kSIST prES 202 874-1 V1.2.1:2012
(Main)Access, Terminals, Transmission and Multiplexing (ATTM) - External Common Power Supply for Customer Premises Network and Access Equipment - Part 1: Functional requirements
- Abstract
Revision of ES 202 874-1 that defines functional requirements for different categories of CPS for Customer Premises Equipment. The main activity will consist in aligning the ES with the work done for TS 102 874-6
- Status
- Not Published
- Technical Committee
- SPN - Services and Protocols for Networks
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 06-Apr-2012
- Due Date
- 25-May-2012
- Completion Date
- 08-May-2012
kSIST prES 202 874-1 V1.2.1:2012 is SIST’s publication of ETSI ES 202 874-1 for the External Common Power Supply (CPS) used with customer premises network and access equipment. It specifies the functional requirements for CPS categories, including operating range, efficiency, connector compatibility, reliability, and eco-design. In practice, it is the document for manufacturers, service providers, and buyers who need a common external power supply for home gateways, home network infrastructure devices, and similar customer equipment.
What does kSIST prES 202 874-1 V1.2.1:2012 specify?
kSIST prES 202 874-1 V1.2.1:2012 specifies a universal AC-to-DC CPS solution for customer equipment used in home networks, powered from 100 V to 240 V AC at 50 Hz to 60 Hz. It applies to Customer Network Gateway, Home Network Infrastructure Device, and Customer Network Device use cases, and it excludes other power-delivery methods such as Power over Ethernet and power on USB.
The document is organized into clauses 1 to 8. Clause 4 covers market scenarios and use cases, clause 5 covers operating conditions, clause 6 covers energy efficiency, clause 7 covers connectors, and clause 8 covers eco-design. Annex A is an informative bibliography.
What are the key requirements of kSIST prES 202 874-1 V1.2.1:2012?
Operating range and power classes
kSIST prES 202 874-1 V1.2.1:2012 requires all CPS categories to accept the stated AC input range and keep the DC output within a tight tolerance at the load end under line, load, and environmental conditions. It also defines a family of power classes, from a low-power 5 V type to several 12 V subcategories for different load levels.
In practice, this means the supply is not just a generic adapter. The device and the CPS must be matched as a pair so that the load gets the expected voltage and enough current without using an over-sized or incompatible unit.
EMC, safety, and network coexistence
kSIST prES 202 874-1 V1.2.1:2012 requires compliance with applicable EU directives and points to safety and EMC standards used when the CPS is assessed with its intended load or as a standalone unit. It also includes coexistence considerations for xDSL and Powerline communications (PLT), including limits on noise impact and a design goal to avoid reducing PLT throughput.
The practical effect is that the CPS must be checked not only for basic electrical function, but also for interference. For deployments on DSL or mains-borne data networks, the supply has to be quiet enough not to disturb line performance.
Reliability, protection, and environment
kSIST prES 202 874-1 V1.2.1:2012 sets long-life and reliability expectations, including a 10-year continuous-operation target and a Mean Time Between Failures (MTBF) requirement. It also requires enhanced protection per ITU-T K.21 and defines operating, storage, and transport conditions for temperature and humidity.
For the reader, this means the CPS is intended to survive service-provider deployment, spare-use, transport, and seasonal variation. Reliability and environmental limits matter because the same power supply may be reused across device generations.
Energy efficiency and measurement
kSIST prES 202 874-1 V1.2.1:2012 aligns energy-efficiency requirements with regional obligations and uses the US EPA Energy Star test method for measurement. It requires reporting at no-load and at several load points, so efficiency is checked across the range rather than only at one operating point.
This is important in procurement and qualification because the CPS must meet efficiency expectations in real use, not just on a best-case test bench. Higher-power categories have stricter efficiency targets, which helps compare candidate supplies during design selection.
Connectors and misconnection prevention
kSIST prES 202 874-1 V1.2.1:2012 requires each CPS variant to use a unique connector type, and the connector arrangement must prevent connection to a device that was not designed for that CPS type. The detailed connector definition is left to the companion technical specifications for the individual CPS types.
In practice, the connector is part of the safety and compatibility strategy. The goal is to reduce wrong pairing, misoperation, and the use of the wrong voltage class on the wrong device.
Eco-design and materials
kSIST prES 202 874-1 V1.2.1:2012 requires the outer case to be made from recyclable plastic and prefers recycled plastic, with a preference away from PVC in cables and low-halogen materials in electronic parts. It also requires the product to be designed so the plastic case and electronics can be separated at end of life, while meeting safety requirements.
