.1 Definitions
Tx on is the duration of a transmission burst and Tx off is the time interval between two consecutive transmission bursts.
...
Contents
- Introduction
- 7 ETSI EN 302 065 V1.1.1 (2008-02)
- 8 ETSI EN 302 065 V1.1.1 (2008-02)
- 1 Scope
- 9 ETSI EN 302 065 V1.1.1 (2008-02)
- 2 References
- 2.1 Normative references
- 2.2 Informative references
- 10 ETSI EN 302 065 V1.1.1 (2008-02)
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 3.2 Symbols
- 11 ETSI EN 302 065 V1.1.1 (2008-02)
- 3.3 Abbreviations
- 4 Technical requirements specification
- 4.1 Technical requirements
- 12 ETSI EN 302 065 V1.1.1 (2008-02)
- 13 ETSI EN 302 065 V1.1.1 (2008-02)
- 14 ETSI EN 302 065 V1.1.1 (2008-02)
- 15 ETSI EN 302 065 V1.1.1 (2008-02)
- 30 MHz to 1 GHz - 57 dBm (e.r.p.)
- 30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
- 16 ETSI EN 302 065 V1.1.1 (2008-02)
- 5 Essential radio test suites
- 5.1 Product information
- 17 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.2 Requirements for the test modulation
- 5.3 Test conditions, power supply and ambient temperatures
- 18 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.4 Choice of equipment for test suites
- 19 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.5 Testing of host connected equipment and plug-in radio
- 20 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.6 Interpretation of the measurement results
- 21 ETSI EN 302 065 V1.1.1 (2008-02)
- 5.7 Other emissions from device circuitry
- 5.8 Test procedures for essential radio test suites
- 22 ETSI EN 302 065 V1.1.1 (2008-02)
- 23 ETSI EN 302 065 V1.1.1 (2008-02)
- 24 ETSI EN 302 065 V1.1.1 (2008-02)
- 25 ETSI EN 302 065 V1.1.1 (2008-02)
- 26 ETSI EN 302 065 V1.1.1 (2008-02)
- 27 ETSI EN 302 065 V1.1.1 (2008-02)
- 6 Pulse Repetition 4.1.6 C Applies only to X
- 28 ETSI EN 302 065 V1.1.1 (2008-02)
- 29 ETSI EN 302 065 V1.1.1 (2008-02)
- 30 ETSI EN 302 065 V1.1.1 (2008-02)
- 31 ETSI EN 302 065 V1.1.1 (2008-02)
- 32 ETSI EN 302 065 V1.1.1 (2008-02)
- 33 ETSI EN 302 065 V1.1.1 (2008-02)
- 34 ETSI EN 302 065 V1.1.1 (2008-02)
- 35 ETSI EN 302 065 V1.1.1 (2008-02)
- 36 ETSI EN 302 065 V1.1.1 (2008-02)
- 37 ETSI EN 302 065 V1.1.1 (2008-02)
- 38 ETSI EN 302 065 V1.1.1 (2008-02)
- 39 ETSI EN 302 065 V1.1.1 (2008-02)
- 50 MHz RBW
- 3 MHz RBW
- 1 MHz RBW
- 40 ETSI EN 302 065 V1.1.1 (2008-02)
- 1.5 MHz
- 6.9 MHz
- 41 ETSI EN 302 065 V1.1.1 (2008-02)
- Bibliography
- 42 ETSI EN 302 065 V1.1.1 (2008-02)
- 43 ETSI EN 302 065 V1.1.1 (2008-02)
Introduction
The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive. The modular structure is shown in EG 201 399 (see bibliography).
UWB Technologies The present document provides a generic set of technical requirements covering many different types of UWB technologies used for short range communications. These technologies can be broken down into two groups:
1) Impulse based technologies; and 2) RF carrier based technologies.
