LPG equipment and accessories - Essential operational dimensions for LPG cylinder valve outlet and associated equipment connections

This European Standard specifies basic dimensions of cylinder valves (manufactured in accordance with EN 13152 and EN 13153) and connectors (including regulators) to enable them to be connected together.
This European Standard lists connections where it may be possible to connect together, but which when connected may not be sound or secure in some operating conditions or orientations.
This European Standard also recommends tightening torques for the attachment of screwed metal-to-metal connections.
This European Standard contains the drawings, which describe direct cylinder valve connections in the following standards:
-   EN 12864,
-   EN 13785, and
-   EN 13786.
Quality assurance systems, production testing and particularly certificates of conformity are not covered in this standard.
This European Standard excludes connections for automotive vehicles covered by UN/ECE Regulation 67 and EN 13760 and excludes connections for cartridges.

Flüssiggas-Geräte und Ausrüstungsteile - Grundmaße für Ventilauslässe an Flüssiggas-(LPG-)Flaschen und zugehörige Verbindungen für Geräte

Diese Europäische Norm legt Grundmaße für Flüssiggas-(LPG)-Flaschenventile (hergestellt in Übereinstim-mung mit EN 13152 und EN 13153) und Anschlussstücke fest, um diese miteinander verbinden zu können.
Diese Europäische Norm enthält Anschlüsse, die möglicherweise mit einander verbunden werden können, aber unter einigen Betriebsbedingungen oder Ausrichtungen nicht dicht oder sicher sind.
Diese Europäische Norm enthält ebenfalls Empfehlungen zu Anschlussdrehmomenten für das Anbringen von Schraubverbindungen von Metall auf Metall.
Diese Europäische Norms Dokument enthält die Darstellungen, die direkte Flaschenventil-Verbindungen beschreiben, entsprechend:
-   EN 12864;
-   prEN 13785; und
-   EN 13786.
Qualitätssicherungssysteme, Fertigungsprüfung und besondere Konformitätsnachweise werden in diesem Dokument nicht behandelt.
Diese Europäische Norm gilt nicht für Verbindungen von Autogasfahrzeugen, die in UN/ECE Regulation 67 und EN 13760 geregelt sind und nicht für Anschlüsse von Kartuschen.

Equipements pour GPL et leurs accessoires - Dimensions opérationnelles essentielles des connexions des robinets et valves de bouteilles de GPL et des équipements associés

La présente Norme européenne spécifie les dimensions de base des robinets et valves de bouteilles (fabriqués conformément a l’EN 13152 et a l’EN 13153) et des matériels qui s’y connectent (y compris les détendeurs) afin de permettre leur raccordement.
La présente Norme européenne fournit la liste des connexions qu’il est possible de raccorder ensemble mais qui, une fois le raccordement effectué, sont susceptibles de ne plus etre saines ou sures dans certaines conditions d’utilisation ou d’orientation.
La présente Norme européenne recommande également des couples de serrage pour le montage des connexions métal/métal vissées.
La présente Norme européenne comporte les schémas qui décrivent les connexions directes des robinets et des valves de bouteilles dans les normes suivantes :
   l’EN 12864 ;
   l’EN 13785 ; et
   l’EN 13786.
La présente norme ne traite pas des systemes d’assurance qualité, des essais production, notamment des certificats de conformité.
La présente Norme européenne exclut les connexions des véhicules automobiles traités dans le Reglement 67 UN/ECE et dans l’EN 13760 ainsi que les connexions des cartouches

Oprema in pribor za utekočinjeni naftni plin (UNP) - Glavne mere izhodnega priključka ventila jeklenke za UNP ter pripadajoči pomožni priključki

General Information

Status
Withdrawn
Publication Date
31-Mar-2007
Withdrawal Date
08-Aug-2012
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
08-Aug-2012
Due Date
31-Aug-2012
Completion Date
09-Aug-2012

