Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
This European Standard applies to polychloroprene, or other equivalent synthetic elastomer, sheathed cables. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for use as decorative chains and with designated lampholders. NOTE 1 Cables to Type H03RN-F are for use with designated lampholders only. The 0,5 mm2 size is for use with miniaturised lampholders; the 0,75 mm2 size is for use with E 14 lampholders. See also HD 516. The maximum conductor operating temperature for each of the cables in this standard is 60 °C. NOTE 2 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-82 should be read in conjunction with EN 50525-1, which specifies general requirements.
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-82: Starkstromleitungen für allgemeine Anwendungen - Leitungen für Lichterketten mit vernetzter Elastomer-Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 2-82: Câbles pour applications générales - Câbles pour guirlandes lumineuses isolés en matériau élastomère réticulé
Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V (U0/U) - 2-82. del: Kabli za splošno uporabo - Kabli z zamreženo elastomerno izolacijo za okrasne verige
Ta evropski standard velja za kable, oplaščene s polikloroprenom ali drugim ustreznim sintetičnim elastomerom. Ti kabli imajo nazivno napetost U0/U do vključno 300/500 V. Kabli se uporabljajo kot okrasne verige in z določenimi okovi za žarnice in sijalke.
General Information
- Status
- Published
- Public Enquiry End Date
- 28-Feb-2009
- Publication Date
- 12-Jun-2011
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Jun-2011
- Due Date
- 13-Aug-2011
- Completion Date
- 13-Jun-2011
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
- Effective Date
- 07-Jun-2022
- Effective Date
- 06-Jan-2009
- Effective Date
- 06-Jan-2009
- Effective Date
- 06-Jan-2009
Overview
SIST EN 50525-2-82:2011 is a European Standard published by CLC for low voltage energy cables designed specifically for decorative chains and associated lampholders. The standard applies to cables with crosslinked elastomeric insulation and sheathing, rated for voltages up to and including 300/500 V (U₀/U). These cables use polychloroprene or equivalent synthetic elastomers for effective electrical insulation and mechanical protection. Key focus is on cables suited for decorative lighting such as string lights, with detailed specifications for different cable types (e.g., H03RN-F, H05RN-F).
The document complements EN 50525-1, which sets out general requirements for low voltage cables, providing additional technical details important for manufacturers, designers, and end-users involved in decorative lighting applications.
Key Topics
Cable Types and Constructions
- H03RN-F: Single conductor cables (0.5 mm² or 0.75 mm²), targeted for miniaturised and E14 lampholders.
- H05RN-F & H05RNH2-F: Single core (0.75 mm² to 1.5 mm²) and two-core flat cables (1.5 mm² or 2.5 mm²) for general decorative lighting applications.
Materials
- Insulation and sheath are made from crosslinked elastomeric compounds conforming to EN 50363-1 (Type EI 4 for insulation) and EN 50363-2-1 (Type EM 2 for sheathing).
- Use of polychloroprene or similar elastomeric materials provides excellent flexibility, weather resistance, and durability.
Electrical and Mechanical Requirements
- Rated conductor temperature max: 60 °C.
- Conductors are Class 5 flexible copper wires per EN 60228.
- Extensive electrical tests including resistance, voltage withstand, insulation integrity, and sheath surface resistance are specified.
- Mechanical tests cover abrasion resistance, impact at low temperature, and flexibility requirements.
Marking and Identification
- Cables are marked clearly with CENELEC codes (e.g., H03RN-F) on the sheath surface to ensure traceability and compliance.
- Core color coding for multi-core cables is specified for safety and identification (e.g., brown and blue).
Compatibility and Safety
- Aging tests at 80 ± 2 °C for 7 days to ensure material stability, mechanical strength, and insulation integrity.
- Axial dimensions and conductor spacing requirements follow EN 60719.
- This standard refers to HD 516 for comprehensive guidance on safe cable usage in domestic and decorative lighting.
Applications
SIST EN 50525-2-82:2011 cables are primarily used in:
Decorative Lighting Chains
Used in indoor and outdoor decorative lighting setups like Christmas light chains, festival lighting, and other ornamental installations.Designated Lampholders
Specifically compatible with miniaturized lampholders and E14 types, guiding correct conductor sizing for safety and performance.Flexible Low Voltage Installations
Adapted for applications requiring flexibility, abrasion resistance, and adequate insulation at lower voltages, suitable for temporary or permanent decorative lighting.
These cables ensure safety, durability, and compliance with European safety regulations, providing manufacturers and installers a reliable basis for product development and certification.
Related Standards
- EN 50525-1: General requirements for low voltage energy cables up to 450/750 V - foundational for understanding the overall performance criteria and testing methods.
- EN 50363-1 & EN 50363-2-1: Specify insulating and sheathing materials for low voltage cables, focusing on crosslinked elastomeric compounds.
- EN 60228: Defines conductor classes and requirements, critical for conductor flexibility and conductivity.
- EN 60332-1-2: Fire safety tests related to flame propagation on cables.
- EN 60811-1-2 and EN 60811-1-4: Test methods for thermal aging and low temperature mechanical properties of sheath and insulation materials.
- HD 516: A guide on the safe use of harmonized low voltage cables, which is vital for applying the EN 50525 series standards effectively.
