Leather -- Physical testing -- Measurement of thickness

Specification of apparatus, pre-conditioning of the test pieces, procedure and test report. This method is applicable to all kinds of leather, of any type of tannage, except for firm leathers of thickness 3 mm or greater. This measurement is valid for both the whole leather and a test sample.

Cuir -- Essais physiques -- Mesurage de l'épaisseur

Usnje - Fizikalno preskušanje - Merjenje debeline

General Information

Status
Withdrawn
Publication Date
31-Mar-1998
Withdrawal Date
31-Jan-2003
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-Feb-2003
Due Date
01-Feb-2003
Completion Date
01-Feb-2003

Relations

Buy Standard

Standard
ISO 2589:1972 - Leather -- Physical testing -- Measurement of thickness
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2589:1998
English language
2 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 2589:1972 - Cuir -- Essais physiques -- Mesurage de l'épaisseur
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2589:1972 - Cuir -- Essais physiques -- Mesurage de l'épaisseur
French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

~~~~~ --
INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXflYHAPOAHAR OPl-AHM3AL@iII I-IO CTAHAAPTM3ALJMW .ORGANISATION INTERNATIONALE DE NORMALISATION
Leather - Physical testing - Measurement of thickness
First edition - 1972-12-15
UDC 675 : 531.717 Ref. No. IS0 2589-1972 (E)
Descriptors : animal products, leather, tests, physical tests, dimensional measurement, thickness.
Price based on 2 pages

---------------------- Page: 1 ----------------------
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and nongovernmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 2589 was drawn up by Technical Committee
lSO/TC 120, Leather.
It was approved in May 1972 by the Member Bodies of the following countries :
Australia Hungary Romania
Brazi I India South Africa, Rep. of
Chile Iran Spain
Czechoslovakia Ireland Thai land
Egypt, Arab Rep. of Israel Turkey
France New Zealand United Kingdom
Germany Poland U.S.S.R.
No Member Body expressed disapproval of the document.
This International Standard is based on method IUP/ of the International Union
of Leather Chemists’ Societies.
0 International Organization for Standardization, 1972 l
Printed in Switzerland

---------------------- Page: 2 ----------------------
IS0 2589-1972 (E)
INTERNATIONAL STANDARD
Leather - Physical testing - Measurement of thickness
3.3 Presser foot, having a flat, circular surface of 10 mm
0 INTRODUCTION
diameter, coaxial with the anvil, and capable of movement
The measured thickness of a leather depends upon such
normal to the face of the anvil. The contacting surfaces of
factors as the pressure and the time for which pressure is
the anvil and presser foot shall be parallel to within
applied. It is recognized that the thicknesses of certain
0,005 mm for all positions of the presser foot. The presser
leathers, if measured at zero load or small loads, would
foot shall be dead weight loaded with 390 f 10 g (equiv-
differ materially from those obtained by measurements
alent to about 49 kN/m*.
made in accordance with this International Standard. It is
recommended, however, that the thickness of a leather,
3.4 Rigid stand.
unless otherwise specified, should be accepted as being that
found by the method described b
...

SLOVENSKI STANDARD
SIST ISO 2589:1998
01-april-1998
Usnje - Fizikalno preskušanje - Merjenje debeline
Leather -- Physical testing -- Measurement of thickness
Cuir -- Essais physiques -- Mesurage de l'épaisseur
Ta slovenski standard je istoveten z: ISO 2589:1972
ICS:
59.140.30 Usnje in krzno Leather and furs
SIST ISO 2589:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 2589:1998

---------------------- Page: 2 ----------------------

SIST ISO 2589:1998
~~~~~ --
INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXflYHAPOAHAR OPl-AHM3AL@iII I-IO CTAHAAPTM3ALJMW .ORGANISATION INTERNATIONALE DE NORMALISATION
Leather - Physical testing - Measurement of thickness
First edition - 1972-12-15
UDC 675 : 531.717 Ref. No. IS0 2589-1972 (E)
Descriptors : animal products, leather, tests, physical tests, dimensional measurement, thickness.
Price based on 2 pages

---------------------- Page: 3 ----------------------

SIST ISO 2589:1998
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and nongovernmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 2589 was drawn up by Technical Committee
lSO/TC 120, Leather.
It was approved in May 1972 by the Member Bodies of the following countries :
Australia Hungary Romania
Brazi I India South Africa, Rep. of
Chile Iran Spain
Czechoslovakia Ireland Thai land
Egypt, Arab Rep. of Israel Turkey
France New Zealand United Kingdom
Germany Poland U.S.S.R.
No Member Body expressed disapproval of the document.
This International Standard is based on method IUP/ of the International Union
of Leather Chemists’ Societies.
0 International Organization for Standardization, 1972 l
Printed in Switzerland

---------------------- Page: 4 ----------------------

SIST ISO 2589:1998
IS0 2589-1972 (E)
INTERNATIONAL STANDARD
Leather - Physical testing - Measurement of thickness
3.3 Presser foot, having a flat, circular surface of 10 mm
0 INTRODUCTION
diameter, coaxial with the anvil, and capable of movement
The measured thickness of a leather depends upon such
normal to the face of the anvil. The contacting surfaces of
factors as the pressure and the time for which pressure is
the anvil and presser foot shall be parallel to within
applied. It is recognized that the thicknesses of certain
0,005 mm for all positions of the presser foot. The presser
leathers, if measured at zero load or small loads, would
foot shall be dead weight loaded with 390 f 10 g (equiv-
...

