SIST EN 1172:1998
(Main)Copper and copper alloys - Sheet and strip for building purposes
Copper and copper alloys - Sheet and strip for building purposes
This European Standard specifies requirements for copper sheet and strip in thicknesses from 0,5 mm up to and including 1 mm and in widths up to and including 1250 mm. This standard is applicable to sheet and strip for use in building construction, e.g. for roof drainage systems, gutters, downpipes, roof coverings, external wall claddings, dormer windows, verges, chimney flashings and roof valleys.
Kupfer und Kupferlegierungen - Bleche für das Bauwesen
Diese Europäische Norm legt die Anforderungen an Bleche und Bänder aus Kupfer in Dicken von 0,5 mm bis einschliesslich 1mm und Breiten bis einschließlich 1250 mm fest. Diese Norm ist anwendbar auf Bleche und Bänder für den Gebrauch im Bauwesen, z. B. für Dachentwässerungen, Dachrinnen, Regelfallrohre, Dachdeckungen, Aussenwandbekleidungen, Dachgauben, Ortgänge, Schornsteinverwahrungen und Kehlen.
Cuivre et alliages de cuivre - Tôles et bandes pour le bâtiment
La présente norme européenne spécifie les caractéristiques des tôles et bandes en cuivre d'épaisseur comprise entre 0,5 et 1 mm inclus et de largeur inférieure ou égale a 1250 mm. La présente norme s'applique aux tôles et bandes utilisées dans le bâtiment, par exemple pour réaliser les systemes de drainage des toitures, les gouttieres, les tuyaux de descente, les revetements de toitures, les revetements extérieurs de murs, les fenetres de toit, les bandes façonnées, les noquets de cheminées et les noues.
Baker in bakrove zlitine - Pločevine in trakovi za gradbeništvo
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kupfer und Kupferlegierungen - Bleche für das BauwesenCuivre et alliages de cuivre - Tôles et bandes pour le bâtimentCopper and copper alloys - Sheet and strip for building purposes77.150.30Bakreni izdelkiCopper productsICS:Ta slovenski standard je ist
...
This May Also Interest You
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard51 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft50 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the composition and property requirements for cathodes of two copper grades, designated Cu-CATH-1 (CR001A) and Cu-CATH-2 (CR002A).
Annex A (normative) describes methods for sampling cathodes for use in cases of dispute between the purchaser and the supplier. Annex B (informative) gives information on the relationships between electrical resistivity and conductivity of copper.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies methods for assessing the tin coating on drawn round copper wire for the manufacture of electrical conductors, e.g. according to EN 13602.
This European Standard includes test methods for the determination of the following characteristics:
a) thickness of the unalloyed tin coating;
b) continuity of the tin coating;
c) adherence of the tin coating.
WARNING - This European Standard can involve the use of hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with their use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard22 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the composition, property requirements including electrical properties, and tolerances on dimensions and form for copper rod, bar and wire for general electrical purposes. Cross sections and size ranges are:
- round, square and hexagonal rod with diameters or widths across flats from 2 mm up to and including 160 mm;
- bar with thicknesses from 2 mm up to and including 40 mm and widths from 3 mm up to and including 250 mm;
- round, square, hexagonal and rectangular wire with diameters or widths across flats from 2 mm up to and including 25 mm, as well as thicknesses from 0,5 mm up to and including 12 mm with widths from 1 mm up to and including 250 mm.
The sampling procedures and test methods for verification of conformity to the requirements of this standard are also specified.
NOTE Drawn, round copper wire - plain or tinned, single or multiline - for the manufacture of electrical conductors is specified in EN 13602.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft28 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the composition, property requirements including electrical properties, and tolerances on dimensions and form for copper profiles and profiled wire for electrical purposes, which would fit within a circumscribing circle of maximum 180 mm diameter.
