ISO 19900
(Main)General requirements for offshore structures
- Abstract
This document specifies general provisions for the design and assessment of fixed (bottom-founded) and floating (buoyant) offshore structures. This document contains general provisions for the design of new structures and site assessment of existing structures. This document is applicable for all phases of the life of the structure, including: ¾ pre-service (e.g., fabrication, transportation, installation), ¾ service in-place, both during originally specified design service life and during any life extensions, ¾ functional upgrade, repurpose and reuse, and ¾ decommissioning, and removal. This document focusses on primary and secondary load bearing structure but also provides some provisions for tertiary and ancillary structure. NOTE ISO 24201[22] covers the design of stairs, gratings and handrails. This document was initially created for offshore oil & gas structures but is now also applicable to renewable energy offshore structures. This document does not apply to pipelines, risers or subsea systems.
- Status
- Not Published
- Technical Committee
- ISO/TC 67/SC 7 - Offshore structures
- Drafting Committee
- ISO/TC 67/SC 7/WG 1 - General requirements
- Current Stage
- 6000 - International Standard under publication - 60 Publication
- Start Date
- 11-Nov-2026
Buy Documents
ISO/FDIS 19900 - General requirements for offshore structures
REDLINE ISO/FDIS 19900 - General requirements for offshore structures
ISO/FDIS 19900 - Exigences générales relatives aux structures en mer
ISO 19900, published by ISO, gives the general requirements for the design and assessment of offshore structures and marine systems. It covers fixed bottom-founded and floating buoyant offshore structures across the full life cycle, from fabrication and installation through operation, life extension, repurpose, reuse, decommissioning and removal. The document is written for designers, assessors, operators and other parties who need a common basis for structural safety, integrity management and fitness-for-service decisions.
What does ISO 19900 specify?
ISO 19900 specifies general provisions for new design and for the site assessment of existing offshore structures. It applies to primary and secondary load-bearing structure, and it also gives some provisions for tertiary and ancillary structure.
ISO 19900 is organized into Clauses 1 to 13, followed by Annex A with additional information and guidance. The body covers scope, terms, symbols, design considerations, the basis of structural and geotechnical design, design situations, limit states, actions and resistance, design approaches, the partial factor design method, structural modelling and analysis, and integrity management and assessment of existing structures and marine systems.
The document applies to offshore oil and gas structures and also to lower carbon energy offshore structures. It does not apply to pipelines, risers, cables or subsea systems.
What are the key requirements of ISO 19900?
Design basis, consequence level and life cycle
ISO 19900 requires the functional and operational requirements, including design service life, to be stated in the design basis. That matters in practice because the chosen life, duty cycle and operating philosophy drive the loads, deterioration checks and inspection plan.
Clause 5.2 classifies the structure, or parts of it, into consequence levels L1, L2 or L3. The selected level is used to set the seriousness of failure consequences, so it influences the safety margins, the need for mitigation measures and, in some cases, the design method used.
Clause 5.3 requires robustness so that damage is not disproportionate to the cause, and Clause 5.4 requires durability through design, assessment, inspection, monitoring, maintenance and repair. Clause 5.5 adds sustainability considerations at the design stage, including repurposing, reuse, decommissioning and removal.
Clause 5.6 expects a documented quality management system (QMS) for design, fabrication and installation. For a project team, this means the technical design and the controls around it are both part of the standard’s intent.
Structural and geotechnical basis
Clause 6 sets the basis for structural and geotechnical design. ISO 19900 requires a single datum, consistent units, and the establishment of weights, centres of gravity, marine growth, ice accumulation where relevant, geotechnical and geophysical conditions, and metocean and seismic conditions.
Clause 6 also covers accidental conditions, topsides structures, air gap and splash zone, appurtenances and ancillary systems, inspectability, jack-ups, and lower carbon energy facilities. In practice, this clause tells the project team what site data and configuration data must be fixed early, because changes here can alter the loads, clearances, access and foundation response.
Design situations and limit states
Clause 7 requires all reasonably foreseeable hazards to be identified and the resulting hazardous events to be documented. ISO 19900 then classifies design situations as operational, extreme, abnormal, accidental, short duration and serviceability.
That classification matters because each situation has a different principal action and a different expectation for damage and recovery. Clause 7 also allows damaged conditions in abnormal and accidental situations if structural integrity is maintained long enough for safe evacuation and securing of wells and connecting pipelines, or if the criteria are met for the whole hazardous event.
Clause 8 requires structure performance to be established through limit states. ISO 19900 uses ultimate limit state (ULS), serviceability limit state (SLS) and fatigue limit state (FLS), and it allows alternative performance methods only when they are consistent with the document’s limit-state concept and with the related ISO/TC 67/SC 7 standards.
Actions, resistance and design methods
Clause 9 classifies actions as permanent, variable, environmental or accidental, and it requires repetitive actions to be identified where fatigue damage is possible. It also requires combinations of actions to be considered, which is important because offshore design often depends on how loads act together rather than one load in isolation.
Clause 10 sets the design approach. ISO 19900 uses the semi-probabilistic design approach as the default for new-build verification and assessment of existing structures, but it also permits reliability-based and risk-informed design approaches where allowed. Clause 10 also expects the chosen design method to be public, validated, accessible to engineers and not tied to a commercial entity.
Clause 11 gives the partial factor design method used for the semi-probabilistic approach. It requires design values for actions and resistance to be derived from representative values and calibrated partial factors, and it requires verification for ULS, SLS and FLS. In practical terms, this is the core calculation route for many offshore projects: identify the representative loads and resistance, apply calibrated factors, and check the limit states for each design situation.
Modelling, testing and existing structures
Clause 12 covers structural modelling, structural analysis and design assisted by testing. ISO 19900 allows physical testing both to establish design parameters and to confirm structural performance, especially where calculation models are limited or where hydrodynamic, geotechnical or fatigue information needs support.
Clause 13 sets out integrity management and assessment of existing structures and marine systems. It requires an integrity management system, an integrity management strategy for each facility, use of current as-is data, and inspection, monitoring and surveillance programmes that support fitness-for-service decisions.
For existing structures, Clause 13 requires an assessment when significant deviations or changes are identified or when fitness-for-service cannot be documented with the available information. It also requires the assessment basis, the action and resistance modelling, and the chosen assessment approach to be documented, which is important for life extension, modification and post-damage recovery decisions.
What terms does ISO 19900 define?
- Consequence level - A classification used to set criteria for a structure based on the consequences of failure, with L1, L2 and L3 used in the document.
- Design situation - A set of physical conditions under which the structure or its components are checked against limit states.
- Limit state - The condition beyond which a structure or structural component no longer satisfies the design criteria.
- Representative value - The value used in the semi-probabilistic design approach, based on characteristic values, nominal values or a combination of both.
- Structural integrity - The ability of a structure or structural component to maintain performance throughout the design service life.
- Fit-for-service - The state in which a structure satisfies the applicable structural requirements for the intended use and assessment period.
- Quality management system (QMS) - The documented system used to control design, fabrication and installation activities.
Who uses ISO 19900?
ISO 19900 is used by structural engineers, geotechnical engineers, offshore design teams, integrity managers, operators and project quality managers. It is also relevant to buyers, duty holders and recognized classification societies when they need a common technical basis for design review, certification support or asset assessment.
The standard is used in offshore oil and gas and in lower carbon energy projects, including offshore wind turbine structures and offshore wind substations. It is especially useful for teams handling newbuild design, site-specific assessment, life extension, repurposing, repair, decommissioning and removal.
What changed in ISO 19900 from the previous edition?
ISO 19900 replaces ISO 19900:2019 and was technically revised. The main changes stated in the document are:
- the provisions now apply to all structure types and marine systems, including support structures for wind turbines and associated facilities;
- consequence levels replace exposure levels and are summarized in Table 1;
- design situations are unchanged but are summarized in Table 2;
- Clause 10 now allows reliability-based and risk-informed design approaches in addition to the semi-probabilistic approach, with associated constraints;
- Clause 11 collects the partial factor design method in one place;
- Clause 12 adds more detailed provisions for structural modelling and analysis;
- the normative text was revised to align with IOGP Report 604 guidelines and current ISO directives.
Which standards are used with ISO 19900?