Relations

Buy Standard

Standard
EN 15202:2007
English language
43 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.L]KRGQHJDXþNLFlüssiggas-Geräte und Ausrüstungsteile - Grundmaße für Ventilauslässe an Flüssiggas-(LPG-)Flaschen und zugehörige Verbindungen für GeräteEquipements pour GPL et leurs accessoires - Dimensions opérationnelles essentielles des connexions des robinets et valves de bouteilles de GPL et des équipements associésLPG equipment and accessories - Essential operational dimensions for LPG cylinder valve outlet and associated equipment connections23.060.40Pressure regulators23.020.30MHNOHQNHPressure vessels, gas cylindersICS:Ta slovenski standard je istoveten z:EN 15202:2006SIST EN 15202:2007en01-april-2007SIST EN 15202:2007SLOVENSKI
STANDARD



SIST EN 15202:2007



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15202December 2006ICS 23.060.40 English VersionLPG equipment and accessories - Essential operationaldimensions for LPG cylinder valve outlet and associatedequipment connectionsEquipements pour GPL et leurs accessoires - Dimensionsopérationnelles essentielles des connexions des robinets etvalves de bouteilles de GPL et des équipements associésFlüssiggas-Geräte und Ausrüstungsteile - Grundmaße fürVentilauslässe an Flüssiggas-(LPG-)Flaschen undzugehörige Verbindungen für GeräteThis European Standard was approved by CEN on 21 October 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15202:2006: ESIST EN 15202:2007



EN 15202:2006 (E) 2 Contents Page Foreword.3 1 Scope.4 2 Normative references.4 3 Terms and definitions.5 4 Symbols and abbreviations.5 5 Design.5 6 Connections in use.38 7 Unsafe connections.38 8 Connecting torque.38 9 Marking.38 Annex A (informative)
Connections by country.39 Annex B (informative)
Unsafe connections.42 Bibliography.43
SIST EN 15202:2007



EN 15202:2006 (E) 3 Foreword This document (EN 15202:2006) has been prepared by Technical Committee CEN/TC 286 “Liquefied petroleum gas equipment and accessories”, the secretariat of which is held by NSAI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2007, and conflicting national standards shall be withdrawn at the latest by June 2007. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard : Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. SIST EN 15202:2007



EN 15202:2006 (E) 4 1 Scope This European Standard specifies basic dimensions of cylinder valves (manufactured in accordance with EN 13152 and EN 13153) and connectors (including regulators) to enable them to be connected together.
This European Standard lists connections where it may be possible to connect together, but which when connected may not be sound or secure in some operating conditions or orientations. This European Standard also recommends tightening torques for the attachment of screwed metal-to-metal connections. This European Standard contains the drawings, which describe direct cylinder valve connections in the following standards:  EN 12864,
 EN 13785, and  EN 13786. Quality assurance systems, production testing and particularly certificates of conformity are not covered in this standard. This European Standard excludes connections for automotive vehicles covered by UN/ECE Regulation 67 and EN 13760 and excludes connections for cartridges. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 549, Rubber materials for seals and diaphragms for gas appliances and gas equipment EN 560, Gas welding equipment – Hose connections for equipment for welding, cutting and allied processes EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) ISO 68-1, ISO general purpose screw threads — Basic profile — Part 1: Metric screw threads ISO 3601-1, Fluid power systems - O-rings - Part 1: Inside diameters, cross-sections, tolerances and size identification code DIN 477-1, Gas cylinder valves rated for test pressures up to 300 bar; types, sizes, and outlets ANSI/CGA V-1 American National, Compressed Gas Association Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections ANSI/ASME/B1.5, ACME Screw Threads issued by American Society of Mechanical Engineers 1990
SIST EN 15202:2007



EN 15202:2006 (E) 5 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 LPG (liquefied petroleum gas) mixture of predominantly butane or propane with traces of other hydrocarbon gases classified in accordance with UN number 1965, hydrocarbon gases mixture, liquefied, NOS or UN number 1075, petroleum gases, liquefied NOTE In some countries, UN numbers 1011 and 1978 may also be designated LPG. 3.2 connector device that attaches to a cylinder valve to allow the passage of LPG to or from the cylinder 3.3 valve operating mechanism mechanism that opens the valve when, or after, a regulator or connector is fitted and closes the valve automatically when, or before, a regulator or connector is disconnected 4 Symbols and abbreviations NBR Acrylonitrile-butadiene rubber (see ISO 4658). STP
Standard Temperature and Pressure [15,6 °C (288,7 K), 1,013 bar absolute (0,1013 MPa absolute)] IRHD, International Rubber Hardness Degrees. 5 Design The dimensions shall be in accordance with those given in the following figures.
The travel distance of the valve operating mechanisms is identified where required. The drawings show the location of sealing elements where required. Any hexagon nut with a left hand thread shall, for easy identification, have notches (for example a 60° V groove) at the corners. Where concentricity and surface finish are not specified, the requirements shall be as specified by the manufacturer. SIST EN 15202:2007



