Shaped insulating refractory products — Determination of the permanent change in dimensions on heating

Produits réfractaires isolants façonnés — Détermination de la variation permanente de dimensions sous l'action de la chaleur

General Information

Status
Withdrawn
Publication Date
31-Aug-1973
Withdrawal Date
31-Aug-1973
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Nov-1987
Ref Project

Relations

Buy Standard

Standard
ISO 2477:1973 - Shaped insulating refractory products -- Determination of the permanent change in dimensions on heating
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2477:1973 - Shaped insulating refractory products — Determination of the permanent change in dimensions on heating Released:9/1/1973
French language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD 2477
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION MEXjXYHAFWlHAn OPïAHWAUHR II0 DAWPTWALlHM .ORGANISATION INTERNATIONALE DE NORMALISATION
Shaped insulating refractory products - Determination of the
permanent change in dimensions on heating
First edition - 1973-09-01
UDC 666.76 : 531.7 : 620.179.13 Ref. No. IS0 2477-1973 (E)
m
h
Descriptors : refractory products, high temperature tests, dimensional stability, dimensionai measurement.
h
ic
R
Price based on 3 pages
w

---------------------- Page: 1 ----------------------
FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
IS0 2477 was drawn up by Technical Committee
International Standard
ISO/TC 33, Refractories, and circulated to the Member Bodies in November 1971.
It has been approved by the Member Bodies of the following countries :
India
Austria Spain
Nether lands Sweden
Czechoslovakia
Egypt, Arab Rep. of New Zealand Switzerland
France Port uga I United Kingdom
Hungary South Africa, Rep. of U.S.S.R.
No Member Body expressed disapproval of the document.
~ O International Organization for Standardization, 1973
,
I
~ Printed in Switzerland

---------------------- Page: 2 ----------------------
IS0 2477-1973 (E)
INTE RNATl ON AL STAN DARD
Shaped insulating refractory products - Determination of the
permanent change in dimensions on heating
1 SCOPE AND FIELD OF APPLICATION The furnace shall be capable of heating the test piece to,
and maintaining it at, the testing temperature specified in
This International Standard specifies a method for
section 7.
determining the permanent change in dimensions of shaped
insulating refractory products on heating to a
predetermined temperature which is maintained for a
5.2 Thermocouples
specified period of time.
ei
5.3 Length measuring devices
2 REFERENCE
Slide calipers or another instrument of measurement having
ISO/R 475, Sizes of rectangular refractory bricks.
an accuracy better than 2 0,2 mm may be used.
3 DEFINITION
permanent change in dimensions : The expansion or 6 TEST PIECES
contraction remaining after cooling to ambient temperature
Five test pieces shall be cut, each from a different brick,
of a refractory product heated for a fixed time at a given
and have the following dimensions :
temperature.
It is usually expressed as the change, AL, in one dimension 1 O0 mm x 1 14 mm x 64 mm .
of the sample, calculated as a percentage of the original
dimension, L (i.e. 100 ALIL). The 100 mm dimension shall be in the direction of the
length of the brick; the other two dimensions represent the
width and thickness of a normal rectangular brick as given
in ISO/R 475.
4 PRINCIPLE
In cases where the width and/or thickness of the brick are
Cutting of test pieces, in the form of rectangular prisms,
less than 114 mm and 64 mm, these dimensions can can be
from the sample and measurement of the linear dimensions
L
reduced by agreement between the interested parties.
of these test pieces.
Heating the test pieces at a prescribed rate in a furnace
having an oxidizing atmosphere, to a predetermined
temperature, and maintaining this temperature for a
specified period of time.
7 PROCEDURE
Allowing the test pieces to cool to ambient temperature
then measuring the linear dimensions and calculating the
7.1 Measurement of test pieces
changes which have taken place.
The linear change in dimension shall be de
...