ISO 19900 has no normative references, but it is written to be used with the companion standards named in the document. These are the ones most directly tied to its clauses and examples.
| Standard or group | What it contributes |
|---|---|
| ISO 2394 and ISO 22111 | General principles on reliability and basis-of-design concepts |
| ISO 19901-1 and ISO 19901-2 | Metocean design and operating considerations; seismic design procedures and criteria |
| ISO 19901-3 | Topsides structure, including fire and explosion-related provisions |
| ISO 19901-4, ISO 19901-8 and ISO 19901-10 | Geotechnical design, marine soil investigations and marine geophysical investigations |
| ISO 19901-5, ISO 19901-6, ISO 19901-7 and ISO 19901-9 | Weight management, marine operations, stationkeeping systems and structural integrity management |
| ISO 19902, ISO 19903, ISO 19904-1 and ISO 19905-1 | Structure-type standards and site-specific assessment for fixed steel, concrete, floating and jack-up structures |
| ISO 19906 and ISO 35106 | Arctic offshore structures and Arctic metocean, ice and seabed data |
| ISO 24201 | Tertiary outfitting structures such as stairs, handrails and gratings |
| ISO 29001 and ISO 9001 | Quality management systems |
| ISO 17776 and ISO 31000 | Major accident hazard management and risk management guidance |
| IEC 61400-1, IEC 61400-3-1, IEC 61400-3-2 and IEC 61400-6 | Wind turbine and offshore wind tower/foundation design requirements |
What does the ISO 19900 document contain?
ISO 19900 contains symbols and abbreviated terms, followed by clauses on design considerations, the basis of structural and geotechnical design, design situations, limit states, actions and resistance, design approaches, the partial factor method, structural modelling and analysis, and integrity management of existing structures and marine systems. It also contains Table 1 for consequence levels and Table 2 for design situations.
Clause 12 includes structural modelling, structural analysis and design assisted by testing, so the document is not only about load factors and limit states. Clause 13 gives the process for keeping an asset fit-for-service and for deciding when an assessment is needed.
Annex A provides mirrored guidance for the body clauses, so readers can move between the main requirements and the explanatory material with the same numbering.
Relations
- Effective Date
- 12-Feb-2026
- Revises
ISO 19900:2019 - Petroleum and natural gas industries — General requirements for offshore structures - Effective Date
- 27-Jan-2024
Buy Documents
ISO/FDIS 19900 - General requirements for offshore structures
REDLINE ISO/FDIS 19900 - General requirements for offshore structures
ISO/FDIS 19900 - Exigences générales relatives aux structures en mer
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.
ABS Group Brazil
ABS Group certification services in Brazil.

ABS Quality Evaluations Inc.
American Bureau of Shipping quality certification.
Sponsored listings
Frequently Asked Questions
ISO 19900 is a draft published by the International Organization for Standardization (ISO). Its full title is "General requirements for offshore structures". This standard covers: This document specifies general provisions for the design and assessment of fixed (bottom-founded) and floating (buoyant) offshore structures. This document contains general provisions for the design of new structures and site assessment of existing structures. This document is applicable for all phases of the life of the structure, including: ¾ pre-service (e.g., fabrication, transportation, installation), ¾ service in-place, both during originally specified design service life and during any life extensions, ¾ functional upgrade, repurpose and reuse, and ¾ decommissioning, and removal. This document focusses on primary and secondary load bearing structure but also provides some provisions for tertiary and ancillary structure. NOTE ISO 24201[22] covers the design of stairs, gratings and handrails. This document was initially created for offshore oil & gas structures but is now also applicable to renewable energy offshore structures. This document does not apply to pipelines, risers or subsea systems.
This document specifies general provisions for the design and assessment of fixed (bottom-founded) and floating (buoyant) offshore structures. This document contains general provisions for the design of new structures and site assessment of existing structures. This document is applicable for all phases of the life of the structure, including: ¾ pre-service (e.g., fabrication, transportation, installation), ¾ service in-place, both during originally specified design service life and during any life extensions, ¾ functional upgrade, repurpose and reuse, and ¾ decommissioning, and removal. This document focusses on primary and secondary load bearing structure but also provides some provisions for tertiary and ancillary structure. NOTE ISO 24201[22] covers the design of stairs, gratings and handrails. This document was initially created for offshore oil & gas structures but is now also applicable to renewable energy offshore structures. This document does not apply to pipelines, risers or subsea systems.
ISO 19900 is classified under the following ICS (International Classification for Standards) categories: 75.180.10 - Exploratory, drilling and extraction equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 19900 has the following relationships with other standards: It is inter standard links to FprEN ISO 19900, ISO 19900:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 19900 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 abnormal environmental event
- 3.2 accidental event
- 3.3 action
- 3.4 action effect
- 3.5 air gap
- 3.6 appurtenance
- 3.7 ancillary system
- 3.8 basic variable
- 3.9 calibration
- 3.10 characteristic value
- 3.11 conductor
- 3.12 consequence level
- 3.13 damage state
- 3.14 decommissioning
- 3.15 design approach
- 3.16 design criteria
- 3.17 design method
- 3.18 design service life
- 3.19 design situation
- 3.20 design value
- 3.21 deterioration
- 3.22 ductility
- 3.23 ductility
- 3.24 ductility
- 3.25 durability
- 3.26 extreme environmental event
- 3.27 facility
- 3.28 fit-for-service
- 3.29 fixed structure
- 3.30 floating structure
- 3.31 hazard
- 3.32 hazardous event
- 3.33 ice gouge
- 3.34 incident
- 3.35 inspection
- 3.36 integrity management
- 3.37 jack-up
- 3.38 limit state
- 3.39 maintenance
- 3.40 marine system
- 3.41 marine system integrity
- 3.42 nominal value
- 3.43 offshore
- 3.44 offshore wind farm
- 3.45 offshore wind structure
- 3.46 offshore wind substation
- 3.47 offshore wind turbine structure
- 3.48 operator
- 3.49 partial factor method
- 3.50 performance
- 3.51 primary structure
- 3.52 recognized classification society
- 3.53 reliability
- 3.54 reliability-based design approach
- 3.55 repair
- 3.56 representative value
- 3.57 resistance
- 3.58 return period
- 3.59 riser
- 3.60 risk-informed design approach
- 3.61 robustness
- 3.62 scour
- 3.63 sea floor
- 3.64 seabed
- 3.65 secondary structure
- 3.66 semi-probabilistic design approach
- 3.67 splash zone
- 3.68 structural component
- 3.69 structural integrity
- 3.70 structural reliability analysis
- 3.71 structure
- 3.72 tertiary structure
- 3.73 topsides
- 4 Symbols and abbreviated terms
- 4.1 Symbols
- 4.2 Abbreviated terms
Introduction
The International Standards for offshore structures developed by ISO TC 67/SC 7 comprise:
- ISO 19900, the unifying International Standard for offshore structures; - the ISO 19901 series, providing specific requirements for offshore structures. - ISO 19902, ISO 19903,ISO 19904,ISO 19905 series and ISO 19906, structure-type standards. Figure 1 illustrates the relationships between the International Standards for offshore structures developed by ISO/TC 67/SC 7.
Figure 1 — Relationship of International Standards for offshore structures developed by ISO/TC 67/SC 7 The International Standards for offshore structures developed by ISO/TC 67/SC 7 follow the principles of ISO 2394 and ISO 22111 and constitutes a common basis for addressing design and assessment of offshore structures used by the energy industries worldwide. Additional information and guidance are given in Annex A, where the clause numbering mirrors the clauses in the body of this document to facilitate crossreferencing. Statements containing requirements (“shall” and “shall not”), recommendations (“should” and “should not”) or permissions (“may”) are collectively referred to as provisions.
FINAL DRAFT International Standard ISO/FDIS 19900:2026(en) General requirements for offshore structures
1 Scope
This document contains general requirements for design of structures and marine systems and for structural integrity management. It covers both fixed (bottom-founded) and floating (buoyant) offshore structures. This document is applicable for all phases of the life of the structure, including:
- pre-service (e.g. fabrication, transportation, installation);
- service in-place, both during originally specified design service life and during any life extensions;
- functional upgrade, repurpose and reuse;
- decommissioning and removal.
This document focuses on primary and secondary load bearing structure but also includes some provisions for tertiary and ancillary structure.
This document is applicable to offshore oil and gas structures, as well as lower carbon energy offshore structures.
This document does not apply to pipelines, risers, cables or subsea systems.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 abnormal environmental event
environmental hazardous event (3.32) having a low probability of occurrence during the design service life (3.18) Note 1 to entry: The probability of occurrence selected for highest consequence level (3.12) is typically within the −3 −4 range 10 per annum (1 in 1 000 years) to 10 per annum (1 in 10 000 years). Note 2 to entry: Abnormal environmental events are associated with abnormal design situations (3.19), see 7.2.
3.2 accidental event
non-environmental hazardous event (3.32) having a low probability of occurrence during the design service life (3.18) Note 1 to entry: The probability of occurrence selected for highest consequence level (3.12) is typically within the −3 −4 range 10 per annum (1 in 1 000 years) to 10 per annum (1 in 10 000 years).
