Dentistry - Pre-capsulated dental amalgam

ISO 20749:2017 specifies the requirements and test methods for dental amalgam products supplied to the user in capsules, pre-dosed with dental amalgam alloy and dental mercury in quantities suitable for the creation of a single dental restoration. ISO 20749:2017 specifies the requirements and test methods for dental amalgam alloys that are suitable for the preparation of dental amalgam and the capsule, together with the requirements and test methods for that dental amalgam and the requirements for packaging and marking. ISO 20749:2017 is not applicable to dental amalgam alloys supplied as a free-flowing powder in bulk quantities or as powder compressed into tablets, or to dental mercury supplied in sachets or bulk quantities. This document is not applicable to other metallic materials in which an alloy powder reacts with an alloy that is liquid at ambient temperature to produce a solid metallic material intended for dental restoration. Specific qualitative and quantitative test methods for demonstrating freedom from unacceptable biological hazard are not included in this document. For the assessment of possible biological hazards, reference can be made to ISO 10993‑1 and ISO 7405. The scope of this document is restricted to dental amalgam products marketed in pre-capsulated form alone. Other products intended for use in the production of dental amalgam restorations (dental amalgam alloy as a free-flowing powder supplied in bulk masses, dental amalgam alloy powder supplied as compressed tablets and dental mercury sachets) are within the scope of ISO 24234.

Médecine bucco-dentaire — Amalgame dentaire en capsules prédosées

L'ISO 20749:2017 spécifie les exigences et les méthodes d'essai applicables aux amalgames dentaires fournis à l'utilisateur sous forme de capsules, prédosées avec l'alliage pour amalgame dentaire et le mercure à usage dentaire dans des quantités appropriées pour créer une seule restauration dentaire. L'ISO 20749:2017 spécifie les exigences et les méthodes d'essai applicables aux alliages pour amalgame dentaire utilisés dans la préparation des amalgames dentaires et des capsules, les exigences et les méthodes d'essai relatives à ces amalgames dentaires et les exigences d'emballage et de marquage. L'ISO 20749:2017 n'est applicable ni aux alliages pour amalgame dentaire fournis sous forme de poudre fluide en vrac ou de poudre sous forme de comprimés ni au mercure à usage dentaire fourni sous forme de sachets ou en vrac. L'ISO 20749:2017 n'est pas applicable à d'autres matériaux métalliques dans lesquels une poudre d'alliage réagit avec un alliage liquide à température ambiante pour produire un matériau métallique solide destiné à la restauration dentaire. L'ISO 20749:2017 ne comporte aucune méthode d'essai qualitative et quantitative spécifique démontrant l'absence de dangers biologiques inacceptables. Pour évaluer la possibilité de tels dangers, il est possible de se référer à l'ISO 10993‑1 et à l'ISO 7405. Le domaine d'application de l'ISO 20749:2017 est limité aux amalgames dentaires commercialisés sous forme de capsules prédosées uniquement. Les autres produits destinés à être utilisés pour la production de restaurations en amalgame dentaire (alliage d'amalgame dentaire sous forme de poudre fluide en vrac, poudre d'alliage pour amalgame dentaire sous forme de comprimés et sachets de mercure à usage dentaire) font partie du domaine d'application de l'ISO 24234.

General Information

Status
Withdrawn
Publication Date
16-Mar-2017
Current Stage
9599 - Withdrawal of International Standard
Start Date
30-Jun-2023
Completion Date
13-Dec-2025
Ref Project

Relations

Standard
ISO 20749:2017 - Dentistry -- Pre-capsulated dental amalgam
English language
28 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 20749:2017 - Médecine bucco-dentaire -- Amalgame dentaire en capsules prédosées
French language
30 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 20749:2017 is a standard published by the International Organization for Standardization (ISO). Its full title is "Dentistry - Pre-capsulated dental amalgam". This standard covers: ISO 20749:2017 specifies the requirements and test methods for dental amalgam products supplied to the user in capsules, pre-dosed with dental amalgam alloy and dental mercury in quantities suitable for the creation of a single dental restoration. ISO 20749:2017 specifies the requirements and test methods for dental amalgam alloys that are suitable for the preparation of dental amalgam and the capsule, together with the requirements and test methods for that dental amalgam and the requirements for packaging and marking. ISO 20749:2017 is not applicable to dental amalgam alloys supplied as a free-flowing powder in bulk quantities or as powder compressed into tablets, or to dental mercury supplied in sachets or bulk quantities. This document is not applicable to other metallic materials in which an alloy powder reacts with an alloy that is liquid at ambient temperature to produce a solid metallic material intended for dental restoration. Specific qualitative and quantitative test methods for demonstrating freedom from unacceptable biological hazard are not included in this document. For the assessment of possible biological hazards, reference can be made to ISO 10993‑1 and ISO 7405. The scope of this document is restricted to dental amalgam products marketed in pre-capsulated form alone. Other products intended for use in the production of dental amalgam restorations (dental amalgam alloy as a free-flowing powder supplied in bulk masses, dental amalgam alloy powder supplied as compressed tablets and dental mercury sachets) are within the scope of ISO 24234.

ISO 20749:2017 specifies the requirements and test methods for dental amalgam products supplied to the user in capsules, pre-dosed with dental amalgam alloy and dental mercury in quantities suitable for the creation of a single dental restoration. ISO 20749:2017 specifies the requirements and test methods for dental amalgam alloys that are suitable for the preparation of dental amalgam and the capsule, together with the requirements and test methods for that dental amalgam and the requirements for packaging and marking. ISO 20749:2017 is not applicable to dental amalgam alloys supplied as a free-flowing powder in bulk quantities or as powder compressed into tablets, or to dental mercury supplied in sachets or bulk quantities. This document is not applicable to other metallic materials in which an alloy powder reacts with an alloy that is liquid at ambient temperature to produce a solid metallic material intended for dental restoration. Specific qualitative and quantitative test methods for demonstrating freedom from unacceptable biological hazard are not included in this document. For the assessment of possible biological hazards, reference can be made to ISO 10993‑1 and ISO 7405. The scope of this document is restricted to dental amalgam products marketed in pre-capsulated form alone. Other products intended for use in the production of dental amalgam restorations (dental amalgam alloy as a free-flowing powder supplied in bulk masses, dental amalgam alloy powder supplied as compressed tablets and dental mercury sachets) are within the scope of ISO 24234.