EN 15202:2006 (E) 6 Dimensions in millimetres
Key Connector/Nut Seal Thread 1 nut A1 ∅ 14,80 - ∅ 15 B1 ∅ 16,8 - ∅ 17 T1 ∅ 20 min. 2 connector A2 ∅ 10,5 - ∅ 10,6 B2 ∅ 10,2 - ∅ 10,4 T2 ∅ 18,838 – ∅ 19,973 3 seal A3 ∅ 17,4 - ∅17,5 B3 2,0 – 2,2 T3 ∅ 17,696 – ∅ 18,266 4 valve A4 4,8 – 5,2 NBR or equivalent T4 1,814 5 nut thread A5 2,9 – 3,1 EN 549
A2/H3 T5 55° 6 valve thread A6 14 min. Valve T6 R 0,249
A7 20 x 1,814 L.H. C1 20 x 1,814 L.H. T7 ∅ 19,589 – ∅ 19,98
A8 ∅ 15,15 - ∅15,26 C2 ∅ 14,3 – 14,7 T8 ∅ 18,703 – ∅ 18,838
A9 2,9 – 3,1 C3 ∅ 11,1 – 11,3 T9 ∅ 17,317 – ∅ 17,676
A10 11 min. C4 ∅ 6,8 - ∅ 7,2
A11 15,8 – 16,2 C5 R0,3 – R0,7
A12 25 A/F C6 6,0 – 6,3
A13 ∅ 8,4 max. C7 7,0 – 10,0
C8 11 min.
C9 0,5 x 90°
Figure 1 — Type G.1 - Threaded connection 20 x 1,814 LH - Spanner tightened SIST EN 15202:2007



EN 15202:2006 (E) 7 Dimensions in millimetres
Key Nut Connector Seal 1 nut A1 21,8 x 1,814 LH
B1 ∅ 18,5 – ∅ 18,7 C1 ∅ 17,7 - ∅ 18,0 2 connector A2 ∅ 16 max. B2 ∅ 12,2 – ∅ 12,3 C2 ∅ 10,7 - ∅ 11,0 3 seal A3 ∅ 24,6 min. B3 ∅ 11,1 – ∅ 11,3 C3 1,7 – 2,0 4 seal A4 7,5 min. B4 0,9 – 1,0 NBR or equivalent 5 valve
A5 7,5 – 8,1
B5 2,0 – 2,2 EN 549
A2/H3 6 nut thread A6 9,9 – 10,5 B6 2,4 – 2,6 Thread 7 valve thread A7 12,5 min. B7 ∅ 9,0 max. T1 ∅ 21,8 min.
A8 5 wings equally spaced B8 ∅ A2 –0,1–0,3 T2 ∅ 20,622 – ∅ 20,722
Valve Seal T3 ∅ 19,444 – ∅ 19,544
D1 21,7 x 1,814 LH
E1 ∅ 13,35 - ∅ 13,65 T4 1,814
D2 ∅ 13 – 13,1 E2 ∅ 8,0 - ∅ 8,4 T5 60°
D3 7,8 – 8,0 E3 7,5 – 7,8 T6 R 0,249
D4 8,6 – 8,7 NBR or equivalent T7 ∅ 21,6 – ∅ 21,7
EN 549
A2/H3 T8 ∅ 20,422 – ∅ 20,522
T9 ∅ 18,7 – ∅ 18,8 Figure 2 — Type G.2 - Threaded connection 21,7 x 1,814 LH - 60°– Hand tightened
SIST EN 15202:2007



