Compressed air — Energy efficiency — Assessment

ISO 11011:2013 sets requirements for conducting and reporting the results of a compressed air system assessment that considers the entire system, from energy inputs to the work performed as the result of these inputs. ISO 11011:2013 considers compressed air systems as three functional subsystems: supply which includes the conversion of primary energy resource to compressed air energy; transmission which includes movement of compressed air energy from where it is generated to where it is used; demand which includes the total of all compressed air consumers, including productive end-use applications and various forms of compressed air waste. ISO 11011:2013 sets requirements for analysing the data from the assessment, reporting and documentation of assessment findings, and identification of an estimate of energy saving resulting from the assessment process. ISO 11011:2013 identifies the roles and responsibilities of those involved in the assessment activity.

Air comprimé — Efficacité énergétique — Évaluation

L'ISO 11011:2013 fixe les exigences pour obtenir et rapporter les résultats de l'évaluation d'un système d'air comprimé (appelée ci-après «évaluation») tenant compte de tout le système, des entrées d'énergie jusqu'au travail effectué en conséquence de ces entrées. L'ISO 11011:2013 considère que les systèmes d'air comprimé sont constitués de trois sous-systèmes fonctionnels: une alimentation (offre) incluant la conversion de la ressource d'énergie primaire en énergie d'air comprimé; une transmission incluant le mouvement de l'énergie de l'air comprimé de son lieu de production jusqu'à son lieu d'utilisation; une demande incluant tous les utilisateurs d'air comprimé, y compris les applications d'utilisation finale de production et les diverses formes de consommations perdues d'air comprimé. L'ISO 11011:2013 fixe des exigences concernant l'analyse des données issues de l'évaluation, le rapport et la documentation des résultats de l'évaluation, et l'identification d'une estimation d'économie d'énergie résultant du processus d'évaluation. L'ISO 11011:2013 identifie les rôles et les responsabilités des personnes impliquées dans l'activité d'évaluation.

General Information

Status
Published
Publication Date
22-Aug-2013
Current Stage
9020 - International Standard under periodical review
Start Date
15-Oct-2025
Completion Date
15-Oct-2025
Ref Project
Standard
ISO 11011:2013 - Compressed air -- Energy efficiency -- Assessment
English language
51 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11011:2013 - Air comprimé -- Efficacité énergétique -- Évaluation
French language
55 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 11011
First edition
2013-09-15
Compressed air — Energy
efficiency — Assessment
Air comprimé — Efficacité énergétique — Évaluation
Reference number
©
ISO 2013
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved

Contents  Page
Foreword .v
Introduction .vi
1  Scope . 1
2  Normative references . 1
3  Terms and definitions . 1
3.1 General . 2
3.2 Flow . 3
3.3 Pressure . 4
3.4 Storage . 5
3.5 Volume . 5
4  Roles and responsibilities . 6
4.1 Identification of assessment team members . 6
4.2 Site management support . 7
4.3 Communications . 7
4.4 Access to equipment, resources, and information . 7
4.5 Assessment objectives and scope . 7
4.6 Identification of other assessment team members . 7
4.7 Objective check . 7
5  Assessment methodology. 8
5.1 General . 8
5.2 Systems engineering methods . 8
5.3 Systems engineering process . 8
5.4 System assessment process . 9
6  Parameters and their determination .10
6.1 General .10
6.2 Measurement .10
6.3 Pressure .10
6.4 Flow rate .11
6.5 Power .12
7  Initial data collection and evaluation .13
7.1 General .13
7.2 Plant background .13
7.3 Plant function .13
7.4 Compressed air system definition .13
7.5 Inventory of key end-use air demands .13
7.6 Heat recovery .13
7.7 Baseline period and duration of data logging .14
7.8 Energy use .14
7.9 Compressed air system supply efficiency .14
7.10 System volume .14
7.11 Pressure .15
7.12 Flowrate .15
7.13 Critical air demands .15
7.14 Compressed air waste .15
7.15 Air treatment .15
7.16 Compressor control .16
7.17 Storage .16
7.18 Maintenance .16
7.19 Ambient intake conditions .16
8  Analysis of data from assessment .16
8.1 General .16
8.2 Baseline profiles .17
8.3 System volume .19
8.4 Pressure profile .19
8.5 Perceived high-pressure demand .21
8.6 Demand profile .22
8.7 Critical air demands .23
8.8 Compressed air waste .24
8.9 Optimized air treatment .25
8.10 Reduced system operating pressure .26
8.11 Balance of supply and demand .27
8.12 Maintenance opportunities .27
8.13 Heat recovery opportunities .28
9  Reporting and documentation of assessment findings .28
9.1 Assessment report .28
9.2 Confidentiality .29
9.3 Energy-saving opportunities .29
9.4 Data for third-party review .29
Annex A (informative) Introduction to energy assessment .30
Annex B (informative) Assessment activities — General .32
Annex C (informative) Assessment activities — Supply .
...