ISO 20749:2017 is classified under the following ICS (International Classification for Standards) categories: 11.060.10 - Dental materials. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 20749:2017 has the following relationships with other standards: It is inter standard links to ISO 20749:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase ISO 20749:2017 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 20749
First edition
2017-03
Dentistry — Pre-capsulated dental
amalgam
Médecine bucco-dentaire — Amalgame dentaire en capsules
prédosées
Reference number
©
ISO 2017
© ISO 2017, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – All rights reserved

Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Requirements . 3
4.1 Package and capsule contamination . 3
4.2 Chemical composition and purity of the dental amalgam alloy . 3
4.3 Large particles in the dental amalgam alloy powder . 3
4.4 Loss of mass from the capsule during mixing . 3
4.5 The yield of amalgam from the capsule . 3
4.6 Consistency of the dental amalgam from capsule to capsule . 4
4.7 Properties of the dental amalgam . 4
4.7.1 Creep . 4
4.7.2 Dimensional changes during hardening . 4
4.7.3 Compressive strength at 1 h . 4
4.7.4 Compressive strength at 24 h . 4
4.8 Appearance of the mixed dental amalgam before setting . 4
4.9 Length tolerance for the capsule . 4
5 Sampling . 5
6 Test methods . 5
6.1 Package and capsule contamination . 5
6.1.1 Principle . 5
6.1.2 Test sample . 5
6.1.3 Apparatus . 5
6.1.4 Procedure . 5
6.1.5 Expression of the results . 5
6.1.6 Report . 5
6.2 Chemical composition and purity of the dental amalgam alloy . 5
6.2.1 Principle . 5
6.2.2 Test sample . 6
6.2.3 Apparatus . 6
6.2.4 Procedure . 6
6.2.5 Expression of results . 6
6.2.6 Report . 6
6.3 Large particles in the dental amalgam alloy powder . 6
6.3.1 Principle . 6
6.3.2 Test sample . 7
6.3.3 Apparatus . 7
6.3.4 Test procedure . 7
6.3.5 Expression of the results . 7
6.3.6 Report . 7
6.4 Loss of mass from the capsule during mixing . 8
6.4.1 Principle . 8
6.4.2 Test sample . 8
6.4.3 Apparatus . 8
6.4.4 Test procedure . 8
6.4.5 Expression of the results . 9
6.4.6 Report . 9
6.5 Yield of amalgam from the capsule . 9
6.5.1 Principle . 9
6.5.2 Test sample . 9
6.5.3 Apparatus . 9
6.5.4 Test procedure .10
6.5.5 Expression of the results .10
6.5.6 Report .10
6.6 Consistency of the dental amalgam from capsule to capsule .10
6.6.1 Principle .10
6.6.2 Test sample .11
6.6.3 Apparatus .11
6.6.4 Test-piece production .12
6.6.5 Microhardness measurement .13
6.6.6 Expression of the results .13
6.6.7 Report .14
6.7 Properties of the dental amalgam .14
6.7.1 Principle .14
6.7.2 Sample.14
6.7.3 Mould for the preparation of cylindrical test-pieces for determining creep,
dimensional change during hardening and compressive strength .14
6.7.4 Preparation of cylindrical test-pieces to determine compliance with
the requirements for creep, dimensional change during hardening and
compressive strength . .18
6.7.5 Determination of creep .20
6.7.6 Determination of dimensional change during hardening .21
6.7.7 Determination of compressive strength .22
6.8 Appearance of the mixed dental amalgam before setting .23
6.8.1 Principle .23
6.8.2 Apparatus .24
6.8.3 Test procedure .24
6.8.4 Expression of the results .24
6.8.5 Report .25
6.9 Length tolerance for the capsule .25
6.9.1 Principle .25
6.9.2 Test sample .25
6.9.3 Apparatus .25
6.9.4 Test procedure .25
6.9.5 Expression of the results .25
6.9.6 Report .25
7 Marking, labelling and packaging .26
7.1 Packaging .26
7.2 Marking and labelling .26
7.2.1 Information.26
7.2.2 Labelling of a package for dental mercury .26
7.2.3 Labelling of the outer surface of package or container used for shipping .27
7.3 Manufacturer’s instructions .27
7.3.1 General instructions.27
7.3.2 Precautionary notes .27
Bibliography .28
iv © ISO 2017 – All rights reserved

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO’s adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: w w w . i s o .org/ iso/ foreword .html.
This document was prepared by ISO/TC 106, Dentistry, Subcommittee SC 1, Filling and restorative
materials.
Introduction
This is the first edition of this document. Its scope is limited solely to dental amalgam alloy and dental
mercury that are supplied pre-capsulated in masses that are sufficient to produce a mass of dental
amalgam that is considered to be suitable for a single small or medium size restoration in a single tooth.
Dental amalgam alloy and dental mercury are the essential and only components of dental amalgam
restorative material. This document specifies the requirements and the test methods for dental
amalgam alloy that is suitable for the preparation of dental amalgam, together with those for the set
dental amalgam, those for the capsules themselves and the requirements for packaging and marking.
This document has been developed in response to the UNEP Minamata Convention on Mercury. The
objective of the Minamata Convention is to reduce anthropogenic mercury pollution by restricting
the use of mercury, products containing mercury and materials that release mercury during use. In
this convention, dental amalgam is classified as a “mercury-added product”, for which parties to the
agreement are to adopt two or more measures from a list of nine. One of these is “restricting the
use of dental amalgam to its encapsulated form”. In some countries, the term encapsulated has been
interpreted as the pre-capsulated form alone. Given the increased vigilance on the use of dental amalgam
products since 2013, when the Minamata Agreement was signed, this document will enable countries
that do not allow the use of products other than those that are pre-capsulated to adopt an ISO standard
on dental amalgam. Not all of the membership of the UN has signed the Minamata Convention and in
non-signatory countries, dental amalgam products outside the scope of this document, but within the
scope of ISO 24234, will continue to be marketed. Thus, both standards are required to provide full
global coverage for compliance.
Although this document is based on ISO 24234, there have been significant technical changes. Also, the
requirements for the capsule that were in ISO 13897 have been transferred to this document, treating
a product that falls within the scope as an entity. This document differs technically from ISO 24234 in
the following respects:
— The scope of this document is restricted to pre-capsulated products alone.
— A requirement for packaging and capsule to be free from contamination is present.
— The requirement concerning foreign matter in the dental amalgam alloy powder has been removed.
— A requirement for loss of mass from the capsule during mixing has been added.
— A requirement for the yield of dental amalgam from a capsule replaces the requirement for the
masses of dental mercury and dental amalgam powder present before mixing.
— A requirement for the consistency in the ratio of dental mercury to dental amalgam alloy powder
in capsules has been changed radically. Determination of the effect of variation in this ratio upon
properties replaces weighing the dental mercury and the dental amalgam alloy powder.
— Requirements for the capsule have been introduced and revised technically.
A decision was taken not to alter requirements upon which capsulation has no bearing, these being:
— the requirements on chemical composition and purity of the dental amalgam alloy;
— the requirements for the properties of dental amalgam;
— the requirement for the appearance of dental amalgam before setting.
As with ISO 24234, the inclusion of a requirement for corrosion resistance was considered. However, it
was agreed that the data available were insufficient to set a corrosion resistance requirement in this
edition of this document. A requirement for the corrosion resistance will be set and incorporated at the
earliest possible date. It is recommended that in assessing corrosion resistance of a dental amalgam
product (relative to other dental amalgam products), reference can be made to ISO/TS 17988.
vi © ISO 2017 – All rights reserved

