SIST EN 50525-3-41:2011
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
- Abstract
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
- Status
- Published
- Public Enquiry End Date
- 28-Feb-2009
- Publication Date
- 12-Jun-2011
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Jun-2011
- Due Date
- 13-Aug-2011
- Completion Date
- 13-Jun-2011
- Directive
- 2006/95/EC - Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (codified version)OJ Ref: C 348/03 OJ Date: 28-Nov-2013 Conflicting Date: 17-Jan-2014
2014/35/EU - Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limitsOJ Ref: C 249/03 OJ Date: 08-Jul-2016
SIST EN 50525-3-41:2011 is the Slovenian adoption of EN 50525-3-41:2011 from CENELEC. It specifies single-core, non-sheathed low-voltage energy cables with halogen-free crosslinked insulation, low smoke emission and low corrosive gas release for fixed wiring and internal wiring applications. The document is written for cable manufacturers, test laboratories, specifiers, installers and buyers who need to identify the right cable family and verify its performance.
What does SIST EN 50525-3-41:2011 specify?
SIST EN 50525-3-41:2011 applies to non-sheathed single-core cables insulated with halogen-free crosslinked compound and intended to give low smoke and low corrosive gas release in fire conditions. The cable family is rated up to and including 450/750 V (U0/U), is intended for fixed wiring applications, and has a maximum conductor operating temperature of 90 °C.
The document is organized into four clauses, two normative annexes and a bibliography.
| Annex | What it covers |
|---|---|
| Annex A | Tests for cables to EN 50525-3-41, with applicability by cable type |
| Annex B | General data, including dimensions and minimum insulation resistance |
Clause 4 divides the cable family into fixed-wiring and internal-wiring versions:
- H07Z-U and H07Z-R for fixed wiring
- H07Z-K for fixed wiring
- H05Z-U and H05Z-K for internal wiring
What are the key requirements of SIST EN 50525-3-41:2011?
SIST EN 50525-3-41:2011 sets out the conductor class, insulation type, cable designation, dimensions and fire-performance checks for each cable variant. In practice, this tells the user what construction to specify and which tests to use to confirm the cable meets the part.
Cable construction and designation
Clause 4 requires each version to use the conductor class linked to its CENELEC code in EN 60228. H07Z-U and H05Z-U use class 1 conductors, H07Z-R uses class 2 conductors, and H07Z-K and H05Z-K use class 5 conductors. For the reader, this means the cable designation itself tells you whether you are selecting a rigid or flexible conductor construction.
Clause 4 also requires polyolefin cross-linked insulation of Type EI 5 to EN 50363-5. That matters because the insulation material is part of the fire and temperature performance, not just the cable size.
Size ranges and marking
Clause 4 gives separate size ranges for each cable family and links the cable dimensions to Tables B.1 to B.4. It also requires the CENELEC code marking to comply with Clause 6 of EN 50525-1. In practice, this is what a purchaser, inspector or installer checks on the cable sheath marking and in the datasheet.
Electrical, dimensional and fire-related performance
Clause 4 requires each cable to comply with EN 50525-1 plus the particular requirements of this part. Annex A then ties those requirements to the test programme: conductor resistance, voltage tests, insulation resistance at 90 °C, insulation fault checks, constructional inspection, thickness and diameter measurements, insulation material tests, low-temperature impact, flame propagation, smoke emission, and halogen assessment.
For fire performance, the document requires compliance with EN 60332-1-2 for vertical flame propagation and EN 61034-2 for smoke density. For the reader, that means the cable family is intended where reduced smoke and fire spread are important, and the test evidence must support that claim.
Smoke performance
Clause 4 requires all sizes to exceed 60 % light transmittance during the EN 61034-2 test. That is the practical acceptance point for low smoke emission and is often the key result needed in specification review or compliance testing.
What terms does SIST EN 50525-3-41:2011 define?
- H07Z-U - CENELEC code for a fixed-wiring cable with a class 1 conductor.
- H07Z-R - CENELEC code for a fixed-wiring cable with a class 2 conductor.
- H07Z-K - CENELEC code for a fixed-wiring cable with a class 5 conductor.
- H05Z-U - CENELEC code for an internal-wiring cable with a class 1 conductor.
- H05Z-K - CENELEC code for an internal-wiring cable with a class 5 conductor.
- Class 1, class 2 and class 5 conductors - conductor constructions defined in EN 60228 and used here to separate rigid and flexible versions.
- Type EI 5 - the halogen-free crosslinked polyolefin insulation material specified in EN 50363-5.
- U0/U - the rated voltage designation used for this cable family, up to and including 450/750 V.
Who uses SIST EN 50525-3-41:2011?
Cable manufacturers use SIST EN 50525-3-41:2011 to design the cable construction, choose the conductor class, select the insulation material and apply the correct code marking. Test laboratories and certification bodies use it to run the required electrical, dimensional, flame, smoke and halogen-related tests.
Engineers, quality managers and buyers use it when specifying cables for fixed wiring, internal wiring, switchgear and control gear, especially where low smoke and halogen-free performance are required. Installers and panel builders use it to confirm they are fitting the right H07Z or H05Z variant for the application and voltage level.
What changed in SIST EN 50525-3-41:2011 from the previous edition?
SIST EN 50525-3-41:2011 supersedes HD 22.9 S3:2007.