ISO/FDIS 19900:2026(en) Note 2 to entry: Accidental events are associated with a substantial release of energy, such as vessel collisions, fires and explosions.
Note 3 to entry: Accidental events are associated with accidental design situations (3.19), see 7.2. Lesser accidents that can be expected during the life of the structure (3.71), such as dropped objects and low-energy vessel impact, are termed incidents (3.34) and are addressed under operational design situations (3.19).
3.3 action
external load applied to the structure (3.71) (direct load) or imposed deformation or acceleration (indirect load) EXAMPLE An imposed deformation can be caused by enforcing fabrication tolerances, differential settlement, temperature change or moisture variation. An imposed acceleration can be caused by an earthquake. Note 1 to entry: Individual action types are categorised in Clause 9.
3.4 action effect
result of actions (3.3) on a structural component (3.68), e.g. internal force, moment, stress, strain, or on the structure (3.71), e.g. deflection, rotation
3.5 air gap
distance between the highest water surface elevation and the lowest exposed part of the deck primary structure (3.51) not designed to withstand associated environmental action effects (3.4) for a specified return period (3.58) Note 1 to entry: This definition can be refined for different facility (3.27) types in their respective standards.
3.6 appurtenance
accessory or attachment to the structure (3.71) which typically assists installation, provides access or protection, or carries fluids or gas EXAMPLE Caisson, anodes, boat landing, fender and protection frames. Note 1 to entry: Appurtenances do not normally contribute to the stiffness of the structure (3.71) but can attract significant environmental loading.
3.7 ancillary system
system not under responsibility of the structural discipline or a group of appurtenances (3.6), attached to or within the structure (3.71) EXAMPLE Risers (3.59), subsea systems, cables, umbilicals.
3.8 basic variable
variable representing physical quantities which characterize actions (3.3) and environmental influences, geometric quantities, and material properties including soil properties Note 1 to entry: Basic variables are typically random variables or random processes used in the calculation or assessment of representative values (3.56) of actions (3.3) or resistance (3.57).
3.9 calibration
process used to specify acceptance criteria for different design approaches (3.15) Note 1 to entry: Code calibration for the partial factor method (3.49), partial factor and annual probabilities associated with representative values (3.56) are based on experience, known cases or reliability targets. For other methods in the semi-probabilistic design approach (3.66), this can involve the selection of safety factors.
ISO/FDIS 19900:2026(en) Note 2 to entry: For methods in the reliability-based design approach (3.54), a reliability target can be calibrated to proven safe cases or to risk indices.
3.10 characteristic value
value assigned to a basic variable (3.8) with a prescribed probability of exceedance Note 1 to entry: A basic variable (3.8) can have two or more characteristic values, e.g. an upper value and a lower value.
3.11 conductor
tubular pipe set into the ground to provide the initial stable structural foundation for setting the surface casing and protecting the internal well string from metocean actions (3.3) Note 1 to entry: The conductor provides lateral and, in some cases, axial support, enables circulation of drilling fluid, and guides the drill string to facilitate setting of the surface casing.
3.12 consequence level
classification system used to establish relevant criteria for a structure (3.71) based on consequences of failure
3.13 damage state
discrete state that describes the level of impairment Note 1 to entry: Damage states can be categorized between no damage and complete loss of a structure (3.71) or a marine system (3.40).
3.14 decommissioning
process of shutting down a facility (3.27) enabling preparations for cleaning, dismantling and removal from location at, or after, the end of its design service life (3.18)
3.15 design approach
framework used to ensure acceptable structure (3.71) performance Note 1 to entry: Design approaches are categorized as semi-probabilistic (3.66), reliability-based (3.54) and riskinformed (3.60). Note 2 to entry: Different design approaches can be applied for different design situations (3.19). Note 3 to entry: Acceptable structure (3.71) performance is achieved by satisfying limit state (3.38) criteria. Note 4 to entry: Different design methods (3.17) can be applied within a design approach.
3.16 design criteria
quantitative formulations using design values (3.20) describing the conditions to be fulfilled for each design situation (3.19)
3.17 design method
proven procedure, categorized within a design approach (3.15), used to demonstrate the safety of a structure (3.71) Note 1 to entry: Safety can involve limit state (3.38) verification, or account for relevant consequences and uncertainties.
ISO/FDIS 19900:2026(en)
3.18 design service life
design life life planned period for which a structure (3.71) is used for its intended purpose with anticipated maintenance (3.39), but without substantial repair (3.55) being necessary Note 1 to entry: The originally specified design service life can be updated during the operating phase to include any life extension periods until removal of the facility (3.27).
3.19 design situation
set of physical conditions for which the structure (3.71) or its components are subject to limit state (3.38) verification Note 1 to entry: Six design situations are categorised in Table 2: operational, extreme, abnormal, accidental, short duration and serviceability.
3.20 design value
value derived from the representative value (3.56) for use in the semi-probabilistic design approach (3.66) Note 1 to entry: Design values can be different according to the different design situations (3.19) and associated safety partial factors.
Note 2 to entry: Design value for resistance is calculated by dividing its representative value (3.56) by a partial factor for resistance (3.57), while design value (3.20)action effect (3.4) is calculated by multiplying its representative value (3.56) by a partial factor for action (3.3) or action effect (3.4).
3.21 deterioration
process that adversely affects structural integrity (3.69) over time Note 1 to entry: Deterioration can be caused by naturally occurring chemical, physical, or biological processes including corrosion, by environmental actions (3.3), by incidents (3.34) and accidental actions (3.3), by fatigue, wear, abrasion, and by improper operation and maintenance (3.39) of the structure (3.71).
3.22 ductility
<material> ability of a material to deform and absorb energy beyond its elastic limit
3.23 ductility
<structural component> ability of a structural component (3.68) to sustain action effects (3.4) beyond yield
3.24 ductility
<structural system> ability of a structural system to deform and dissipate energy, and to redistribute action effects (3.4)
3.25 durability
ability of a structure (3.71) or structural component (3.68) to maintain its function throughout its design service life (3.18)
3.26 extreme environmental event
−2 environmental hazardous event (3.32) typically having probability of occurrence of 10 per annum (1 in 100 years) for highest consequence level (3.12) Note 1 to entry: Extreme environmental events are associated with extreme design situations (3.19), see 7.2.
ISO/FDIS 19900:2026(en) −2 Note 2 to entry: For offshore wind structures (3.45) and jack-ups (3.37) a probability of occurrence of 2 x 10 per annum (1 in 50 years) is typically applied.
3.27 facility
constructions, pieces of equipment, and services that are provided for the offshore (3.43) energy sector Note 1 to entry: The facility includes the structure (3.71) and non-structural systems such as topsides (3.73) equipment, marine systems (3.40), piping and accommodation.
Note 2 to entry: A hydrocarbon facility (platform) includes structural appurtenances (3.6) and ancillary systems (3.7) but does not include the non-structural components (3.68) of the hydrocarbon wells. Note 3 to entry: The facility does not include the geological strata supporting the foundation. However, site-specific geotechnical parameters provide the boundary conditions necessary to model the facility’s foundation or anchoring.
3.28 fit-for-service
in compliance with the applicable structural requirements Note 1 to entry: Compliance with this standard indicates that the structure (3.71) provides the required level of structural safety, functionality, and integrity for the defined design and operating conditions and assessment period. Note 2 to entry: Risk-informed design approach (3.60) or reliability-based design approach (3.54) can be used to demonstrate compliance, where permitted, see 10.3.
3.29 fixed structure
structure (3.71) that is bottom-founded and transfers most of the actions (3.3) on it to the seabed (3.64)
3.30 floating structure
structure (3.71) where the full weight is supported by buoyancy
3.31 hazard
potential source of harm Note 1 to entry: Harm is typically differentiated between harm to people, harm to the environment, harm in terms of costs to organizations, or harm to society in general.
3.32 hazardous event
event which occurs when a hazard (3.31) interacts with a structure (3.71) EXAMPLE Wave impacting the structure (3.71), iceberg impacting the structure (3.71), excessive topsides (3.73) weight added to the structure (3.71), vessel collision, fire, explosion, and landslip in the vicinity of structural anchors (piles).
Note 1 to entry: A hazardous event can be a storm involving waves, currents and winds acting from different directions. Note 2 to entry: A hazardous event can be a combination of basic variables (3.8) such as wave height and period, or ice floe size and drift speed.
Note 3 to entry: A hazardous event can be an action (3.3) associated with a hazard (3.31) that involves various combinations of basic variables (3.8).