INTERNATIONAL STANDARD ISO 20749:2017(E)
Dentistry — Pre-capsulated dental amalgam
1 Scope
This document specifies the requirements and test methods for dental amalgam products supplied to
the user in capsules, pre-dosed with dental amalgam alloy and dental mercury in quantities suitable for
the creation of a single dental restoration.
This document specifies the requirements and test methods for dental amalgam alloys that are suitable
for the preparation of dental amalgam and the capsule, together with the requirements and test
methods for that dental amalgam and the requirements for packaging and marking.
This document is not applicable to dental amalgam alloys supplied as a free-flowing powder in bulk
quantities or as powder compressed into tablets, or to dental mercury supplied in sachets or bulk
quantities.
This document is not applicable to other metallic materials in which an alloy powder reacts with an
alloy that is liquid at ambient temperature to produce a solid metallic material intended for dental
restoration.
Specific qualitative and quantitative test methods for demonstrating freedom from unacceptable
biological hazard are not included in this document. For the assessment of possible biological hazards,
reference can be made to ISO 10993-1 and ISO 7405.
The scope of this document is restricted to dental amalgam products marketed in pre-capsulated
form alone. Other products intended for use in the production of dental amalgam restorations (dental
amalgam alloy as a free-flowing powder supplied in bulk masses, dental amalgam alloy powder supplied
as compressed tablets and dental mercury sachets) are within the scope of ISO 24234.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 286-2, Geometrical product specifications (GPS) — ISO code system for tolerances on linear sizes —
Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
ISO 3310-1, Test sieves — Technical requirements and testing — Part 1: Test sieves of metal wire cloth
ISO 3864-2, Graphical symbols — Safety colours and safety signs — Part 2: Design principles for product
safety labels
ISO 6344-1, Coated abrasives — Grain size analysis — Part 1: Grain size distribution test
ISO 7488, Dental amalgamators
ISO 13565-2, Geometrical Product Specifications (GPS) — Surface texture: Profile method; Surfaces having
stratified functional properties — Part 2: Height characterization using the linear material ratio curve
ISO 15223-1, Medical devices — Symbols to be used with medical device labels, labelling and information to
be supplied — Part 1: General requirements
Globally Harmonized System of Classification and Labelling of Chemicals (GHS). United Nations, New York
and Geneva, 5th Revised Edition, 2013, ISBN 978-92-1-117067-2
UN Recommendations on the Transport of Dangerous Goods, Model Regulations. United Nations, New York
and Geneva, 18th Edition, 2013, ISBN 978-92-1-193146-6
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 1942 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http:// www .electropedia .org/
— ISO Online browsing platform: available at http:// www .iso .org/ obp
3.1
dental amalgam alloy
alloy in fine particles, composed mainly of silver, tin and copper, which, when mixed with dental mercury
(3.2), produces a dental amalgam
3.2
dental mercury
mercury supplied for use in the preparation of dental amalgam
3.3
pre-capsulated product
product supplied in a sealed capsule that contains measured amounts of dental amalgam alloy (3.1)
powder and dental mercury (3.2) with masses that are appropriate for the production of a mass of dental
amalgam that is considered to be suitable for a single small or medium size restoration in a single tooth
Note 1 to entry: The dental amalgam alloy powder and dental mercury (3.2) are separated by a barrier that is
broken immediately prior to mixing to allow their contact. The capsule remains sealed until mixing has been
completed.
3.4
self-activating capsule
pre-capsulated product (3.3) capsule in which contact between the dental amalgam alloy (3.1) powder
and the dental mercury (3.2) occurs automatically during mixing
Note 1 to entry: There is another type of design that requires a physical action by the user to rupture the
separating barrier for activation (3.6) before placing the capsule in the mechanical mixing machine.
3.5
percentage by mass
mass fraction expressed as a percentage
Note 1 to entry: The terminology “mass fraction” is favoured when expressing a composition in which this is
measured by mass. However, for dental amalgam alloys (3.1), the terminology “by mass” is in general use. Because
it is the intention for this document to be user-friendly, the latter has been adopted. In both cases, the composition
is expressed as a percentage.
3.6
activation
action that renders the capsulated dental amalgam alloy (3.1) powder and dental mercury (3.2) mixable
3.7
dental amalgam pellet
coherent mass of dental amalgam that is produced by mixing and drops from the opened and
upended capsule
Note 1 to entry: A light tap of the rim of the open capsule on a hard surface may be required to dislodge the pellet
and is permitted.
2 © ISO 2017 – All rights reserved

4 Requirements
4.1 Package and capsule contamination
The interior of the packaging container and the outer surface of the capsules shall be free of both dental
mercury and dental amalgam alloy powder contamination when tested in accordance with 6.1.
4.2 Chemical composition and purity of the dental amalgam alloy
Table 1 — Requirements for chemical composition of the dental amalgam alloy
Mass fraction
Element
%
Silver ≥40
Tin ≤32
Copper ≤30
Indium ≤5
Palladium ≤1
Platinum ≤1
Zinc ≤2
Mercury ≤3
The manufacturer shall declare every element that is present intentionally and in a concentration
greater than or equal to 0,1 % (by mass). All alloying elements present in concentrations greater than
0,5 % (by mass) shall be given by name with percentage by mass values rounded to the nearest whole
percentage point. Alloying elements that are present in concentrations between 0,1 % and 0,5 % (by
mass) shall be named without a percentage value.
Determine the chemical composition in accordance with 6.2.
The chemical composition shall comply with Table 1.
The total for elements that are not declared by the manufacturer as alloying elements shall not exceed
0,1 % (by mass).
4.3 Large particles in the dental amalgam alloy powder
When compliance with this requirement is determined in accordance with 6.3, the proportion of the
dental amalgam alloy powder that occurs as particles that have a size greater than 150 μm shall not
exceed 0,1 % (by mass).
4.4 Loss of mass from the capsule during mixing
When compliance with this requirement is determined in accordance with 6.4, the average loss in mass
of dental mercury and dental amalgam alloy powder from 15 capsules (during mixing in accordance
with the manufacturer’s instructions) shall not exceed 0,5 mg.
Also, the loss from any one capsule shall not exceed 1 mg.
4.5 The yield of amalgam from the capsule
When compliance with this requirement is determined in accordance with 6.5, the average mass of the
pellet of dental amalgam obtained from a capsule (for a sample of 15 capsules) shall not be less than
95,0 % of the sum of the manufacturer’s stated masses for dental mercury and dental amalgam alloy in
the capsule.
Also, no capsule shall yield a pellet of dental amalgam that is less than 90,0 % of the sum of the
manufacturer’s stated masses for dental mercury and dental amalgam alloy in the capsule.
There may be some small free pieces of dental amalgam as well as the pellet. These are available for use
and are regarded as part of the yield, i.e. their mass should be added to that of the pellet.
4.6 Consistency of the dental amalgam from capsule to capsule
When compliance with this requirement is determined in accordance with 6.6, the mean value of the
hardness for dental amalgam produced from the content of any one capsule shall not be less than 85 %
of the overall mean value of the hardness of the dental amalgam obtained for a specified number of
capsules.
NOTE The mean value for the hardness of a test-piece is calculated from all measurements made on that
test-piece. The overall mean value for hardness is calculated from all measurements on all test-pieces.
4.7 Properties of the dental amalgam
Table 2 — Properties of the dental amalgam
Minimum compressive
Maximum Permitted dimensional Minimum compressive
strength at 24 h
creep change during hardening strength at 1 h
% % MPa
MPa
2,0 −0,10 to +0,15 100 350
4.7.1 Creep
When compliance with this requirement is determined in accordance with 6.7, the results for either
three out of three or four out of five test-pieces shall meet the requirement in Table 2.
4.7.2 Dimensional changes during hardening
When compliance with this requirement is determined in accordance with 6.7, the results for at least
four out of five test-pieces shall meet the requirement in Table 2.
4.7.3 Compressive strength at 1 h
When compliance with this requirement is determined in accordance with 6.7, the results for at least
four out of five test-pieces or eight out of 10 test-pieces shall meet the requirement in Table 2.
4.7.4 Compressive strength at 24 h
When compliance with this requirement is determined in accordance with 6.7, the results for at least
four out of five test-pieces or eight out of 10 test-pieces shall meet the requirement in Table 2.
4.8 Appearance of the mixed dental amalgam before setting
When compliance with this requirement is determined in accordance with 6.8, when the dental
amalgam alloy and dental mercury are mixed according to the manufacturer’s instructions, the dental
amalgam shall form a coherent plastic mass with a shiny surface before packing and remain a coherent
plastic mass after packing.
4.9 Length tolerance for the capsule
When compliance with this requirement is determined in accordance with 6.9, the overall length of the
activated capsule shall be within ±1 mm of the length specified by the manufacturer. All 10 capsules in
the sample tested shall meet the requirement.
4 © ISO 2017 – All rights reserved