Which standards are used with SIST EN 50525-3-41:2011?
| Standard | What it contributes |
|---|---|
| EN 50525-1 | General requirements, marking rules, terms and the halogen assessment reference |
| EN 50363-5 | Halogen-free crosslinked insulating compounds, including Type EI 5 |
| EN 50395 | Electrical test methods used in Annex A |
| EN 50396 | Non-electrical test methods, including thickness and diameter measurements |
| EN 60228 | Conductor classes for rigid and flexible conductors |
| EN 60332-1-2 | Vertical flame propagation test under fire conditions |
| EN 60811-1-4 | Low-temperature impact test for insulation materials |
| EN 61034-2 | Smoke density measurement for cables burning under defined conditions |
| EN 60719 | Calculation of lower and upper limits for average outer dimensions |
| HD 516 | Guidance on the safe use of these cables |
What does the SIST EN 50525-3-41:2011 document contain?
Annex A provides the test matrix for each cable variant, so users can see which tests apply to H07Z-U, H07Z-R, H07Z-K, H05Z-U and H05Z-K. Annex B provides general data tables for rigid and flexible conductors, including insulation thickness, mean overall diameter and minimum insulation resistance at 90 °C.
The main clause 4 is structured by use case, first fixed wiring and then internal wiring, which makes it easy to match a cable code to a job. The bibliography points readers to EN 60719 for dimension calculations and HD 516 for guidance on safe use.
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 06-Jan-2009
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
SIST EN 50525-3-41:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke". This standard covers: EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
SIST EN 50525-3-41:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50525-3-41:2011 has the following relationships with other standards: It is inter standard links to SIST HD 22.9 S3:2007, SIST EN 1648-1:2018, SIST EN 1648-2:2018, SIST EN 60335-1:2012/A13:2017, SIST HD 22.9 S3:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 50525-3-41:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 50525-3-41:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR988GHO.DEOLVSRVHEQLPLRJQMHYDUQLPLODVWQRVWPL
(QRåLOQLQHRSODãþHQLNDEOL]]DPUHåHQRL]RODFLMREUH]KDORJHQRYLQ]QL]NRHPLVLMR
GLPD
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed
cables with halogen-free crosslinked insulation, and low emission of smoke
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 3-41: Leitungen mit verbessertem Verhalten im Brandfall - Halogenfreie, raucharme
Ader- und Verdrahtungsleitungen mit vernetzter Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 3-41: Câbles à performances spéciales au feu - Conducteurs
isolés en matériau élastomère réticulé sans halogène, à faible dégagement de fumée
Ta slovenski standard je istoveten z: EN 50525-3-41:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50525-3-41
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 22.9 S3:2007
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 3-41: Cables with special fire performance -
Single core non-sheathed cables with halogen-free crosslinked insulation,
and low emission of smoke
Câbles électriques - Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) - Teil 3-41: Starkstromleitungen mit
Partie 3-41: Câbles à performances verbessertem Verhalten im Brandfall -
spéciales au feu - Halogenfreie, raucharme Ader- und
Conducteurs isolés en matériau Verdrahtungsleitungen mit vernetzter
élastomère réticulé sans halogène, à Isolierung
faible dégagement de fumée
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-3-41:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric
cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-3-41 on 2011-01-17.
This document, which is one of a multipart series, supersedes HD 22.9 S3:2007.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17
____________
- 3 - EN 50525-3-41:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Heat resistant cables (90 °C) . 5
4.1 Cables for fixed wiring – H07Z-U and H07Z-R . 5
4.2 Cables for fixed wiring – H07Z-K . 5
4.3 Cables for internal wiring – H05Z-U . 6
4.4 Cables for internal wiring – H05Z-K . 7
Annex A (normative) Tests for cables to EN 50525-3-41 . 8
Annex B (normative) General data . 9
Bibliography . 11
Tables
Table A.1 . 8
Table B.1 − Cables with rigid conductor (450/750 V) . 9
Table B.2 − Cables with flexible conductor (450/750 V) . 10
Table B.3 − Cables with rigid conductor (300/500 V) . 10
Table B.4 − Cables with flexible conductor (300/500 V) . 10
1 Scope
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free
crosslinked compound and having low emission of smoke and corrosive gases when exposed
to fire.
NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as
part of the check for absence of halogens (see Annex B of EN 50525-1).
The cables are of rated voltages U /U up to and including 450/750 V.
NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with
mechanical protection, within switchgear and control gear - see HD 516.
The cables are intended for fixed wiring applications.
The maximum conductor operating temperature for each of the cables in this standard is
90 °C.
NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general
requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
NOTE One or more references to the standards below are in respect of a specific sub-division of that standard,
for instance a clause, a table, a class or a type. Cross-references to these standards are undated and, at all times,
the latest version applies.
EN 50363-5 Insulating, sheathing and covering materials for low voltage
energy cables - Part 5: Halogen-free, cross-linked insulating
compounds
EN 50395 Electrical test methods for low voltage energy cables
EN 50396 Non electrical test methods for low voltage energy cables
EN 50525-1 Electric cables - Low voltage energy cables of rated voltages up
to and including 450/750 V (U /U) - Part 1: General requirements
EN 60228 Conductors of insulated cables (IEC 60228)
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions -
Part 1-2: Test for vertical flame propagation for a single insulated
wire or cable - Procedure for 1 kW pre-mixed flame
(IEC 60332-1-2)
EN 60811-1-4 Insulating and sheathing materials of electric and optical cables -
Common test methods - Part 1-4: General application - Test
...