Keywords: SIST EN 50525-2-82:2011, low voltage energy cables, decorative chains cables, crosslinked elastomeric insulation, polychloroprene cables, CENELEC standard, H03RN-F, H05RN-F, lampholders, flexible low voltage cables, European cable standards, cable testing, safe decorative lighting cables.
Frequently Asked Questions
SIST EN 50525-2-82:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains". This standard covers: This European Standard applies to polychloroprene, or other equivalent synthetic elastomer, sheathed cables. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for use as decorative chains and with designated lampholders. NOTE 1 Cables to Type H03RN-F are for use with designated lampholders only. The 0,5 mm2 size is for use with miniaturised lampholders; the 0,75 mm2 size is for use with E 14 lampholders. See also HD 516. The maximum conductor operating temperature for each of the cables in this standard is 60 °C. NOTE 2 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-82 should be read in conjunction with EN 50525-1, which specifies general requirements.
This European Standard applies to polychloroprene, or other equivalent synthetic elastomer, sheathed cables. The cables are of rated voltages U0/U up to and including 300/500 V. The cables are intended for use as decorative chains and with designated lampholders. NOTE 1 Cables to Type H03RN-F are for use with designated lampholders only. The 0,5 mm2 size is for use with miniaturised lampholders; the 0,75 mm2 size is for use with E 14 lampholders. See also HD 516. The maximum conductor operating temperature for each of the cables in this standard is 60 °C. NOTE 2 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-82 should be read in conjunction with EN 50525-1, which specifies general requirements.
SIST EN 50525-2-82:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50525-2-82:2011 has the following relationships with other standards: It is inter standard links to SIST HD 22.8 S2:1998/A1:1999, SIST HD 22.8 S2:1998, SIST HD 22.8 S2:1998/A2:2004, SIST HD 22.8 S2:1998/A2:2004, SIST HD 22.8 S2:1998, SIST HD 22.8 S2:1998/A1:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 50525-2-82:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 50525-2-82:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR988GHO.DEOL]DVSORãQRXSRUDER.DEOL]]DPUHåHQR
HODVWRPHUQRL]RODFLMR]DRNUDVQHYHULJH
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked
elastomeric insulation for decorative chains
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-82: Starkstromleitungen für allgemeine Anwendungen - Leitungen für Lichterketten
mit vernetzter Elastomer-Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 2-82: Câbles pour applications générales - Câbles pour
guirlandes lumineuses isolés en matériau élastomère réticulé
Ta slovenski standard je istoveten z: EN 50525-2-82:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50525-2-82
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 22.8 S2:1994 + A1:1999 + A2:2004
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 2-82: Cables for general applications -
Cables with crosslinked elastomeric insulation for decorative chains
Câbles électriques - Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) -
Teil 2-82: Starkstromleitungen für
Partie 2-82: Câbles pour applications allgemeine Anwendungen -
générales - Leitungen für Lichterketten mit vernetzter
Câbles pour guirlandes lumineuses isolés Elastomer-Isolierung
en matériau élastomère réticulé
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-82:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric
cables.
The text of the draft was submitted to the formal vote and was accepted by CENELEC as
EN 50525-2-82 on 2011-01-17.
This document, which is one of a multipart series, supersedes HD 22.8 S2:1994 + A1:1999 +
A2:2004.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17
____________
- 3 - EN 50525-2-82:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 General purpose cables . 5
4.1 Cables used with designated lampholders – H03RN-F . 5
4.2 Cables – H05RN-F and H05RNH2-F . 5
Annex A (normative) Tests for cables to EN 50525-2-82 . 7
Annex B (normative) General data . 8
Annex C (normative) Requirements for compatibility test . 9
C.1 Test conditions . 9
C.2 Requirements . 9
Bibliography . 10
Tables
Table A.1 . 7
Table B.1 ― General data for cable type H03RN-F . 8
Table B.2 ― General data for cable types H05RN-F AND H05RNH2-F . 8
Table C.1 ― Requirements . 9
1 Scope
This European Standard applies to polychloroprene, or other equivalent synthetic elastomer,
sheathed cables.
The cables are of rated voltages U /U up to and including 300/500 V.
The cables are intended for use as decorative chains and with designated lampholders.
NOTE 1 Cables to Type H03RN-F are for use with designated lampholders only. The 0,5 mm size is for use with
miniaturised lampholders; the 0,75 mm size is for use with E 14 lampholders. See also HD 516.
The maximum conductor operating temperature for each of the cables in this standard is
60 °C.
NOTE 2 HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN 50525-2-82 should be read in conjunction with EN 50525-1, which specifies general
requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
NOTE One or more references to the standards below are in respect of a specific sub-division of that standard,
for instance a clause, a table, a class or a type. Cross-references to these standards are undated and, at all times,
the latest version applies.
EN 50363-1 Insulating, sheathing and covering materials for low voltage
energy cables − Part 1: Cross-linked elastomeric insulating
compounds
EN 50363-2-1 Insulating, sheathing and covering materials for low voltage
energy cables − Part 2-1: Cross-linked elastomeric sheathing
compounds
EN 50395 Electrical test methods for low voltage energy cables
EN 50396
...