Abstract

Energy consumption and efficiencies of telecommunications networks and customer premises equipment implementing Directive 2005/32/EC

Status
Not Published
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
23-Aug-2010
Due Date
11-Oct-2010
Completion Date
08-Sep-2010

Buy Documents

Standard

es_20287401v010101p - Access, Terminals, Transmission and Multiplexing (ATTM); External Common Power Supply for Customer Premises Network and Access Equipment; Part 1: Functional requirements

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI ES 202 874-1 V1.1.1 (2010-08) - Access, Terminals, Transmission and Multiplexing (ATTM); External Common Power Supply for Customer Premises Network and Access Equipment; Part 1: Functional requirements

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview

kSIST prES 202 874-1 V1.1.1:2010 from SIST is a standard for Access, Terminals, Transmission and Multiplexing (ATTM) external common power supplies for customer premises network and access equipment. It specifies the functional requirements for a Common Power Supply (CPS) used with home network equipment, including operating conditions, energy efficiency, connectors and eco-design. The document is aimed at Customer Premises Equipment (CPE) such as home gateways, home network infrastructure devices and some end devices.

What does kSIST prES 202 874-1 V1.1.1:2010 specify?

kSIST prES 202 874-1 V1.1.1:2010 defines a universal CPS concept for home-network use, powered from AC mains and intended to work with several device families. It covers what the CPS must do, what it must withstand, and how it should be organized into categories so that devices and service providers can reuse one supply across different products.

The document is organized into:

  • Scope and purpose
  • References
  • Definitions and abbreviations
  • Market scenarios and use cases
  • CPS operating conditions
  • CPS energy efficiency
  • CPS connectors
  • CPS eco-design
  • Annex A with bibliography

Clause 1 limits the scope to mains-powered CPS units for customer equipment in the home environment. It explicitly excludes other power methods such as Power Over Ethernet and power on USB. The introduction also points to companion parts for implementation details of the different CPS types.

What are the key requirements of kSIST prES 202 874-1 V1.1.1:2010?

The core of kSIST prES 202 874-1 V1.1.1:2010 is a set of requirements for voltage, current, efficiency, safety, reliability, connectors and recyclability. In practice, this is the part a designer, buyer or test lab needs to check first.

Operating conditions and output categories

Clauses 5 and 6 define the electrical and environmental envelope. The CPS must accept 100 V to 240 V AC, with allowed variation from 90 V to 264 V and 47 Hz to 63 Hz, and it must keep DC output within ±5 % of nominal at the load end of the output connectors.

The document defines four categories:

  • Type 1 - 5 V, 2 A
  • Type 2.a - 12 V, 1 A
  • Type 2.b - 12 V, 2 A
  • Type 2.c - 12 V, 5 A

That matters because the supply has to match both the device load and the power level expected by the intended application.

EMC, coexistence and protection

Clause 5 requires compliance with the harmonised safety and EMC standards listed in the references, plus compatibility with xDSL use and with powerline communications (PLT). The CPS must not introduce significant interference to xDSL modem operation, its conducted emissions on the AC power port are limited for the PLT band, and it must not reduce PLT throughput by more than 5 % of the reference value.

The common-mode leakage current from primary to secondary side must stay below 10 μA. In practice, this protects voice and data services and helps avoid troubleshooting problems in mixed home networks.

Reliability and environment

Clause 5 also sets lifetime and durability expectations. The CPS must be designed for 10 years of continual operation at maximum output power and a minimum MTBF of 300 000 hours. It must also operate, store and transport within the stated temperature and humidity classes.

That matters for service providers that want to reuse a CPS across generations of equipment without replacing it early.

Energy efficiency and testing

Clause 6 ties the CPS to regional efficiency obligations and sets type-specific efficiency targets. It also requires testing by the US EPA Energy Star method, with additional reporting at no-load and at 10 %, 25 %, 50 %, 75 % and 100 % of full rated output current.

That gives buyers and test labs a common way to compare supplies and verify declared efficiency.

Connectors and eco-design

Clauses 7 and 8 require each CPS variant to use a unique connector type that prevents connection to the wrong device. They also require recyclable plastic for the external case, encourage recycled plastic and alternatives to PVC, and require a design that allows separation of plastic and electronics at end of life.

What terms does kSIST prES 202 874-1 V1.1.1:2010 define?