5 Sampling
Procure containers of capsules of the same lot in packages that have been produced for retail.
NOTE The number of capsules required depends on the masses of dental amalgam alloy and dental mercury
in each.
6 Test methods
6.1 Package and capsule contamination
6.1.1 Principle
Any loss of either component from a capsule during transit is a concern. Such a loss can be detected by
visual examination using low power magnification.
6.1.2 Test sample
Test all containers holding the capsules from the sample procured for testing, as well as 25 capsules
selected at random from the same sample.
6.1.3 Apparatus
Stereomicroscope, ×10 magnification.
6.1.4 Procedure
Using the stereomicroscope, inspect the interior surfaces of all the containers holding capsules and the
external surfaces of the 25 capsules. Examine these for traces of dental amalgam alloy powder and
visible beads of dental mercury.
6.1.5 Expression of the results
Record the observations.
6.1.6 Report
6.1.6.1 General
If contamination is seen on the surface of a container, report this and the number of containers that is
contaminated.
If it is the capsule surface that is contaminated, report this and the number of capsules that is
contaminated.
6.1.6.2 Compliance
Report whether the product does or does not comply with the requirement for package and capsule
contamination, in accordance with 4.1.
6.2 Chemical composition and purity of the dental amalgam alloy
6.2.1 Principle
Chemical analysis of the dental amalgam alloy using an instrumented technique for metallic materials.
6.2.2 Test sample
Extract dental amalgam alloy powder from a capsule selected at random. This sample should not be
contaminated with the dental mercury during extraction from the capsule.
6.2.3 Apparatus
Recognized, instrumented analytical procedure, with a sensitivity adequate to determine the
composition of the dental amalgam alloy for the elements declared by the manufacturer in compliance
with 4.2.
NOTE Inductively-coupled plasma (ICP) spectroscopy is an example of a suitable analytical procedure.
6.2.4 Procedure
Determine the composition of the dental amalgam alloy for the elements declared by the manufacturer
in compliance with 4.2.
6.2.5 Expression of results
Record all elements detected in concentrations greater than 0,01 % (by mass) and their proportions as
percentages by mass.
For other elements that are detected in concentrations greater than 0,01 % (by mass) and below 0,1 %
(by mass), but are not alloying elements (declared as such by the manufacturer in compliance with 4.2),
sum these values and record the sum as the percentage (by mass) of other elements.
6.2.6 Report
6.2.6.1 General
Report the analytical method used. Report any irregularities in the test procedure used.
Report the percentages (by mass) for those elements that are alloying elements according to Table 1
and reported as such by the manufacturer. If any other element is declared by the manufacturer as an
alloying element, report this and its percentage (by mass).
Report the sum of the percentages (by mass) of undeclared elements present in concentrations greater
than 0,01 % (by mass).
Report each undeclared element that was found in a concentration greater than 0,1 % (by mass) by
name and the percentage (by mass).
6.2.6.2 Compliance
Report whether the product does or does not comply with the requirement for composition and purity
in accordance with 4.2
6.3 Large particles in the dental amalgam alloy powder
6.3.1 Principle
The large particles (defined as >150 μm in size) separated from the sample (a known mass of dental
amalgam powder) are weighted.
6 © ISO 2017 – All rights reserved

6.3.2 Test sample
Select and open a sufficient number of capsules to obtain a (10,0 ± 0,1) g sample of dental amalgam alloy
powder. This sample should not be contaminated with the dental mercury during extraction from the
capsules.
6.3.3 Apparatus
6.3.3.1 Chemical balance, having a resolution and accuracy of 1 mg.
6.3.3.2 Sieve, having a mesh size 150 μm that conforms to ISO 3310-1 with collection pan and cover.
6.3.3.3 Tweezers, with pointed ends.
6.3.3.4 Weighing boat, or similar.
6.3.3.5 Stereomicroscope, ×10 magnification.
6.3.4 Test procedure
Weigh the sample to an accuracy of 1 mg and record this as m .
p
Place the sample on the sieve. Hold the sieve assembly (consisting of collecting pan, sieve and cover) in
one hand and tap it gently against the other hand at a rate of approximately twice a second for 120 s.
Using the stereomicroscope, inspect the sieve at a magnification of ×10 for any foreign material and
remove any that is seen. Then, transfer the dental amalgam alloy particles remaining on the sieve to the
balance. Weigh these to an accuracy of 1 mg and record as m .
r
6.3.5 Expression of the results
Calculate w, the proportion of the dental amalgam alloy present as particles that have a size greater
than 150 μm (expressed as a percentage of the mass of the sample), as shown in Formula (1):
m
r
w =× 100 (%) (1)
m
p
where
m is the mass of dental amalgam alloy particles remaining on the sieve;
r
m is the mass of the powder sample.
p
6.3.6 Report
6.3.6.1 General
Report any irregularities in the test procedure. Report whether foreign material was found on the sieve.
Report the proportion of the dental amalgam alloy that is present as particles greater than 150 μm in
size, expressed as a percentage of the mass of the test sample.
6.3.6.2 Compliance
Report whether the product does or does not comply with the requirement for large particles in
accordance with 4.3.
6.4 Loss of mass from the capsule during mixing
6.4.1 Principle
The loss of content from the capsule during mixing is determined by weighing it initially and again after
mixing. Testing a number of capsules is required because the amount lost may vary from capsule to
capsule.
6.4.2 Test sample
Select 15 capsules at random.
6.4.3 Apparatus
6.4.3.1 Mechanical mixing machine for dental amalgam, that is recommended by the manufacturer
of the dental amalgam product and which complies with ISO 7488.
NOTE Traditionally, the mechanical mixer for dental amalgam has been called an amalgamator. The latter is
now a deprecated term.
6.4.3.2 Weighing boat, or similar (15 are required).
6.4.3.3 Chemical balance, having an accuracy and resolution of 0,1 mg.
6.4.3.4 Surgical gloves, latex or similar.
6.4.3.5 Stereomicroscope, ×10 magnification.
6.4.4 Test procedure
At all times, wear the surgical gloves when handling the capsules to avoid contaminating the surface.
Take the first capsule and blow oil-free compressed air over the surface to remove any adhering powder
and dust.
NOTE 1 Although, according to 4.1, the surface should be free from contamination, it is good laboratory
practice to do this.
Use the stereomicroscope to inspect the surface of the capsule for any remaining contaminant and for
any attached moulding flash. If either is present, remove it. Then inspect the surface of the capsule for
blemishes. If any blemishes are present, note these.
Place the capsule in the weighing boat and record their combined weights (m ). This and all subsequent
s
weighings are to be accurate to 0,1 mg.
Taking care not to score the plastic, place the weighed capsule in the mechanical mixing machine.
NOTE 2 Sharp edges on the metal fork (or similar device) that hold the capsule in the mechanical mixing
machine can cut small amounts of plastic from the capsule when the necessary force is applied to seat the capsule.
Such a loss can affect the result.
Mix, using the setting on the mechanical mixing machine and mixing time that are recommended by the
manufacturer for the mass of dental amalgam alloy that is being mixed. See 7.3.1.
Once again, taking care not to score its surface, remove the capsule from the mechanical mixing machine.
Use the stereomicroscope to inspect the surface for any marks that may have been produced when the
capsule was placed in or removed from the mechanical mixing machine. If any are seen, note these.
8 © ISO 2017 – All rights reserved

Then place the capsule in the weighing boat and leave at ambient temperature for 20 min. (The mixing
process generates heat which affects the weighing at the accuracy required, if the temperature of the
capsule is above ambient temperature.) It is necessary to let the temperature of the capsule equilibrate
with the ambient temperature before it is reweighed.
Reweigh the capsule and weighing boat (m ).
m
Repeat this procedure for the 14 other capsules.
6.4.5 Expressio
...