NORME INTERNATIONALE @ 2477
‘ax&
~
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION *MEEnYHAPOLlHA5i OPiAHHJAUiIR no CTAHLIAPTHJAUHH .ORGANISATION INTERNATIONALE DE NORMALISATION
Produits réfractaires isolants faconnés - Détermination de la
bt
variation permanente de dimensions sous l‘action de la
chaleur
Première édition - 1973-09-01
I
U
- CDU 666.76 : 531.7 : 620.179.13 Réf. No : IS0 2477-1973 (F)
m
I-
C
Descripteun : produit réfractaire, essai a haute température, stabilité dimensionnelle, mesurage de dimension.
I-
I-
d
N
O
Prix basé sur 3 pages
2

---------------------- Page: 1 ----------------------
AVANT-PROPOS
IS0 (Organisation Internationale de Normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (Comités Membres ISO). L'élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
a le droit de faire partie du Comité Technique
Membre intéressé par une étude
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en I iaison avec I'ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I'ISO.
La Norme Internationale IS0 2477 a été établie par le Comité Technique
ISO/TC 33, Matériaux réfractaires, et soumise aux Comités Membres en
novembre 1971.
Elle a été approuvée par les Comités Membres des pays suivants
Afrique du Sud, Rép. d' Hongrie Royaume-Uni
Allemagne Inde Suède
Autriche Nouvel le-Zélande Suisse
Egypte, Rép. arabe d' Pays-Bas Tchécoslovaquie
Espagne Portugal Turquie
France Roumanie U.R.S.S.
Aucun Comité Membre n'a désapprouvé le document.
0 Organisation internationale de Normalisation. 1973
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE IS0 2477-1973 (F)
Produits réfractaires isolants faconnes - Détermination de la
variation permanente de dimensions sous l'action de la
chaleur
Le four doit permettre l'élévation et le maintien de la
1 OBJET ET DOMAINE D'APPLICATION
température de l'éprouvette à la temperature d'essai dans
La présente Norme Internationale spécifie une méthode de
les conditions spécifiées au chapitre 7.
détermination de la variation permanente de dimensions des
produits réfractaires isolants façonnés, après traitement
thermique à une température spécifiée maintenue pendant 5.2 Thermocouples
une durée déterminée.
5.3 Appareil de mesurage des dimensions
2 RÉFÉRENCE
Un pied à coulisse ou autre appareil de mesurage, de
ISO/R 475, Dimensions des briques réfractaires a faces
précision supérieure à _+ 0,2 mm, peut être utilisé.
rectangulaires.
3 DÉFINITION
6 ÉPROUVETTES
variation permanente des dimensions : Dilatation ou
Cinq éprouvettes doivent être découpées, chacune sur une
rétraction, subsistant après refroidissement à la température
brique différente; elles doivent avoir les dimensions
ambiante, d'un produit réfractaire chauffé pendant un
suivantes :
certain temps à unc température donnée.
Elle est généralement exprimée par le rapport de la
100 mm x 114 mm x 64 mm.
variation AL d'une dimension de l'échantillon à la valeur
initiale L de cette dimension, sous la forme d'un
La dimension de 100 mm doit être prise dans le sens de la
pourcentage (c'est-à-dire, 1 O0 ALlL).
longueur de la brique; les deux autres dimensions
correspondent à la largeur et à l'épaisseur d'une brique
normale définie dans I'ISO/R 475.
4 PRINCIPE
Si la largeur et/ou l'épaisseur de la brique sont inférieures à
Découpage, dans l'échantillon pour essai, d'éprouvettes en
114 mm et 64 mm, ces dimensions de l'éprouvette peuvent
forme de prismes rectangulaires et mesurage de leurs
être réduites par accord entre les parties intéressées.
dimensions linéaires.
Chauffage des éprouvettes dans un four à atmosphère
oxydante, suivant un régime prescrit, jusqu'à une
température déterminée qui est maintenue pendant une
7 MODE OPÉRATOIRE
durée spécifiée.
Après refroidissement des éprouvettes à la température
7.1 Mesurage des éprouvettes
ambiante, nouveau mesurage des dimensions linéaires et
calcul de la variation permanente de dimensions.
La variation permanente de dimensions doit être
déterminée sur la lo
...