  • Common Power Supply (CPS) - A shared external power supply for customer network and access equipment.
  • Customer Network (CN) - The in-house network made up of gateways, end devices, network segments and infrastructure devices.
  • Customer Network Gateway (CNG) - The gateway between the home network and the access network, also called Home Gateway (HG) or Small Business Gateway (SBG).
  • Customer Network Device (CND) - A physical device that enables use of services, also called End Device (ED).
  • Broadband Service Provider (BSP) - The provider that may manage or supply the equipment and the CPS.
  • MTBF - Mean Time Between Failures, used here as a reliability measure for long-life reuse.
  • PLT - Powerline communications using the mains wiring as the data medium.
  • HGI - Home Gateway Initiative, the industry group whose work underpins the requirements.

Who uses kSIST prES 202 874-1 V1.1.1:2010?

kSIST prES 202 874-1 V1.1.1:2010 is used by Broadband Service Providers, home gateway and HNID manufacturers, power supply designers, and silicon vendors involved in customer-premises networking equipment. It is also relevant to test laboratories and compliance teams that verify safety, EMC, energy efficiency, PLT coexistence and environmental durability.

It is especially useful where one CPS is meant to serve several device types, such as gateways, set-top boxes, telephones, access points, hubs, switches and similar home-network equipment.

Which standards are used with kSIST prES 202 874-1 V1.1.1:2010?

The standard relies on a set of referenced documents for compliance and test context:

  • HGI-RD001-R2 - residential profile used for the Type 2.b context
  • Commission Regulation (EC) No 278/2009, Energy Star, Public Law 110-140, and the US EPA test method - energy efficiency and external power supply requirements
  • EN 60950-1, EN 55022, EN 55024, EN 61000-4-2, EN 61000-4-5, EN 61000-4-11, EN 61000-3-2, and CISPR 22 - safety and EMC
  • IEEE 1413 - reliability prediction
  • EN 300 019-1-1, EN 300 019-1-2, EN 300 019-1-3 - environmental conditions and transport/storage classes
  • ITU-T G.992.3 and ITU-T K.21 - xDSL operation and customer-premises protection
  • ETSI TS 102 874-2, -3, -4, -5 - implementation details for the CPS types

What does the kSIST prES 202 874-1 V1.1.1:2010 document contain?

The document contains the market background that led to the CPS concept, including device scenarios and the reasons for standardizing output levels and connectors. It gives a category table for the four CPS types, figures showing power-supply configurations, and notes on coexistence with PLT.

It also includes detailed requirements R1 to R33, covering electrical limits, EMC, xDSL and PLT behaviour, lifetime, storage and transport conditions, efficiency targets, connector uniqueness and eco-design. Annex A provides a bibliography for related work and supporting references.

Buy Documents

Standard

es_20287401v010101p - Access, Terminals, Transmission and Multiplexing (ATTM); External Common Power Supply for Customer Premises Network and Access Equipment; Part 1: Functional requirements

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI ES 202 874-1 V1.1.1 (2010-08) - Access, Terminals, Transmission and Multiplexing (ATTM); External Common Power Supply for Customer Premises Network and Access Equipment; Part 1: Functional requirements

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

kSIST prES 202 874-1 V1.1.1:2010 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Access, Terminals, Transmission and Multiplexing (ATTM) - External Common Power Supply for Customer Premises Network and Access Equipment - Part 1: Functional requirements". This standard covers: Energy consumption and efficiencies of telecommunications networks and customer premises equipment implementing Directive 2005/32/EC

Energy consumption and efficiencies of telecommunications networks and customer premises equipment implementing Directive 2005/32/EC

kSIST prES 202 874-1 V1.1.1:2010 is classified under the following ICS (International Classification for Standards) categories: 33.060.40 - Cabled distribution systems. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST prES 202 874-1 V1.1.1:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


ETSI Standard
Access, Terminals, Transmission and Multiplexing (ATTM);
External Common Power Supply for
Customer Premises Network and Access Equipment;
Part 1: Functional requirements

2 ETSI ES 202 874-1 V1.1.1 (2010-10)

Reference
DES/ATTM-02011
Keywords
power supply
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2010.
All rights reserved.
TM TM TM TM
DECT , PLUGTESTS , UMTS , TIPHON , the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered
for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
LTE™ is a Trade Mark of ETSI currently being registered
for the benefit of its Members and of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 ETSI ES 202 874-1 V1.1.1 (2010-10)