NORME INTERNATIONALE
.ORGANISATION INTERNATIONALE DE NORMALISATION
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .MEXAYHAPOflHAR OPTAHM3ALQiN IlO CTAH~APTM3AL@iM
Essais physiques - Mesurage de l’épaisseur
Cuir -
Première édition - 1972-12-15
Réf. No : ISO 2589-1972 (F)
CDU 675 : 531.717
Descripteurs : produit animal, cuir, essai, essai physique, mesure de dimension, épaisseur.
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres KO). L’élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2589 a été établie par le Comité Technique
ISO/TC 120, Cuir.
Elle fut approuvée en mai 1972 par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d’ France Pologne
Allemagne Hongrie Roumanie
Australie Inde Royaume-Uni
Brési I Iran Tchécoslovaquie
Chili Irlande Thaïlande
Egypte, Rép. arabe d’ Israël Turquie
Espagne Nouvelle-Zélande U.R.S.S.
Aucun Comité Membre n’a désapprouvé le document.
La pr st basée sur la méthode lUP/4 de l’Union
Gsente Norme I nternatio nale e
I ntern ationale des Sociétés de chimi stes du cuir.
0 Organisation Internationale de Normalisation, 1972 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
ISO 2589-1972 (F)
NORME INTERNATIONALE
- Essais physiques -
Cuir Mesurage de l’épaisseur
0 INTRODUCTION
3.3 Pied presseur, plat, circulaire, de diamètre 10 mm,
coaxial à l’enclume et se déplacant perpendiculairement à la
L’épaisseur d’un cuir dépend de facteurs tels que la pression
surface de tel le-ci. Les faces du pied presseur et de
et le temps durant lequel celle-ci est exercée. II est reconnu
l’enclume doivent être parallèles pour toutes les positions
que, pour certains cuirs, l’épaisseur mesurée sous une charge
verticales du pied, l’erreur éventuelle sur leur parallélisme
nulle ou faible, peut différer sensiblement de celle obtenue
ne devant jamais dépasser 0,005 mm. Le pied presseur doit
en mesurant selon la présente Norme Internationale. II est
être chargé d’une masse
inerte de 390 f 10 g, ce qui
recommandé, toutefois, d’admettre que, sauf spécification
équivaut à une pression d’environ 49 kN/m?
contraire, I ‘épaisseur d’un cuir soit celle trouvée en
appliquant la méthode décrite ci-dessous.
3.4 Support rigide.
‘i OBJET
La présente Norme Internationale fixe une méthode de
4 CONDITIONNEMENT
mesurage de l’épaisseur du cuir.
Dans tous les cas où la plus grande précision pos
...

NORME INTERNATIONALE
.ORGANISATION INTERNATIONALE DE NORMALISATION
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .MEXAYHAPOflHAR OPTAHM3ALQiN IlO CTAH~APTM3AL@iM
Essais physiques - Mesurage de l’épaisseur
Cuir -
Première édition - 1972-12-15
Réf. No : ISO 2589-1972 (F)
CDU 675 : 531.717
Descripteurs : produit animal, cuir, essai, essai physique, mesure de dimension, épaisseur.
Prix basé sur 2 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres KO). L’élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2589 a été établie par le Comité Technique
ISO/TC 120, Cuir.
Elle fut approuvée en mai 1972 par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d’ France Pologne
Allemagne Hongrie Roumanie
Australie Inde Royaume-Uni
Brési I Iran Tchécoslovaquie
Chili Irlande Thaïlande
Egypte, Rép. arabe d’ Israël Turquie
Espagne Nouvelle-Zélande U.R.S.S.
Aucun Comité Membre n’a désapprouvé le document.
La pr st basée sur la méthode lUP/4 de l’Union
Gsente Norme I nternatio nale e
I ntern ationale des Sociétés de chimi stes du cuir.
0 Organisation Internationale de Normalisation, 1972 l
Imprimé en Suisse

---------------------- Page: 2 ----------------------
ISO 2589-1972 (F)
NORME INTERNATIONALE
- Essais physiques -
Cuir Mesurage de l’épaisseur
0 INTRODUCTION
3.3 Pied presseur, plat, circulaire, de diamètre 10 mm,
coaxial à l’enclume et se déplacant perpendiculairement à la
L’épaisseur d’un cuir dépend de facteurs tels que la pression
surface de tel le-ci. Les faces du pied presseur et de
et le temps durant lequel celle-ci est exercée. II est reconnu
l’enclume doivent être parallèles pour toutes les positions
que, pour certains cuirs, l’épaisseur mesurée sous une charge
verticales du pied, l’erreur éventuelle sur leur parallélisme
nulle ou faible, peut différer sensiblement de celle obtenue
ne devant jamais dépasser 0,005 mm. Le pied presseur doit
en mesurant selon la présente Norme Internationale. II est
être chargé d’une masse
inerte de 390 f 10 g, ce qui
recommandé, toutefois, d’admettre que, sauf spécification
équivaut à une pression d’environ 49 kN/m?
contraire, I ‘épaisseur d’un cuir soit celle trouvée en
appliquant la méthode décrite ci-dessous.
3.4 Support rigide.
‘i OBJET
La présente Norme Internationale fixe une méthode de
4 CONDITIONNEMENT
mesurage de l’épaisseur du cuir.
Dans tous les cas où la plus grande précision pos
...