ISO 8253-2:2009
(Main)Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test signals
Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test signals
ISO 8253-2:2009 specifies relevant test signal characteristics, requirements for free, diffuse, and quasi‑free sound fields, and procedures for sound field audiometry using pure tones, frequency-modulated tones or other narrow-band test signals presented by means of one or more loudspeakers. The primary purpose is the determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz, but this range can be extended to 20 Hz to 16 000 Hz. ISO 8253-2:2009 does not include specifications for the use of hand-held loudspeakers. Speech as a test signal is not covered. The purpose of ISO 8253-2:2009 is to ensure that tests of hearing, using sound field audiometry, give as high a degree of accuracy and reproducibility as possible. Examples of graphical representations of the results are given.
Acoustique — Méthodes d'essais audiométriques — Partie 2: Audiométrie en champ acoustique avec des sons purs et des bruits à bande étroite comme signaux d'essai
L'ISO 8253-2:2009 spécifie les caractéristiques utiles des signaux d'essai, les exigences relatives aux champs acoustiques libre, diffus et quasi libre, ainsi que les modes opératoires s'appliquant à l'audiométrie en champ acoustique réalisée à l'aide de sons purs, de sons modulés en fréquence ou d'autres signaux d'essai de bande étroite émis par un ou plusieurs haut-parleurs. L'objectif principal est la détermination des niveaux liminaires d'audition dans la gamme de fréquences comprises entre 125 Hz et 8 000 Hz, celle-ci pouvant être étendue entre 20 Hz et 16 000 Hz. L'ISO 8253-2:2009 ne comporte pas de spécifications relatives à l'utilisation de haut-parleurs portatifs. Elle ne couvre pas les essais vocaux. L'objectif de l'ISO 8253-2:2009 est de garantir un degré de précision et de reproductibilité des essais d'audition effectués par audiométrie en champ acoustique aussi élevé que possible. Des exemples de représentations graphiques des résultats d'essai y sont donnés.
General Information
Relations
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 8253-2
Second edition
2009-12-15
Acoustics — Audiometric test methods —
Part 2:
Sound field audiometry with pure-tone
and narrow-band test signals
Acoustique — Méthodes d'essais audiométriques —
Partie 2: Audiométrie en champ acoustique avec des sons purs et des
bruits à bande étroite comme signaux d'essai
Reference number
©
ISO 2009
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2009
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2009 – All rights reserved
Contents Page
Foreword .iv
Introduction.v
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 Test signal characteristics .3
4.1 General .3
4.2 Pure tones .3
4.3 FM tones.4
4.4 Narrow bands of noise.4
4.5 Harmonic distortion .4
4.6 Signal gating .5
4.7 Signal level control.5
4.8 Means and scales for calibration.5
5 Sound field characteristics.6
5.1 General .6
5.2 Free sound field.6
5.3 Diffuse sound field .6
5.4 Quasi-free sound field.7
6 Ambient noise levels in the test room.7
7 Preparation and instruction of test subject.7
8 Determination of hearing threshold level .8
8.1 General .8
8.2 Monaural testing.8
8.3 Binaural testing .8
9 Testing with a hearing aid .8
10 Screening audiometry.8
11 Reporting of data.10
11.1 General .10
11.2 Equipment calibrated by hearing level.10
11.3 Equipment calibrated by sound pressure level .10
12 Maintenance and calibration of equipment .10
12.1 General .10
12.2 Intervals between tests.10
12.3 Stage A: routine examination and listening tests.11
12.4 Stage B: periodic electroacoustic tests.11
12.5 Stage C: basic calibration tests .12
Annex A (informative) Graphical display of results.13
Annex B (informative) Correction values for 45° and 90° angles of incidence.15
Bibliography.16
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 8253-2 was prepared by Technical Committee ISO/TC 43, Acoustics.
This second edition cancels and replaces the first edition (ISO 8253-2:1992), of which it constitutes a minor
revision.
ISO 8253 consists of the following parts, under the general title Acoustics — Audiometric test methods:
⎯ Part 1: Basic pure-tone air and bone conduction threshold audiometry
⎯ Part 2: Sound field audiometry with pure-tone and narrow-band test signals
⎯ Part 3: Speech audiometry
iv © ISO 2009 – All rights reserved
Introduction
ISO 8253-1 covers procedures for the determination of thresholds of hearing using pure tones presented to
the subject by means of earphone or bone vibrator.
This part of ISO 8253 covers procedures for the determination of thresholds of hearing in a sound field. In
general, sound field testing implies binaural Iistening to a test signal, presented by means of one or more
loudspeakers in a test room. The test signal may be a pure tone, a frequency-modulated tone or a narrow
band of noise. The acoustical characteristics of the sound field are determined by the choice of test signal, by
the number and acoustical properties of the loudspeakers used, as well as by the acoustical characteristics of
the test room.
Sound field audiometry may be used for various purposes, e.g. the evaluation of hearing acuity in young
children and the determination of the functional gain of a hearing aid when worn by a particular listener.
