Abstract

This document specifies a spectrophotometric method for the determination of the hydroxypropyl group content of modified starches.

Status
Published
Publication Date
16-Aug-2026
Current Stage
6060 - International Standard published - 60 Publication
Start Date
17-Aug-2026
Due Date
19-Jun-2027
Completion Date
19-Jun-2027

Buy Documents

Standard

ISO 25136:2026 - Modified starch — Determination of hydroxypropyl content — Spectrophotometric method

Release Date:17-Aug-2026
English language (8 pages)
sale 15% off
Preview
sale 15% off
Preview

ISO 25136:2026 is an International Standard published by ISO. It specifies a spectrophotometric method for determining the hydroxypropyl group content of modified starches, so it is used when a lab needs a measured value for that substitution level in a starch sample.

What does ISO 25136:2026 specify?

ISO 25136:2026 specifies the analysis method, the reagents and apparatus, the sample preparation steps, the calculation on a dry-mass basis, and the test report items. It is a laboratory method for modified starch, and the sampling note points users to separate sampling guidance rather than building sampling into the method itself.

AnnexWhat it covers
Annex APrecision of the method, based on an interlaboratory collaborative trial

The document is organized into clauses on scope, normative references, terms and definitions, principle, reagents, apparatus, sampling, preparation of the test sample, procedure, calculation and expression of results, precision, and test report.

What are the key requirements of ISO 25136:2026?

Sample preparation and test portion

  • Clause 7 expects the laboratory sample to be representative and not altered during transport or storage. In practice, the result is only meaningful if the submitted sample reflects the lot being judged.
  • Clause 8 requires the sample to be sieved through 800 µm, ground with a blade mill if needed, and homogenized. This matters because particle size and mixing affect how completely the starch dissolves and reacts.
  • Clause 9.2 calls for a test portion of about 0.05 g to 0.10 g weighed to 0.000 1 g. That gives a controlled mass for the color reaction and for the final content calculation.

Measurement principle and calibration

  • Clause 4 uses concentrated sulfuric acid and ninhydrin to convert the hydroxypropyl-derived reaction products into a purple complex measured at 590 nm. In practice, the analyst is measuring absorbance, not the starch directly.
  • Clause 9.1 requires a calibration graph prepared from 1,2-propanediol standard working solutions. The calibration links absorbance to the amount of response expected from the sample.
  • Clause 9.4 repeats the same reaction sequence for the test solution and reads the absorbance against the starch blank. This is how background color or reagent effects are corrected.

Reagents, apparatus, and calculation

  • Clause 5 and Clause 6 require analytical-grade reagents, water conforming to ISO 3696 grade 3 or better, pipettes and volumetric flasks in accordance with ISO 648, and a spectrophotometer with 1 cm cells. That means the method depends on accurate volume handling and stable optical measurement.
  • Clause 9.6 requires moisture content to be determined in accordance with ISO 1666. The final result is reported on a dry sample basis, so moisture correction is part of the result, not an optional extra.
  • Clause 10 uses the calibration result, dilution volume, test portion mass, moisture content, and a conversion factor of 0.776 3 to calculate hydroxypropyl content. The result is rounded to 0.01 % (m/m), and the final value is the arithmetic mean of three determinations if repeatability is satisfied.

Precision and reporting

  • Clause 11 gives repeatability and reproducibility criteria and points to Annex A for the collaborative trial behind them. For users, this sets an expectation for how close duplicate results should be within one laboratory and between laboratories.
  • Clause 12 requires the report to identify the sample, state the method as ISO 25136:2026, include any optional operating details or incidents, give the result or three results if repeatability was checked, include recovery, and record the date. That supports traceability in quality control, disputes, and supplier-customer checks.

What terms does ISO 25136:2026 define?

  • Hydroxypropyl content - the mass of hydroxypropyl groups divided by the mass of the test portion of hydroxypropylated starch, expressed as a fraction or percentage.
  • Test portion - the weighed amount of sample taken for the analysis.
  • Calibration graph - the graph used to convert measured absorbance into the corresponding 1,2-propanediol response.
  • Blank test - the parallel run used as the reference for the absorbance measurement.
  • Repeatability - the closeness of results obtained in the same laboratory under the same conditions.
  • Reproducibility - the closeness of results obtained in different laboratories under different conditions.

Who uses ISO 25136:2026?

ISO 25136:2026 is used by laboratories that test modified starch, especially quality control and customer laboratories that need a quantitative hydroxypropyl content result. It is also relevant to starch manufacturers, ingredient suppliers, and buyers who check product specification or compare lots using the same measurement basis.

Which standards are used with ISO 25136:2026?

ISO 25136:2026 cites ISO 3696 for analytical-laboratory water, ISO 648 for pipettes and volumetric flasks, and ISO 1666 for moisture content determination. The bibliography also cites ISO 5725-1 and ISO 5725-2 for accuracy, repeatability, and reproducibility concepts, and CAC/GL 50-2004 for sampling guidance.

What does the ISO 25136:2026 document contain?

ISO 25136:2026 contains the full laboratory procedure: reagent preparation, apparatus requirements, sample preparation, calibration graph preparation, the color-forming reaction, absorbance measurement at 590 nm, and the calculation to dry-basis hydroxypropyl content. It also includes the precision summary from an interlaboratory trial in Annex A, together with the reporting requirements needed for traceable results.

