SIST EN 61243-2:2000/A1:2000
(Amendment)Live working - Voltage detectors -- Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.
Live working - Voltage detectors -- Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.
EN following parallel vote
Arbeiten unter Spannung - Spannungsprüfer -- Teil 2: Resistive (ohmsche) Ausführungen für Wechselspannungen von 1 kV bis 36 kV
Travaux sous tension - Détecteurs de tension -- Partie 2: Type résistif pour usage sur des tensions alternatives de 1 kV à 36 kV
Delo pod napetostjo - Indikatorji napetosti - 2. del: Uporovni tip za uporabo na napetostih od 1 kV do 36 kV izmenično (IEC 61243-2:1995/A1:1999)
General Information
- Status
- Published
- Publication Date
- 31-May-2000
- Technical Committee
- DPN - Live Working
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jun-2000
- Due Date
- 01-Jun-2000
- Completion Date
- 01-Jun-2000
Relations
- Effective Date
- 01-Jun-2000
Overview
EN 61243-2:1997/A1:2000 (CLC) is the European adoption/amendment of IEC 61243-2 and specifies requirements for resistive (ohmic) voltage detectors intended for live working on a.c. systems from 1 kV to 36 kV. The amendment (A1:2000) updates test methods and mechanical requirements to ensure reliable indication and mechanical robustness of voltage detectors used by personnel working on or near live high-voltage equipment.
Key Topics and Requirements
- Scope and type
- Applies to resistive-type voltage detectors for a.c. voltages between 1 kV and 36 kV used in live working.
- Magnetic interference test
- Requires a defined test setup using a straight conductor (25 mm ± 5 mm diameter, 2 m length with no magnetic material within 1 m).
- An a.c. current source produces 1 000 A in the conductor while the detector is positioned 50 mm from the conductor surface and aligned with its centre.
- The detector’s “voltage present” indication is measured before and during the 1 000 A field; the second measurement must not deviate by more than 5%.
- Tests are repeated with the detector rotated 90° and with current and voltage sources in phase and 120° out of phase.
- Earth lead robustness
- Detailed mechanical test setup: detector fastened to oscillate about a centre 20 mm above the earth lead emergence; emergence angle ~50°.
- Dynamic tests: a 10 N load applied 200 mm below emergence; 10 000 oscillations through ±45° with a period of 0.5–1.0 s in vertical and horizontal planes.
- Static tests: load increased to 200 N for 1 minute with the lead vertical; clip/clamp must remain attached when a 200 N load is applied.
- Pass criteria: no visible damage and clip/clamp integrity.
- Editorial changes
- Certain subclauses (e.g., other mechanical tests on earth lead) were removed or revised in the amendment.
Applications and Users
- Practical use: ensures safe, reliable voltage detection for live-line operations and maintenance on overhead lines, substations and high-voltage equipment.
- Primary users:
- Utility and transmission line live-working teams
- Electrical safety officers and inspectors
- Manufacturers of voltage detectors and PPE
- Test laboratories and conformity assessment bodies
- Standards committees and procurement teams specifying safety equipment
Related Standards
- This document is an amendment to EN 61243-2 and is aligned with IEC 61243-2 (1995/A1:1999). Users should consider other parts of the IEC/EN 61243 series and relevant live working and electrical safety standards when specifying or testing voltage detectors.
Keywords: EN 61243-2:1997/A1:2000, voltage detectors, resistive type, live working, 1 kV to 36 kV, magnetic interference, earth lead robustness, IEC 61243-2, CLC.
Frequently Asked Questions
SIST EN 61243-2:2000/A1:2000 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Live working - Voltage detectors -- Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.". This standard covers: EN following parallel vote
EN following parallel vote
SIST EN 61243-2:2000/A1:2000 is classified under the following ICS (International Classification for Standards) categories: 13.260 - Protection against electric shock. Live working. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61243-2:2000/A1:2000 has the following relationships with other standards: It is inter standard links to SIST EN 61243-2:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST EN 61243-2:2000/A1:2000 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2000
'HORSRGQDSHWRVWMR1DSHWRVWQLGHWHNWRUMLGHO8SRURYQLWLS]DXSRUDERQD
QDSHWRVWLKRGN9GRN9L]PHQLþQR,(&$
Live working - Voltage detectors -- Part 2: Resistive type to be used for voltages of 1 kV
to 36 kV a.c.
Arbeiten unter Spannung - Spannungsprüfer -- Teil 2: Resistive (ohmsche)
Ausführungen für Wechselspannungen von 1 kV bis 36 kV
Travaux sous tension - Détecteurs de tension -- Partie 2: Type résistif pour usage sur
des tensions alternatives de 1 kV à 36 kV
Ta slovenski standard je istoveten z: EN 61243-2:1997/A1:2000
ICS:
13.260 9DUVWYRSUHGHOHNWULþQLP Protection against electric
XGDURP'HORSRGQDSHWRVWMR shock. Live working
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME CEI
INTERNATIONALE IEC
61243-2
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
1999-10
Amendement 1
Travaux sous tension – Détecteurs de tension –
Partie 2:
Type résistif pour usage sur des tensions
alternatives de 1 kV à 36 kV
Amendment 1
Live working – Voltage detectors –
Part 2:
Resistive type to be used for voltages
of 1 kV to 36 kV a.c.