INTERNATIONAL STANDARD ISO 8253-2:2009(E)
Acoustics — Audiometric test methods —
Part 2:
Sound field audiometry with pure-tone and narrow-band test
signals
1 Scope
This part of ISO 8253 specifies relevant test signal characteristics, requirements for free, diffuse, and
quasi-free sound fields, and procedures for sound field audiometry using pure tones, frequency-modulated
tones or other narrow-band test signals presented by means of one or more loudspeakers. The primary
purpose is the determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz, but this
range can be extended to 20 Hz to 16 000 Hz.
This part of ISO 8253 does not include specifications for the use of hand-held loudspeakers. Speech as a test
signal is not covered.
The purpose of this part of ISO 8253 is to ensure that tests of hearing, using sound field audiometry, give as
high a degree of accuracy and reproducibility as possible.
Examples of graphical representations of the results are given in Annex A.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 226, Acoustics — Normal equal-loudness-level contours
ISO 266, Acoustics — Preferred frequencies
ISO 389-7, Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference
threshold of hearing under free-field and diffuse-field listening conditions
1)
ISO 8253-1:— , Acoustics — Audiometric test methods — Part 1: Basic pure-tone air and bone conduction
threshold audiometry
IEC 60581-7:1986, High fidelity audio equipment and systems — Minimum performance requirements —
Part 7: Loudspeakers
IEC 60645-1, Electroacoustics — Audiometric equipment — Part 1: Pure-tone audiometers
IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications
1) To be published. (Revision of ISO 8253-1:1989)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
air conduction
transmission of signal through the external and middle ear to the inner ear
3.2
otologically normal person
person in a normal state of health who is free from all signs or symptoms of ear disease and from obstructing
wax in the ear canal, and who has no history of undue exposure to noise, exposure to potentially ototoxic
drugs, or of familial hearing loss
3.3
reference point
midpoint of a straight line connecting the ear canal openings of the listener when positioned in the Iistening
position in the sound field
3.4
reference axis
axis perpendicular to the radiating surface of the loudspeaker
NOTE 1 For single radiator or horn loudspeakers, the axis passes through the geometric centre of the diaphragm or
the horn.
NOTE 2 For multi-unit loudspeakers, the position of the axis is defined by the manufacturer.
3.5
threshold of hearing
level of a sound at which, under specified conditions, a person gives 50 % of correct detection responses on
repeated trials
3.6
threshold sound pressure level
for a given listener, a specified signal and a specified manner of signal presentation, sound pressure level at
the reference point (3.3) in the specific sound field, in the absence of the listener, which in the presence of
the listener in the test position would correspond to the threshold of hearing (3.5) of the listener
3.7
reference threshold sound pressure level
for a specific signal and a specified manner of signal presentation, median value of the threshold sound
pressure levels (3.6) of a sufficiently lar
...
NORME ISO
INTERNATIONALE 8253-2
Deuxième édition
2009-12-15
Acoustique — Méthodes d'essais
audiométriques —
Partie 2:
Audiométrie en champ acoustique avec
des sons purs et des bruits à bande
étroite comme signaux d'essai
Acoustics — Audiometric test methods —
Part 2: Sound field audiometry with pure-tone and narrow-band test
signals
Numéro de référence
©
ISO 2009
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2009
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2009 – Tous droits réservés
Sommaire Page
Avant-propos .iv
Introduction.v
1 Domaine d'application .1
2 Références normatives.1
3 Termes et définitions .2
4 Caractéristiques des signaux d'essai .3
4.1 Généralités .3
4.2 Sons purs .4
4.3 Sons FM.4
4.4 Bandes de bruit étroites .4
4.5 Distortion harmonique.5
4.6 Suppression du signal.5
4.7 Commande de niveau du signal .5
4.8 Moyens et échelles d'étalonnage.6
5 Caractéristiques du champ acoustique .6
5.1 Généralités .6
5.2 Champ acoustique libre.6
5.3 Champ acoustique diffus.7
5.4 Champ acoustique quasi libre .7
6 Niveau de bruit ambiant dans la salle d'essai .8
7 Préparation et information des sujets.8
8 Détermination du niveau liminaire d'audition .8
8.1 Généralités .8
8.2 Écoute monaurale .10
8.3 Écoute binaurale.10
9 Essais avec appareil de correction auditive.10
10 Audiométrie de dépistage.10
11 Rapport d'essai.10
11.1 Généralités .10
11.2 Appareillage étalonné par rapport au niveau d'audition.11
11.3 Appareillage étalonné par rapport au niveau de pression acoustique.11
12 Entretien et étalonnage de l'appareillage .11
12.1 Généralités .11
12.2 Intervalles entre les essais.11
12.3 Étape A: examens de routine et essais d'écoute .12
12.4 Étape B: essais électroacoustiques périodiques .12
12.5 Étape C: essais d'étalonnage de base .13
Annexe A (informative) Représentation graphique des résultats.14
Annexe B (informative) Valeurs de correction à appliquer pour des angles d'incidence de 45° et
90° .16
Bibliographie.17
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 8253-2 a été élaborée par le comité technique ISO/TC 43, Acoustique.