ETSI
SIST EN 302 065 V1.1.1:2008
7 ETSI EN 302 065 V1.1.1 (2008-02)
The following clauses give a brief overview of these UWB technologies and their associated modulation techniques. Impulse technology Impulse derived UWB technology consists of a series of impulses created from a dc voltage step whose risetime can be modified to provide the maximum useful number of spectral emission frequencies. This derived impulse can then be suitably modified by the use of filters to locate the resulting waveform within a specific frequency spectrum range. This filter can be a stand alone filter or incorporated into an antenna design to reduce emissions outside the designated frequency spectrum.
Modulation techniques include pulse positioning in time, pulse suppression and other techniques to convey information. The transmitted energy is summed at the receiver to reproduce the transmitted pulse. This technology is suitable for direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
RF carrier based technology RF carrier based UWB technology is based upon classical radio carrier technology suitably modulated by a baseband modulating process. The modulating process must produce a bandwidth in excess of 50 MHz to be defined as UWB. Different modulating processes are used to transmit the data information to the receiver and can consist of a series of single hopping frequencies or multi-tone carriers.
This technology can be used for both direct and non-direct line of sight communications, any reflected or time delayed emissions being suppressed by the receiver input circuits.
Test and measurement limitations The ERA report 2006-0713 (see bibliography) has shown that there are practical limitations on measurements of RF radiated emissions. The minimum radiated levels that can be practically measured in the lower GHz frequency range by using a radiated measurement setup with a horn antenna and pre-amplifier are typically in the range of about -70 dBm/MHz to -75 dBm/MHz (e.i.r.p) to have sufficient confidence in the measured result (i.e. UWB signal should be at least 6 dB above the noise floor of the spectrum analyser and the measurement is performed under far-field conditions at a one meter distance). However, RF conducted measurements with a pre-amplifier can be carried out to somewhere around -100 dBm/MHz.
For equipment that have detachable antennas and provide a 50 Ω antenna port, measurements can be made providing suitable antenna calibrations can be provided.
For integrated antenna equipment, previous ETSI testing standards have allowed equipment modification to provide a 50 Ω adaptor to be added to provide the necessary test port. However, UWB integral equipment and particularly impulse based technology does not use classical radio techniques and as such is unlikely to have matched 50 Ω antenna port impedances.
The present document therefore recognizes these difficulties and provides a series of test methods suitable for the different UWB technologies.
ETSI
SIST EN 302 065 V1.1.1:2008
8 ETSI EN 302 065 V1.1.1 (2008-02)
1 Scope
The present document applies to transceivers, transmitters and receivers utilizing Ultra WideBand (UWB) technologies and used for short range communication purposes.
The present document applies to impulse, modified impulse and RF carrier based UWB communication technologies. The present document applies to fixed (indoor only), mobile or portable applications, e.g.:
- stand-alone radio equipment with or without its own control provisions;
- plug-in radio devices intended for use with, or within, a variety of host systems, e.g. personal computers, hand-held terminals, etc.;
- plug-in radio devices intended for use within combined equipment, e.g. cable modems, set-top boxes, access points, etc.;
- combined equipment or a combination of a plug-in radio device and a specific type of host equipment;
- equipment for use in road and rail vehicles.
The present document does not cover UWB transmitter equipment to be installed at a fixed outdoor location or for use in flying models, aircraft and other forms of aviation as per the ECC/DEC/(06)04 (see bibliography). The present document applies to UWB equipment with an output connection used with a dedicated antenna or UWB equipment with an integral antenna.
These radio equipment types are capable of operating in all or part of the frequency bands given in table 1. Table 1: Radiocommunications frequency bands Radiocommunications frequency bands Transmit 3,4 GHz to 4,8 GHz Receive 3,4 GHz to 4,8 GHz Transmit 6,0 GHz to 8,5 GHz Receive 6,0 GHz to 8,5 GHz
ETSI
SIST EN 302 065 V1.1.1:2008
9 ETSI EN 302 065 V1.1.1 (2008-02)
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
2.1 Normative references
The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [2] ANSI C63.5 (2006): "American National Standard for Calibration of Antennas Used for Radiated Emission Measurements in Electro Magnetic Interference".