3.33 ice gouge
ice scour incision in the seabed (3.64) or removal of seabed (3.64) material by an ice feature
ISO/FDIS 19900:2026(en)
3.34 incident
non-environmental hazardous event (3.32) considered in an operational design situation (3.19) Note 1 to entry: An incident is a lesser accidental event (3.2), associated with possible local damage or damage to structural components (3.68), occurring with low probability, most typically associated with probabilities not less −2 than 10 per annum (1 in 100 years).
3.35 inspection
on-site examination within the scope of quality control and condition assessment aiming to assess the present condition of a structure (3.71)
3.36 integrity management
systematic process intended to assure integrity of a structure (3.71) or a marine system (3.40)
3.37 jack-up
mobile offshore (3.43) unit with a buoyant hull and one or more legs that can be moved up and down relative to the hull Note 1 to entry: A jack-up reaches its operational mode by lowering the leg(s) to the seabed (3.64) and then raising the hull to the required elevation. The majority of jack-ups have three or more legs, each of which can be moved independently and which are supported in the seabed (3.64) by spudcans.
3.38 limit state
state beyond which the structure (3.71) or structural component (3.68) no longer satisfies the design criteria (3.16) Note 1 to entry: Three limit states are categorised in Clause 8: ultimate, serviceability and fatigue.
3.39 maintenance
routine work undertaken to ensure the continuing performance of a facility (3.27)
3.40 marine system
system contributing to the structural safety, stability and position keeping ability of a floating facility (3.27)
3.41 marine system integrity
ability of a marine system (3.40) to maintain performance (3.50) throughout the design service life (3.18), with respect to structural safety, robustness (3.61), serviceability and durability (3.25)
3.42 nominal value
value assigned to a basic variable (3.8) on a non-statistical basis, either determined from acquired experience or physical conditions, or as specified in a published code or standard
3.43 offshore
situated in water some distance from the shore Note 1 to entry: Alternatively, "near-shore" or “coastal” can be used to specify locations next to the coast or in mouths of rivers.
3.44 offshore wind farm
group of offshore wind turbine structures (3.47) and offshore wind substations (3.46) in the same location
ISO/FDIS 19900:2026(en)
3.45 offshore wind structure
part of an offshore wind turbine facility (3.27) which extends upwards from the seabed (3.64) and connects the foundation to the wind turbine tower, or part of an offshore wind substation (3.46) that supports the topsides (3.73) Note 1 to entry: The offshore wind structure can include a transition piece.
3.46 offshore wind substation
an electrical facility that collects and manages the power generated by wind turbines before transmitting it to shore.
3.47 offshore wind turbine structure
support structure for a wind turbine assembly that is used to convert kinetic energy from the wind into electricity
3.48 operator
owner duty holder principal company or company representative leasing the offshore (3.43) site from a government
3.49 partial factor method
method within the semi-probabilistic design approach (3.66) where a safety coefficient (partial factor) is applied to basic variables (3.8) to ensure structural reliability (3.53) Note 1 to entry: Partial factors can be applied to actions (3.3), resistances (3.57) and materials, see 11.4 and 11.5.
3.50 performance
ability of a structure (3.71) or a structural component (3.68) to fulfil specified requirements Note 1 to entry: Specified requirements include requirements for structural functionality, structural integrity (3.69) and functionality of marine systems (3.40).
Note 2 to entry: Performance levels are established as a means of mitigating consequences associated with life-safety, environmental pollution, reliability (3.53) of energy supply and business disruption.
3.51 primary structure
all main structural components (3.68) that provide the structure's (3.71) main strength and stiffness
3.52 recognized classification society
RCS member of the international association of classification societies (IACS), with recognized and relevant competence and experience in offshore (3.43)structures (3.71) and with established rules and procedures for classification and certification of offshore (3.43)structures (3.71) located at a specific site
3.53 reliability
performance (3.50) over a specified time period Note 1 to entry: When reliability is used in the context of limit states (3.38), it can be expressed as the probability that the limit is not exceeded.
Note 2 to entry: The specified time period is typically one year.
ISO/FDIS 19900:2026(en)
3.54 reliability-based design approach
design approach (3.15) where uncertainty and variability in the basic variables (3.8) are represented by means of probabilistic methods and models Note 1 to entry: This approach is based on probabilistic models of action effects and resistances, e.g. FORM, SORM, Monte-Carlo simulations, or hazard and fragility curves.
3.55 repair
restoring the condition of a structure (3.71) that has been damaged or deteriorated
3.56 representative value
value used in the semi-probabilistic design approach (3.66) based on the characteristic value (3.10) or the nominal value (3.42) or a combination of characteristic values (3.10) and nominal values (3.42) Note 1 to entry: For strength models, a representative value can be either a characteristic value (3.10) or a nominal value (3.42) while for action models, a representative value can usually be calculated from a combination of characteristic values (3.10) and nominal values (3.42).
3.57 resistance
ability of a structure (3.71), or a structural component (3.68), to withstand action effects (3.4)
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols and abbreviated terms
- 4.1 Symbols
- 4.2 Abbreviated terms
- 5 Design considerations
- 5.1 Functional and operational requirements
- 5.2 Consequence levels
- 5.3 Robustness
- 5.4 Durability
- 5.5 Sustainability
- 5.6 Quality management
- 6 Basis of structural and geotechnical design
- 6.1 Facility location and orientation
- 6.2 Weights
- 6.3 Geotechnical and geophysical conditions
- 6.4 Environmental conditions
- 6.5 Accidental conditions
- 6.6 Topsides structures, air gap and splash zone
- 6.7 Appurtenances and ancillary systems
- 6.8 Inspectability
- 6.9 Jack-ups
- 6.10 Lower carbon energy facilities
- 7 Development of design situations
- 7.1 Hazardous events
- 7.2 Design situations
- 8 Limit states and structure performance
- 8.1 General
- 8.2 Ultimate limit states
- 8.3 Serviceability limit states
- 8.4 Fatigue limit states
- 8.5 Alternative methods for demonstrating structure performance
- 9 Characterization of actions and resistance
- 9.1 Basic variables
- 9.2 Classification of actions
- 9.3 Permanent actions
- 9.4 Variable actions
- 9.5 Environmental actions
- 9.6 Accidental actions
- 9.7 Repetitive actions
- 9.8 Actions acting in combination
- 9.9 Resistance
- 10 Design approaches
- 10.1 Design approaches for offshore structures
- 10.2 Semi-probabilistic design approach
- 10.3 Alternative design approaches
- 11 Partial factor design method
- 11.1 Basis for partial factor design method
- 11.2 Hazardous events
- 11.3 Representative values
- 11.4 Actions
- 11.5 Resistance
- 11.6 Verification by the partial factor design method
- 12 Structural modelling and analysis
- 12.1 Structural modelling
- 12.2 Structural analysis
- 12.3 Design assisted by testing
- 13 Integrity management and assessment of existing structures and marine systems
- 13.1 General
- 13.2 Integrity management of structures and marine systems
- 13.3 Assessment of existing structures and marine systems
- Annex A
- Bibliography
Introduction
The International Standards for offshore structures developed by ISO TC 67/SC 7 comprise:
- — ISO 19900, the unifying International Standard for offshore structures; [6] – [15] - — the ISO 19901 series ,, providing specific requirements for offshore structures. [16] [17] [18] [19]–[22] [23] - — ISO 19902 , , ISO 19903 , ,ISO 19904 , ,ISO 19905 series and ISO 19906 ,, structuretype standards. Figure 1Figure 1 illustrates the relationships between the International Standards for offshore structures developed by ISO/TC 67/SC 7.
ISO/FDIS 19900:2026(en)
Figure 1 — Relationship of International Standards for offshore structures developed by ISO/TC 67/SC 7 The International Standards for offshore structures developed by ISO/TC 67/SC 7 follow the principles of ISO [1] [24] 2394 and ISO 22111 and constitutes a common basis for addressing design and assessment of offshore structures used by the energy industries worldwide. Additional information and guidance are given in Annex AAnnex A,, where the clause numbering mirrors the clauses in the body of this document to facilitate cross-referencing.
Statements containing requirements (“shall” and “shall not”), recommendations (“should” and “should not”) or permissions (“may”) are collectively referred to as provisions.
ISO/FDIS 19900:2026(en) General requirements for offshore structures
1 Scope
This document contains general requirements for design of structures and marine systems and for structural integrity management. It covers both fixed (bottom-founded) and floating (buoyant) offshore structures. This document is applicable for all phases of the life of the structure, including:
- — pre-service (e.g. fabrication, transportation, installation);
- — service in-place, both during originally specified design service life and during any life extensions;
- — functional upgrade, repurpose and reuse;
- — decommissioning and removal.
This document focuses on primary and secondary load bearing structure but also includes some provisions for tertiary and ancillary structure.