Contents
Intellectual Property Rights . 4
Foreword . 4
Introduction . 4
1 Scope and Purpose . 6
1.1 Scope . 6
1.2 Applicability . 6
1.3 Requirements Notation . 6
2 References . 7
2.1 Normative references . 7
2.2 Informative references . 8
3 Definitions and abbreviations . 9
3.1 Definitions . 9
3.2 Abbreviations . 9
4 Market scenarios and use cases . 10
4.1 The state of the art . 10
4.1.1 Market situation . 10
4.1.2 Power supply energy efficiency issues . 11
4.2 CPS categories . 11
4.2.1 Connectors . 12
4.2.2 Reliability and environmental conditions . 12
4.3 The usage scenarios . 12
4.4 Usability issues and CPS elements . 12
4.5 Coexistence with Powerline communications . 13
5 Requirements for CPS operating conditions . 15
5.1 EMC and safety requirements . 16
5.2 Reliability . 17
5.3 Protection . 17
5.4 Environmental conditions . 17
6 Requirements for CPS energy efficiency . 17
6.1 Efficiency targets . 17
6.2 Efficiency measurement method . 18
7 Requirements for CPS connectors . 18
8 Requirements for CPS eco-design . 18
Annex A (informative): Bibliography . 19
History . 20

ETSI
4 ETSI ES 202 874-1 V1.1.1 (2010-10)

Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This ETSI Standard (ES) has been produced by ETSI Technical Committee Access, Terminals, Transmission and
Multiplexing (ATTM).
The present document is part 1 of a multi-part deliverable covering the External Common Power Supply (CPS) for
Customer Premises Network and Access Equipment, as identified below:
ES 202 874-1: "Functional requirements";
TS 102 874-2: "Integrated Broadband Cable and Television Networks";
TS 102 874-3: "CPS Type 1 implementation details";
TS 102 874-4: "Part 4: CPS Type 2.b implementation details";
TS 102 874-5: "CPS Type 2.c implementation".
Introduction
The present document addresses the functional requirements and implementation and operational aspects of the
External Common Power Supply (CPS) for Customer Premises Network and Access Equipment.
The multi-part deliverable represents a set of cohesive interwoven technical information that has jointly evolved to
define solution of most efficient equipment, as defined below:
• ES 202 874-1 defines functional requirements for four different categories of CPS.
• TS 102 874-2 [i.1] defines detailed implementation and operational aspects for CPS Type 2.a.
• TS 102 874-3 [i.2] defines detailed implementation and operational aspects for CPS Type 1.
• TS 102 874-4 [i.3] defines detailed implementation and operational aspects for CPS Type 2.b.
• TS 102 874-5 [i.4]: defines detailed implementation and operational aspects for CPS Type 2.c.
The intended applications of these CPS categories are specified in the present document.
ETSI
5 ETSI ES 202 874-1 V1.1.1 (2010-10)

Table 1 summarises the structure of the present document.
Table 1
CPS category Functional requirements Implementation aspects
Type 1: 5V, 2A TS 102 874-3 [i.2]

Type 2.a: 12V, 1A TS 102 874-2 [i.1]
ES 202 874-1
Type 2.b: 12V, 2A TS 102 874-4 [i.3]
Type 2.c: 12V, 5A TS 102 874-5 [i.4]

The present document is describing functional requirements applicable to an external common power supply (CPS)
converting and adapting AC mains to DC power for customer premises network equipment. Other methods for
providing power to end devices are not in the scope of the document (e.g. Power Over Ethernet, power on USB etc.).
The requirements were defined on the basis of HGI (Home Gateway Initiative) activity on the same subject contained in
the public document HGI-RD015-R3 [i.5]. That is the result of collaborative efforts of HGI members that include
Broadband Service Providers (BSPs), gateway manufacturers, and silicon vendors.
The present document is defining operating conditions, energy efficiency and ecodesign aspects for a number of
categories of power supplies, depending on market applicability and power needs of the targeted Customer Premises
Equipment (CPEs). Additional Technical Specifications will address the implementation aspects for each of the CPS
categories here defined, including the choice of connectors.
The need for standardization activities in energy efficiency and ecodesign related to telecommunications is now widely
seen. For example the European Union, in the "ICT 2009 Standardization Work Programme" [i.6] highlights this need.
Enabling the use of standardized power supplies, or the development of a new Common Power Supply (CPS) for DSL
modems, home gateways, optical network terminations is a key aspect of telecommunications standardization that will
contribute to ecodesign.
The expected timeline for adoption of the present document is as follows:
• Initial, partial deployments prior to 2011 depending on availability of specific TSs.
• Universal deployments for customer premises equipment within service providers' networks (i.e. within those
service providers mandating these requirements) starting from 2011.
ETSI
6 ETSI ES 202 874-1 V1.1.1 (2010-10)