[3] ITU-R Recommendation SM 329-10 (2003): "Unwanted emissions in the spurious domain". [4] ETSI TS 102 321 (V1.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Normalized Site Attenuation (NSA) and validation of a fully lined anechoic chamber up to 40 GHz".
2.2 Informative references
None.
ETSI
SIST EN 302 065 V1.1.1:2008
10 ETSI EN 302 065 V1.1.1 (2008-02)
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
combined equipment: any combination of non-radio equipment and a plug-in radio device that would not offer full functionality without the radio device dedicated antenna: removable antenna supplied and tested with the radio equipment, designed as an indispensable part of the equipment effective radiated power (e.r.p): product of the power supplied to the antenna and its gain relative to a half-wave dipole in a given direction (RR 1.162) equivalent isotropically radiated power (e.i.r.p): product of the power supplied to the antenna and the antenna gain in a given direction relative to an isotropic antenna (absolute or isotropic gain) (RR 1.161) gating: transmission that is intermittent or of a low duty cycle referring to the use of burst transmissions where a transmitter is switched on and off for selected time intervals hopping: spread spectrum technique whereby individual radio links are continually switched from one subchannel to another host: host equipment is any equipment which has complete user functionality when not connected to the radio equipment part and to which the radio equipment part provides additional functionality and to which connection is necessary for the radio equipment part to offer functionality impulse: pulse whose width is determined by its dc step risetime and whose maximum amplitude is determined by its dc step value integral antenna: permanent fixed antenna, which may be built-in, designed as an indispensable part of the equipment narrowband: See test in clause 5.8.5.
plug-in radio device: radio equipment module intended to be used with or within host, combined or multi-radio equipment, using their control functions and power supply pulse: short transient signal whose time duration is nominally the reciprocal of its -10 dB bandwidth rf carrier: fixed radio frequency prior to modulation stand-alone radio equipment: equipment that is intended primarily as communications equipment and that is normally used on a stand-alone basis wideband: emission whose occupied bandwidth is greater than the test equipment measurement bandwidth
3.2 Symbols
For the purposes of the present document, the following symbols apply:
f frequency f highest frequency of the power envelope H f lowest frequency of the power envelope L R Distance Ω ohm λ wavelength ETSI
SIST EN 302 065 V1.1.1:2008
11 ETSI EN 302 065 V1.1.1 (2008-02)
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AC Alternate Current ATT ATTenuator/ATTenuation dB deciBel dBi gain in decibels relative to an isotropic antenna dBm gain in decibels relative to one milliwatt DC Direct Current e.i.r.p. equivalent isotropically radiated power e.r.p. effective radiated power EUT Equipment Unter Test LDC Low Duty Cycle LNA Low Noise Amplifier OFDM Orthogonal Frequency Division Multiplexing PRF Pulse Repetition Frequency RBW Resolution BandWidth R&TTE Radio and Telecommunications Terminal Equipment RF Radio Frequency RMS Root Mean Square RR Radio Regulations Rx Receiver SNR Signal to Noise Ratio SRD Short Range Device TPC Transmit Power Control Tx Transmitter UWB Ultra WideBand VBW Video BandWidth VSWR Voltage Standing Wave Ratio
4 Technical requirements specification
4.1 Technical requirements
4.1.1 Operating bandwidth
4.1.1.1 Definition
The width of a frequency band such that, below the lower and above the upper frequency limits, the mean powers emitted are each equal to a percentage of 0,5 % of the total mean power of a given emission. For the purposes of the present document the measurements are made at the -23 dB points.
4.1.1.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.4).
4.1.1.3 Limit
The operating bandwidth shall be greater than 50 MHz (at -23 dB relative to the maximum spectral power density). ETSI
SIST EN 302 065 V1.1.1:2008
12 ETSI EN 302 065 V1.1.1 (2008-02)
4.1.1.4 Measurement uncertainty
See table 9.
