SIST EN 50525-2-71:2011
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-71: Starkstromleitungen für allgemeine Anwendungen - Lahnlitzen-Leitungen mit thermoplastischer PVCIsolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 2-71: Câbles pour applications générales - Câbles plats pour cordons à fil rosette, isolés en PVC thermoplastique
Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V (U0/U) - 2-71. del: Kabli za splošno uporabo - Ploščate opletene niti s termoplastično PVC izolacijo
Ta evropski standard velja za ploščate zvijave opletene kable s termoplastično (PVC) izolacijo. Ti kabli imajo nazivno napetost U0/U do vključno 300/300 V. Povezujejo male gospodinjske aparate s fiksnim napajanjem. Maksimalna delovna temperatura pretvornika za kable iz tega standarda je
40 °C.
General Information
- Status
- Published
- Public Enquiry End Date
- 28-Feb-2009
- Publication Date
- 15-Jun-2011
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Jun-2011
- Due Date
- 13-Aug-2011
- Completion Date
- 16-Jun-2011
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 07-Jun-2022
- Effective Date
- 07-Jun-2022
- Effective Date
- 07-Jun-2022
- Effective Date
- 06-Jan-2009
- Effective Date
- 06-Jan-2009
- Effective Date
- 06-Jan-2009
Overview
EN 50525-2-71:2011 is the CENELEC part standard for flat tinsel cables (cords) with thermoplastic PVC insulation intended for general applications. It applies to flexible, flat tinsel cables of CENELEC code H03VH-Y, rated at U0/U 300/300 V, primarily used to connect small appliances to a fixed supply. The standard defines constructional requirements, marking, testing procedures and operating limitations including a maximum conductor operating temperature of 40 °C.
This Part should be read together with EN 50525-1, which sets out the general requirements for low-voltage energy cables.
Key Topics
Construction
- Two parallel conductors formed from flattened wires helically wound on a textile thread.
- Conductors are insulated with a PVC compound of Type TI 2 (per EN 50363-3).
- Insulation includes grooves between cores to facilitate separation.
- Marking: cables must be identified with the CENELEC code H03VH-Y and comply with EN 50525-1 marking rules.
Electrical and dimensional requirements
- Rated voltage: U0/U 300/300 V.
- Typical insulation thickness: 0.8 mm.
- Mean overall dimensions: approximately 2.2 × 4.4 mm up to 3.5 × 7.0 mm (limits given in Table B.1 of the standard).
- Maximum conductor resistance at 20 °C: 270 Ω/km (see Table B.1).
- Minimum insulation resistance at 70 °C specified in the standard.
Testing and mechanical durability
- Test methods are referenced in Annex A and include EN 50395 (electrical tests), EN 50396 (non-electrical and mechanical tests) and EN 60332-1-2 (vertical flame test).
- Bending test: 60 000 bending cycles (120 000 single strokes) with no interruption of current; followed by a 1 500 V post-test voltage check between conductors (connected together) and water.
- Snatch test: no interruption of current during the test (per EN 50396 requirements).
Applications
EN 50525-2-71:2011 covers flexible flat tinsel cables used for:
- Connection leads for small household and portable appliances
- Lightweight cord sets and replacement cords where flexibility and compact flat form are required
Benefits for manufacturers and specifiers:
- Ensures consistent construction and safety properties for low-voltage flat cords
- Aligns product marking and testing with harmonized European requirements
- Provides clear mechanical and electrical test criteria for quality control
Related Standards
- EN 50525-1 - General requirements for low-voltage energy cables (must be read in conjunction)
- EN 50363-3 - PVC insulating compounds (Type TI 2)
- EN 50395 - Electrical test methods for low-voltage energy cables
- EN 50396 - Non-electrical and mechanical test methods
- EN 60332-1-2 - Vertical flame propagation test (1 kW pre-mixed flame)
- EN 60811-1-4 - Low temperature tests for insulating and sheathing materials
For procurement, design or compliance checks, reference EN 50525-2-71:2011 to verify construction, marking and the required suite of tests for H03VH-Y PVC insulated flat tinsel cords.
Frequently Asked Questions
SIST EN 50525-2-71:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation". This standard covers: This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.
This European Standard applies to thermoplastic (PVC) insulated flexible flat tinsel flexible cables. The cables are of rated voltage U0/U 300/300 V. The cables are intended for the connection of small appliances to the fixed supply. The maximum conductor operating temperature for the cable in this standard is 40 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-71 should be read in conjunction with EN 50525-1, which specifies general requirements.
SIST EN 50525-2-71:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50525-2-71:2011 has the following relationships with other standards: It is inter standard links to SIST HD 21.5 S3:1998, SIST HD 21.5 S3:1998/A1:2000, SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998/A1:2000, SIST HD 21.5 S3:1998, SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998, SIST HD 21.5 S3:1998/A2:2002, SIST HD 21.5 S3:1998/A1:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 50525-2-71:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 50525-2-71:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR988GHO.DEOL]DVSORãQRXSRUDER3ORãþDWHRSOHWHQH
QLWLVWHUPRSODVWLþQR39&L]RODFLMR
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with
thermoplastic PVC insulation
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-71: Starkstromleitungen für allgemeine Anwendungen - Lahnlitzen-Leitungen mit
thermoplastischer PVCIsolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 2-71: Câbles pour applications générales - Câbles plats pour
cordons à fil rosette, isolés en PVC thermoplastique
Ta slovenski standard je istoveten z: EN 50525-2-71:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50525-2-71
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 21.5 S3:1994 (partially) + A1:1999 (partially) + A2:2001 (partially)
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 2-71: Cables for general applications -
Flat tinsel cables (cords) with thermoplastic PVC insulation
Câbles électriques - Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) -
Teil 2-71: Starkstromleitungen für
Partie 2-71: Câbles pour applications allgemeine Anwendungen -
générales - Lahnlitzen-Leitungen mit
Câbles plats pour cordons à fil rosette, thermoplastischer PVC-Isolierung
isolés en PVC thermoplastique
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-71:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric
cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-2-71 on 2011-01-17.
This document, which is one of a multipart series, supersedes Clause 2 of HD 21.5 S3:1994 +
A1:1999 + A2:2001.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17
_____________
- 3 - EN 50525-2-71:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Flexible cables – H03VH-Y . 4
4.1 Construction . 4
4.2 Requirements . 5
Annex A (normative) Tests for cables to EN 50525-2-71 . 6
Annex B (normative) General data . 7
Annex C (normative) Requirements for mechanical tests on completed cables . 8
C.1 Bending test . 8
C.2 Snatch test. 8
Bibliography . 9
Tables
Table A.1 . 6
Table B.1
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.