1 Scope and Purpose
1.1 Scope
The present document specifies a universal solution for power supplies (named Common Power Supply and indicated
with the acronym CPS) suitable for customer equipment used in the home networks, using energy provided by mains
power in a range between 100 V and 240 V AC and 50 Hz to 60 Hz of frequency (apart tolerances). The topics
addressed in the present document are as follows:
• applicability: definition of product categories included in the scope (home gateway, and various other devices
installed in the home network);
• market scenarios and use cases for the use of the CPS in the home environment;
• functional requirements for electrical operating conditions of the CPS;
• functional requirements for energy efficiency of the CPS;
• functional requirements for connectors on the CPS and devices which it powers;
• functional requirements for eco-design of the CPS.
1.2 Applicability
Customer Network Gateway (CNG) Power Supply
Customer Network Gateways, also called Home gateways, currently use external power supplies ("bricks") that provide
different ranges of output voltage and current.
Furthermore, the connectors on the HG which attach to the power supply, and the corresponding connectors on the
cable frequently differ, not only between HGs of different vendors, but also between different HG models from the
same vendor. A suitable output voltage and current, along with connector type would have to be specified to create a
truly "universal" solution applicable to all home gateways.
Home Network Infrastructure Devices (HNIDs) Power Supply
In addition to home gateways, other home network infrastructure devices (HNIDs) may use a power supply with similar
features in terms of voltage and current, so that a common solution could be defined for both types of device.
These HNID devices may have a similar specification and distribution process, in other words they are managed and/or
supplied by a common BSP. Therefore, the extension of the CPS solution defined for HGs to HNIDs has also been
considered.
End Device Power Supply
Some end user devices use power supplies with similar characteristics to those of CNGs (e.g. some set top boxes,
cordless phones and IP phones).
The requirements contained in the present document apply to all the above mentioned categories.
1.3 Requirements Notation
If the present document is implemented, the key words "MUST" and "SHALL" as well as "REQUIRED" are to be
interpreted as indicating a mandatory aspect of the present document. The keywords indicating a certain level of
significance of a particular requirement that are used throughout the present document are summarized below.
MUST: This word or the adjective "REQUIRED" means that the item is an absolute requirement of the present
document.
MUST NOT: This phrase means that the item is an absolute prohibition of the present document.
ETSI
7 ETSI ES 202 874-1 V1.1.1 (2010-10)

SHOULD: This word or the adjective "RECOMMENDED" means that there may exist valid reasons in particular
circumstances to ignore this item, but the full implications should be understood and the case carefully weighed before
choosing a different course.
SHOULD NOT: This phrase means that there may exist valid reasons in particular circumstances when the listed
behaviour is acceptable or even useful, but the full implications should be understood and the case carefully weighed
before implementing any behaviour described with this label.
MAY: This word or the adjective "OPTIONAL" means that this item is truly optional. One vendor may choose to
include the item because a particular marketplace requires it or because it enhances the product, for example; another
vendor may omit the same item.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] Home Gateway Initiative HGI-RD001-R2 (2008): "Technical Requirements: Residential Profile
V1.0".
NOTE: Available at: http://www.homegatewayinitiative.org/publis/HGI_V1.01_Residential.pdf.
[2] Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC
of the European Parliament and of the Council with regard to ecodesign requirements for no-load
condition electric power consumption and average active efficiency of external power supplies. ®
[3] Energy Star : "Program Requirements for Single Voltage External Ac-Dc and Ac-Ac Power
Supplies - Eligibility Criteria (Version 2.0)".
[4] Public Law 110-140 (19 December 2007): "Energy Independence And Security Act Of 2007".
[5] United States Environmental Protection Agency (US EPA) (11 August 2004): "Test Method for
Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac Power Supplies".
[6] CENELEC EN 60950-1 (2006): "Information technology equipment - Safety - Part 1: General
requirements".
[7] CENELEC EN 55022 (2006) and Amendment 1 (2007): "Information technology equipment -
Radio disturbance characteristics - Limits and methods of measurement".
[8] CENELEC EN 55024 (1998), Amendment 1 (2001) and Amendment 2 (2003): "Information
technology equipment - Immunity characteristics - Limits and methods of measurement".
[9] IEEE 1413 (2010): "Standard Framework for Reliability Prediction of Hardware".
[10] ETSI EN 300 019-1-1: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
ETSI
8 ETSI ES 202 874-1 V1.1.1 (2010-10)