This document is applicable to offshore oil and gas structures, as well as lower carbon energy offshore structures.
This document does not apply to pipelines, risers, cables or subsea systems.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- — ISO Online browsing platform: available at https://www.iso.org/obp
- — IEC Electropedia: available at https://www.electropedia.org/ 3.1 3.1 abnormal environmental event environmental hazardous event (3.32(3.32)) having a low probability of occurrence during the design service life (3.18(3.18)) Note 1 to entry: The probability of occurrence selected for highest consequence level (3.12(3.12)) is typically within the −3 −4 range 10 per annum (1 in 1 000 years) to 10 per annum (1 in 10 000 years). Note 2 to entry: Abnormal environmental events are associated with abnormal design situations (3.19(3.19),), see 7.27.2.. 3.2 3.2 accidental event non-environmental hazardous event (3.32(3.32)) having a low probability of occurrence during the design service life (3.18(3.18))
ISO/FDIS 19900:2026(en) Note 1 to entry: The probability of occurrence selected for highest consequence level (3.12(3.12) ) is typically within the −3 −4 range 10 per annum (1 in 1 000 years) to 10 per annum (1 in 10 000 years). Note 2 to entry: Accidental events are associated with a substantial release of energy, such as vessel collisions, fires and explosions.
Note 3 to entry: Accidental events are associated with accidental design situations (3.19(3.19),), see 7.27.2.. Lesser accidents that can be expected during the life of the structure (3.71(3.71),), such as dropped objects and low-energy vessel impact, are termed incidents (3.34(3.34)) and are addressed under operational design situations (3.19(3.19).). 3.3 3.3 action external load applied to the structure (3.71(3.71)) (direct load) or imposed deformation or acceleration (indirect load) EXAMPLE An imposed deformation can be caused by enforcing fabrication tolerances, differential settlement, temperature change or moisture variation. An imposed acceleration can be caused by an earthquake. Note 1 to entry: Individual action types are categorised in Clause 9Clause 9.. 3.4 3.4 action effect result of actions (3.3(3.3)) on a structural component (3.68(3.68),), e.g. internal force, moment, stress, strain, or on the structure (3.71(3.71),), e.g. deflection, rotation 3.5 3.5 air gap distance between the highest water surface elevation and the lowest exposed part of the deck primary structure (3.51(3.51)) not designed to withstand associated environmental action effects (3.4(3.4)) for a specified return period (3.58(3.58)) Note 1 to entry: This definition can be refined for different facility (3.27(3.27)) types in their respective standards. 3.6 3.6 appurtenance accessory or attachment to the structure (3.71(3.71)) which typically assists installation, provides access or protection, or carries fluids or gas EXAMPLESEXAMPLE Caisson, anodes, boat landing, fender and protection frames. Note 1 to entry: Appurtenances do not normally contribute to the stiffness of the structure (3.71(3.71)) but can attract significant environmental loading.
3.7 3.7 ancillary system system not under responsibility of the structural discipline or a group of appurtenances (3.6(3.6),), attached to or within the structure (3.71(3.71)) EXAMPLESEXAMPLE Risers (3.59(3.59),), subsea systems, cables, umbilicals. 3.8 3.8 basic variable variable representing physical quantities which characterize actions (3.3(3.3)) and environmental influences, geometric quantities, and material properties including soil properties Note 1 to entry: Basic variables are typically random variables or random processes used in the calculation or assessment of representative values (3.56(3.56)) of actions (3.3(3.3)) or resistance (3.57(3.57).).
ISO/FDIS 19900:2026(en) 3.9 3.9 calibration process used to specify acceptance criteria for different design approaches (3.15(3.15)) Note 1 to entry: Code calibration for the partial factor method (3.49(3.49),), partial factor and annual probabilities associated with representative values (3.56(3.56)) are based on experience, known cases or reliability targets. For other methods in the semi-probabilistic design approach (3.66(3.66),), this can involve the selection of safety factors. Note 2 to entry: For methods in the reliability-based design approach (3.54(3.54),), a reliability target can be calibrated to proven safe cases or to risk indices.
3.10 3.10 characteristic value value assigned to a basic variable (3.8(3.8)) with a prescribed probability of exceedance Note 1 to entry: A basic variable (3.8(3.8)) can have two or more characteristic values, e.g. an upper value and a lower value.
3.11 3.11 conductor tubular pipe set into the ground to provide the initial stable structural foundation for setting the surface casing and protecting the internal well string from metocean actions (3.3(3.3)) Note 1 to entry: The conductor provides lateral and, in some cases, axial support, enables circulation of drilling fluid, and guides the drill string to facilitate setting of the surface casing. 3.12 3.12 consequence level classification system used to establish relevant criteria for a structure (3.71(3.71)) based on consequences of failure 3.13 3.13 damage state discrete state that describes the level of impairment Note 1 to entry: Damage states can be categorized between no damage and complete loss of a structure (3.71(3.71)) or a marine system (3.40(3.40).).
3.14 3.14 decommissioning process of shutting down a facility (3.27(3.27)) enabling preparations for cleaning, dismantling and removal from location at, or after, the end of its design service life (3.18(3.18)) 3.15 3.15 design approach framework used to ensure acceptable structure (3.71(3.71)) performance Note 1 to entry: Design approaches are categorized as semi-probabilistic (3.66(3.66),), reliability-based (3.54(3.54)) and risk-informed (3.60(3.60).).
Note 2 to entry: Different design approaches can be applied for different design situations (3.19(3.19).). Note 3 to entry: Acceptable structure (3.71(3.71)) performance is achieved by satisfying limit state (3.38(3.38)) criteria. Note 4 to entry: Different design methods (3.17(3.17)) can be applied within a design approach.
ISO/FDIS 19900:2026(en) 3.16 3.16 design criteria quantitative formulations using design values (3.20(3.20)) describing the conditions to be fulfilled for each design situation (3.19(3.19)) 3.17 3.17 design method proven procedure, categorized within a design approach (3.15(3.15),), used to demonstrate the safety of a structure (3.71(3.71)) Note 1 to entry: Safety can involve limit state (3.38(3.38)) verification, or account for relevant consequences and uncertainties.
3.18 3.18 design service life design life life planned period for which a structure (3.71(3.71)) is used for its intended purpose with anticipated maintenance (3.39(3.39),), but without substantial repair (3.55(3.55)) being necessary Note 1 to entry: The originally specified design service life can be updated during the operating phase to include any life extension periods until removal of the facility (3.27(3.27).). 3.19 3.19 design situation set of physical conditions for which the structure (3.71(3.71)) or its components are subject to limit state (3.38(3.38)) verification Note 1 to entry: Six design situations are categorised in Table 2Table 2:: operational, extreme, abnormal, accidental, short duration and serviceability.
3.20 3.20 design value value derived from the representative value (3.56(3.56)) for use in the semi-probabilistic design approach (3.66(3.66)) Note 1 to entry: Design values can be different according to the different design situations (3.19(3.19)) and associated safety partial factors.
Note 2 to entry: Design value for resistance is calculated by dividing its representative value (3.56(3.56)) by a partial factor for resistance (3.57(3.57),), while design value (3.20(3.20) )action effect (3.4(3.4)) is calculated by multiplying its representative value (3.56(3.56)) by a partial factor for action (3.3(3.3)) or action effect (3.4(3.4).). 3.21 3.21 deterioration process that adversely affects structural integrity (3.69(3.69)) over time Note 1 to entry: Deterioration can be caused by naturally occurring chemical, physical, or biological processes including corrosion, by environmental actions (3.3(3.3),), by incidents (3.34(3.34)) and accidental actions (3.3(3.3),), by fatigue, wear, abrasion, and by improper operation and maintenance (3.39(3.39)) of the structure (3.71(3.71).). 3.22 3.22 ductility <material> ability of a material to deform and absorb energy beyond its elastic limit
ISO/FDIS 19900:2026(en) 3.23 3.23 ductility <structural component> ability of a structural component (3.68(3.68)) to sustain action effects (3.4(3.4)) beyond yield 3.24 3.24 ductility <structural system> ability of a structural system to deform and dissipate energy, and to redistribute action effects (3.4(3.4)) 3.25 3.25 durability ability of a structure (3.71(3.71)) or structural component (3.68(3.68)) to maintain its function throughout its design service life (3.18(3.18)) 3.26 3.26 extreme environmental event −2 environmental hazardous event (3.32(3.32)) typically having probability of occurrence of 10 per annum (1 in 100 years) for highest consequence level (3.12(3.12)) Note 1 to entry: Extreme environmental events are associated with extreme design situations (3.19(3.19),), see 7.27.2.. −2 Note 2 to entry: For offshore wind structures (3.45(3.45)) and jack-ups (3.37(3.37)) a probability of occurrence of 2 x 10 per annum (1 in 50 years) is typically applied.