EN 15202:2006 (E) 8 Dimensions in millimetres
Key Connector Seal 1 connector A1 ∅ 27 - ∅ 27,21 B1 ∅ 25,7 - ∅ 26,3 2 seal A2 ∅ 13,9 - ∅ 14,1 B2 ∅ 14,0 - ∅ 14,6 3 gasket A3 ∅ 3,0 - ∅ 3,2 B3 1,35 – 1,65 4 valve A4 ∅ 6,4 - ∅ 6,6 NBR or equivalent
A5 ∅ 13,7 - ∅ 13,9 EN 549
A2/H3 A6 M16 x 1,5-6g Valve 5 example of one configuration of the
inlet/gas passage to the connector A7 1,6 – 1,8 D1 M16 x 1,5 – 6H
A8 1,4 – 1,6 D2 ∅ 8,4 – ∅ 8,6
A9 3,9 – 4,1 D3 ∅ 26,5 – ∅ 27,3
A10 1,2 – 1,4 D4 1 x 45°
A11 13,4 – 13,6 D5 10,3 – 10,5
Gasket D6 10,2 – 10,6
C1 ∅ 7,5 ± 0,15 D7 1,0 min.
C2 ∅ 17,0 ± 0,1
C3 1,5 ± 0,15
C4 4,0 ± 0,15
Figure 3 — Type G.3 - Threaded connection M16 x 1,5 R - Hand tightened SIST EN 15202:2007



EN 15202:2006 (E) 9 Dimensions in millimetres
Key Connector/Nut Seal 1 nut A1 ∅ 18,8 - ∅ 19,2 B1 ∅ 19,8 - ∅ 19,2 2 connector A2 √Ra 3,2 B2 ∅ 11,6 - ∅ 12 3 seal A3 ∅ 11,3 - ∅ 11,7 B3 1,9 – 2,1 4 valve A4 ∅ 10,8 - ∅ 11,2 NBR or equivalent - EN 549
A2/H3
A5 ∅ 11,89 - ∅ 12,0 or aluminium* or polyamide** * For guidance on the
A6 1,7 – 1,9 Valve selection of aluminium, see
A7 4,9 – 5,1 C1 W 21,8 x 1,814 LH DIN 477-1 EN ISO 11114-1 A8 5,9 – 6,1 C2 ∅ 12,7 – ∅ 13,3 ** For guidance on theA9 ∅8 max.C36,8 – 7,2 selection of polyamide, see
A10 30 A/F C4 9,0 min. EN ISO 11114-2 A11 ∅ 16,15 - ∅ 16,26 C5 √Ra 3,2
A12 21,0 – 21,3 C6 11,5 min.
A13 16,0 – 16,3
A14 W 21,8 x 1/1,814 LH DIN 477-1
A15 ∅ 30,0 – ∅ 30,1
Figure 4 — Type G.4 - Threaded connection W 21,8 x 1,814 LH - 55°– Spanner tightened SIST EN 15202:2007



EN 15202:2006 (E) 10 Dimensions in millimetres
Key Connector/Nut Seal 1 nut A1 ∅ 29,8 - ∅ 30 B1 ∅ 18,8 - ∅ 19,2 2 connector A2 ∅ 16,15 - ∅ 16,26 B2 ∅ 6,9 - ∅ 6,95 3 seal A3 10,3 – 10,7 B3 1,9 – 2,1 4 valve A4 R 0,75 The seal material is polyamide*.
A5 16,0 - 16,3 The Connector/Nut and seal also fits G12 valve A6 21,0 – 21,3 Valve A7 W 21,8 x 1,814 LH DIN 477-1 C1 W 21,8 x 1,814 LH DIN 477-1 * For guidance on the selection of polyamide, see EN ISO 11114-2 A8 30 A/F C2 ∅ 12,7 – ∅ 13,3
A9 ∅ 15,84 - ∅ 15,96 C3 6,8 – 7,2
A10 17 min. C4 9,0 min.
A11 3,9 – 4,1 C5 √Ra 3,2
A12 6,8 – 7,2 C6 11,5 min.
A13 ∅ 18,8 – ∅ 19,2 C7 0,5 x 90°
A14 ∅ 6,92 - ∅ 6,96
A15 ∅ 3,9 - ∅ 4,1
A16 √Ra 3,2
Figure 5 — Type G.5 - Threaded connection W 21,8 x 1,814 LH – 55°– Spanner tightened SIST EN 15202:2007



