High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

IEC 61162-1:2016 is available as href="https://webstore.iec.ch/publication/25747">IEC 61162-1:2016
RLV which contains the International Standard and its Redline
version, showing  all changes of the technical content compared to
the previous edition.
IEC 61162-1:2016(E) contains the requirements for data communication between maritime electronic instruments, navigation and radiocommunication equipment when interconnected via an appropriate system. This part of IEC 61162 is intended to support one-way serial data transmission from a single talker to one or more listeners. These data are in printable ASCII form and may include information such as position, speed, depth, frequency allocation, etc. Typical messages may be from about 11 to a maximum of 79 characters in length and generally require transmission no more rapidly than one message per second. The electrical definitions in this standard are not intended to accommodate high-bandwidth applications such as radar or video imagery, or intensive database or file transfer applications. Since there is no provision for guaranteed delivery of messages and only limited error checking capability, this standard should be used with caution in all safety applications. For applications where a faster transmission rate is necessary, reference should be made to IEC 61162-2. For applications to shore based equipment of the automatic identification system (AIS) reference should be made to the IEC 62320 series. This fifth edition cancels and replaces the fourth edition published in 2010, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new identifiers have been added to Table 4;
- the sentences CBR and MEB have been removed as they are now solely used by AIS shore based equipment;
- new sentences ACN, ALC, ALF, ARC, EPV, HCR, HRM, MOB, NSR, RLM, RRT, SM1, SM2, SM3, SM4, SMB, SPW and TRL have been added;
- revisions have been made to ABK, ABM, GNS, NAK, NRM, RMC, ROR and TTD;
- the methods of testing in Annex B have been revised.

Hochspannungs-Schaltgeräte und -Schaltanlagen - Teil 200: Metallgekapselte Wechselstrom-Schaltanlagen für Bemessungsspannungen über 1 kV bis einschließlich 52 kV

Appareillage à haute tension - Partie 200: Appareillage sous enveloppe métallique pour courant alternatif de tensions assignées supérieures à 1 kV et inférieures ou égales à 52 kV

Visokonapetostne stikalne in krmilne naprave - 200. del: Stikalne in krmilne naprave v kovinskih ohišjih za naznačene izmenične napetosti nad 1 kV in do vključno 52 kV - Popravek AC

General Information

Status
Withdrawn
Publication Date
13-Aug-2015
Withdrawal Date
04-Jul-2024
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
05-Jul-2024
Due Date
28-Jul-2024
Completion Date
05-Jul-2024

Relations

Effective Date
03-Aug-2021
Effective Date
01-Sep-2015
Corrigendum

SIST EN 62271-200:2012/AC:2015

English and French language
1 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 62271-200:2012/AC:2015 is a corrigendum published by the Slovenian Institute for Standardization (SIST). Its full title is "High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV". This standard covers: IEC 61162-1:2016 is available as <a href="https://webstore.iec.ch/publication/25747">IEC 61162-1:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61162-1:2016(E) contains the requirements for data communication between maritime electronic instruments, navigation and radiocommunication equipment when interconnected via an appropriate system. This part of IEC 61162 is intended to support one-way serial data transmission from a single talker to one or more listeners. These data are in printable ASCII form and may include information such as position, speed, depth, frequency allocation, etc. Typical messages may be from about 11 to a maximum of 79 characters in length and generally require transmission no more rapidly than one message per second. The electrical definitions in this standard are not intended to accommodate high-bandwidth applications such as radar or video imagery, or intensive database or file transfer applications. Since there is no provision for guaranteed delivery of messages and only limited error checking capability, this standard should be used with caution in all safety applications. For applications where a faster transmission rate is necessary, reference should be made to IEC 61162-2. For applications to shore based equipment of the automatic identification system (AIS) reference should be made to the IEC 62320 series. This fifth edition cancels and replaces the fourth edition published in 2010, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - new identifiers have been added to Table 4; - the sentences CBR and MEB have been removed as they are now solely used by AIS shore based equipment; - new sentences ACN, ALC, ALF, ARC, EPV, HCR, HRM, MOB, NSR, RLM, RRT, SM1, SM2, SM3, SM4, SMB, SPW and TRL have been added; - revisions have been made to ABK, ABM, GNS, NAK, NRM, RMC, ROR and TTD; - the methods of testing in Annex B have been revised.

IEC 61162-1:2016 is available as <a href="https://webstore.iec.ch/publication/25747">IEC 61162-1:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61162-1:2016(E) contains the requirements for data communication between maritime electronic instruments, navigation and radiocommunication equipment when interconnected via an appropriate system. This part of IEC 61162 is intended to support one-way serial data transmission from a single talker to one or more listeners. These data are in printable ASCII form and may include information such as position, speed, depth, frequency allocation, etc. Typical messages may be from about 11 to a maximum of 79 characters in length and generally require transmission no more rapidly than one message per second. The electrical definitions in this standard are not intended to accommodate high-bandwidth applications such as radar or video imagery, or intensive database or file transfer applications. Since there is no provision for guaranteed delivery of messages and only limited error checking capability, this standard should be used with caution in all safety applications. For applications where a faster transmission rate is necessary, reference should be made to IEC 61162-2. For applications to shore based equipment of the automatic identification system (AIS) reference should be made to the IEC 62320 series. This fifth edition cancels and replaces the fourth edition published in 2010, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - new identifiers have been added to Table 4; - the sentences CBR and MEB have been removed as they are now solely used by AIS shore based equipment; - new sentences ACN, ALC, ALF, ARC, EPV, HCR, HRM, MOB, NSR, RLM, RRT, SM1, SM2, SM3, SM4, SMB, SPW and TRL have been added; - revisions have been made to ABK, ABM, GNS, NAK, NRM, RMC, ROR and TTD; - the methods of testing in Annex B have been revised.

SIST EN 62271-200:2012/AC:2015 is classified under the following ICS (International Classification for Standards) categories: 29.130.10 - High voltage switchgear and controlgear. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 62271-200:2012/AC:2015 has the following relationships with other standards: It is inter standard links to SIST EN IEC 62271-200:2021, SIST EN 62271-200:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase SIST EN 62271-200:2012/AC:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Hochspannungs-Schaltgeräte und -Schaltanlagen - Teil 200: Metallgekapselte Wechselstrom-Schaltanlagen für Bemessungsspannungen über 1 kV bis einschließlich 52 kVAppareillage à haute tension - Partie 200: Appareillage sous enveloppe métallique pour courant alternatif de tensions assignées supérieures à 1 kV et inférieures ou égales à 52 kVHigh-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV29.130.10Visokonapetostne stikalne in krmilne napraveHigh voltage switchgear and controlgearICS:Ta slovenski standard je istoveten z:EN 62271-200:2012/AC:2015SIST EN 62271-200:2012/AC:2015en,fr01-september-2015SIST EN 62271-200:2012/AC:2015SLOVENSKI
STANDARD
IEC 62271-200:2011/COR1:2015 – 1 –
 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ÉLECTROTECHNIQUE I
...