[11] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weather protected locations".
[12] ETSI EN 300 019-1-2: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-2: Classification of Environmental
Conditions; Transportation".
[13] ITU-T Recommendation G.992.3: "Asymmetric digital subscriber line transceivers 2 (ADSL2)".
[14] ITU-T Recommendation K.21: "Resistibility of telecommunication equipment installed in
customer premises to overvoltages and overcurrents".
[15] CISPR 22: "Information technology equipment - radio disturbance characteristics - limits and
methods of measurement".
[16] CENELEC EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[17] CENELEC EN 61000-4-2: "Electromagnetic compatibility (EMC) - Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[18] CENELEC EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4-5: Testing and
measurement techniques - Surge immunity test".
[19] CENELEC EN 61000-3-2: "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current <= 16 A per phase)".
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI TS 102 874-2: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 2: Integrated
Broadband Cable and Television Networks".
[i.2] ETSI TS 102 874-3: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 3: CPS
Type 1 implementation details".
[i.3] ETSI TS 102 874-4: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 4: CPS
Type 2.b implementation details".
[i.4] ETSI TS 102 874-5: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 5: CPS
Type 2.c implementation".
[i.5] Home Gateway Initiative HGI-RD015-R3: "Energy Efficiency and Ecodesign requirements for a
common power supply (CPS) for home gateway, home networking equipment and end devices".
[i.6] European Commission: "ICT 2009 Standardization Work Programme".
NOTE: Available at: http://ec.europa.eu/enterprise/sectors/ict/files/wp2009_en.pdf.
ETSI
9 ETSI ES 202 874-1 V1.1.1 (2010-10)

3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
Customer Network (CN): in-house network composed by home gateway, end devices, network segments (physical
wired or wireless connections between customer network elements), home network infrastructure devices such as
network adapters (performing a L1/L2 conversion between different network segments) and nodes (network adapters
with L3 routing capabilities)
NOTE: Also called Home Network (HN) or Customer Premises Network (CPN).
Customer Network Gateway (CNG): gateway between the HN and the Access Network able to perform networking
functions from physical connection to bridging and routing capabilities, but also possibly implementing functions
related to the service support
NOTE: Also called Home Gateway (HG) or Small Business Gateway (SBG).
Customer Network Device (CND): physical device enabling service(s) usage
NOTE 1: Also called End Device (ED).
NOTE 2: EDs can be dedicated to the internet, conversational and audio-video services. But they could be also
Consumer Electronics equipment and other devices which may have nothing to do with these premium
services (e.g. services performing a content sharing within a HN, typically between a PC and a music
system, through the HG).
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AC Alternating Current
ADSL Asymmetric Digital Subscriber Line
BSP Broadband Service Provider
CE Comission Européenne
NOTE: "CE" is the European symbol for products' compliance to safety and EMC directives.
CND Customer Network Device
CNG Customer Network Gateway
CPE Customer Premises Equipment
CPN Customer Premises Network
CPS Common Power Supply
DC Direct Current
DSL Digital Subscriber Line
ED End Device
EMC ElectroMagnetic Compatibility
EuP Energy-using products
HG Home Gateway
HGI Home Gateway Initiative
HNID Home Network Infrastructure Device
ITU-T International Telecommunication Union - Telecommunication standardisation sector
MTBF Mean Time Between Failures
NAS Network Attached Storage
PLT PowerLines Technologies
PSU Power Supply Unit
PVC PolyVinyl Chloride
QLN Quiet Line Noise
SDO Standards Development Organization
ETSI
...


Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)
ETSI Standard
Access, Terminals, Transmission and Multiplexing (ATTM);
External Common Power Supply for
Customer Premises Network and Access Equipment;
Part 1: Functional requirements

2 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

Reference
DES/ATTM-02011
Keywords
power supply
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2010.
All rights reserved.
TM TM TM TM
DECT , PLUGTESTS , UMTS , TIPHON , the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered
for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
LTE™ is a Trade Mark of ETSI currently being registered
for the benefit of its Members and of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

Contents
Intellectual Property Rights . 4
Foreword . 4
Introduction . 4
1 Scope and Purpose . 6
1.1 Scope . 6
1.2 Applicability . 6
1.3 Requirements Notation . 6
2 References . 7
2.1 Normative references . 7
2.2 Informative references . 8
3 Definitions and abbreviations . 9
3.1 Definitions . 9
3.2 Abbreviations . 9
4 Market scenarios and use cases . 10
4.1 The state of the art . 10
4.1.1 Market situation . 10
4.1.2 Power supply energy efficiency issues . 11
4.2 CPS categories . 11
4.2.1 Connectors . 12
4.2.2 Reliability and environmental conditions . 12
4.3 The usage scenarios . 12
4.4 Usability issues and CPS elements . 12
4.5 Coexistence with Powerline communications . 13
5 Requirements for CPS operating conditions . 15
5.1 EMC and safety requirements . 16
5.2 Reliability . 17
5.3 Protection . 17
5.4 Environmental conditions . 17
6 Requirements for CPS energy efficiency . 17
6.1 Efficiency targets . 17
6.2 Efficiency measurement method . 18
7 Requirements for CPS connectors . 18
8 Requirements for CPS eco-design . 18
Annex A (informative): Bibliography . 19
History . 20

ETSI
4 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This ETSI Standard (ES) has been produced by ETSI Technical Committee Access, Terminals, Transmission and
Multiplexing (ATTM), and is now submitted for the ETSI standards Membership Approval Procedure.
The present document is part 1 of a multi-part deliverable covering the External Common Power Supply (CPS) for
Customer Premises Network and Access Equipment, as identified below:
ES 202 874-1: "Functional requirements";
TS 102 874-2: "Integrated Broadband Cable and Television Networks";
TS 102 874-3: "CPS Type 1 implementation details";
TS 102 874-4: "Part 4: CPS Type 2.b implementation details";
TS 102 874-5: "CPS Type 2.c implementation".
Introduction
The present document addresses the functional requirements and implementation and operational aspects of the
External Common Power Supply (CPS) for Customer Premises Network and Access Equipment.
The multi-part deliverable represents a set of cohesive interwoven technical information that has jointly evolved to
define solution of most efficient equipment, as defined below:
• ES 202 874-1 defines functional requirements for four different categories of CPS.
• TS 102 874-2 [i.1] defines detailed implementation and operational aspects for CPS Type 2.a.
• TS 102 874-3 [i.2] defines detailed implementation and operational aspects for CPS Type 1.
• TS 102 874-4 [i.3] defines detailed implementation and operational aspects for CPS Type 2.b.
• TS 102 874-5 [i.4]: defines detailed implementation and operational aspects for CPS Type 2.c.
The intended applications of these CPS categories are specified in the present document.
Table 1 summarises the structure of the present document.
ETSI
5 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

Table 1
CPS category Functional requirements Implementation aspects
Type 1: 5V, 2A TS 102 874-3 [i.2]
Type 2.a: 12V, 1A TS 102 874-2 [i.1]
ES 202 874-1
Type 2.b: 12V, 2A TS 102 874-4 [i.3]
Type 2.c: 12V, 5A TS 102 874-5 [i.4]

The present document is describing functional requirements applicable to an external common power supply (CPS)
converting and adapting AC mains to DC power for customer premises network equipment. Other methods for
providing power to end devices are not in the scope of the document (e.g. Power Over Ethernet, power on USB, etc.).
The requirements were defined on the basis of HGI (Home Gateway Initiative) activity on the same subject contained in
the public document HGI-RD015-R3 [i.5]. That is the result of collaborative efforts of HGI members that include
Broadband Service Providers (BSPs), gateway manufacturers, and silicon vendors.
The present document is defining operating conditions, energy efficiency and ecodesign aspects for a number of
categories of power supplies, depending on market applicability and power needs of the targeted Customer Premises
Equipment (CPEs). Additional Technical Specifications will address the implementation aspects for each of the CPS
categories here defined, including the choice of connectors.
The need for standardization activities in energy efficiency and ecodesign related to telecommunications is now widely
seen. For example the European Union, in the "ICT 2009 Standardization Work Programme" [i.6] highlights this need.
Enabling the use of standardized power supplies, or the development of a new Common Power Supply (CPS) for DSL
modems, home gateways, optical network terminations is a key aspect of telecommunications standardization that will
contribute to ecodesign.
The expected timeline for adoption of the present document is as follows:
• Initial, partial deployments prior to 2011 depending on availability of specific TSs.
• Universal deployments for customer premises equipment within service providers' networks (i.e. within those
service providers mandating these requirements) starting from 2011.
ETSI
6 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