For manufacturers, this means material choice and disassembly have to be considered at the design stage, not after the product is frozen. The standard also links the CPS to hazardous-substance restrictions in EU law.
What terms does kSIST prES 202 874-1 V1.2.1:2012 define?
- Common Power Supply (CPS) - An external power supply intended to serve customer premises network and access equipment with defined common categories.
- Customer Network (CN) - The in-house network made up of the home gateway, end devices, network segments, and home network infrastructure devices; also called Home Network (HN) or Customer Premises Network (CPN).
- Customer Network Gateway (CNG) - The gateway between the home network and the access network; also called Home Gateway (HG) or Small Business Gateway (SBG).
- Customer Network Device (CND) - A physical device that enables service use; also called End Device (ED).
- Home Network Infrastructure Device (HNID) - A home-network device such as a bridge, hub, switch, repeater, or access point that supports the network rather than the end service.
- Mean Time Between Failures (MTBF) - The reliability metric used to express the expected operating time between failures.
- Power Line Technologies (PLT) - Data transmission over the mains wiring, which is a specific coexistence case for the CPS.
- Quiet Line Noise (QLN) - A DSL noise measurement used to compare line performance with a reference battery and with the CPS in place.
Who uses kSIST prES 202 874-1 V1.2.1:2012?
kSIST prES 202 874-1 V1.2.1:2012 is used by CPS manufacturers, home gateway and set-top-box designers, and vendors of home-network equipment that needs an external adapter. Broadband Service Providers (BSPs) use it when they want a reusable power supply across customer installations, spares, or equipment refreshes.
Quality, compliance, and procurement teams use it to check operating ratings, connector compatibility, EMC, efficiency, environmental performance, and eco-design claims. It is also relevant to integrators working on DSL modems, home gateways, optical network terminations, NAS devices, and similar customer-premises products.
What changed in kSIST prES 202 874-1 V1.2.1:2012 from the previous edition?
kSIST prES 202 874-1 V1.2.1:2012 is a revision of ES 202 874-1, and the scope says the work aligns the standard with TS 102 874-6. The document history records V1.1.1 from October 2010 as the earlier publication and V1.2.1 from March 2012 as the later version.
Which standards are used with kSIST prES 202 874-1 V1.2.1:2012?
- Commission Regulation (EC) No 278/2009 and Energy Star requirements - Provide the external-power-supply ecodesign and efficiency framework used by the standard.
- US EPA test method for single-voltage external AC-DC and AC-AC power supplies - Provides the efficiency measurement method used in clause 6.
- CENELEC EN 60950-1, EN 55022, EN 55024, EN 61000-4-11, EN 61000-4-2, EN 61000-4-5, and EN 61000-3-2 - Support safety, emissions, and immunity assessment.
- IEEE 1413 - Provides a framework for hardware reliability prediction, used when discussing MTBF.
- ETSI EN 300 019-1-1, EN 300 019-1-2, and EN 300 019-1-3 - Define storage, transportation, and stationary-use environmental classes.
- ITU-T Recommendation G.992.3 and ITU-T Recommendation K.21 - Support the DSL coexistence discussion and protection requirements.
- Directive 2011/65/EC - Provides the hazardous-substances restriction linked to eco-design.
- ETSI TS 102 874-2 to ETSI TS 102 874-6 - Give the companion implementation details for the CPS categories, while this document sets the functional requirements.
- HGI-RD001-R2 and HGI-RD015-R3 - Provide the residential-profile and CPS energy-efficiency background used in the series.
What does the kSIST prES 202 874-1 V1.2.1:2012 document contain?
Table 1 maps the CPS categories to the companion parts of the series, and Table 2 groups the categories by voltage, current, intended application, and typical connector style. The figures show the usual power-supply block arrangements for the lower-power types and the higher-power Type 2.c arrangement with a separate mains connection.