3.27 3.27 facility constructions, pieces of equipment, and services that are provided for the offshore (3.43(3.43)) energy sector Note 1 to entry: The facility includes the structure (3.71(3.71)) and non-structural systems such as topsides (3.73(3.73)) equipment, marine systems (3.40(3.40),), piping and accommodation. Note 2 to entry: A hydrocarbon facility (platform) includes structural appurtenances (3.6(3.6)) and ancillary systems (3.7(3.7)) but does not include the non-structural components (3.68(3.68)) of the hydrocarbon wells. Note 3 to entry: The facility does not include the geological strata supporting the foundation. However, site-specific geotechnical parameters provide the boundary conditions necessary to model the facility’s foundation or anchoring. 3.28 3.28 fit-for-service in compliance with the applicable structural requirements Note 1 to entry: Compliance with this standard indicates that the structure (3.71(3.71)) provides the required level of structural safety, functionality, and integrity for the defined design and operating conditions and assessment period. Note 2 to entry: Risk-informed design approach (3.60(3.60)) or reliability-based design approach (3.54(3.54)) can be used to demonstrate compliance, where permitted, see 10.310.3..
3.29 3.29 fixed structure structure (3.71(3.71)) that is bottom-founded and transfers most of the actions (3.3(3.3)) on it to the seabed (3.64(3.64)) 3.30 3.30 floating structure structure (3.71(3.71)) where the full weight is supported by buoyancy
ISO/FDIS 19900:2026(en) 3.31 3.31 hazard potential source of harm Note 1 to entry: Harm is typically differentiated between harm to people, harm to the environment, harm in terms of costs to organizations, or harm to society in general.
3.32 3.32 hazardous event event which occurs when a hazard (3.31(3.31)) interacts with a structure (3.71(3.71)) EXAMPLESEXAMPLE Wave impacting the structure (3.71(3.71),), iceberg impacting the structure (3.71(3.71),), excessive topsides (3.73(3.73)) weight added to the structure (3.71(3.71),), vessel collision, fire, explosion, and landslip in the vicinity of structural anchors (piles).
Note 1 to entry: A hazardous event can be a storm involving waves, currents and winds acting from different directions. Note 2 to entry: A hazardous event can be a combination of basic variables (3.8(3.8)) such as wave height and period, or ice floe size and drift speed.
Note 3 to entry: A hazardous event can be an action (3.3(3.3)) associated with a hazard (3.31(3.31)) that involves various combinations of basic variables (3.8(3.8).).
3.33 3.33 ice gouge ice scour incision in the seabed (3.64(3.64)) or removal of seabed (3.64(3.64)) material by an ice feature 3.34 3.34 incident non-environmental hazardous event (3.32(3.32)) considered in an operational design situation (3.19(3.19)) Note 1 to entry: An incident is a lesser accidental event (3.2(3.2),), associated with possible local damage or damage to structural components (3.68(3.68),), occurring with low probability, most typically associated with probabilities not less −2 than 10 per annum (1 in 100 years).
3.35 3.35 inspection on-site examination within the scope of quality control and condition assessment aiming to assess the present condition of a structure (3.71(3.71)) 3.36 3.36 integrity management systematic process intended to assure integrity of a structure (3.71(3.71)) or a marine system (3.40(3.40)) 3.37 3.37 jack-up mobile offshore (3.43(3.43)) unit with a buoyant hull and one or more legs that can be moved up and down relative to the hull Note 1 to entry: A jack-up reaches its operational mode by lowering the leg(s) to the seabed (3.64(3.64)) and then raising the hull to the required elevation. The majority of jack-ups have three or more legs, each of which can be moved independently and which are supported in the seabed (3.64(3.64)) by spudcans.
ISO/FDIS 19900:2026(en) 3.38 3.38 limit state state beyond which the structure (3.71(3.71)) or structural component (3.68(3.68)) no longer satisfies the design criteria (3.16(3.16)) Note 1 to entry: Three limit states are categorised in Clause 8Clause 8:: ultimate, serviceability and fatigue. 3.39 3.39 maintenance routine work undertaken to ensure the continuing performance of a facility (3.27(3.27)) 3.40 3.40 marine system system contributing to the structural safety, stability and position keeping ability of a floating facility (3.27(3.27)) 3.41 3.41 marine system integrity ability of a marine system (3.40(3.40)) to maintain performance (3.50(3.50)) throughout the design service life (3.18(3.18),), with respect to structural safety, robustness (3.61(3.61),), serviceability and durability (3.25(3.25)) 3.42 3.42 nominal value value assigned to a basic variable (3.8(3.8)) on a non-statistical basis, either determined from acquired experience or physical conditions, or as specified in a published code or standard 3.43 3.43 offshore situated in water some distance from the shore Note 1 to entry: Alternatively, "near-shore" or “coastal” can be used to specify locations next to the coast or in mouths of rivers.
3.44 3.44 offshore wind farm group of offshore wind turbine structures (3.47(3.47)) and offshore wind substations (3.46(3.46)) in the same location 3.45 3.45 offshore wind structure part of an offshore wind turbine facility (3.27(3.27)) which extends upwards from the seabed (3.64(3.64)) and connects the foundation to the wind turbine tower, or part of an offshore wind substation (3.46(3.46)) that supports the topsides (3.73(3.73)) Note 1 to entry: The offshore wind structure can include a transition piece. 3.46 3.46 offshore wind substation an electrical facility that collects and manages the power generated by wind turbines before transmitting it to shore.
3.47 3.47 offshore wind turbine structure support structure for a wind turbine assembly that is used to convert kinetic energy from the wind into electricity
ISO/FDIS 19900:2026(en) 3.48 3.48 operator owner duty holder principal company or company representative leasing the offshore (3.43(3.43)) site from a government 3.49 3.49 partial factor method method within the semi-probabilistic design approach (3.66(3.66)) where a safety coefficient (partial factor) is applied to basic variables (3.8(3.8)) to ensure structural reliability (3.53(3.53)) Note 1 to entry: Partial factors can be applied to actions (3.3(3.3),), resistances (3.57(3.57)) and materials, see 11.411.4 and 11.511.5..
3.50 3.50 performance ability of a structure (3.71(3.71)) or a structural component (3.68(3.68)) to fulfil specified requirements Note 1 to entry: Specified requirements include requirements for structural functionality, structural integrity (3.69(3.69)) and functionality of marine systems (3.40(3.40).). Note 2 to entry: Performance levels are established as a means of mitigating consequences associated with life-safety, environmental pollution, reliability (3.53(3.53)) of energy supply and business disruption. 3.51 3.51 primary structure all main structural components (3.68(3.68)) that provide the structure's (3.71(3.71)) main strength and stiffness 3.52 3.52 recognized classification society RCS member of the international association of classification societies (IACS), with recognized and relevant competence and experience in offshore (3.43(3.43) )structures (3.71(3.71)) and with established rules and procedures for classification and certification of offshore (3.43(3.43) )structures (3.71(3.71)) located at a specific site 3.53 3.53 reliability performance (3.50(3.50)) over a specified time period Note 1 to entry: When reliability is used in the context of limit states (3.38(3.38),), it can be expressed as the probability that the limit is not exceeded.
...