NORME ISO
INTERNATIONALE 20749
Première édition
2017-03
Médecine bucco-dentaire —
Amalgame dentaire en capsules
prédosées
Dentistry — Pre-capsulated dental amalgam
Numéro de référence
©
ISO 2017
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2017, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – Tous droits réservés

Sommaire Page
Avant-propos .v
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Exigences . 3
4.1 Contamination de l’emballage et de la capsule . 3
4.2 Composition chimique et pureté de l’alliage pour amalgame dentaire . 3
4.3 Grosses particules dans la poudre d’alliage pour amalgame dentaire . 3
4.4 Perte de masse de la capsule pendant le mélange . 4
4.5 Rendement en amalgame à partir de la capsule . 4
4.6 Consistance de l’amalgame dentaire selon les capsules . 4
4.7 Propriétés de l’amalgame dentaire . 4
4.7.1 Fluage . 4
4.7.2 Variations dimensionnelles durant le durcissement . 4
4.7.3 Résistance à la compression à 1 h . 4
4.7.4 Résistance à la compression à 24 h . 5
4.8 Aspect de l’amalgame dentaire mélangé avant la prise . 5
4.9 Tolérance de longueur de la capsule . 5
5 Échantillonnage . 5
6 Méthodes d’essai . 5
6.1 Contamination de l’emballage et de la capsule . 5
6.1.1 Principe . 5
6.1.2 Échantillon pour essai . 5
6.1.3 Appareillage . 5
6.1.4 Mode opératoire . 5
6.1.5 Expression des résultats . 5
6.1.6 Rapport . 6
6.2 Composition chimique et pureté de l’alliage pour amalgame dentaire . 6
6.2.1 Principe . 6
6.2.2 Échantillon pour essai . 6
6.2.3 Appareillage . 6
6.2.4 Mode opératoire . 6
6.2.5 Expression des résultats . 6
6.2.6 Rapport . 6
6.3 Grosses particules dans la poudre d’alliage pour amalgame dentaire . 7
6.3.1 Principe . 7
6.3.2 Échantillon pour essai . 7
6.3.3 Appareillage . 7
6.3.4 Mode opératoire d’essai . 7
6.3.5 Expression des résultats . 8
6.3.6 Rapport . 8
6.4 Perte de masse de la capsule pendant le mélange . 8
6.4.1 Principe . 8
6.4.2 Échantillon pour essai . 8
6.4.3 Appareillage . 8
6.4.4 Mode opératoire d’essai . 9
6.4.5 Expression des résultats . 9
6.4.6 Rapport .10
6.5 Rendement en amalgame à partir de la capsule .10
6.5.1 Principe .10
6.5.2 Échantillon pour essai .10
6.5.3 Appareillage .10
6.5.4 Mode opératoire d’essai .10
6.5.5 Expression des résultats .11
6.5.6 Rapport .11
6.6 Consistance de l’amalgame dentaire selon les capsules .11
6.6.1 Principe .11
6.6.2 Échantillon pour essai .11
6.6.3 Appareillage .12
6.6.4 Production des éprouvettes .13
6.6.5 Mesurage de la microdureté .14
6.6.6 Expression des résultats .15
6.6.7 Rapport .15
6.7 Propriétés de l’amalgame dentaire .15
6.7.1 Principe .15
6.7.2 Échantillon .15
6.7.3 Moule de préparation des éprouvettes cylindriques pour la détermination
du fluage, de la variation dimensionnelle durant le durcissement et de la
résistance à la compression .15
6.7.4 Préparation des éprouvettes cylindriques permettant de déterminer la
conformité aux exigences de fluage, de variation dimensionnelle et de
résistance à la compression .19
6.7.5 Détermination du fluage .21
6.7.6 Détermination de la variation dimensionnelle durant le durcissement .22
6.7.7 Détermination de la résistance à la compression .23
6.8 Aspect de l’amalgame dentaire mélangé avant la prise .25
6.8.1 Principe .25
6.8.2 Appareillage .25
6.8.3 Mode opératoire d’essai .25
6.8.4 Expression des résultats .26
6.8.5 Rapport .26
6.9 Tolérance de longueur de la capsule .26
6.9.1 Principe .26
6.9.2 Échantillon pour essai .26
6.9.3 Appareillage .26
6.9.4 Mode opératoire d’essai .26
6.9.5 Expression des résultats .26
6.9.6 Rapport .27
7 Marquage, étiquetage et emballage .27
7.1 Emballage .27
7.2 Marquage et étiquetage .27
7.2.1 Informations .27
7.2.2 Étiquetage d’un emballage applicable au mercure à usage dentaire .28
7.2.3 Étiquetage de la surface externe d’un emballage ou d’un contenant utilisé
pour l’expédition . .28
7.3 Instructions du fabricant .28
7.3.1 Instructions générales .28
7.3.2 Notes de précaution .29
Bibliographie .30
iv © ISO 2017 – Tous droits réservés

Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre noter des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/ patents).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute autre information au sujet de
l’adhésion de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les
obstacles techniques au commerce (OTC), voir le lien suivant: w w w . i s o .org/ iso/ foreword .html.
Le présent document a été élaboré par le comité technique ISO/TC 106, Médecine bucco-dentaire, sous-
comité SC 1, Produits pour obturation et restauration.
Introduction
Il s’agit de la première édition du présent document. Son champ d’application se limite exclusivement
à l’alliage pour amalgame dentaire et au mercure à usage dentaire qui sont fournis sous forme de
capsules prédosées dans des quantités suffisantes pour produire une masse d’amalgame dentaire jugée
appropriée pour une restauration de petite ou moyenne taille sur une seule dent.
L’alliage pour amalgame dentaire et le mercure à usage dentaire sont les seuls et uniques composants
des amalgames dentaires utilisés en matériaux de restauration. Le présent document spécifie d’une
part, les exigences et les méthodes d’essai applicables à l’alliage pour amalgame dentaire adapté à la
préparation d’amalgame dentaire, ainsi que celles relatives à l’amalgame dentaire après la prise et aux
capsules elles-mêmes, et d’autre part, les exigences relatives à l’emballage et au marquage.
Le présent document a été élaboré en réponse à la Convention UNEP de Minamata sur le mercure.
L’objectif de la Convention de Minamata est de réduire la pollution au mercure d’origine humaine
en limitant l’utilisation de mercure, de produits contenant du mercure et de matériaux libérant du
mercure pendant leur utilisation. Dans cette convention, l’amalgame dentaire est classé comme un
«produit contenant du mercure comme additif» pour lequel les parties impliquées dans la convention
doivent adopter au moins deux mesures parmi une liste de neuf. L’une d’entre elles consiste à «limiter
l’utilisation de l’amalgame dentaire à sa forme encapsulée». Dans certains pays, le terme encapsulé a
été interprété comme étant uniquement la forme de capsule prédosée. Étant donné la vigilance accrue
portée à l’utilisation d’amalgames dentaires depuis 2013, date à laquelle la Convention de Minamata
a été signée, le présent document permettra aux pays qui n’autorisent pas l’utilisation de produits
autres que ceux présentés sous la forme de capsules prédosées d’adopter une norme ISO sur l’amalgame
dentaire. Les membres des Nations-Unies n’ont pas tous signé la Convention de Minamata et, dans
les pays non signataires, les amalgames dentaires qui ne font pas partie du domaine d’application du
présent document mais de celui de l’ISO 24234, continueront d’être commercialisés. Ainsi, les deux
normes sont requises pour un respect total de la conformité.
Bien que le présent document repose sur l’ISO 24234, d’importantes modifications techniques ont
été apportées. De plus, les exigences applicables aux capsules qui figuraient dans l’ISO 13897, ont été
transférées au présent document, en considérant un produit du domaine d’application comme une
entité. Les modifications techniques du présent document par rapport à l’ISO 24234 sont les suivantes:
— Le domaine d’application du présent document est limité aux produits sous forme de capsules
prédosées uniquement.
— Une exigence de non-contamination et d’emballage de la capsule est présente.
— L’exigence concernant les substances étrangères présentes dans la poudre d’alliage pour amalgame
dentaire a été supprimée.
— Une exigence relative à la perte de masse de la capsule pendant le mélange a été ajoutée.
— Une exigence concernant le rendement d’amalgame dentaire à partir d’une capsule remplace
l’exigence relative aux masses de mercure à usage dentaire et de poudre pour amalgame dentaire
présentes avant le mélange.
— Une exigence de cohérence du rapport entre le mercure à usage dentaire et la poudre d’alliage
pour amalgame dentaire en capsules a été radicalement modifiée. La détermination de l’effet de
la variation de ce rapport sur les propriétés remplace la pesée du mercure à usage dentaire et la
poudre d’alliage pour amalgame dentaire.
— Des exigences relatives à la capsule ont été introduites et ont fait l’objet d’une révision technique.
Une décision a été prise de ne pas modifier les exigences sur lesquelles l’encapsulation n’avait aucune
incidence, à savoir:
— les exigences sur la composition chimique et la pureté de l’alliage pour amalgame dentaire;
vi © ISO 2017 – Tous droits réservés

— les exigences relatives aux propriétés de l’amalgame dentaire;
— l’exigence relative à l’aspect de l’amalgame dentaire avant la prise.
Comme avec l’ISO 24234, l’inclusion d’une exigence relative à la résistance à la corrosion a été évaluée.
Cependant, il a été convenu que les données disponibles étaient insuffisantes pour établir une exigence
relative à la résistance à la corrosion dans l’édition du présent document. Une exigence relative à la
résistance à la corrosion sera définie dès que possible. Lors de l’évaluation de la résistance à la corrosion
d’un amalgame dentaire (par rapport à d’autres amalgames dentaires, il est possible de se référer à
l’ISO/TS 17988).
NORME INTERNATIONALE ISO 20749:2017(F)
Médecine bucco-dentaire — Amalgame dentaire en
capsules prédosées
1 Domaine d’application
Le présent document spécifie les exigences et les méthodes d’essai applicables aux amalgames dentaires
fournis à l’utilisateur sous forme de capsules, prédosées avec l’alliage pour amalgame dentaire et le
mercure à usage dentaire dans des quantités appropriées pour créer une seule restauration dentaire.
Le présent document spécifie les exigences et les méthodes d’essai applicables aux alliages pour
amalgame dentaire utilisés dans la préparation des amalgames dentaires et des capsules, les exigences
et les méthodes d’essai relatives à ces amalgames dentaires et les exigences d’emballage et de marquage.
Le présent document n’est applicable ni aux alliages pour amalgame dentaire fournis sous forme de
poudre fluide en vrac ou de poudre sous forme de comprimés ni au mercure à usage dentaire fourni
sous forme de sachets ou en vrac.
Le présent document n’est pas applicable à d’autres matériaux métalliques dans lesquels une poudre
d’alliage réagit avec un alliage liquide à température ambiante pour produire un matériau métallique
solide destiné à la restauration dentaire.
Le présent document ne comporte aucune méthode d’essai qualitative et quantitative spécifique
démontrant l’absence de dangers biologiques inacceptables. Pour évaluer la possibilité de tels dangers,
il est possible de se référer à l’ISO 10993-1 et à l’ISO 7405.
Le domaine d’application du présent document est limité aux amalgames dentaires commercialisés sous
forme de capsules prédosées uniquement. Les autres produits destinés à être utilisés pour la production
de restaurations en amalgame dentaire (alliage d’amalgame dentaire sous forme de poudre fluide en
vrac, poudre d’alliage pour amalgame dentaire sous forme de comprimés et sachets de mercure à usage
dentaire) font partie du domaine d’application de l’ISO 24234.
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 286-2, Spécification géométrique des produits (GPS) — Système de codification ISO pour les tolérances
sur les tailles linéaires — Partie 2: Tableaux des classes de tolérance normalisées et des écarts limites des
alésages et des arbres
ISO 3310-1, Tamis de contrôle — Exigences techniques et vérifications — Partie 1: Tamis de contrôle en
tissus métalliques
ISO 3864-2, Symboles graphiques — Couleurs de sécurité et signaux de sécurité — Partie 2: Principes de
conception pour l’étiquetage de sécurité des produits
ISO 6344-1, Abrasifs appliqués — Granulométrie — Partie 1: Contrôle de la distribution granulométrique
ISO 7488, Amalgamateurs dentaires
ISO 13565-2, Spécification géométrique des produits (GPS) — État de surface: Méthode du profil; surfaces
ayant des propriétés fonctionnelles différentes suivant les niveaux — Partie 2: Caractérisation des hauteurs
par la courbe de taux de longueur portante
ISO 15223-1, Dispositifs médicaux — Symboles à utiliser avec les étiquettes, l’étiquetage et les informations
à fournir relatifs aux dispositifs médicaux — Partie 1: Exigences générales
Système général harmonisé de classification et d’étiquetage des produits chimiques (SGH). Organisation
ème
des Nations Unies, New York et Genève, 5 édition révisée, 2013, ISBN 978-92-1-117067-2
Recommandations de l’Organisation des Nations Unies sur le transport de marchandises dangereuses,
ème
Règlement type. Organisation des Nations Unies, New York et Genève, 18 édition, 2013, ISBN 978-92-
1-193146-6
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants et ceux donnés dans
l’ISO 1942 s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— IEC Electropedia: disponible à l’adresse http:// www .electropedia .org/
— ISO Online browsing platform: disponible à l’adresse http:// www .iso .org/ obp
3.1
alliage pour amalgame dentaire
alliage en fines particules, composé principalement d’argent, d’étain et de cuivre qui, lorsqu’il est
mélangé à du mercure à usage dentaire (3.2), donne un amalgame dentaire
3.2
mercure à usage dentaire
mercure fourni pour servir à la préparation d’amalgames dentaires
3.3
capsule prédosée
produit fourni dans une capsule fermée qui contient des quantités mesurées de poudre d’alliage pour
amalgame dentaire (3.1) et de mercure à usage dentaire (3.2) pour la production d’amalgame dentaire,
avec des masses de poudre et de mercure considérées comme appropriées pour une restauration de
petite ou de moyenne taille sur une seule dent
Note 1 à l’article: à l’Article La poudre d’alliage pour amalgame dentaire et le mercure à usage dentaire (3.2) sont
séparés par une barrière qui est rompue juste avant le mélange permettant leur mise en contact. La capsule reste
fermée jusqu’à ce que le mélange soit terminé.
3.4
capsule auto-activante
capsule prédosée (3.3) dans laquelle la mise en contact entre la poudre d’alliage pour amalgame dentaire
(3.1) et le mercure à usage dentaire (3.2) a lieu automatiquement pendant le mélange
Note 1 à l’article: à l’Article Il existe un autre type de modèle qui, pour permettre l’activation (3.6), nécessite une
action physique de la part de l’utilisateur pour rompre la barrière de séparation avant de placer la capsule dans
le mélangeur mécanique.
3.5
pourcentage en masse
fraction massique exprimée en pourcentage
Note 1 à l’article: à l’Article La terminologie «fraction massique» est privilégiée pour exprimer composition
mesurée en masse. Cependant, pour l’alliage pour amalgame dentaire (3.1), la terminologie «en masse» est
généralement utilisée. L’objectif de la présente norme étant d’être facile à utiliser, la dernière terminologie a été
adoptée. Dans les deux cas, la composition est exprimée en pourcentage.
2 © ISO 2017 – Tous droits réservés

3.6
activation
action permettant à la poudre d’alliage pour amalgame dentaire (3.1) sous forme de capsules prédosées
et au mercure à usage dentaire (3.2) de pouvoir être mélangés
3.7
masse d’amalgame dentaire
masse consistante d’amalgame dentaire produite par le mélange et qui tombe de la capsule renversée
Note 1 à l’article: à l’Article Il peut être nécessaire de tapoter légèrement le bord de la capsule ouverte sur une
surface dure pour déloger la masse d’amalgame.
4 Exigences
4.1 Contamination de l’emballage et de la capsule
Lorsque l’essai est effectué conformément à 6,1, l’intérieur de l’emballage et la surface extérieure de
la capsule ne doivent présenter aucune trace de contamination par le mercure à usage dentaire et la
poudre d’alliage pour amalgame dentaire.
4.2 Composition chimique et pureté de l’alliage pour amalgame dentaire
Tableau 1 — Exigences de composition chimique de l’alliage pour amalgame dentaire
Fraction massique
Élément
%
Argent ≥40
Étain ≤32
Cuivre ≤30
Indium ≤5
Palladium ≤1
Platine ≤1
Zinc ≤2
Mercure ≤3
Le fabricant doit déclarer tous les éléments intentionnellement présents et à une concentration égale
ou supérieure à 0,1 % (en masse). Tous les éléments d’alliage présents à une concentration supérieure
à 0,5 % (en masse) doivent être identifiés par leur nom, avec des pourcentages en masse arrondis au
point de pourcentage le plus proche. Les éléments d’alliage présents à une concentration comprise
entre 0,1 % et 0,5 % (en masse) doivent être identifiés par leur nom mais sans pourcentage.
Déterminer la composition chimique conformément à 6.2.
La composition chimique doit être conforme au Tableau 1.
Le total des éléments non déclarés par le fabricant comme des éléments d’alliage ne doit pas
excéder 0,1 % (en masse).
4.3 Grosses particules dans la poudre d’alliage pour amalgame dentaire
Lorsque la conformité à cette exigence est déterminée conformément à 6.3, la proportion de poudre
d’alliage pour amalgame dentaire présente sous forme de particules d’une granulométrie supérieure à
150 µm ne doit pas excéder 0,1 % (en masse).
4.4 Perte de masse de la capsule pendant le mélange
Lorsque la conformité à cette exigence est déterminée conformément à 6.4, la perte de masse moyenne
du mercure à usage dentaire et de la poudre d’alliage pour amalgame dentaire des 15 capsules (pendant
le mélange suivant les instructions du fabricant) ne doit pas excéder 0,5 mg.
De plus, la perte d’une capsule ne doit pas excéder 1 mg.
4.5 Rendement en amalgame à partir de la capsule
Lorsque la conformité à cette exigence est déterminée conformément à 6.5, la masse moyenne de
l’amalgame dentaire obtenue à partir d’une capsule (pour un échantillon de 15 capsules) ne doit pas
être inférieure à 95,0 % de la somme des masses déclarées par le fabricant pour le mercure à usage
dentaire et l’alliage pour amalgame dentaire dans la capsule.
De plus, aucune capsule ne doit donner un rendement en amalgame dentaire inférieur à 90,0 % de
la somme des masses déclarées par le fabricant pour le mercure à usage dentaire et l’alliage pour
amalgame dentaire dans la capsule.
Des petits morceaux d’amalgame dentaire peuvent être présents en plus de la masse d’amalgame
principale. Ils peuvent être utilisés et considérés comme faisant partie du rendement, ce qui signifie
qu’il convient d’ajouter leur masse à celle de la masse d’amalgame principale.
4.6 Consistance de l’amalgame dentaire selon les capsules
Lorsque la conformité à cette exigence est déterminée conformément à 6.6, la valeur moyenne de la
dureté de l’amalgame dentaire produit à partir du contenu d’une capsule ne doit pas être inférieure
à 85 % de la valeur moyenne globale de la dureté de l’amalgame dentaire obtenue pour un nombre
spécifié de capsules.
NOTE La valeur moyenne de la dureté d’une éprouvette est calculée d’après toutes les mesures obtenues sur
cette éprouvette. La valeur moyenne globale de la dureté est calculée d’après toutes les mesures obtenues sur
toutes les éprouvettes.
4.7 Propriétés de l’amalgame dentaire
Tableau 2 — Propriétés de l’amalgame dentaire
Variation dimensionnelle
Résistance à la compression
Fluage Résistance à la compression
autorisée durant le durcis-
minimale à 24 h
maximal minimale à 1 h
sement
% MPa
MPa
%
2,0 −0,10 à +0,15 100 350
4.7.1 Fluage
Lorsque la conformité à cette exigence est déterminée conformément à 6,7, les résultats de trois
éprouvettes sur trois, ou quatre éprouvettes sur cinq, doivent respecter l’exigence du Tableau 2.
4.7.2 Variations dimensionnelles durant le durcissement
Lorsque la conformité à cette exigence est déterminée conformément à 6.7, les résultats d’au moins
quatre éprouvettes sur cinq doivent respecter l’exigence du Tableau 2.
4.7.3 Résistance à la compression à 1 h
Lorsque la conformité à cette exigence est déterminée conformément à 6.7, les résultats d’au moins
quatre éprouvettes sur cinq ou huit éprouvettes sur dix doivent respecter l’exigence du Tableau 2.
4 © ISO 2017 – Tous droits réservés

4.7.4 Résistance à la compression à 24 h
Lorsque la conformité à cette exigence est déterminée conformément à 6.7, les résultats d’au moins
quatre éprouvettes sur cinq ou huit éprouvettes sur dix doivent respecter l’exigence du Tableau 2.
4.8 Aspect de l’amalgame dentaire mélangé avant la prise
Lorsque la conformité à cette exigence est déterminée conformément à 6.8, lorsque l’alliage pour
amalgame dentaire et le mercure à usage dentaire sont mélangés conformément aux instructions du
fabricant, l’amalgame dentaire doit former une masse consistante modelable de surface brillante avant
la condensation et rester consistante et modelable après.
4.9 Tolérance de longueur de la capsule
Lorsque la conformité à cette exigence est déterminée conformément à 6.9, la longueur globale de la
capsule activée doit être égale, à 1 mm près, à la longueur spécifiée par le fabricant. Les 10 capsules de
l’échantillon soumis à essai doivent toutes satisfaire à l’exigence.
5 Échantillonnage
Se procurer des contenants de capsules du même lot, dans des emballages destinés à la vente au détail.
NOTE Le nombre de capsules requis dépend des masses de l’alliage pour amalgame dentaire et du mercure à
usage dentaire dans chaque capsule.
6 Méthodes d’essai
6.1 Contamination de l’emballage et de la capsule
6.1.1 Principe
Toute perte de composant d’une capsule pendant le transport est problématique. Cette perte peut être
détectée en procédant à un examen visuel sous un faible grossissement.
6.1.2 Échantillon pour essai
Soumettre à essai tous les contenants de capsules de l’échantillon utilisé pour l’essai, ainsi
que 25 capsules sélectionnées de façon aléatoire parmi ce même échantillon.
6.1.3 Appareillage
Microscope stéréoscopique, grossissement × 10.
6.1.4 Mode opératoire
À l’aide du microscope stéréoscopique, inspecter les surfaces intérieures de tous les contenants de
capsules ainsi que les surfaces extérieures des 25 capsules. Les examiner pour déceler toute trace
éventuelle de poudre d’alliage pour amalgame dentaire et toute bille visible de mercure à usage dentaire.
6.1.5 Expression des résultats
Consigner les observations.
6.1.6 Rapport
6.1.6.1 Généralités
En cas de contamination observée sur la surface d’un contenant, consigner cette observation ainsi que
le nombre de contenants contaminés.
Si la contamination concerne la surface de la capsule, consigner ce fait ainsi que le nombre de capsules
contaminées.
6.1.6.2 Conformité
Indiquer si le produit est conforme ou non à l’exigence de contamination et d’emballage de la capsule,
conformément à 4.1.
6.2 Composition chimique et pureté de l’alliage pour amalgame dentaire
6.2.1 Principe
Analyse chimique de l’alliage pour amalgame dentaire selon une technique instrumentale pour
matériaux métalliques.
6.2.2 Échantillon pour essai
Extraire la poudre d’alliage pour amalgame dentaire d’une capsule sélectionnée de façon aléatoire. Il
convient que cet échantillon ne soit pas contaminé par le mercure à usage dentaire pendant l’extraction
de la capsule.
6.2.3 Appareillage
Mode opératoire analytique instrumental reconnu ayant une sensibilité adéquate pour
déterminer la composition de l’alliage pour amalgame dentaire en éléments déclarés par le fabricant
conformément à 4.2.
NOTE Une spectroscopie à plasma induit par haute fréquence (ICP) est un exemple de mode opératoire
analytique adéquat.
6.2.4 Mode opératoire
Déterminer la composition de l’alliage pour amalgame dentaire en éléments déclarés par le fabricant
conformément à 4.2.
6.2.5 Expression des résultats
Consigner tous les éléments détectés à des concentrations supérieures à 0,01 % (en masse) ainsi que
leurs proportions en pourcentages en masse.
Pour les autres éléments détectés à des concentrations supérieures à 0,01 % (en masse) et inférieures
à 0,1 % (en masse), mais qui ne sont pas des éléments d’alliage (déclarés comme tels par le fabricant
conformément à 4.2), additionner ces valeurs et indiquer la somme sous forme de pourcentage (en
masse) d’autres éléments.
6.2.6 Rapport
6.2.6.1 Généralités
Indiquer la méthode analytique utilisée. Noter toutes les irrégularités observées pendant le mode
opératoire d’essai utilisé.
6 © ISO 2017 – Tous droits réservés

Consigner les pourcentages (en masse) des éléments qui sont des éléments d’alliage selon le Tableau 1 et
déclarés comme tels par le fabricant. Si un autre élément est déclaré par le fabricant comme un élément
d’alliage, le mentionner et indiquer son pourcentage (en masse).
Indiquer la somme des pourcentages (en masse) des éléments non déclarés présents à des concentrations
supérieures à 0,01 % (en masse).
Indiquer chaque élément non déclaré présent à une concentration supérieure à 0,1 % (en masse) par son
nom et son pourcentage (en masse).
6.2.6.2 Conformité
Indiquer si le produit est conforme ou non à l’exigence de composition et de pureté conformément à 4.2.
6.3 Grosses particules dans la poudre d’alliage pour amalgame dentaire
6.3.1 Principe
Pesée des grosses particules (définies comme ayant une granulométrie supérieure à 150 µm) séparées
de l’échantillon (une masse connue de poudre pour amalgame dentaire).
6.3.2 Échantillon pour essai
Sélectionner et ouvrir un nombre suffisant de capsules pour obtenir un échantillon de poudre d’alliage
pour amalgame dentaire de (10,0 ± 0,1) g. Il convient que cet échantillon ne soit pas contaminé par le
mercure à usage dentaire pendant l’extraction des capsules.
6.3.3 Appareillage
6.3.3.1 Balance chimique, d’une résolution et d’une précision de 1 mg.
6.3.3.2 Tamis, d’une ouverture de maille de 150 µm conforme à l’ISO 3310-1 avec bac récepteur et
couvercle.
6.3.3.3 Pinces, à extrémités pointues.
6.3.3.4 Coupelle de pesée, ou contenant équivalent.
6.3.3.5 Microscope stéréoscopique, grossissement × 10.
6.3.4 Mode opératoire d’essai
Peser l’échantillon avec une précision de 1 mg et enregistrer cette masse en tant que m .
p
Placer l’échantillon sur le tamis. Tenir l’ensemble de tamisage (constitué du bac récepteur, du tamis et
du couvercle) dans une main et le tapoter doucement contre l’autre main à raison d’environ deux fois par
seconde pendant 120 s. À l’aide du microscope stéréoscopique, examiner le tamis sous un grossissement
de × 10 pour voir s’il contient des substances étrangères et éliminer toutes les substances étrangères
visibles. Transférer ensuite les particules d’alliage pour amalgame dentaire restant sur le tamis sur la
balance. Les peser avec une précision de 1 mg et enregistrer cette masse en tant que m .
r
6.3.5 Expression des résultats
Calculer la proportion d’alliage pour amalgame dentaire, w, présent sous forme de particules ayant une
granulométrie supérieure à 150 µm (exprimée en pourcentage de la masse de l’échantillon) comme
indiqué dans la Formule (1):
m
r
w =× 100 (%) (1)
m
p

m est la masse de particules d’alliage pour amalgame dentaire restant sur le tamis;
r
m est la masse de l’échantillon de poudre.
p
6.3.6 Rapport
6.3.6.1 Généralités
Noter toutes les irrégu
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...