EN 15202:2006 (E) 11 Dimensions in millimetres
Key Connector Seal Valve 1 nut A1 ∅ 15,8 - ∅ 16 B1 59° - 61° C1 W 22 x 1,155 LH 2 connector A2 ∅ 11 - ∅ 11,2 B2 ∅ 15 – ∅ 15,3 C2 ∅ 15,5 - ∅ 15,7 3 seal A3 ∅ 18,8 - ∅ 19 B3 ∅ 10,8 – ∅ 11,2 C3 ∅ 11,9 - ∅ 12,1 4 valve
A4 2,9 – 3,1 B4 ∅ 5,8 – ∅ 6,0 C4 59° - 61°
A5 2,8 – 3,2
B5 ∅ 8 + 3 deformation ribs C5 ∅ 8,0 - ∅ 8,05 A6 6,3
– 6,7 B6 10,0 – 10,5 C6 11 min. A7 W 22 x 1,155 LH B7 1,0 – 1,2 C7 1,2 – 1,4 A8 ∅ 28,3 – ∅ 28,7 The seal material is polyamide*. C8 9 min. * For guidance on the selection of polyamide, see EN ISO 11114-2 A9 11,8 – 12,2
Figure 6 — Type G.6 - Threaded connection W 22 x 1,155 LH – Hand tightened
SIST EN 15202:2007



EN 15202:2006 (E) 12 Dimensions in millimetres
Key Connector/Nut Valve 1 nut A1 Nom ∅ 13 - ∅ 16 (+0,1+0,37) C1 G 5/8 L.H EN ISO 228-1 2 connector A2 G 5/8 A LH EN ISO 228-1 C2 ∅ 14 datum 3 valve A3 17 – 18 C3 ∅ 11,5 max WARNING
A4 ∅ 20,25 - ∅ 20,55 C4 59° - 61°
√Ra 0,8 A5 ∅ 14,0 datum C5 20,35 – 20,65 G.9 type should not be fitted into the G.7 type as this may produce an unsafe connection. A6 R18,75 – 19,25
√Ra 0,8 C6 17,75 – 18,25
A7 9,8 – 10,8 C7 14,3 min.
A8 7,85 – 8,15 C8 ∅ 37,75
A9 9,5 C9 R 0,5 - 1,0
A10 Nom. ∅ 13 - ∅ 16
(-0,1-0,37)
A11 24 A/F . 28 A/F . 30,5 A/F
A12 25 min.
A13 12,5 min.
A14 ∅ 9 max.
Figure 7 — Type G.7 - Threaded connection G 5/8 LH – Spanner tightened
SIST EN 15202:2007



EN 15202:2006 (E) 13 Dimensions in millimetres
Key Connector/Nut Seal 1 nut A1 ∅ 18,85 - ∅ 19,15 B1 ∅ 10,0 - ∅ 10,25 2 connector A2 ∅ 11,75 - ∅ 12,15 B2 ∅ 17,25 - ∅ 17,75 3 seal A3 ∅ 10,00 - ∅ 10,15 B3 1,5 – 1,75 4 valve
A4 Nom. ∅ 13 - ∅ 16 (-0,1-0,37) NBR or equivalent
A5 1,4 – 1,70 EN 549
A2/H3
A6 3,25 – 3,75 Valve
A7 4,25 – 4,75 C1 ∅ 12,55 - ∅ 12,85
A8 M 21,8 x 1,814 6H L.H. ISO 68-1 C2 M 21,8 x 1,814 6g LH ISO 68-1
A9 Nom. ∅ 13 - ∅ 16 (+0,37+0,1) C3 7,5 – 8,5
A10 9 min. C4 6 min.
A11 17 min. C5 10,5 min.
A12 28 A/F.
30,5 A/F C6 16,0 ± 0,15
A13 12,75 – 13,25 C7 0,7
A14 ∅ 8 max. C8 60°
C9 R 0,2 max. Figure 8 — Type G.8 - Threaded connection 21,8 x 1,814 – L.H.- Spanner tightened SIST EN 15202:2007