NOTE: The operating bandwidth is calculated from the two measured frequencies for which the uncertainty figure for frequency applies. However, the uncertainty of either radiated or conducted power will need to be taken into account when deriving the uncertainty value for frequency measurements at the -23 dB points.
4.1.2 Maximum value of mean power spectral density
4.1.2.1 Definition
The maximum mean power spectral density (specified as e.i.r.p.) of the device under test, at a particular frequency, is the average power per unit bandwidth (centred on that frequency) radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.2.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.2) for the frequencies as shown in table 2.
This test shall be repeated at the frequencies as shown in table 3 including the frequency band edges at 1,6 GHz, 2,7 GHz, 3,4 GHz, 3,8 GHz, 4,2 GHz, 4,8 GHz, 6,0 GHz and 8,5 GHz and 10,6 GHz as shown in table 3.
4.1.2.3 Limit
The maximum mean power spectral density measured using the above test procedure shall not exceed the limits given in tables 2 and 3.
Table 2: Maximum value of mean power spectral density limit Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) 3,4 < f ≤ 4,8 ≤ -41,3 (see note 1) 4,2 < f ≤ 4,8 ≤ -41,3 (see note 2) 6 < f ≤ 8,5 ≤ -41,3 (see note 2) NOTE 1: LDC is required (see clause 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -80 dBm/MHz;
- 3,8 GHz to 4,2 GHz ≤ -70 dBm/MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of mean power spectral density. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -53,3 dBm/MHz;
- 6 GHz to 8,5 GHz ≤ -53,3 dBm/MHz.
ETSI
SIST EN 302 065 V1.1.1:2008
13 ETSI EN 302 065 V1.1.1 (2008-02)
Table 3: Maximum value of mean power spectral density limit at frequency band edges Frequency Maximum value of mean power (GHz) spectral density (dBm/MHz) f ≤ 1,6 -90 1,6 < f ≤ 2,7 -85 2,7 < f ≤ 3,4 -70 3,4 < f ≤ 3,8 -80 (applies for equipment not using LDC) 3,8 < f ≤ 4,8 -70 (applies for equipment not using LDC) 4,8 < f ≤ 6 -70 8,5 < f ≤ 10,6 -65 f > 10,6 -85
4.1.2.4 Maximum allowable measurement uncertainty
See table 9.
4.1.3 Maximum value of peak power
4.1.3.1 Definition
The power specified as e.i.r.p. contained within a 50 MHz bandwidth at the frequency at which the highest mean radiated power occurs, radiated in the direction of the maximum level under the specified conditions of measurement.
4.1.3.2 Test procedure
This test shall be performed using a radiated or conducted test procedure (see clause 5.8.3).
4.1.3.3 Limit
The maximum peak power limit measured using the above test procedure shall not exceed the limits given in table 4. Table 4: Maximum peak power limit Frequency Maximum peak power (GHz) (dBm, measured in 50 MHz) 3,4 < f ≤ 4,8 0 (see note 1) 4,2 < f ≤ 4,8 0 (see note 2) 6 < f ≤ 8,5 0 (see note 2) NOTE 1: LDC is required (see 4.1.7). If LDC is not implemented then the following applies:
- 3,4 GHz to 3,8 GHz ≤ -40 dBm, measured in 50 MHz;
- 3,8 GHz to 4,2 GHz ≤ -30 dBm, measured in 50 MHz.
NOTE 2: In case of devices installed in road and rail vehicles, operation is subject to the implementation of Transmit Power Control (TPC) with a range of 12 dB with respect to the maximum value of peak power. If TPC is not implemented then the following applies:
- 4,2 GHz to 4,8 GHz ≤ -12 dBm, measured in 50 MHz;
- 6 GHz to 8,5 GHz ≤ -12 dBm, measured in 50 MHz.
The power reading on the spectrum analyser can be directly related to the peak power limit when a spectrum analyser resolution bandwidth of 50 MHz is used for the measurements. If a spectrum analyser resolution bandwidth of X MHz is used instead, the maximum peak power limit shall be scaled down by a factor of 20 log (50/X), where X represents the measurement bandwidth used.