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
E
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
61243-2 Amend. 1 © IEC:1999 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 78: Live working.
The text of this amendment is based on the following documents:
FDIS Report on voting
78/288/FDIS 78/294/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
___________
Page 31
5.2.2.3 Influence of interference voltage
Add, after 5.2.2.3, the following new subclause 5.2.2.4:
5.2.2.4 Influence of magnetic interference field
A straight conductor, 25 mm ± 5 mm in diameter, shall be arranged such that there is no
magnetic interference from external sources. This can be achieved by having a 2 m length of
conductor with no magnetic material within 1 m of the conductor.
The conductor shall be connected to an a.c. current source capable of producing 1 000 A, at
the nominal frequency, in the conductor (see figure 12a).
The detector shall be positioned parallel with the conductor. The centre of the indicator shall be
aligned with the centre of the conductor such that the surface of the indicator housing shall be
positioned 50 mm from the surface of the conductor (see figure 12a).
A voltage source separate from that of the current shall be connected between the contact
electrode of the detector and earth. The earth lead of the detector shall be connected to earth.
The test voltage shall be raised until the indication "voltage present" appears. A note of this
voltage shall be made. The test voltage shall then be reduced down to zero.
A current of 1 000 A shall then be passed through the conductor. The test voltage shall be
raised again until the indication "voltage present" appears. A note of this voltage shall be
made.
This part of the test shall be considered as passed if the second voltage measured does not
deviate by more than 5 % from the initial measurement.
The detector shall be turned through 90° such that the centre of t
...
SLOVENSKI STANDARD
01-junij-2000
Delo pod napetostjo - Indikatorji napetosti - 2. del: Uporovni tip za uporabo na
napetostih od 1 kV do 36 kV izmenično (IEC 61243-2:1995/A1:1999)
Live working - Voltage detectors -- Part 2: Resistive type to be used for voltages of 1 kV
to 36 kV a.c.
Arbeiten unter Spannung - Spannungsprüfer -- Teil 2: Resistive (ohmsche)
Ausführungen für Wechselspannungen von 1 kV bis 36 kV
Travaux sous tension - Détecteurs de tension -- Partie 2: Type résistif pour usage sur
des tensions alternatives de 1 kV à 36 kV
Ta slovenski standard je istoveten z: EN 61243-2:1997/A1:2000
ICS:
13.260 Varstvo pred električnim Protection against electric
udarom. Delo pod napetostjo shock. Live working
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME CEI
INTERNATIONALE IEC
61243-2
INTERNATIONAL
STANDARD
AMENDEMENT 1
AMENDMENT 1
1999-10
Amendement 1
Travaux sous tension – Détecteurs de tension –
Partie 2:
Type résistif pour usage sur des tensions
alternatives de 1 kV à 36 kV
Amendment 1
Live working – Voltage detectors –
Part 2:
Resistive type to be used for voltages
of 1 kV to 36 kV a.c.
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
E
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
61243-2 Amend. 1 © IEC:1999 – 3 –
FOREWORD
This amendment has been prepared by IEC technical committee 78: Live working.
The text of this amendment is based on the following documents:
FDIS Report on voting
78/288/FDIS 78/294/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
___________
Page 31
5.2.2.3 Influence of interference voltage
Add, after 5.2.2.3, the following new subclause 5.2.2.4:
5.2.2.4 Influence of magnetic interference field
A straight conductor, 25 mm ± 5 mm in diameter, shall be arranged such that there is no
magnetic interference from external sources. This can be achieved by having a 2 m length of
conductor with no magnetic material within 1 m of the conductor.
The conductor shall be connected to an a.c. current source capable of producing 1 000 A, at
the nominal frequency, in the conductor (see figure 12a).
The detector shall be positioned parallel with the conductor. The centre of the indicator shall be
aligned with the centre of the conductor such that the surface of the indicator housing shall be
positioned 50 mm from the surface of the conductor (see figure 12a).
A voltage source separate from that of the current shall be connected between the contact
electrode of the detector and earth. The earth lead of the detector shall be connected to earth.
The test voltage shall be raised until the indication "voltage present" appears. A note of this
voltage shall be made. The test voltage shall then be reduced down to zero.
A current of 1 000 A shall then be passed through the conductor. The test voltage shall be
raised again until the indication "voltage present" appears. A note of this voltage shall be
made.
This part of the test shall be considered as passed if the second voltage measured does not
de
...