Cette deuxième édition annule et remplace la première édition (ISO 8253-2:1992), qui a fait l'objet d'une
révision mineure.
L'ISO 8253 comprend les parties suivantes, présentées sous le titre général Acoustique — Méthodes d'essais
audiométriques:
⎯ Partie 1: Audiométrie liminaire fondamentale à sons purs en conduction aérienne et en conduction
osseuse
⎯ Partie 2: Audiométrie en champ acoustique avec des sons purs et des bruits de bande étroite comme
signaux d'essai
⎯ Partie 3: Audiométrie vocale
iv © ISO 2009 – Tous droits réservés
Introduction
L'ISO 8253-1 spécifie les modes opératoires relatifs à la détermination des seuils d'audition à l'aide de sons
purs présentés au sujet par l'intermédiaire d'écouteurs ou d'ossivibrateurs.
La présente partie de l'ISO 8253 spécifie les modes opératoires s'appliquant à la détermination des seuils
d'audition en champ acoustique. En général, les essais en champ acoustique s'effectuent avec écoute
binaurale d'un signal d'essai présenté à l'aide d'un ou de plusieurs haut-parleurs, dans une salle d'essai. Le
signal d'essai peut être un son pur, un son modulé en fréquence ou une bande étroite de bruit. Les
caractéristiques acoustiques du champ sont déterminées par le type de signal d'essai choisi, par le nombre et
les propriétés acoustiques des haut-parleurs utilisés et par les caractéristiques acoustiques de la salle d'essai.
L'audiométrie en champ acoustique peut répondre à des objectifs divers, tels que l'évaluation de l'acuité
auditive de jeunes enfants et la détermination du gain fonctionnel apporté par un appareil de correction
auditive à un sujet particulier.
NORME INTERNATIONALE ISO 8253-2:2009(F)
Acoustique — Méthodes d'essais audiométriques —
Partie 2:
Audiométrie en champ acoustique avec des sons purs et des
bruits à bande étroite comme signaux d'essai
1 Domaine d'application
La présente partie de I'ISO 8253 spécifie les caractéristiques utiles des signaux d'essai, les exigences
relatives aux champs acoustiques libre, diffus et quasi libre, ainsi que les modes opératoires s'appliquant à
l'audiométrie en champ acoustique réalisée à l'aide de sons purs, de sons modulés en fréquence ou d'autres
signaux d'essai de bande étroite émis par un ou plusieurs haut-parleurs. L'objectif principal est la
détermination des niveaux liminaires d'audition dans la gamme de fréquences comprise entre 125 Hz et
8 000 Hz, celle-ci pouvant être étendue entre 20 Hz et 16 000 Hz.
La présente partie de I'ISO 8253 ne comporte pas de spécifications relatives à l'utilisation de haut-parleurs
portatifs. Elle ne couvre pas les essais vocaux.
L'objectif de la présente partie de l'ISO 8253 est de garantir un degré de précision et de reproductibilité des
essais d'audition effectués par audiométrie en champ acoustique aussi élevé que possible.
Des exemples de représentations graphiques des résultats d'essai sont donnés dans l'Annexe A.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence (y compris les éventuels amendements) s'applique.
ISO 226, Acoustique — Lignes isosoniques normales
ISO 266, Acoustique — Fréquences normales
ISO 389-7, Acoustique — Zéro de référence pour l'étalonnage d'équipements audiométriques — Partie 7:
Niveau liminaire de référence dans des conditions d'écoute en champ libre et en champ diffus
1)
ISO 8253-1:— , Acoustique — Méthodes d'essais audiométriques — Partie 1: Audiométrie liminaire
fondamentale à sons purs en conduction aérienne et en conduction osseuse
CEI 60581-7:1986, Équipements et systèmes électroacoustiques haute fidélité — Valeurs limites des
caractéristiques — Partie 7: Haut-parleurs
CEI 60645-1, Électroacoustique — Appareils d'audiologie — Partie 1: Audiomètres tonaux
CEI 61672-1, Électroacoustique — Sonomètres — Partie 1: Spécifications
1) À publier. (Révision de l'ISO 8253-1:1989)
3 Termes et définitions
Pour les besoins de ce document, les termes et définitions suivants s'appliquent
3.1
conduction aérienne
transmission du signal à l'oreille interne, par l'intermédiaire de l'oreille externe et de l'oreille moyenne
3.2
sujet otologiquement normal
personne en bonne santé, ne présentant aucun signe ou symptôme d’affections otologiques, dont le conduit
auditif externe n’est pas obstrué par du cérumen, qui n’a subi antérieurement aucune exposition anormale au
bruit, qui ne prend pas de médicaments potentiellement ototoxiques et qui n’a pas d’antécédents familiaux de
perte auditive
3.3
point de référence
point médian d'une
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.