Buy Documents

Standard

ISO 25136:2026 - Modified starch — Determination of hydroxypropyl content — Spectrophotometric method

Release Date:17-Aug-2026
English language (8 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

Bureau Veritas

Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

COFRAC France Verified

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

ISO 25136:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Modified starch — Determination of hydroxypropyl content — Spectrophotometric method". This standard covers: This document specifies a spectrophotometric method for the determination of the hydroxypropyl group content of modified starches.

This document specifies a spectrophotometric method for the determination of the hydroxypropyl group content of modified starches.

ISO 25136:2026 is classified under the following ICS (International Classification for Standards) categories: 67.180.20 - Starch and derived products. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 25136:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 hydroxypropyl content
  • 4 Principle
  • 4.1 Spectrophotometric method for hydroxypropyl content
  • 5 Reagents
  • 6 Apparatus
  • 7 Sampling
  • 8 Preparation of test sample
  • 9 Procedure
  • 9.1 Preparation of the calibration graph
  • 9.2 Test portion
  • 9.3 Preparation of the test solution
  • 9.4 Determination
  • 9.5 Blank test
  • 9.6 Moisture content
  • 9.7 Number of determinations
  • 10 Calculation and expression of results
  • 11 Precision
  • 11.1 Interlaboratory test
  • 11.2 Repeatability
  • 11.3 Reproducibility
  • 11.4 Repeatability and Reproducibility
  • 12 Test report
  • Annex A
  • Bibliography

1 Scope

This document specifies a spectrophotometric method for the determination of the hydroxypropyl group content of modified starches.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 648, Laboratory glassware — Single-volume pipettes ISO 1666, Starch — Determination of moisture content — Oven-drying method

3 Terms and definitions

The following terms and definitions apply to this document.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at http:// www .electropedia .org/

3.1 hydroxypropyl content

mass of hydroxypropyl groups divided by the mass of the test portion of hydroxypropylated starch, which represents the proportion or concentration of hydroxypropyl groups within the starch sample Note 1 to entry: It is expressed as a fraction or percentage of the total mass of the sample.

4 Principle

4.1 Spectrophotometric method for hydroxypropyl content

In concentrated sulfuric acid, the hydroxypropyl group in modified starches is oxidized to produce propylene glycol, which is subsequently dehydrated to yield propionaldehyde and propenol. In this acidic medium, propionaldehyde and propenol react with ninhydrin to form purple-colored complex. The hydroxypropyl content is quantified by measuring the absorbance of this complex at 590 nm.

5 Reagents

Use only reagents of recognized analytical grade, unless otherwise specified. 5.1 Water, conforming to at least grade 3 of ISO 3696, and free from carbon dioxide.

ISO 25136:2026(en) 5.2 Sulfuric acid, concentrated, ρ(20) ≥ 1,84 g/ml, minimum 98 % purity. The sulfuric acid shall be well sealed.

5.3 Sodium bisulfite solution, 50 g/l.

Weigh, to the nearest 0,1 g, approximately 50 g of sodium bisulfite, and dissolve it in water (5.1) in a 1 000 ml sealed ampoule.

5.4 Ninhydrin solution, 30 g/l.

Dissolve 30 g of ninhydrin with sodium bisulfite solution (5.3) in a 1 000 ml sealed ampoule. Prepare freshly and use promptly.

5.5 Sulfuric acid solution, 1 mol/l.

Dilute 30 ml of concentrated sulfuric acid (5.2) to 1 000 ml with water (5.1). 1) 5.6 1,2-propanediol (CAS No. 57-55-6) , at least 99,7 % purity. 5.7 Stock solution, c = 1 mg/ml.

Weigh, to the nearest 0,000 1 g, 1,000 0 g of 1,2-propanediol (5.6), and transfer into a 1 000 ml one-mark volumetric flask. Dilute to the mark with water (5.1) and mix thoroughly. 5.8 Standard working solutions, corresponding to 10 μg/ml, 20 μg/ml, 30 μg/ml, 40 μg/ml, and 50 μg/ ml.

  • Pipette 1 ml, 2 ml, 3 ml, 4 ml, and 5 ml of the stock solution (5.7) into five separate 100 ml one-mark volumetric flasks.
  • Dilute each to the mark with distilled water (5.1) and mix thoroughly.
  • The resulting standard solutions contain 10 μg/ml, 20 μg/ml, 30 μg/ml, 40 μg/ml, and 50 μg/ml of 1,2-propanediol, respectively.

6 Apparatus

Usual laboratory apparatus, and in particular, the following.

6.1 Analytical balance, capable of weighing to the nearest 0,000 1 g. 6.2 Pipettes, with capacities of 1 ml, 2 ml, and 5 ml, in accordance with the requirements of ISO 648. 6.3 One-mark volumetric flask of capacity 100 ml, 1 000 ml, in accordance with the requirements of ISO 648.

6.4 Test tube with stopper, with a capacity of 25 ml and graduation marks. 6.5 Spectrophotometer, fitted with cells of optical path length 1 cm, capable of measuring at a wavelength from 390 nm to 780 nm.

6.6 Water bath.

1) CAS Registry Number® is a trademark of CAS corporation. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.

ISO 25136:2026(en) 6.7 Test sieve, with a mesh size of 800 μm.

6.8 Blade mill.

...