Clause 5 includes the operating-condition requirements and the suggested checks for xDSL quiet-line-noise and PLT coexistence. Clause 6 gives the energy-efficiency test approach and the extra reporting points beyond the main efficiency test method. Annex A is a bibliography for related connector, power-supply, and PLC references.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
kSIST prES 202 874-1 V1.2.1:2012 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Access, Terminals, Transmission and Multiplexing (ATTM) - External Common Power Supply for Customer Premises Network and Access Equipment - Part 1: Functional requirements". This standard covers: Revision of ES 202 874-1 that defines functional requirements for different categories of CPS for Customer Premises Equipment. The main activity will consist in aligning the ES with the work done for TS 102 874-6
Revision of ES 202 874-1 that defines functional requirements for different categories of CPS for Customer Premises Equipment. The main activity will consist in aligning the ES with the work done for TS 102 874-6
kSIST prES 202 874-1 V1.2.1:2012 is classified under the following ICS (International Classification for Standards) categories: 33.060.40 - Cabled distribution systems. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST prES 202 874-1 V1.2.1:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
ETSI Standard
Access, Terminals, Transmission and Multiplexing (ATTM);
External Common Power Supply for
Customer Premises Network and Access Equipment;
Part 1: Functional requirements
2 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
Reference
RES/ATTM-02021
Keywords
connector, EMC, LAN, power supply, terminal
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2012.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
Contents
Intellectual Property Rights . 4
Foreword . 4
Introduction . 4
1 Scope and Purpose . 6
1.1 Scope . 6
1.2 Applicability . 6
1.3 Requirements Notation . 6
2 References . 7
2.1 Normative references . 7
2.2 Informative references . 8
3 Definitions and abbreviations . 9
3.1 Definitions . 9
3.2 Abbreviations . 9
4 Market scenarios and use cases . 10
4.1 The state of the art . 10
4.1.1 Market situation . 10
4.1.2 Power supply energy efficiency issues . 11
4.2 CPS categories . 11
4.2.1 Connectors . 12
4.2.2 Reliability and environmental conditions . 12
4.3 The usage scenarios . 12
4.4 Usability issues and CPS elements . 13
4.5 Coexistence with Powerline communications . 14
5 Requirements for CPS operating conditions . 16
5.1 EMC and safety requirements . 17
5.2 Reliability . 18
5.3 Protection . 18
5.4 Environmental conditions . 18
6 Requirements for CPS energy efficiency . 18
6.1 Efficiency targets . 18
6.2 Efficiency measurement method . 19
7 Requirements for CPS connectors . 19
8 Requirements for CPS eco-design . 19
Annex A (informative): Bibliography . 21
History . 22
ETSI
4 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This final draft ETSI Standard (ES) has been produced by ETSI Technical Committee Access, Terminals, Transmission
and Multiplexing (ATTM), and is now submitted for the ETSI standards Membership Approval Procedure.
The present document is part 1 of a multi-part deliverable covering the External Common Power Supply (CPS) for
Customer Premises Network and Access Equipment, as identified below:
ES 202 874-1: "Functional requirements";
TS 102 874-2: "Integrated Broadband Cable and Television Networks";
TS 102 874-3: "CPS Type 1 implementation details";
TS 102 874-4: "CPS Type 2.b implementation details";
TS 102 874-5: "CPS Type 2.c implementation details";
TS 102 874-6: "CPS Type 2.d implementation details".
Introduction
The present document addresses the functional requirements and implementation and operational aspects of the
External Common Power Supply (CPS) for Customer Premises Network and Access Equipment.
The multi-part deliverable represents a set of cohesive interwoven technical information that has jointly evolved to
define solution of most efficient equipment, as defined below:
• ES 202 874-1 defines functional requirements for four different categories of CPS.
• TS 102 874-2 [i.1] defines detailed implementation and operational aspects for CPS Type 2.a.
• TS 102 874-3 [i.2] defines detailed implementation and operational aspects for CPS Type 1.
• TS 102 874-4 [i.3] defines detailed implementation and operational aspects for CPS Type 2.b.
• TS 102 874-5 [i.4] defines detailed implementation and operational aspects for CPS Type 2.c.
• TS 102 874-6 [i.7] defines detailed implementation and operational aspects for CPS Type 2.d.
The intended applications of these CPS categories are specified in the present document.
ETSI
5 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
Table 1 summarises the structure of the series.
Table 1: Multi-part deliverable structure
CPS category Functional requirements Implementation aspects
Type 1: 5 V, 2 A TS 102 874-3 [i.2]
Type 2.a: 12 V, 1 A TS 102 874-2 [i.1]
Type 2.b: 12 V, 2 A ES 202 874-1 TS 102 874-4 [i.3]
Type 2.c: 12 V, 5 A TS 102 874-5 [i.4]
Type 2.d: 12 V, 3,2 A TS 102 874-6 [i.7]
The present document is describing functional requirements applicable to an external common power supply (CPS)
converting and adapting AC mains to DC power for customer premises network equipment. Other methods for
providing power to end devices are not in the scope of the present document (e.g. Power Over Ethernet, power on USB,
etc.).