EN 15202:2006 (E) 14
Dimensions in millimetres
Key Connector/Nut Valve Thread 1 nut
A1 Nom ∅ 13 - ∅ 16
(+0,2+0,05) C1 0,885 inch – 14NGO* – LH INT T1 ∅ 22,479
min. 2 connector A2 0,880 inch – 14NGO* – LH EXT C2 ∅ 11,1 max T2 ∅ 21,30 – ∅ 21,39 3 valve A3 17,07
– 17,83 C3 59°
-
61°
√Ra 0,8 T3 ∅ 20,51 – ∅ 20,71 4 nut thread A4 ∅ 19,0 - ∅ 19,1 C4 25,4 min. T4 1,814 5 valve thread A5 R19,05
√Ra 0,8 C5 17,07 – 17.83 T5 60°
A6 ∅ 18,6 - ∅ 18,9 C6 14,3 min. T6 R 0,249 A7 10,2 – 10,4 C7 3,18 min. T7 ∅ 22,22 – ∅ 22,35 A8 Nom ∅ 13 - ∅ 16
(-0,05-0,2) C8 31,75 min. T8 ∅ 21,08 – ∅ 21,17 A9 11,53 – 12,29 C9 17,07 – 17,83 T9 ∅ 20,125 max. * NGO – National Gas Outlet in accordance with ANSI/CGA V-1 A10 22,2 A/F 24 A/F 28,6 A/F 30 A/F.
A11 25 min.
A12 13,5 min.
A13 ∅ 4 - ∅ 7.
A14 19,8 min
Figure 9 — Type G.9 - Threaded connection/Nut 0,885 NGO* LH – Spanner tightened SIST EN 15202:2007



EN 15202:2006 (E) 15 Dimensions in millimetres
Key Connector/Nut Seal Thread 1 nut A1 Nom ∅ 13 - ∅ 16 (+0,2+0,05) B1 ∅ 17,3 - ∅ 17,7 T1 ∅ 22,479
min. 2 connector A2 0,880 inch – 14NGO* – LH EXT B2 ∅ 9,3 - ∅ 9,7 T2 ∅ 21,30 – ∅ 21,39 3 seal A3 17,07 – 17,83 B3 6,9 – 7,1 T3 ∅ 20,51 – ∅ 20,71 4 valve A4 Nom ∅ 13 - ∅ 16 (-0,05-0,2) B4 ∅ 7,9 - ∅8,1 T4 1,814 5 nut thread A5 ∅ 3,5 - ∅ 5,5 B5 0,8 – 1,2 T5 60° 6 valve thread A6 ∅ 9,4 – ∅ 9,6 B6 ∅ 13,8 - ∅ 14,2 T6 R 0,249 A7 9,9 – 10,1 NBR or equivalent
T7 ∅ 22,22 – ∅ 22,35 A8 5,9 – 6,1 EN 549
A2/H3
T8 ∅ 21,08 – ∅ 21,17 A9 13,5 min. Valve – (same as G9) T9 ∅ 20,125 max. A10 22.2 A/F 24 A/F 28.6 A/F 30 A/F.a C1 0,885 inch– 14NGO* – LH INT
A11 25 min. C2 ∅ 11,1 max
a Dimension A10 only applies to spanner tightened connections. Hand tightened versions may also be used with different dimensions. A12 ∅ 19 – ∅ 19,1 C3 59° - 61°
√Ra 0,8
A13 ∅ 17,4 - ∅ 17,6 C4 25,4 min.
A14 ∅ 8,4 – ∅ 8,6 C5 17,07 – 17.83
A15 0,9 – 1,1 C6 14,3 min.
* NGO – National Gas Outlet in accordance with ANSI/CGA V-1 A16 19,8 min C7 3,18 min
C8 31,75 min
C9 17,07 – 17,83
Figure 10 — Type G.10 - Threaded connection 0,885 NGO* LH – Rubber nose SIST EN 15202:2007