1 Scope and Purpose
1.1 Scope
The present document specifies a universal solution for power supplies (named Common Power Supply and indicated
with the acronym CPS) suitable for customer equipment used in the home networks, using energy provided by mains
power in a range between 100 V and 240 V AC and 50 Hz to 60 Hz of frequency (apart tolerances). The topics
addressed in the present document are as follows:
• applicability: definition of product categories included in the scope (home gateway, and various other devices
installed in the home network);
• market scenarios and use cases for the use of the CPS in the home environment;
• functional requirements for electrical operating conditions of the CPS;
• functional requirements for energy efficiency of the CPS;
• functional requirements for connectors on the CPS and devices which it powers;
• functional requirements for eco-design of the CPS.
1.2 Applicability
Customer Network Gateway (CNG) Power Supply
Customer Network Gateways, also called Home gateways, currently use external power supplies ("bricks") that provide
different ranges of output voltage and current.
Furthermore, the connectors on the HG which attach to the power supply, and the corresponding connectors on the
cable frequently differ, not only between HGs of different vendors, but also between different HG models from the
same vendor. A suitable output voltage and current, along with connector type would have to be specified to create a
truly "universal" solution applicable to all home gateways.
Home Network Infrastructure Devices (HNIDs) Power Supply
In addition to home gateways, other home network infrastructure devices (HNIDs) may use a power supply with similar
features in terms of voltage and current, so that a common solution could be defined for both types of device.
These HNID devices may have a similar specification and distribution process, in other words they are managed and/or
supplied by a common BSP. Therefore, the extension of the CPS solution defined for HGs to HNIDs has also been
considered.
End Device Power Supply
Some end user devices use power supplies with similar characteristics to those of CNGs (e.g. some set top boxes,
cordless phones and IP phones).
The requirements contained in the present document apply to all the above mentioned categories.
1.3 Requirements Notation
If the present document is implemented, the key words "MUST" and "SHALL" as well as "REQUIRED" are to be
interpreted as indicating a mandatory aspect of the present document. The keywords indicating a certain level of
significance of a particular requirement that are used throughout the present document are summarized below.
MUST: This word or the adjective "REQUIRED" means that the item is an absolute requirement of the present
document.
MUST NOT: This phrase means that the item is an absolute prohibition of the present document.
ETSI
7 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

SHOULD: This word or the adjective "RECOMMENDED" means that there may exist valid reasons in particular
circumstances to ignore this item, but the full implications should be understood and the case carefully weighed before
choosing a different course.
SHOULD NOT: This phrase means that there may exist valid reasons in particular circumstances when the listed
behaviour is acceptable or even useful, but the full implications should be understood and the case carefully weighed
before implementing any behaviour described with this label.
MAY: This word or the adjective "OPTIONAL" means that this item is truly optional. One vendor may choose to
include the item because a particular marketplace requires it or because it enhances the product, for example; another
vendor may omit the same item.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] Home Gateway Initiative HGI-RD001-R2 (2008): "Technical Requirements: Residential Profile
V1.0".
NOTE: Available at: http://www.homegatewayinitiative.org/publis/HGI_V1.01_Residential.pdf.
[2] Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC
of the European Parliament and of the Council with regard to ecodesign requirements for no-load
condition electric power consumption and average active efficiency of external power supplies. ®
[3] Energy Star : "Program Requirements for Single Voltage External Ac-Dc and Ac-Ac Power
Supplies - Eligibility Criteria (Version 2.0)".
[4] Public Law 110-140 (19 December 2007): "Energy Independence And Security Act Of 2007".
[5] United States Environmental Protection Agency (US EPA) (11 August 2004): "Test Method for
Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac Power Supplies".
[6] CENELEC EN 60950-1 (2006): " Information technology equipment - Safety - Part 1: General
requirements".
[7] CENELEC EN 55022 (2006) and Amendment 1 (2007): " Information technology equipment -
Radio disturbance characteristics - Limits and methods of measurement".
[8] CENELEC EN 55024 (1998), Amendment 1 (2001) and Amendment 2 (2003): "Information
technology equipment - Immunity characteristics - Limits and methods of measurement".
[9] IEEE 1413 (2010): "Standard Framework for Reliability Prediction of Hardware".
[10] ETSI EN 300 019-1-1: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
ETSI
8 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