The requirements were defined on the basis of HGI (Home Gateway Initiative) activity on the same subject contained in
the public document HGI-RD015-R3 [i.5]. That is the result of collaborative efforts of HGI members that include
Broadband Service Providers (BSPs), gateway manufacturers, and silicon vendors.
The present document is defining operating conditions, energy efficiency and ecodesign aspects for a number of
categories of power supplies, depending on market applicability and power needs of the targeted Customer Premises
Equipment (CPEs). Additional Technical Specifications will address the implementation aspects for each of the CPS
categories here defined, including the choice of connectors.
The need for standardization activities in energy efficiency and ecodesign related to telecommunications is now widely
seen. For example the European Union, in the "ICT 2009 Standardization Work Programme" [i.6] highlights this need.
Enabling the use of standardized power supplies, or the development of a new Common Power Supply (CPS) for DSL
modems, home gateways, optical network terminations is a key aspect of telecommunications standardization that will
contribute to ecodesign.
The expected timeline for adoption of the present document is as follows:
• Initial, partial deployments prior to 2011 depending on availability of specific TSs.
• Universal deployments for customer premises equipment within service providers' networks (i.e. within those
service providers mandating these requirements) starting from 2011.
ETSI
6 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
1 Scope and Purpose
1.1 Scope
The present document specifies a universal solution for power supplies (named Common Power Supply and indicated
with the acronym CPS) suitable for customer equipment used in the home networks, using energy provided by mains
power in a range between 100 V and 240 V AC and 50 Hz to 60 Hz of frequency (apart tolerances). The topics
addressed in the present document are as follows:
• applicability: definition of product categories included in the scope (home gateway, and various other devices
installed in the home network);
• market scenarios and use cases for the use of the CPS in the home environment;
• functional requirements for electrical operating conditions of the CPS;
• functional requirements for energy efficiency of the CPS;
• functional requirements for connectors on the CPS and devices which it powers;
• functional requirements for eco-design of the CPS.
1.2 Applicability
Customer Network Gateway (CNG) Power Supply
Customer Network Gateways, also called Home gateways, currently use external power supplies ("bricks") that provide
different ranges of output voltage and current.
Furthermore, the connectors on the HG which attach to the power supply, and the corresponding connectors on the
cable frequently differ, not only between HGs of different vendors, but also between different HG models from the
same vendor. A suitable output voltage and current, along with connector type would have to be specified to create a
truly "universal" solution applicable to all home gateways.
Home Network Infrastructure Devices (HNIDs) Power Supply
In addition to home gateways, other home network infrastructure devices (HNIDs) may use a power supply with similar
features in terms of voltage and current, so that a common solution could be defined for both types of device.
These HNID devices may have a similar specification and distribution process, in other words they are managed and/or
supplied by a common BSP. Therefore, the extension of the CPS solution defined for HGs to HNIDs has also been
considered.
End Device Power Supply
Some end user devices use power supplies with similar characteristics to those of CNGs (e.g. some set top boxes,
cordless phones and IP phones).
The requirements contained in the present document apply to all the above mentioned categories.
1.3 Requirements Notation
If the present document is implemented, the key words "MUST" and "SHALL" as well as "REQUIRED" are to be
interpreted as indicating a mandatory aspect of the present document. The keywords indicating a certain level of
significance of a particular requirement that are used throughout the present document are summarized below.
MUST: This word or the adjective "REQUIRED" means that the item is an absolute requirement of the present
document.
MUST NOT: This phrase means that the item is an absolute prohibition of the present document.
ETSI
7 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
SHOULD: This word or the adjective "RECOMMENDED" means that there may exist valid reasons in particular
circumstances to ignore this item, but the full implications should be understood and the case carefully weighed before
choosing a different course.
SHOULD NOT: This phrase means that there may exist valid reasons in particular circumstances when the listed
behaviour is acceptable or even useful, but the full implications should be understood and the case carefully weighed
before implementing any behaviour described with this label.
MAY: This word or the adjective "OPTIONAL" means that this item is truly optional. One vendor may choose to
include the item because a particular marketplace requires it or because it enhances the product, for example; another
vendor may omit the same item.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] Home Gateway Initiative HGI-RD001-R2 (2008): "Technical Requirements: Residential Profile
V1.0".
NOTE: Available at: http://www.homegatewayinitiative.org/publis/HGI_V1.01_Residential.pdf.
[2] Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC
of the European Parliament and of the Council with regard to ecodesign requirements for no-load
condition electric power consumption and average active efficiency of external power supplies.
[3] Energy Star®: "Program Requirements for Single Voltage External Ac-Dc and Ac-Ac Power
Supplies - Eligibility Criteria (Version 2.0)".