The sampling procedures, the test methods for verification of conformity to the requirements of this standard, and the delivery conditions are also specified.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft29 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for fittings with ends for capillary soldering or capillary brazing for connecting with copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2 etc. For the purposes of joining copper tubes, the fitting ends have a size range from 6 mm to 108 mm. These fitting ends exist in three forms: end feed fittings and integral solder and integral brazing ring fitting ends. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and corresponding maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings for soldering or brazing to copper tubes are used with solder alloys in accordance with alloys specified in EN ISO 9453 and brazing alloys in accordance with alloys specified in EN ISO 17672.
Adaptor fittings for use with copper tubes may combine capillary soldering or capillary brazing ends with fitting ends defined in the other parts of EN 1254.
Capillary fittings for soldering or brazing may also have flanged end connections according to EN 1092-3.
Capillary fittings for soldering or brazing may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
- refrigeration systems;
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft33 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for press fittings including their elastomeric seals, for connecting with metallic tubes. The fitting ends have a size range from 6 mm to 108 mm. The press fittings are designed for a service lifetime up to fifty years.
This document is applicable to press fittings for joining one or more of the following tubes:
- copper tubes to EN 1057 and
- stainless steel tubes to EN 10312
with wall thicknesses and tempers as specified by the manufacturer.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
Press fittings are used with tubes with wall thicknesses greater than or equal to the wall thickness given in Annex B, to ensure that tubes can withstand the radial pressing forces involved.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with copper tubes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with metallic tubes may also have flanged end connections according to EN 1092-3.
Press fittings for use with metallic tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot or cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard34 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for push-fit fittings for the purpose of joining tubes of copper, plated copper, multilayer pipes and plastics pipes. The fitting ends have a size range from 6 mm to 54 mm. The fittings are designed for a service lifetime up to fifty years.
This document is applicable to push-fit fittings for joining one or more of the following tubes or pipes:
- copper tubes to EN 1057; copper composite according to UNI 11342, plastic and multilayer pipes covered by EN 15015.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings may combine push-fit ends with fitting ends defined in the other parts of EN 1254.
Push-fit fittings for metallic tubes may also have flanged end connections according to EN 1092-3.
Push-fit fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft33 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for capillary fittings with short ends for brazing to copper tubes e.g. EN 1057, EN 13348, EN 13349, EN 12735-1, EN 12735-2, etc. These fitting ends exist in two forms: end feed fittings and integral brazing ring fittings. For the purposes of joining copper tubes, the fitting ends have a size range from 14,7 mm to 159 mm. The fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
The capillary fittings with short ends for brazing to copper tubes are used with brazing alloys in accordance with alloys specified in EN ISO 17672.
Not all copper alloys that can be used to manufacture fittings can be brazed and those that can be brazed may require different brazing techniques (guidance is provided in in prEN1254-20:2019, Annex A).
Fittings with short ends for capillary brazing may also have threaded end connections. These threaded ends exist with metallic and with non-metallic sealing elements. For the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 1/8" to 4".
Adaptor fittings for use with copper tubes may combine short ends for capillary brazing with fitting ends defined in the other parts of EN 1254.
Capillary fittings with short ends for brazing may also have flanged end connections according to EN 1092-3.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
- refrigeration systems.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems;
- medical gas systems according to EN ISO 7396;
- refrigeration systems.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft31 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for compression fittings for connecting with copper tubes. Compression fittings exist with sealing elements - metallic and/or non-metallic - called non manipulative (commonly referenced as type A) and without sealing elements, called manipulative (commonly referenced as type B). For the purposes of joining copper tubes, the fitting ends have a size range from 6 mm to 108 mm. The compression fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Compression fitting ends, Type A, are used with copper tubes to EN 1057 in all material hardness conditions.
NOTE 1 Compression fittings, Type A, will possibly require an internal support when used with R220 (annealed) copper tube and the manufacturer’s advice should be sought.
Compression fitting ends, Type B, are used with R220 (annealed) or R250 (half-hard) copper tube to EN 1057.
NOTE 2 Compression fittings, Type B, may be used with R290 (hard) copper tube and the manufacturer’s advice should be sought.
Adaptor fittings for use with copper tubes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with copper tubes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with copper tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft32 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion