SIST EN 300 019-2-3 V3.1.1:2026
(Main)Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 2-3: Specification of environmental tests - Sub-part 3: Stationary use at weatherprotected locations
- Abstract
The present document specifies test severities and methods for the verification of the required resistibility of equipment according to the relevant environmental class.
The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the environmental conditions stated in ETSI EN 300 019-1-3 [1].
- Status
- Published
- Public Enquiry End Date
- 29-Sep-2026
- Publication Date
- 20-Oct-2026
- Technical Committee
- SPN - Services and Protocols for Networks
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 19-Oct-2026
- Due Date
- 24-Dec-2026
- Completion Date
- 21-Oct-2026
Buy Documents
ETSI EN 300 019-2-3 V3.1.0 (2026-07) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 3: Stationary use at weatherprotected locations
ETSI EN 300 019-2-3 V3.1.1 (2026-10) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 3: Stationary use at weatherprotected locations
SIST EN 300 019-2-3 V3.1.1:2026 is the Slovenian adoption of ETSI EN 300 019-2-3 V3.1.1, published by SIST. It specifies environmental test severities and test methods for telecommunications equipment used at stationary weatherprotected locations, so engineers can verify that equipment matches the relevant environmental class before deployment.
What does SIST EN 300 019-2-3 V3.1.1:2026 specify?
SIST EN 300 019-2-3 V3.1.1:2026 specifies how to test telecommunications equipment against the environmental conditions associated with stationary use at weatherprotected locations. In practice, it tells you which environmental stresses to apply, which test methods to use, and what performance level is expected during and after testing.
The document is organized around general test rules, environmental test specifications, and an earthquake test section. It contains main clauses 1 to 5, plus two informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Impact of corrosion due to dust, including a possible test method and a schematic chamber concept |
| Annex B | Bibliography |
What are the key requirements of SIST EN 300 019-2-3 V3.1.1:2026?
The standard is built around a few practical rules that matter when planning qualification tests for telecom equipment. The most important point is that the equipment is generally tested in its operational state, under the conditions described for the relevant class.
Test setup and operating condition
Clause 4.0 requires the equipment to be tested in its operational state throughout the environmental exposure unless stated otherwise. Clause 4.1 adds that input and load conditions should drive the equipment to full utilization, and heat dissipation should be maximized, except in the steady-state low-temperature test where it should be minimized.
That matters because the test must represent real use, not a lightly loaded bench setup. It helps uncover failures caused by power, heat, or control behavior that only appear when the equipment is working hard.
Performance criteria A, B, C and D
Clause 4.2 defines four performance criteria. Criteria A, B and C focus on functional behavior before, during, and after the test, with different levels of tolerance for temporary loss of function. Criterion D applies to the enclosure and requires no corrosion traces or enclosure deterioration at the end of the test.
In practice, the criterion used decides what the laboratory must monitor and what counts as a pass. Criterion C, for example, allows temporary loss of function during exposure, but the equipment must recover without replacement of components, manual rebooting, or human intervention.
Classes T 3.10 and T 3.10E
Clause 4.3 covers temperature-controlled enclosed locations having no humidity control. For T 3.10, the standard brings together cold, dry heat, temperature change, damp heat, low air pressure for suitable products, solar and heat radiation effects, and random vibration.
T 3.10E is the exceptional-operating version of the same class, with extended temperature and humidity ranges. The practical effect is that design and verification must cover both normal operation and more severe but still credible environmental exposure.
The notes in this clause also matter. For example, low humidity has no IEC 60068-2 series test method here, and chemically active substances are handled through design guidance rather than a dedicated test. That means the engineer must consider materials, sealing, and corrosion risk during design, not just at test time.
Classes T 3.11 and T 3.12
Clause 4.4 covers enclosed locations having no temperature or humidity control. Compared with T 3.10, this class adds more demanding humidity behavior, condensation, dripping water, icing and frosting, and the same random vibration approach. It is the more exposed indoor or sheltered-location case.
Clause 4.5 covers locations having neither temperature nor humidity control. This class is the most exposed of the three, and it includes wind-driven rain, icing and frosting, and the same mechanical test approach. The notes also point the reader to design considerations for dust, biologic contamination, and dripping water exposure.
For both T 3.11 and T 3.12, some environmental factors are not assigned a separate test, but they still matter in material choice and design. That is important because the standard is not only about lab exposure - it also tells you what to design against.
Earthquake test specification
Clause 5 applies when the customer specifies earthquake conditions, and it applies to classes 3.10 to 3.12. The clause starts with a vibration response investigation to find the lowest resonant frequency of the mounted specimen, using either sine sweep or random testing.
The actual earthquake test uses a time-history method with a Required Response Spectrum (RRS) and Zero Period Acceleration (ZPA). The specimen is mounted in its in-use position, the mounting should represent the worst case for weight and stiffness, and the influence of connections, piping, and cables must be taken into account.
That matters because earthquake behavior depends heavily on how the equipment is installed, not just on the product itself. The clause also allows axis reduction in one specific case and states that the extent of functional operation during the test must be defined in the product specification.
What terms does SIST EN 300 019-2-3 V3.1.1:2026 define?
- Acceleration Spectral Density (ASD) - a vibration measure used in the random vibration tests, expressing spectral content across frequency.
- Hydrogen Fluoride (HF) - one of the chemically active substances listed when describing environmental severity.
- Printed Circuit Board (PCB) - the circuit board type explicitly mentioned in Annex A when discussing corrosion impact.
- Root Mean Square (RMS) - a statistical measure used in the vibration notes for information on overall severity.
- Required Response Spectrum (RRS) - the spectrum used for the earthquake time-history test to define the response target.
- Zero Period Acceleration (ZPA) - the acceleration level used with the earthquake test spectrum definition.
Who uses SIST EN 300 019-2-3 V3.1.1:2026?
SIST EN 300 019-2-3 V3.1.1:2026 is used by engineers, test laboratories, quality managers, and buyers working with telecommunications equipment. It is relevant when defining environmental qualification, setting test plans, selecting the right environmental class, or checking whether a product can be used in a specific weatherprotected location.
It is also useful for designers and materials engineers because several clauses point to design considerations rather than direct tests, especially for corrosion, dust, humidity, and biologically active exposure. Procurement and compliance teams use it to state acceptance criteria and to compare test evidence from suppliers.
What changed in SIST EN 300 019-2-3 V3.1.1:2026 from the previous edition?
The document history lists V3.1.1 as the October 2026 publication, following V3.1.0 from July 2026.
Which standards are used with SIST EN 300 019-2-3 V3.1.1:2026?
- ETSI EN 300 019-1-3 [1] - defines the environmental conditions and class structure that this part tests against.
- IEC 60068-2-1 [2] - provides the cold test method used in the climatic tables.
- IEC 60721-3-3 [4] - supplies the classification of environmental groups for stationary use at weatherprotected locations.
- IEC 60068-2-6 [5] - provides the sinusoidal vibration method referenced for earthquake response investigation.
- IEC 60068-2-2 [6] - provides the dry heat method.
- IEC 60068-2-14 [7] - provides the change-of-temperature method.
- IEC 60068-2-78 [8] - provides the damp heat, steady-state method.
- IEC 60068-2-30 [9] - provides the damp heat, cyclic method used where condensation is required.
- IEC 60068-2-64 [10] - provides the random vibration method.
- IEC 60068-2-57 [12] - provides the time-history earthquake method.
- IEC 60068-2-68 [13] - provides the dust and sand method referenced for mechanically active substances.
- IEC 60068-2-13 [14] - provides the low air pressure test used for selected products.
- IEC 60068-2-18 [15] - provides the water test method used when dripping water exposure is relevant.
- ISO 9223 [16] - gives the corrosivity classification used for chemically active substances.
- ISO 9226 [i.3] - gives a way to determine corrosion rate on standard specimens.
What does the SIST EN 300 019-2-3 V3.1.1:2026 document contain?
The body of the document is mainly a set of tables that map environmental parameters to severities, durations, references, methods, performance criteria, and explanatory notes. Those tables are what a test lab uses to turn an environmental class into an actual test program.
Clause 4 contains the climatic and mechanical specifications for T 3.10, T 3.10E, T 3.11 and T 3.12. Clause 5 adds the earthquake test with a preliminary response investigation, a required response spectrum, and a time-history test procedure.
Annex A gives an informative method for evaluating corrosion due to dust, including a dust test followed by a humidity-based corrosion exposure and a schematic chamber arrangement. Annex B is a bibliography for further background reading.
Buy Documents
ETSI EN 300 019-2-3 V3.1.0 (2026-07) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 3: Stationary use at weatherprotected locations
ETSI EN 300 019-2-3 V3.1.1 (2026-10) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 3: Stationary use at weatherprotected locations
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-2-3 V3.1.1:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 2-3: Specification of environmental tests - Sub-part 3: Stationary use at weatherprotected locations". This standard covers: The present document specifies test severities and methods for the verification of the required resistibility of equipment according to the relevant environmental class. The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the environmental conditions stated in ETSI EN 300 019-1-3 [1].
The present document specifies test severities and methods for the verification of the required resistibility of equipment according to the relevant environmental class. The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the environmental conditions stated in ETSI EN 300 019-1-3 [1].
SIST EN 300 019-2-3 V3.1.1:2026 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-2-3 V3.1.1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2: Specification of environmental tests;
Sub-part 3: Stationary use at weatherprotected locations
2 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Reference
REN/EE-017016
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part of this document may be reproduced in any form, by any means and in any media, without the prior written
authorization of ETSI and except as expressly permitted below.
By way of exception and when the document is a normative deliverable (European Standard (EN),
Technical Specification (TS), Group Specification (GS) or ETSI Standard (ES)), ETSI authorizes to reproduce
and incorporate into products, services and technical documentation only those extracts (e.g. templates) that are strictly
necessary for the technical implementation of the normative deliverable, to ensure compliance with the latter.
Nothing in this notice shall be construed as limiting any mandatory exceptions to copyright provided by applicable law.
© ETSI 2026.
All rights reserved.
ETSI
3 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 7
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental test specifications . 7
4.0 General . 7
4.1 Equipment setup and configuration . 8
4.2 Performance criteria . 8
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no humidity
control . 9
4.4 Specification T 3.11: Enclosed locations having no temperature or humidity control . 15
4.5 Specification T 3.12: Locations having neither temperature nor humidity control . 18
5 Earthquake test specification . 23
5.0 General . 23
5.1 Vibration response investigation . 23
5.2 Test conditioning . 24
Annex A (informative): Impact of corrosion due to dust . 26
A.0 General . 26
A.1 Test condition . 26
A.1.0 Introduction . 26
A.1.1 Dust test condition . 26
A.1.2 Corrosion test . 26
A.1.3 Pass criteria . 26
A.2 Schematic Diagram of Suspension Dust Test Chamber . 27
Annex B (informative): Bibliography . 29
History . 30
ETSI
4 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables (European Standard (EN), Technical Specification (TS),
Group Specification (GS) or ETSI Standard (ES)) may have been declared to ETSI. The declarations pertaining to these
essential IPRs, if any, are publicly available for ETSI members and non-members, and can be found in
ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI EN Approval Procedure (ENAP).
The present document is part 2, sub part 3 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Part 2: "Specification of environmental tests": (see note 2)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
ETSI
5 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
6 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the
environmental conditions stated in ETSI EN 300 019-1-3 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3 (V3.1.1) (2026): "Environmental Engineering (EE); Environmental
conditions and environmental tests for telecommunications equipment; Part 1: Classification of
environmental conditions; Sub-part 3: Stationary use at weatherprotected locations".
[2] IEC 60068-2-1:2025: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[3] Void.
[4] IEC 60721-3-3:2019: "Classification of environmental conditions - Part 3-3: Classification of
groups of environmental parameters and their severities - Stationary use at weatherprotected
locations".
[5] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[6] IEC 60068-2-2:2025: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[7] IEC 60068-2-14:2023: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-78:2025: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[9] IEC 60068-2-30:2025: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[10] IEC 60068-2-64:2008+AMD1:2019: "Environmental testing - Part 2-64: Tests - Test Fh:
Vibration, broadband random and guidance".
[11] Void.
[12] IEC 60068-2-57:2013: "Environmental testing - Part 2-57: Tests - Test Ff: Vibration -
Time-history and sine-beat method".
[13] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[14] IEC 60068-2-13:2021: "Environmental testing - Part 2-13: Tests - Test M: Low air pressure".
[15] IEC 60068-2-18:2017: "Environmental testing - part 2-18: Tests - Test R and guidance: Water".
ETSI
7 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
[16] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
[i.2] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2: Specification of environmental
tests; Sub-part 0: Introduction".
[i.3] ISO 9226:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Determination
of corrosion rate of standard specimens for the evaluation of corrosivity".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the terms given in ETSI EN 300 019-1-0 [i.1] apply.
3.2 Symbols
Void.
3.3 Abbreviations
Void.
4 Environmental test specifications
4.0 General
The equipment shall be tested in its operational state throughout the test conditions described in the present document.
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-3 [1].
ETSI EN 300 019-2-0 [i.2] forms a general overview of part 2 of this multi-part deliverable.
ETSI
8 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
4.1 Equipment setup and configuration
The equipment shall be tested in its operational state throughout the test conditions described in the present document
unless otherwise stated. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
4.2 Performance criteria
The following performance criteria shall apply in tests defined by the present document.
Performance criterion A:
The equipment shall function according to the manufacturer specifications before, during and after the tests. No
degradation of performance or loss of function is allowed below the performance level specified by the manufacturer
when the equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then
this may be deduced from the product description and documentation and what the user may reasonably expect from the
equipment if used as intended.
Performance criterion B:
The equipment shall function according to the manufacturer specifications before and after the tests. During the test it is
not required to monitor the equipment functionality. No degradation of performance or loss of function is allowed
below the performance level specified by the manufacturer when the equipment is used as intended. If the minimum
performance level is not specified by the manufacturer, then this may be deduced from the product description and
documentation and what the user may reasonably expect from the equipment if used as intended.
Performance criterion C:
The equipment shall function according to the manufacturer specifications before and after the tests. No degradation of
performance or loss of function is allowed below the performance level specified by the manufacturer when the
equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then this may be
deduced from the product description and documentation and what the user may reasonably expect from the equipment
if used as intended. During the application of the test, temporary loss of function is allowed but after the test the
equipment shall restore to the normal functionality without replacement of components, manual rebooting or human
intervention. The equipment shall sustain the test without permanent structural or mechanical damage.
Performance criterion D:
This performance criterion applies to the enclosure of the equipment. No corrosion traces (e.g. rust) or deterioration of
the enclosure shall occur at the end of the test.
ETSI
9 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no
humidity control
Specification T 3.10: Temperature-controlled enclosed locations having no humidity control - normal operating conditions.
The specification in table 1, table 2 and table 3 shall apply to temperature-controlled enclosed locations where humidity is usually not controlled.
Table 1: Test specification T 3.10: Temperature-controlled enclosed locations - climatic tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
Low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad/Ae: Cold A 1
High (°C) +40 +40 or +50 16 h IEC 60068-2-2 [6] Bb/Bd/Be: Dry heat A 2
Air
(°C) +5 to+40 2 cycles IEC 60068-2-14 [7] Nb: Change of A 3
temperature
Change
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 None 4
high (%) 85 85 4 d IEC 60068-2-78 [8] Cab: Damp heat A 5
Relative
(°C) +30 steady state
Humidity
condensation No None
1 None 4
low (g/m )
Absolute
25 None 7
high (g/m )
low (kPa) 70 70 2 h IEC 60068-2-13 [14] Test M: Low air A 8
pressure
Pressure
Air
high (kPa) 106 None 8
Speed (m/s) 1,0 None 4
Intensity No None
Rain
low temperature No None
Other No None
Water
sources
Icing & No None
frosting
Solar 700 None 9
(W/m )
Radiation
Heat 600 None 10
(W/m )
ETSI
10 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
[16] None 11
SO (mg/m )
Sulphur
[16] None 11
HS (mg/m )
salt mist [16] None 11
[16] None 11
Chlorine Cl (mg/m )
Chemically
[16] None 11
HCI (mg/m )
active
[16] None 11
NO (mg/m )
x
substances
Nitrogen
[16] None 11
NH (mg/m )
Hydrogen [16] None 11
(mg/m )
fluoride HF
Ozone O [16] None 11
(mg/m )
sedimentation 6 12
Mechanically
Dust (mg/(m d))
active
no None
suspension (mg/m )
substances
no None
Sand
(mg/m )
Micro organisms negligible
Flora and
fauna Rodents, insects negligible
ETSI
11 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
NOTE 1: (Air temperature, low).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If a cold start up test is performed, the characteristic severity should be used as a cold start up temperature, but it may be modified (within the class characteristic
severity range) by the product specification. In this case, the cold start up test shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If two test temperatures are given, the lower test temperature applies if the equipment is protected against solar and heat radiation or the equipment is ventilated
(natural or forced). The higher test temperature includes the heating effects of solar and/or heat radiation. If a high temperature start up test is performed, the
characteristic severity should be used as a high start up temperature, but it may be modified (within the class characteristic severity range) by the product
specification. In this case, the high temperature start up test shall commence once high temperature stability is achieved.
NOTE 3: (Air temperature, change).
The change of temperature test is normally used to check design tolerance. IEC 60068-2-14 [7] Test Nb shall be used. For change of temperature of 0,5 °C/min,
the cooling gradient may be reduced to 0,2 °C/min where test chamber restrictions preclude a gradient of 0,5 °C/min.
NOTE 4: (Relative humidity, low).
There is no IEC 60068-2 series test method for this parameter.
NOTE 5: (Humidity, relative, high).
IEC 60068-2-78 [8] Test Cab shall be used with test values not higher than climatogram limits for this class.
NOTE 6: Void.
NOTE 7: (Humidity, absolute, high).
This effect is considered to be partly included in the damp heat test IEC 60068-2-78 [8] Test Cab.
NOTE 8: (Air pressure, low and high).
No test is recommended for normal applications, because the effect of air pressure is evaluated at the component level. For sealed products or for products
containing liquids, test M is recommended.
NOTE 9: (Radiation, solar).
The higher test temperature as described in note 2 includes the heating effect of solar radiation. Photochemical tests can be made separately for components
and materials.
NOTE 10: (Radiation, heat).
The higher test temperature as described in note 2 includes the heating effect.
NOTE 11: (Chemically active substances).
The characteristic severities are given in ISO 9223 [16]. For the chemically active substances, no specific tests are defined but they should be considered in the
design phase. The following references provide guidance for the design:
- ISO 9223:2012 [16]: this can be used to calculate the corrosion losses of standard metals.
- ISO 9226:2012 [i.3]: this can be used to determine corrosion losses of standard specimens.
NOTE 12: (Mechanically active substances).
The characteristic severities are much lower than lowest test severity in IEC 60068-2-68 [13] Test L and therefore no test is recommended. This condition should
be considered when designing the equipment and when choosing components and materials.
ETSI
12 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Table 2: Test specification T 3.10: Temperature-controlled enclosed locations having no humidity control - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail Characteristic Test severity Duration Reference Method Performance Notes
parameter severity criteria
2 2
Vibration Random acceleration spectral 0,01 30 minutes in IEC 60068-2-64 [10] Test Fh: A See note
0,01 (m/s ) /Hz
2 2
each Vibration,
density ((m/s ) /Hz)
direction broadband
5 Hz to 100 Hz
Frequency (Hz) 5 to 200
random
Shocks Shocks No
acceleration (m/s )
NOTE: (Vibration, random).
The test severity values are not specified in IEC 60068-2 series. The maximum test frequency has been reduced to 100 Hz, because between 100 Hz and 200 Hz
the contribution is insignificant.
Also at low and high frequency ends the ASD is reduced by 12 dB/octave.
Classes: 3.11/3.12
Acceleration RMS
1,06 m/s
(for information only)
Equipment under test shall be mounted in the "in-use" position. The equipment function shall be monitored throughout the test.
ETSI
13 Draft ETSI EN 300 019-2-3 V3.1.0 (2026-07)
Specification T 3.10E: Temperature-controlled enclosed locations having no humidity control - exceptional operating conditions.
The specification in table 3 shall apply to temperature-controlled enclosed locations where humidity is usually not controlled. The reference class is the same as for T 3.10, but
with extended temperature and humidity ranges.
Table 3: Test specification T 3.10E: Temperature-controlled enclosed locations, exceptional operating conditions - climatic tests
Environmental parameter Environmental Environmental test specification T 3.10E: In-use,
Conditio
...
EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2: Specification of environmental tests;
Sub-part 3: Stationary use at weatherprotected locations
2 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Reference
REN/EE-017016
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part of this document may be reproduced in any form, by any means and in any media, without the prior written
authorization of ETSI and except as expressly permitted below.
By way of exception and when the document is a normative deliverable (European Standard (EN),
Technical Specification (TS), Group Specification (GS) or ETSI Standard (ES)), ETSI authorizes to reproduce
and incorporate into products, services and technical documentation only those extracts (e.g. templates) that are strictly
necessary for the technical implementation of the normative deliverable, to ensure compliance with the latter.
Nothing in this notice shall be construed as limiting any mandatory exceptions to copyright provided by applicable law.
© ETSI 2026.
All rights reserved.
ETSI
3 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 7
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental test specifications . 8
4.0 General . 8
4.1 Equipment setup and configuration . 8
4.2 Performance criteria . 8
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no humidity
control . 9
4.4 Specification T 3.11: Enclosed locations having no temperature or humidity control . 15
4.5 Specification T 3.12: Locations having neither temperature nor humidity control . 18
5 Earthquake test specification . 23
5.0 General . 23
5.1 Vibration response investigation . 23
5.2 Test conditioning . 24
Annex A (informative): Impact of corrosion due to dust . 26
A.0 General . 26
A.1 Test condition . 26
A.1.0 Introduction . 26
A.1.1 Dust test condition . 26
A.1.2 Corrosion test . 26
A.1.3 Pass criteria . 26
A.2 Schematic Diagram of Suspension Dust Test Chamber . 27
Annex B (informative): Bibliography . 29
History . 30
ETSI
4 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables (European Standard (EN), Technical Specification (TS),
Group Specification (GS) or ETSI Standard (ES)) may have been declared to ETSI. The declarations pertaining to these
essential IPRs, if any, are publicly available for ETSI members and non-members, and can be found in
ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 2, sub part 3 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Part 2: "Specification of environmental tests": (see note 2)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
ETSI
5 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
National transposition dates
Date of adoption of this EN: 30 September 2026
Date of latest announcement of this EN (doa): 31 December 2026
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2027
Date of withdrawal of any conflicting National Standard (dow): 30 June 2027
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
6 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the
environmental conditions stated in ETSI EN 300 019-1-3 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3 (V3.1.1) (2026): "Environmental Engineering (EE); Environmental
conditions and environmental tests for telecommunications equipment; Part 1: Classification of
environmental conditions; Sub-part 3: Stationary use at weatherprotected locations".
[2] IEC 60068-2-1:2025: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[3] Void.
[4] IEC 60721-3-3:2019: "Classification of environmental conditions - Part 3-3: Classification of
groups of environmental parameters and their severities - Stationary use at weatherprotected
locations".
[5] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[6] IEC 60068-2-2:2025: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[7] IEC 60068-2-14:2023: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-78:2025: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[9] IEC 60068-2-30:2025: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[10] IEC 60068-2-64:2008+AMD1:2019: "Environmental testing - Part 2-64: Tests - Test Fh:
Vibration, broadband random and guidance".
[11] Void.
[12] IEC 60068-2-57:2013: "Environmental testing - Part 2-57: Tests - Test Ff: Vibration -
Time-history and sine-beat method".
[13] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[14] IEC 60068-2-13:2021: "Environmental testing - Part 2-13: Tests - Test M: Low air pressure".
[15] IEC 60068-2-18:2017: "Environmental testing - part 2-18: Tests - Test R and guidance: Water".
ETSI
7 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
[16] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
[i.2] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2: Specification of environmental
tests; Sub-part 0: Introduction".
[i.3] ISO 9226:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Determination
of corrosion rate of standard specimens for the evaluation of corrosivity".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the terms given in ETSI EN 300 019-1-0 [i.1] apply.
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ASD Acceleration Spectral Density
HF Hydrogen Fluoride
PCB Printed Circuit Board
RMS Root Mean Square
RRS Required Response Spectrum
ZPA Zero Period Acceleration
ETSI
8 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
4 Environmental test specifications
4.0 General
The equipment shall be tested in its operational state throughout the test conditions described in the present document.
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-3 [1].
ETSI EN 300 019-2-0 [i.2] forms a general overview of part 2 of this multi-part deliverable.
4.1 Equipment setup and configuration
The equipment shall be tested in its operational state throughout the test conditions described in the present document
unless otherwise stated. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
4.2 Performance criteria
The following performance criteria shall apply in tests defined by the present document.
Performance criterion A:
The equipment shall function according to the manufacturer specifications before, during and after the tests. No
degradation of performance or loss of function is allowed below the performance level specified by the manufacturer
when the equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then
this may be deduced from the product description and documentation and what the user may reasonably expect from the
equipment if used as intended.
Performance criterion B:
The equipment shall function according to the manufacturer specifications before and after the tests. During the test it is
not required to monitor the equipment functionality. No degradation of performance or loss of function is allowed
below the performance level specified by the manufacturer when the equipment is used as intended. If the minimum
performance level is not specified by the manufacturer, then this may be deduced from the product description and
documentation and what the user may reasonably expect from the equipment if used as intended.
Performance criterion C:
The equipment shall function according to the manufacturer specifications before and after the tests. No degradation of
performance or loss of function is allowed below the performance level specified by the manufacturer when the
equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then this may be
deduced from the product description and documentation and what the user may reasonably expect from the equipment
if used as intended. During the application of the test, temporary loss of function is allowed but after the test the
equipment shall restore to the normal functionality without replacement of components, manual rebooting or human
intervention. The equipment shall sustain the test without permanent structural or mechanical damage.
Performance criterion D:
This performance criterion applies to the enclosure of the equipment. No corrosion traces (e.g. rust) or deterioration of
the enclosure shall occur at the end of the test.
ETSI
9 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no
humidity control
Specification T 3.10: Temperature-controlled enclosed locations having no humidity control - normal operating conditions.
The specification in table 1, table 2 and table 3 shall apply to temperature-controlled enclosed locations where humidity is usually not controlled.
Table 1: Test specification T 3.10: Temperature-controlled enclosed locations - climatic tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
Low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad/Ae: Cold A 1
High (°C) +40 +40 or +50 16 h IEC 60068-2-2 [6] Bb/Bd/Be: Dry heat A 2
Air
(°C) +5 to+40 2 cycles IEC 60068-2-14 [7] Nb: Change of A 3
temperature
Change
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 None 4
high (%) 85 85 4 d IEC 60068-2-78 [8] Cab: Damp heat A 5
Relative
(°C) +30 steady state
Humidity
condensation No None
1 None 4
low (g/m )
Absolute
25 None 7
high (g/m )
low (kPa) 70 70 2 h IEC 60068-2-13 [14] Test M: Low air A 8
pressure
Pressure
Air
high (kPa) 106 None 8
Speed (m/s) 1,0 None 4
Intensity No None
Rain
low temperature No None
Other No None
Water
sources
Icing & No None
frosting
Solar 700 None 9
(W/m )
Radiation
Heat 600 None 10
(W/m )
ETSI
10 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
[16] None 11
SO (mg/m )
Sulphur
[16] None 11
HS (mg/m )
salt mist [16] None 11
[16] None 11
Chlorine Cl (mg/m )
Chemically
[16] None 11
HCI (mg/m )
active
[16] None 11
NO (mg/m )
x
substances
Nitrogen
[16] None 11
NH (mg/m )
Hydrogen [16] None 11
(mg/m )
fluoride HF
Ozone O [16] None 11
(mg/m )
sedimentation 6 12
Mechanically
Dust (mg/(m d))
active
no None
suspension (mg/m )
substances
no None
Sand
(mg/m )
Micro organisms negligible
Flora and
fauna Rodents, insects negligible
ETSI
11 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
NOTE 1: (Air temperature, low).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If a cold start up test is performed, the characteristic severity should be used as a cold start up temperature, but it may be modified (within the class characteristic
severity range) by the product specification. In this case, the cold start up test shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If two test temperatures are given, the lower test temperature applies if the equipment is protected against solar and heat radiation or the equipment is ventilated
(natural or forced). The higher test temperature includes the heating effects of solar and/or heat radiation. If a high temperature start up test is performed, the
characteristic severity should be used as a high start up temperature, but it may be modified (within the class characteristic severity range) by the product
specification. In this case, the high temperature start up test shall commence once high temperature stability is achieved.
NOTE 3: (Air temperature, change).
The change of temperature test is normally used to check design tolerance. IEC 60068-2-14 [7] Test Nb shall be used. For change of temperature of 0,5 °C/min,
the cooling gradient may be reduced to 0,2 °C/min where test chamber restrictions preclude a gradient of 0,5 °C/min.
NOTE 4: (Relative humidity, low).
There is no IEC 60068-2 series test method for this parameter.
NOTE 5: (Humidity, relative, high).
IEC 60068-2-78 [8] Test Cab shall be used with test values not higher than climatogram limits for this class.
NOTE 6: Void.
NOTE 7: (Humidity, absolute, high).
This effect is considered to be partly included in the damp heat test IEC 60068-2-78 [8] Test Cab.
NOTE 8: (Air pressure, low and high).
No test is recommended for normal applications, because the effect of air pressure is evaluated at the component level. For sealed products or for products
containing liquids, test M is recommended.
NOTE 9: (Radiation, solar).
The higher test temperature as described in note 2 includes the heating effect of solar radiation. Photochemical tests can be made separately for components
and materials.
NOTE 10: (Radiation, heat).
The higher test temperature as described in note 2 includes the heating effect.
NOTE 11: (Chemically active substances).
The characteristic severities are given in ISO 9223 [16]. For the chemically active substances, no specific tests are defined but they should be considered in the
design phase. The following references provide guidance for the design:
- ISO 9223:2012 [16]: this can be used to calculate the corrosion losses of standard metals.
- ISO 9226:2012 [i.3]: this can be used to determine corrosion losses of standard specimens.
NOTE 12: (Mechanically active substances).
The characteristic severities are much lower than lowest test severity in IEC 60068-2-68 [13] Test L and therefore no test is recommended. This condition should
be considered when designing the equipment and when choosing components and materials.
ETSI
12 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Table 2: Test specification T 3.10: Temperature-controlled enclosed locations having no humidity control - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail Characteristic Test severity Duration Reference Method Performance Notes
parameter severity criteria
2 2
Vibration Random acceleration spectral 0,01 30 minutes in IEC 60068-2-64 [10] Test Fh: A See note
0,01 (m/s ) /Hz
2 2
each Vibration,
density ((m/s ) /Hz)
direction broadband
5 Hz to 100 Hz
Frequency (Hz) 5 to 200
random
Shocks Shocks No
acceleration (m/s )
NOTE: (Vibration, random).
The test severity values are not specified in IEC 60068-2 series. The maximum test frequency has been reduced to 100 Hz, because between 100 Hz and 200 Hz
the contribution is insignificant.
Also at low and high frequency ends the ASD is reduced by 12 dB/octave.
Classes: 3.11/3.12
Acceleration RMS
1,06 m/s
(for information only)
Equipment under test shall be mounted in the "in-use" position. The equipment function shall be monitored throughout the test.
ETSI
13 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Specification T 3.10E: Temperature-controlled enclosed locations having no humidity control - exceptional operating conditions.
The specification in table 3 shall apply to temperature-controlled enclosed locations where humidity is usually not controlled. The reference class is the same as for T 3.10, but
with extended temperature and humidity ranges.
Table 3: Test specification T 3.10E: Temperature-controlled enclosed locations, exceptional operating conditions - climatic tests
Environmental parameter Environme
...
SLOVENSKI STANDARD
01-december-2026
Okoljski inženiring (EE) - Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo - 2-3. del: Specifikacija preskusov vplivov okolja -
Stacionarna uporaba na lokacijah, zaščitenih pred vremenskimi vplivi
Environmental Engineering (EE) - Environmental conditions and environmental tests for
telecommunications equipment - Part 2-3: Specification of environmental tests - Sub-part
3: Stationary use at weatherprotected locations
Ta slovenski standard je istoveten z: ETSI EN 300 019-2-3 V3.1.1 (2026-10)
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2: Specification of environmental tests;
Sub-part 3: Stationary use at weatherprotected locations
2 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Reference
REN/EE-017016
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part of this document may be reproduced in any form, by any means and in any media, without the prior written
authorization of ETSI and except as expressly permitted below.
By way of exception and when the document is a normative deliverable (European Standard (EN),
Technical Specification (TS), Group Specification (GS) or ETSI Standard (ES)), ETSI authorizes to reproduce
and incorporate into products, services and technical documentation only those extracts (e.g. templates) that are strictly
necessary for the technical implementation of the normative deliverable, to ensure compliance with the latter.
Nothing in this notice shall be construed as limiting any mandatory exceptions to copyright provided by applicable law.
© ETSI 2026.
All rights reserved.
ETSI
3 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 7
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental test specifications . 8
4.0 General . 8
4.1 Equipment setup and configuration . 8
4.2 Performance criteria . 8
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no humidity
control . 9
4.4 Specification T 3.11: Enclosed locations having no temperature or humidity control . 15
4.5 Specification T 3.12: Locations having neither temperature nor humidity control . 18
5 Earthquake test specification . 23
5.0 General . 23
5.1 Vibration response investigation . 23
5.2 Test conditioning . 24
Annex A (informative): Impact of corrosion due to dust . 26
A.0 General . 26
A.1 Test condition . 26
A.1.0 Introduction . 26
A.1.1 Dust test condition . 26
A.1.2 Corrosion test . 26
A.1.3 Pass criteria . 26
A.2 Schematic Diagram of Suspension Dust Test Chamber . 27
Annex B (informative): Bibliography . 29
History . 30
ETSI
4 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables (European Standard (EN), Technical Specification (TS),
Group Specification (GS) or ETSI Standard (ES)) may have been declared to ETSI. The declarations pertaining to these
essential IPRs, if any, are publicly available for ETSI members and non-members, and can be found in
ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 2, sub part 3 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Part 2: "Specification of environmental tests": (see note 2)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
ETSI
5 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
National transposition dates
Date of adoption of this EN: 30 September 2026
Date of latest announcement of this EN (doa): 31 December 2026
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2027
Date of withdrawal of any conflicting National Standard (dow): 30 June 2027
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
6 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests in the present document apply to stationary use of equipment at weatherprotected locations covering the
environmental conditions stated in ETSI EN 300 019-1-3 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3 (V3.1.1) (2026): "Environmental Engineering (EE); Environmental
conditions and environmental tests for telecommunications equipment; Part 1: Classification of
environmental conditions; Sub-part 3: Stationary use at weatherprotected locations".
[2] IEC 60068-2-1:2025: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[3] Void.
[4] IEC 60721-3-3:2019: "Classification of environmental conditions - Part 3-3: Classification of
groups of environmental parameters and their severities - Stationary use at weatherprotected
locations".
[5] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[6] IEC 60068-2-2:2025: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[7] IEC 60068-2-14:2023: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-78:2025: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[9] IEC 60068-2-30:2025: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[10] IEC 60068-2-64:2008+AMD1:2019: "Environmental testing - Part 2-64: Tests - Test Fh:
Vibration, broadband random and guidance".
[11] Void.
[12] IEC 60068-2-57:2013: "Environmental testing - Part 2-57: Tests - Test Ff: Vibration -
Time-history and sine-beat method".
[13] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[14] IEC 60068-2-13:2021: "Environmental testing - Part 2-13: Tests - Test M: Low air pressure".
[15] IEC 60068-2-18:2017: "Environmental testing - part 2-18: Tests - Test R and guidance: Water".
ETSI
7 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
[16] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
[i.2] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2: Specification of environmental
tests; Sub-part 0: Introduction".
[i.3] ISO 9226:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Determination
of corrosion rate of standard specimens for the evaluation of corrosivity".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the terms given in ETSI EN 300 019-1-0 [i.1] apply.
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ASD Acceleration Spectral Density
HF Hydrogen Fluoride
PCB Printed Circuit Board
RMS Root Mean Square
RRS Required Response Spectrum
ZPA Zero Period Acceleration
ETSI
8 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
4 Environmental test specifications
4.0 General
The equipment shall be tested in its operational state throughout the test conditions described in the present document.
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-3 [1].
ETSI EN 300 019-2-0 [i.2] forms a general overview of part 2 of this multi-part deliverable.
4.1 Equipment setup and configuration
The equipment shall be tested in its operational state throughout the test conditions described in the present document
unless otherwise stated. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
4.2 Performance criteria
The following performance criteria shall apply in tests defined by the present document.
Performance criterion A:
The equipment shall function according to the manufacturer specifications before, during and after the tests. No
degradation of performance or loss of function is allowed below the performance level specified by the manufacturer
when the equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then
this may be deduced from the product description and documentation and what the user may reasonably expect from the
equipment if used as intended.
Performance criterion B:
The equipment shall function according to the manufacturer specifications before and after the tests. During the test it is
not required to monitor the equipment functionality. No degradation of performance or loss of function is allowed
below the performance level specified by the manufacturer when the equipment is used as intended. If the minimum
performance level is not specified by the manufacturer, then this may be deduced from the product description and
documentation and what the user may reasonably expect from the equipment if used as intended.
Performance criterion C:
The equipment shall function according to the manufacturer specifications before and after the tests. No degradation of
performance or loss of function is allowed below the performance level specified by the manufacturer when the
equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then this may be
deduced from the product description and documentation and what the user may reasonably expect from the equipment
if used as intended. During the application of the test, temporary loss of function is allowed but after the test the
equipment shall restore to the normal functionality without replacement of components, manual rebooting or human
intervention. The equipment shall sustain the test without permanent structural or mechanical damage.
Performance criterion D:
This performance criterion applies to the enclosure of the equipment. No corrosion traces (e.g. rust) or deterioration of
the enclosure shall occur at the end of the test.
ETSI
9 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
4.3 Specifications T 3.10 and T 3.10E: Temperature-controlled enclosed locations having no
humidity control
Specification T 3.10: Temperature-controlled enclosed locations having no humidity control - normal operating conditions.
The specification in table 1, table 2 and table 3 shall apply to temperature-controlled enclosed locations where humidity is usually not controlled.
Table 1: Test specification T 3.10: Temperature-controlled enclosed locations - climatic tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
Low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad/Ae: Cold A 1
High (°C) +40 +40 or +50 16 h IEC 60068-2-2 [6] Bb/Bd/Be: Dry heat A 2
Air
(°C) +5 to+40 2 cycles IEC 60068-2-14 [7] Nb: Change of A 3
temperature
Change
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 None 4
high (%) 85 85 4 d IEC 60068-2-78 [8] Cab: Damp heat A 5
Relative
(°C) +30 steady state
Humidity
condensation No None
1 None 4
low (g/m )
Absolute
25 None 7
high (g/m )
low (kPa) 70 70 2 h IEC 60068-2-13 [14] Test M: Low air A 8
pressure
Pressure
Air
high (kPa) 106 None 8
Speed (m/s) 1,0 None 4
Intensity No None
Rain
low temperature No None
Other No None
Water
sources
Icing & No None
frosting
Solar 700 None 9
(W/m )
Radiation
Heat 600 None 10
(W/m )
ETSI
10 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
[16] None 11
SO (mg/m )
Sulphur
[16] None 11
HS (mg/m )
salt mist [16] None 11
[16] None 11
Chlorine Cl (mg/m )
Chemically
[16] None 11
HCI (mg/m )
active
[16] None 11
NO (mg/m )
x
substances
Nitrogen
[16] None 11
NH (mg/m )
Hydrogen [16] None 11
(mg/m )
fluoride HF
Ozone O [16] None 11
(mg/m )
sedimentation 6 12
Mechanically
Dust (mg/(m d))
active
no None
suspension (mg/m )
substances
no None
Sand
(mg/m )
Micro organisms negligible
Flora and
fauna Rodents, insects negligible
ETSI
11 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail parameter Characteristic Test Duration Reference Method Performance Notes
severity severity criteria
NOTE 1: (Air temperature, low).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If a cold start up test is performed, the characteristic severity should be used as a cold start up temperature, but it may be modified (within the class characteristic
severity range) by the product specification. In this case, the cold start up test shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high).
The equipment under test shall remain operational throughout this test (without any damage or deterioration of performance, according to product specification).
If two test temperatures are given, the lower test temperature applies if the equipment is protected against solar and heat radiation or the equipment is ventilated
(natural or forced). The higher test temperature includes the heating effects of solar and/or heat radiation. If a high temperature start up test is performed, the
characteristic severity should be used as a high start up temperature, but it may be modified (within the class characteristic severity range) by the product
specification. In this case, the high temperature start up test shall commence once high temperature stability is achieved.
NOTE 3: (Air temperature, change).
The change of temperature test is normally used to check design tolerance. IEC 60068-2-14 [7] Test Nb shall be used. For change of temperature of 0,5 °C/min,
the cooling gradient may be reduced to 0,2 °C/min where test chamber restrictions preclude a gradient of 0,5 °C/min.
NOTE 4: (Relative humidity, low).
There is no IEC 60068-2 series test method for this parameter.
NOTE 5: (Humidity, relative, high).
IEC 60068-2-78 [8] Test Cab shall be used with test values not higher than climatogram limits for this class.
NOTE 6: Void.
NOTE 7: (Humidity, absolute, high).
This effect is considered to be partly included in the damp heat test IEC 60068-2-78 [8] Test Cab.
NOTE 8: (Air pressure, low and high).
No test is recommended for normal applications, because the effect of air pressure is evaluated at the component level. For sealed products or for products
containing liquids, test M is recommended.
NOTE 9: (Radiation, solar).
The higher test temperature as described in note 2 includes the heating effect of solar radiation. Photochemical tests can be made separately for components
and materials.
NOTE 10: (Radiation, heat).
The higher test temperature as described in note 2 includes the heating effect.
NOTE 11: (Chemically active substances).
The characteristic severities are given in ISO 9223 [16]. For the chemically active substances, no specific tests are defined but they should be considered in the
design phase. The following references provide guidance for the design:
- ISO 9223:2012 [16]: this can be used to calculate the corrosion losses of standard metals.
- ISO 9226:2012 [i.3]: this can be used to determine corrosion losses of standard specimens.
NOTE 12: (Mechanically active substances).
The characteristic severities are much lower than lowest test severity in IEC 60068-2-68 [13] Test L and therefore no test is recommended. This condition should
be considered when designing the equipment and when choosing components and materials.
ETSI
12 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Table 2: Test specification T 3.10: Temperature-controlled enclosed locations having no humidity control - mechanical tests
Environmental parameter Environmental Environmental test specification T 3.10: In-use,
Class 3.10 Temperature-controlled enclosed locations
Type Parameter Detail Characteristic Test severity Duration Reference Method Performance Notes
parameter severity criteria
2 2
Vibration Random acceleration spectral 0,01 30 minutes in IEC 60068-2-64 [10] Test Fh: A See note
0,01 (m/s ) /Hz
2 2
each Vibration,
density ((m/s ) /Hz)
direction broadband
5 Hz to 100 Hz
Frequency (Hz) 5 to 200
random
Shocks Shocks No
acceleration (m/s )
NOTE: (Vibration, random).
The test severity values are not specified in IEC 60068-2 series. The maximum test frequency has been reduced to 100 Hz, because between 100 Hz and 200 Hz
the contribution is insignificant.
Also at low and high frequency ends the ASD is reduced by 12 dB/octave.
Classes: 3.11/3.12
Acceleration RMS
1,06 m/s
(for information only)
Equipment under test shall be mounted in the "in-use" position. The equipment function shall be monitored throughout the test.
ETSI
13 ETSI EN 300 019-2-3 V3.1.1 (2026-10)
Specification T 3.10E: Temperature-controlled enclosed locatio
...