Contents
- Introduction
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 événement environnemental anormal
- 3.2 événement accidentel
- 3.3 action
- 3.4 effet des actions
- 3.5 garde d'air
- 3.6 appartenances
- 3.7 système auxiliaire
- 3.8 variable de base
- 3.9 calibration
- 3.10 valeur caractéristique
- 3.11 tube conducteur
- 3.12 niveau de conséquences
- 3.13 état d'endommagement
- 3.14 abandon
- 3.15 approche de conception
- 3.16 critères de conception
- 3.17 méthode de conception
- 3.18 durée de vie en service
- 3.19 situation de conception
- 3.20 valeur conceptuelle
- 3.21 détérioration
- 3.22 ductilité
- 3.23 ductilité
- 3.24 ductilité
- 3.25 pérennité
- 3.26 événement environnemental extrême
- 3.27 installation
- 3.28 apte au service
- 3.29 structure fixe
- 3.30 structure flottante
- 3.31 risque
- 3.32 événement dangereux
- 3.33 entaille faite par la glace
- 3.34 incident
- 3.35 inspection
- 3.36 gestion de l'intégrité
- 3.37 plate-forme auto-élévatrice
- 3.38 état limite
- 3.39 maintenance
- 3.40 système marin
- 3.41 intégrité du système marin
- 3.42 valeur nominale
- 3.43 en mer
- 3.44 parc éolien en mer
- 3.45 structure éolienne en mer
- 3.46 sous-station éolienne en mer
- 3.47 structure d'éolienne en mer
- 3.48 exploitant
- 3.49 méthode aux coefficients partiels
- 3.50 performance
- 3.51 structure primaire
- 3.52 société de classification reconnue (recognized classification society)
- 3.53 fiabilité
- 3.54 approche de conception fondée sur la fiabilité
- 3.55 réparation
- 3.56 valeur représentative
- 3.57 résistance
- 3.58 période de retour
- 3.59 tube prolongateur
- 3.60 approche de conception tenant compte des risques
- 3.61 robustesse
- 3.62 affouillement
- 3.63 fond marin
- 3.64 sous-sol marin
- 3.65 structure secondaire
- 3.66 approche de conception semi-probabiliste
- 3.67 zone d'éclaboussure
- 3.68 élément de structure
- 3.69 intégrité structurelle
- 3.70 analyse de fiabilité structurale
- 3.71 structure
- 3.72 structure tertiaire
- 3.73 superstructures
- 4 Symboles et abréviations
- 4.1 Symboles
- 4.2 Termes abrégés
Introduction
Les Normes internationales pour les structures en mer élaborées par l'ISO TC 67/SC 7 comprennent:
- l'ISO 19900, la Norme internationale unificatrice pour les structures en mer;
- la série ISO 19901, fournissant des exigences spécifiques pour les structures en mer;
- l'ISO 19902, l'ISO 19903, la série ISO 19904, la série ISO 19905 et l'ISO 19906, des normes portant sur un «type de structure».
La Figure 1 illustre les relations entre les Normes internationales pour les structures en mer élaborées par l'ISO/TC 67/SC 7.
Figure 1 — Relations entre les Normes internationales pour les structures en mer élaborées par l'ISO/TC 67/SC 7 Les Normes internationales pour les structures en mer élaborées par l'ISO/TC 67/SC 7 suivent les principes de l'ISO 2394 et de l'ISO 22111, et constituent une base commune pour le traitement de la conception et de l'évaluation des structures en mer utilisées par les industries de l'énergie dans le monde. Des informations et recommandations supplémentaires sont données à l'Annex A, dont la numérotation correspond à celle des articles dans le corps du présent document pour faciliter la consultation. Les déclarations contenant les exigences («doit» et «ne doit pas»), les recommandations («il convient que» et «il ne convient pas que») ou les autorisations («peut») sont collectivement désignées en tant que «dispositions».
PROJET FINAL Norme internationale ISO/FDIS 19900:2026(fr) Exigences générales relatives aux structures en mer
1 Domaine d'application
Le présent document contient des exigences générales pour la conception des structures et systèmes marins et pour la gestion de l'intégrité structurelle. Il couvre à la fois les structures en mer fixes (prenant appui sur le fond marin) et les structures en mer flottantes.
Le présent document s'applique à toutes les phases de la durée de vie de la structure, y compris:
- avant l'exploitation (par exemple, la fabrication, le transport, l'installation);
- l'exploitation, à la fois pendant la durée de vie en service initialement spécifiée et pendant toute prolongation de la durée de vie;
- la mise à niveau, la réaffectation et la réutilisation fonctionnelles;
- l'abandon et l'enlèvement.
Le présent document se concentre sur les structures portantes primaires et secondaires, mais comprend également certaines dispositions pour les structures tertiaires et auxiliaires. Le présent document s'applique aux structures en mer pour le pétrole et le gaz, ainsi qu'aux structures en mer de traitement d'énergie à faible teneur en carbone.
Le présent document ne s'applique pas aux systèmes de conduites, aux systèmes de tubes prolongateurs, aux systèmes de câbles ou aux systèmes sous-marins.
2 Références normatives
Le présent document ne contient aucune référence normative.
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s'appliquent. L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l'adresse https:// www .iso .org/ obp
- IEC Electropedia: disponible à l'adresse https:// www .electropedia .org/
3.1 événement environnemental anormal
événement dangereux (3.32) environnemental ayant une faible probabilité d'occurrence au cours de la durée de vie en service (3.18) Note 1 à l'article: La probabilité d'occurrence choisie pour le niveau de conséquences (3.12) le plus élevé se situe −3 −4 généralement dans la plage de 10 par an (1 tous les 1 000 ans) à 10 par an (1 tous les 10 000 ans). Note 2 à l'article: Les événements environnementaux anormaux sont associés à des situations de conception (3.19) anormales, voir 7.2.
ISO/FDIS 19900:2026(fr)
3.2 événement accidentel
événement dangereux (3.32) non environnemental ayant une faible probabilité d'occurrence au cours de la durée de vie en service (3.18) Note 1 à l'article: La probabilité d'occurrence choisie pour le niveau de conséquences (3.12) le plus élevé se situe −3 −4 généralement dans la plage de 10 par an (1 tous les 1 000 ans) à 10 par an (1 tous les 10 000 ans). Note 2 à l'article: Les événements accidentels sont associés à une libération importante d'énergie, par exemple lors de collisions avec un navire, d'incendies et d'explosions.
Note 3 à l'article: Les événements accidentels sont associés à des situations de conception (3.19) accidentelles, voir 7.2. Les accidents de plus faible ampleur qui peuvent être attendus au cours de la durée de vie de la structure (3.71), par exemple la chute d'objets et des chocs de faible énergie avec un navire, sont appelés incidents (3.34) et sont traités dans le cadre de situations de conception (3.19) d'exploitation.
3.3 action
charge extérieure appliquée à la structure (3.71) (charge directe) ou déformation ou accélération imposée (charge indirecte) EXEMPLE Une déformation imposée peut être causée en appliquant des tolérances de fabrication, un tassement différentiel ou des variations de température ou d'humidité. Une accélération imposée peut être causée par un séisme. Note 1 à l'article: Les types d'action individuels sont classés à l'Article 9.
3.4 effet des actions
résultat des actions (3.3) sur un élément de structure (3.68), par exemple: force interne, moment, contrainte, déformation, ou sur la structure (3.71), par exemple: flexion, rotation
3.5 garde d'air
distance entre le niveau le plus élevé de la surface de l'eau et la partie exposée la plus basse de la structure primaire (3.51) du pont, qui n'est pas conçue pour supporter les effets des actions (3.4) dues à l'environnement pendant une période de retour (3.58) spécifiée Note 1 à l'article: Cette définition peut être précisée pour différents types d'installations (3.27) dans leurs normes respectives.
3.6 appartenances
accessoire ou fixation sur la structure (3.71) qui aide généralement à l'installation, assure l'accès ou la protection, ou transporte des fluides ou des gaz EXEMPLE Caisson, anodes, débarcadères, dispositif défense et cadres de protection. Note 1 à l'article: Les appartenances ne contribuent normalement pas à la rigidité de la structure (3.71), mais peuvent faire l'objet d'importantes charges environnementales.
3.7 système auxiliaire
système non soumis à la responsabilité de la discipline structurelle ou d'un groupe d'appartenances (3.6), fixé à la structure (3.71) ou à l'intérieur de celle-ci EXEMPLE Tubes prolongateurs (3.59), systèmes sous-marins, câbles, câbles ombilicaux.
ISO/FDIS 19900:2026(fr)
3.8 variable de base
variable se rapportant aux grandeurs physiques qui caractérisent les actions (3.3) et les incidences de l'environnement, les grandeurs géométriques et les propriétés des matériaux, y compris les propriétés des sols Note 1 à l'article: Les variables de base sont généralement des variables aléatoires ou des processus aléatoires utilisés dans le calcul ou l'évaluation des valeurs représentatives (3.56) d'actions (3.3) ou de résistance (3.57).
3.9 calibration
processus utilisé pour spécifier les critères d'acceptation pour différentes approches de conception (3.15) Note 1 à l'article: La calibration de code pour la méthode aux coefficients partiels (3.49), le coefficient partiel et les probabilités annuelles associés aux valeurs représentatives (3.56) sont basés sur l'expérience, les cas connus ou les objectifs de fiabilité. Pour d'autres méthodes dans l'approche de conception semi-probabiliste (3.66), cela peut impliquer le choix de coefficients de sécurité.
Note 2 à l'article: Pour les méthodes dans l'approche de conception fondée sur la fiabilité (3.54), un objectif de fiabilité peut être calibré par rapport à des cas sûrs avérés ou à des indices de risque.
3.10 valeur caractéristique
valeur attribuée à une variable de base (3.8) avec une probabilité de dépassement donnée Note 1 à l'article: Une variable de base (3.8) peut avoir deux valeurs caractéristiques ou plus, par exemple une valeur supérieure et une valeur inférieure.