NORME ISO
INTERNATIONALE 11011
Première édition
2013-09-15
Air comprimé — Efficacité
énergétique — Évaluation
Compressed air — Energy efficiency — Assessment
Numéro de référence
©
ISO 2013
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2013
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2013 – Tous droits réservés

Sommaire Page
Avant-propos .v
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
3.1 Généralités . 2
3.2 Flux . 3
3.3 Pression . 4
3.4 Stockage . 5
3.5 Volume . 6
4 Rôles et responsabilités . 6
4.1 Identification des membres de l’équipe d’évaluation . 6
4.2 Soutien de la direction du site . 7
4.3 Communications . 7
4.4 Accès aux matériels, aux ressources et aux informations. 7
4.5 Objectifs et domaine d’application de l’évaluation . 7
4.6 Identification d’autres membres de l’équipe d’évaluation . 8
4.7 Contrôle de l’objectif . 8
5 Méthodologie de l’évaluation . 8
5.1 Généralités . 8
5.2 Méthodes d’ingénierie des systèmes . 8
5.3 Processus d’ingénierie des systèmes . 9
5.4 Processus d’évaluation d’un système . 9
6 Paramètres et leur détermination .10
6.1 Généralités .10
6.2 Mesurage .10
6.3 Pression .11
6.4 Débit .12
6.5 Puissance .12
7 Collecte et évaluation initiales des données .13
7.1 Généralités .13
7.2 Contexte de l’installation .14
7.3 Fonction de l’installation .14
7.4 Définition du système d’air comprimé .14
7.5 Inventaire des demandes essentielles d’air de l’utilisation finale .14
7.6 Récupération de chaleur .14
7.7 Période de référence et durée de la journalisation des données.14
7.8 Utilisation énergétique .15
7.9 Efficacité de l’alimentation du système d’air comprimé .15
7.10 Volume du système .15
7.11 Pression .15
7.12 Débit .16
7.13 Demandes d’air critiques .16
7.14 Identification des consommations perdues d’air comprimé .16
7.15 Traitement d’air .16
7.16 Commande du compresseur .17
7.17 Stockage .17
7.18 Maintenance .17
7.19 Conditions d’admission ambiantes .17
8 Analyse des données issues de l’évaluation .17
8.1 Généralités .17
8.2 Profils de base de référence .18
8.3 Volume du système .20
8.4 Profil de pression .20
8.5 Demande de haute pression perçue .22
8.6 Profil de demande .24
8.7 Demandes d’air critiques .25
8.8 Consommations perdues d’air comprimé .26
8.9 Optimiser le traitement d’air .27
8.10 Diminuer la pression de service du système.28
8.11 Équilibrer l’offre et la demande .28
8.12 Évaluer les opportunités liées à la maintenance .29
8.13 Évaluer les perspectives de récupération de chaleur .30
9 Rapport et documentation des résultats de l’évaluation .30
9.1 Rapport d’évaluation .30
9.2 Confidentialité .31
9.3 Perspectives d’économie d’énergie .31
9.4 Données destinées à la revue d’une tierce partie .31
Annexe A (informative) Introduction à l’évaluation énergétique .32
Annexe B (informative) Activités d’évaluation — Généralités .35
Annexe C (informative) Activités d’évaluation — Alimentation .40
Annexe D (informative) Activités d’évaluation — Transmission .46
Annexe E (informative) Activités d’évaluation — Demande .51
Annexe F (informative) Compétences .54
Bibliographie .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.