[4] Public Law 110-140 (19 December 2007): "Energy Independence and Security Act of 2007".
[5] United States Environmental Protection Agency (US EPA) (11 August 2004): "Test Method for
Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac Power Supplies".
[6] CENELEC EN 60950-1 (2006): "Information technology equipment - Safety - Part 1: General
requirements".
[7] CENELEC EN 55022 (2006) and Amendment 1 (2007): "Information technology equipment -
Radio disturbance characteristics - Limits and methods of measurement".
[8] CENELEC EN 55024 (1998), Amendment 1 (2001) and Amendment 2 (2003): "Information
technology equipment - Immunity characteristics - Limits and methods of measurement".
[9] IEEE 1413 (2010): "Standard Framework for Reliability Prediction of Hardware".
[10] ETSI EN 300 019-1-1: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
ETSI
8 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
[11] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weather protected locations".
[12] ETSI EN 300 019-1-2: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-2: Classification of Environmental
Conditions; Transportation".
[13] ITU-T Recommendation G.992.3: "Asymmetric digital subscriber line transceivers 2 (ADSL2)".
[14] ITU-T Recommendation K.21: "Resistibility of telecommunication equipment installed in
customer premises to overvoltages and overcurrents".
[15] CISPR 22: "Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement".
[16] CENELEC EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[17] CENELEC EN 61000-4-2: "Electromagnetic compatibility (EMC) - Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[18] CENELEC EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4-5: Testing and
measurement techniques - Surge immunity test".
[19] CENELEC EN 61000-3-2: "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current <= 16 A per phase)".
[20] Directive 2011/65/EC of the European Parliament and of the Council of 8 June 2011 on the
restriction of the use of certain hazardous substances in electrical and electronic equipment
(recast).
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI TS 102 874-2: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 2: Integrated
Broadband Cable and Television Networks".
[i.2] ETSI TS 102 874-3: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 3: CPS
Type 1 implementation details".
[i.3] ETSI TS 102 874-4: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 4: CPS
Type 2.b implementation details".
[i.4] ETSI TS 102 874-5: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 5: CPS
Type 2.c implementation details".
[i.5] Home Gateway Initiative HGI-RD015-R3: "Energy Efficiency and Ecodesign requirements for a
common power supply (CPS) for home gateway, home networking equipment and end devices".
[i.6] European Commission: "ICT 2009 Standardization Work Programme".
NOTE: Available at: http://ec.europa.eu/enterprise/sectors/ict/files/wp2009_en.pdf.
[i.7] ETSI TS 102 874-6: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 6: CPS
Type 2.d implementation details".
ETSI
9 Final draft ETSI ES 202 874-1 V1.2.1 (2012-03)
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
Customer Network (CN): in-house network composed by home gateway, end devices, network segments (physical
wired or wireless connections between customer network elements), home network infrastructure devices such as
network adapters (performing a L1/L2 conversion between different network segments) and nodes (network adapters
with L3 routing capabilities)
NOTE: Also called Home Network (HN) or Customer Premises Network (CPN).
Customer Network Gateway (CNG): gateway between the HN and the Access Network able to perform networking
functions from physical connection to bridging and routing capabilities, but also possibly implementing functions
related to the service support
NOTE: Also called Home Gateway (HG) or Small Business Gateway (SBG).
Customer Network Device (CND): physical device enabling service(s) usage
NOTE 1: Also called End Device (ED).
NOTE 2: EDs can be dedicated to the internet, conversational and audio-video services. But they could be also
Consumer Electronics equipment and other devices which may have nothing to do with these premium
services (e.g. services performing a content sharing within a HN, typically between a PC and a music
system, through the HG).
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ABS Acrylonitrile Butadiene Styrene
AC Alternating Current
BSP Broadband Service Provider
CND Customer Network Device
CNG Customer Network Gateway
CPE Customer Premises Equipment
CPN Customer Premises Network
CPS Common Power Supply
DC Direct Current
DSL Digital Subscriber Line
ED End Device
EMC ElectroMagnetic Compatibility
EuP Energy-using Products
HG Home Gateway
HGI Home Gateway Initiative
HNID Home Network Infrastructure Device
ICT Information Communication Technology
IP Internet Protocol
IPTV Internet Protocol TeleVision
ITU-T International Telecommunication Union - Telecommunication standardisation sector
MTBF Mean Time Between Failures
NAS Network Attached Storage
PLT Power Lines Technologies
PS Power Supply
PVC PolyVinyl Chloride
QLN Quiet Line Noise
USB Universal Serial Bus