EXAMPLE: If the maximum peak power in a particular frequency band is 0 dBm/50 MHz, and a 3 MHz resolution bandwidth is used in case of an impulsive technology, then the measured value shall not exceed -24,4 dBm (see annex D).
ETSI
SIST EN 302 065 V1.1.1:2008
14 ETSI EN 302 065 V1.1.1 (2008-02)
For rf carrier based modulation using multi-tone carriers and not having gating techniques implemented, the maximum peak power limit shall be scaled down by a different factor of 10 log(50/X), where X represents the measurement bandwidth used.
4.1.3.4 Maximum allowable measurement uncertainty
See table 9.
4.1.4 Transmit Power Control
4.1.4.1 Definition
Transmit Power Control (TPC) is a mechanism to be used to ensure an interference mitigation on the aggregate power from a large number of devices. The TPC mechanism shall provide the full range from the highest to the lowest power level of the device and is required for UWB devices intended to be used in road or rail vehicles.
4.1.4.2 Test procedure
TPC tests to assess the highest and lowest power spectral density level shall be measured using a radiated or conducted test procedure (see clauses 5.8.2).
4.1.4.3 Limit
The maximum value of power spectral density when configured to operate at the highest level of the TPC range shall not exceed the levels given in table 5a.
Table 5a: Limits for maximum value of power spectral density at the highest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 41,3 6 000 to 8 500 - 41,3
The maximum value of power spectral density when configured to operate at the lowest level of the TPC range shall not exceed the levels given in table 5b.
Table 5b: Limits for maximum value of power spectral density at the lowest level of the TPC range Frequency range Power spectral density limit (e.i.r.p.) (MHz) (dBm/MHz) 4 200 to 4 800 - 53,3 6 000 to 8 500 - 53,3
4.1.4.4 Maximum allowable measurement uncertainty
See table 9.
4.1.5 Receiver spurious emissions
4.1.5.1 Definition
Receiver spurious emissions are emissions at any frequency when the equipment is in receive mode.
4.1.5.2 Test procedure
See clause 5.8.5.
ETSI
SIST EN 302 065 V1.1.1:2008
15 ETSI EN 302 065 V1.1.1 (2008-02)
4.1.5.3 Limit
The narrowband spurious emissions of the receiver shall not exceed the values in tables 6 and 7 in the indicated bands. Table 6: Narrowband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 57 dBm (e.r.p.)
above 1 GHz to 40 GHz - 47 dBm (e.i.r.p.)
The above limit values apply to narrowband emissions, e.g. as caused by local oscillator leakage. The measurement bandwidth for such emissions may be as small as necessary to get a reliable measurement result. Wideband spurious emissions shall not exceed the values given in table 7. Table 7: Wideband spurious emission limits for receivers Frequency range Limit
30 MHz to 1 GHz - 47 dBm/MHz (e.r.p.)
above 1 GHz to 40 GHz - 37 dBm/MHz (e.i.r.p.)
4.1.5.4 Maximum allowable measurement uncertainty
See table 9.
4.1.6 Pulse Repetition Frequency (PRF)
This test only applies to impulse and modified impulse UWB transmitters.
4.1.6.1 Definitions
For the purposes of the present document the Pulse Repetition Frequency (PRF) is defined as the minimum number of UWB pulses transmitted per second by the device when it is continuously transmitting a normal test signal as defined in clause 5.
4.1.6.2 Declaration
The provider shall give a description of the timing of pulses transmitted by the device and shall declare the minimum PRF for the transmitter under any transmitting condition.
4.1.6.3 Limits
The PRF of the UWB transmitter shall be equal or greater than 1 MHz.
4.1.7 Low Duty Cycle (LDC)
This test only applies to UWB devices with LDC implemented and operating in the frequency band 3,4 GHz to 4,8 GHz.
...