EN 15202:2006 (E) 16 Dimensions in millimetres
Key Connector/Nut Seal 1 nut A1 W 21,8 x 1,814 LH - DIN 477-1 B1 ∅ 17,0 - ∅ 17,3 2 connector A2 ∅ 16,15 - ∅ 16,26 B2 ∅ 10,0 - ∅ 10,2 3 seal A3 17,8 – 18,2 B3 3,5 – 3,7 4 valve
A4 13,8 – 14,2 B4 ∅ 16,0 – 16,3
A5 ∅ 18,8 - ∅ 19,2 NBR or equivalent
A6 ∅ 15,84 - ∅15,95 EN 549
A2/H3
A7 ∅ 14,8 - ∅15,2 Valve
A8 ∅ 10,8 - ∅ 11,2 C1 W 21,8 x 1,814 LH - DIN 477-1
A9 ∅ 6,92 - ∅ 6,96 C2 ∅ 16,9 – ∅ 17,1
A10 ∅ 4 max. C3 ∅ 15,9 - ∅ 16,1
A11 1,9 – 2,1 C4 ∅ 9,9 - ∅ 10,1
A12 10,8 – 11,2 C5 ∅ 7,04 – ∅ 7,1
A13 3,9 – 4,1 C6 ∅ 0,9 - ∅ 1,1
A14 5 wings equally spaced or similar C7 12 min.
A15 R0,9 – 1,1 C8 3,5 – 3,7
A16 ∅24,8 – ∅25,9 C9 9 min.
A17 9 min.
Figure 11 — Type G.12 - Threaded connection W 21,8 x 1,814 LH – Hand tightened SIST EN 15202:2007



EN 15202:2006 (E) 17 Dimensions in millimetres
Key Nut Connector 1 nut A1 W 21,8 x 1,814 LH - DIN 477-1 B1 ∅ 18,8 - ∅ 19,2 2 connector A2 ∅ 16,15 - ∅ 16,26 B2 ∅ 15,84 - ∅ 15,95 3 seal A3 17,8 – 18,2 B3 ∅ 6,92 - ∅ 6,96 4 valve A4 13,8 – 14,2 B4 ∅5,4 - ∅ 5,6
A5 5 wings equally spaced or similar. B5 ∅ 2,9 - ∅ 3,1
Also used with spanner flats 30 A/F B6 2,9 – 3,1
A6 9 min. B7 7 max.
B8 3,9 – 4,1
Seal B9 14 min.
C1 ∅ 17 - ∅ 18 Valve
C2 ∅ 5,4 – ∅ 5,6 D1 W 21,8 x 1,814 LH -
DIN 477-1
C3 2,9 – 3,1 D2 ∅ 12,7 - ∅ 13,3
NBR or equivalent D3 6,8 – 7,2
EN 549
A2/H3 D4 9 min. Figure 12 — Type G.19 - Threaded connection W 21,8 x 1,814 LH – Hand tightened
SIST EN 15202:2007



EN 15202:2006 (E) 18 Dimensions in millimetres
Key Connector Seal Valve 1 connector A1 ∅ 25,6 - ∅ 25,8 B1 ∅ 25,2
- ∅ 25,8 C1 ∅ 24,7 - ∅ 25,3 2 seal A2 W 14,8 x 1/18
B2 ∅ 13,2 ∅ 13,8 C2 ∅ 14,7 – ∅ 15,3 3 valve A3 ∅ 4,8 - ∅ 5,0 B3 1,8 – 2,2 C3 W 14,8 x 1/18 4 retaining ring A4 ∅ 1,9 - ∅ 2,1 NBR or equivalent C4 6,8 – 7,2 5 lower seal A5 1,9 – 2,1 EN 549
A2/H3 C5 1,5 x 45°
A6 15,1 – 15,3 Lower seal C6 11,3 – 11,7
A7 6,5 – 6,7 D1 7,0 ± 0,1 C7 15,3 – 15,7
NBR or equivalent
EN 549
A2/H3
Figure 13 — Type G.21 - Threaded connection W 14,8 x 1/18 – Hand tightened
...