[11] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weather protected locations".
[12] ETSI EN 300 019-1-2: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-2: Classification of Environmental
Conditions; Transportation".
[13] ITU-T Recommendation G.992.3: "Asymmetric digital subscriber line transceivers 2 (ADSL2)".
[14] ITU-T Recommendation K.21: "Resistibility of telecommunication equipment installed in
customer premises to overvoltages and overcurrents".
[15] CISPR 22: "Information technology equipment - radio disturbance characteristics - limits and
methods of measurement".
[16] CENELEC EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[17] CENELEC EN 61000-4-2: "Electromagnetic compatibility (EMC) - Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[18] CENELEC EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4-5: Testing and
measurement techniques - Surge immunity test".
[19] CENELEC EN 61000-3-2: "Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current <= 16 A per phase)".
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI TS 102 874-2: "Access, Terminals, Transmission and Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 2: Integrated
Broadband Cable and Television Networks".
[i.2] ETSI TS 102 874-3: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 3: CPS
Type 1 implementation details".
[i.3] ETSI TS 102 874-4: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 4: CPS
Type 2.b implementation details".
[i.4] ETSI TS 102 874-5: "Access, Terminals & Transmission, Multiplexing (ATTM); External
Common Power Supply for Customer Premises Network and Access Equipment; Part 5: CPS
Type 2.c implementation".
[i.5] Home Gateway Initiative HGI-RD015-R3: "Energy Efficiency and Ecodesign requirements for a
common power supply (CPS) for home gateway, home networking equipment and end devices".
[i.6] European Commission: "ICT 2009 Standardization Work Programme".
NOTE: Available at: http://ec.europa.eu/enterprise/sectors/ict/files/wp2009_en.pdf.
ETSI
9 Final draft ETSI ES 202 874-1 V1.1.1 (2010-08)

3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
Customer Network (CN): in-house network composed by home gateway, end devices, network segments (physical
wired or wireless connections between customer network elements), home network infrastructure devices such as
network adapters (performing a L1/L2 conversion between different network segments) and nodes (network adapters
with L3 routing capabilities)
NOTE: Also called Home Network (HN) or Customer Premises Network (CPN).
Customer Network Gateway (CNG): gateway between the HN and the Access Network able to perform networking
functions from physical connection to bridging and routing capabilities, but also possibly implementing functions
related to the service support
NOTE: Also called Home Gateway (HG) or Small Business Gateway (SBG).
Customer Network Device (CND): physical device enabling service(s) usage
NOTE 1: Also called End Device (ED).
NOTE 2: EDs can be dedicated to the internet, conversational and audio-video services. But they could be also
Consumer Electronics equipment and other devices which may have nothing to do with these premium
services (e.g. services performing a content sharing within a HN, typically between a PC and a music
system, through the HG).
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AC Alternating Current
ADSL Asymmetric Digital Subscriber Line
BSP Broadband Service Provider
CE Comission Européenne
NOTE: "CE" is the European symbol for products’ compliance to safety and EMC directives QLN Quiet Line
Noise.
CND Customer Network Device
CNG Customer Network Gateway
CPE Customer Premises Equipment
CPN Customer Premises Network
CPS Common Power Supply
DC Direct Current
DSL Digital Subscriber Line
ED End Device
EMC ElectroMagnetic Compatibility
EuP Energy-using products
HG Home Gateway
HGI Home Gateway Initiative
HNID Home Network Infrastructure Device
ITU-T International Telecommunication Union - Telecommunication standardisation sector
LAN Local Area Network
MTBF Mean Time Between Failures
NAS Network Attached Storage
NT Network Termination
PLT PowerLines Technologies
PSU Power Supply Unit
PVC PolyVinyl Chloride
ETSI
...