3.11 tube conducteur
canalisation tubulaire installée dans le sol pour assurer une fondation structurelle initiale stable, afin d'installer l'enveloppe de surface et de protéger la ligne interne du puits des actions (3.3) océano-météorologiques Note 1 à l'article: Le tube conducteur fournit un support latéral (et dans certains cas axial), permet la circulation des fluides de forage et guide la garniture de forage afin de faciliter l'installation du tubage de surface.
3.12 niveau de conséquences
système de classification utilisé pour établir les critères pertinents pour une structure (3.71) à partir des conséquences d'une ruine structurelle
3.13 état d'endommagement
état discret qui décrit le niveau de dégradation Note 1 à l'article: Les états d'endommagement peuvent être classés entre l'absence d'endommagement et la perte complète d'une structure (3.71) ou d'un système marin (3.40).
3.14 abandon
processus qui consiste à arrêter l'exploitation d'une installation (3.27), permettant la préparation des opérations de nettoyage, de démontage et d'enlèvement à, ou après, la fin de sa durée de vie en service (3.18)
3.15 approche de conception
cadre utilisé pour assurer des performances de structure (3.71) acceptables Note 1 à l'article: Les approches de conception sont classées comme semi-probabiliste (3.66), fondée sur la fiabilité (3.54) et tenant compte des risques (3.60).
ISO/FDIS 19900:2026(fr) Note 2 à l'article: Différentes approches de conception peuvent être appliquées pour différentes situations de conception (3.19).
Note 3 à l'article: Des performances de structure (3.71) acceptables sont obtenues en satisfaisant à des critères d'état limite (3.38).
Note 4 à l'article: Différentes méthodes de conception (3.17) peuvent être appliquées au sein d'une approche de conception.
3.16 critères de conception
formulations quantitatives utilisant les valeurs conceptuelles (3.20) décrivant les conditions à remplir pour chaque situation de conception (3.19)
3.17 méthode de conception
procédure éprouvée, classée au sein d'une approche de conception (3.15), utilisée pour démontrer la sécurité d'une structure (3.71) Note 1 à l'article: La sécurité peut impliquer une vérification aux états limites (3.38), ou prendre en compte des conséquences et incertitudes pertinentes.
3.18 durée de vie en service
durée de vie de conception durée de vie période prévue d'utilisation d'une structure (3.71) pour un usage déterminé, sous condition de maintenance (3.39), mais sans que des réparations (3.55) substantielles ne soient nécessaires Note 1 à l'article: La durée de vie en service initialement spécifiée peut être mise à jour au cours de la phase d'exploitation pour inclure toutes prolongations de la durée d'exploitation jusqu'à enlèvement de l'installation (3.27).
3.19 situation de conception
ensemble de conditions physiques en fonction duquel la structure (3.71) ou ses éléments sont soumis à une vérification aux états limites (3.38) Note 1 à l'article: Six situations de conception sont classées dans le Tableau 2: d'exploitation, extrême, anormale, accidentelle, de courte durée et d'aptitude au service.
3.20 valeur conceptuelle
valeur déduite de la valeur représentative (3.56) à introduire dans l'approche de conception semi-probabiliste (3.66) Note 1 à l'article: Les valeurs conceptuelles peuvent être différentes en fonction des différentes situations de conception (3.19) et des coefficients partiels de sécurité associés.
Note 2 à l'article: La valeur conceptuelle pour la résistance est calculée en divisant sa valeur représentative (3.56) par un coefficient partiel pour la résistance (3.57), alors que la valeur conceptuelle (3.20) de l'effet des actions (3.4) est calculée en multipliant sa valeur représentative (3.56) par un coefficient partiel pour l'action (3.3) ou l'effet des actions (3.4).
3.21 détérioration
processus qui altère l'intégrité structurelle (3.69) au fil du temps Note 1 à l'article: La détérioration peut être due à des processus chimiques, physiques ou biologiques naturels, y compris la corrosion, à des actions dues à l'environnement (3.3), à des incidents (3.34) et actions accidentelles (3.3), à la fatigue, l'usure, l'abrasion, et à une exploitation et une maintenance (3.39) inappropriées de la structure (3.71).
ISO/FDIS 19900:2026(fr)
3.22 ductilité
<matériau> aptitude d'un matériau à se déformer et à absorber l'énergie au-delà de sa limite d'élasticité
3.23 ductilité
<élément de structure> aptitude d'un élément de structure (3.68) à résister aux effets des actions (3.4) audelà de sa limite d'élasticité
3.24 ductilité
<système structurel> aptitude d'un système structurel à se déformer, à dissiper l'énergie et à redistribuer les effets des actions (3.4)
3.25 pérennité
aptitude d'une structure (3.71) ou d'un élément de structure (3.68) à maintenir son fonctionnement tout au long de sa durée de vie en service (3.18)
3.26 événement environnemental extrême
−2 événement dangereux (3.32) environnemental ayant généralement une probabilité d'occurrence de 10 par an (1 tous les 100 ans) pour le niveau de conséquences (3.12) le plus élevé Note 1 à l'article: Les événements environnementaux extrêmes sont associés à des situations de conception (3.19) extrêmes, voir 7.2.
Note 2 à l'article: Pour les structures éoliennes en mer (3.45) et les plates-formes auto-élévatrices (3.37), une probabilité −2 d'occurrence de 2 x 10 par an (1 tous les 50 ans) est généralement appliquée.
3.27 installation
constructions, pièces d'équipement et services fournis pour le secteur de l'énergie en mer (3.43) Note 1 à l'article: L'installation comprend la structure (3.71) et des systèmes non structurels tels que des équipements de superstructures (3.73), des systèmes marins (3.40), des canalisations et des logements. Note 2 à l'article: Une installation d'hydrocarbures (plate-forme) comprend les appartenances (3.6) structurelles et les systèmes auxiliaires (3.7), mais pas les éléments autres que les éléments de structure (3.68) des puits d'hydrocarbures. Note 3 à l'article: L'installation ne comprend pas les couches géologiques supportant la fondation. Néanmoins, les paramètres géotechniques spécifiques au site fournissent les conditions de limite nécessaires pour modéliser la fondation ou l'ancrage de l'installation.
3.28 apte au service
en conformité aux exigences structurelles applicables Note 1 à l'article: La conformité à la présente norme indique que la structure (3.71) fournit le niveau exigé de sécurité structurelle, de fonctionnalité et d'intégrité pour les conditions de conception et d'exploitation définies et la période d'évaluation.
Note 2 à l'article: L'approche de conception tenant compte des risques (3.60) ou l'approche de conception fondée sur la fiabilité (3.54) peut être utilisée pour démontrer la conformité, lorsque cela est autorisé, voir 10.3.
3.29 structure fixe
structure (3.71) qui prend appui sur le fond marin et qui répercute sur le sous-sol marin (3.64) la plupart des actions (3.3) qui lui sont appliquées
3.30 structure flottante
structure (3.71) dont le poids est supporté en totalité par la poussée hydrostatique
ISO/FDIS 19900:2026(fr)
3.31 risque
source potentielle de préjudice Note 1 à l'article: Le préjudice est généralement différencié entre préjudice pour les personnes, préjudice pour l'environnement, préjudice en termes de coûts pour les organismes, ou préjudice pour la société en général.
3.32 événement dangereux
événement se produisant lorsqu'un risque (3.31) interagit avec une structure (3.71) EXEMPLE Vague frappant la structure (3.71), iceberg heurtant la structure (3.71), poids excessif de superstructures (3.73) ajoutées à la structure (3.71), collision avec un navire, incendie, explosion et glissement de terrain à proximité des ancrages structurels (pieux).
Note 1 à l'article: Un événement dangereux peut être une tempête impliquant des vagues, des courants et des vents agissant depuis différentes directions.
Note 2 à l'article: Un événement dangereux peut être une combinaison de variables de base (3.8) telles que la hauteur et la période des vagues, ou la taille et la vitesse de déplacement de la banquise. Note 3 à l'article: Un événement dangereux peut être une action (3.3) associée à un risque (3.31) qui implique diverses combinaisons de variables de base (3.8).
3.33 entaille faite par la glace
affouillement de la glace incision du sous-sol marin (3.64) ou érosion des matériaux du sous-sol marin (3.64) par un bloc de glace
3.34 incident
événement dangereux (3.32) non environnemental pris en compte dans une situation de conception (3.19) d'exploitation Note 1 à l'article: Un incident est un événement accidentel (3.2) de moindre ampleur, associé à un éventuel endommagement local ou à un endommagement des éléments de structure (3.68), ayant une faible probabilité −2 d'occurrence, généralement associée à des probabilités supérieures à 10 par an (1 tous les 100 ans).
3.35 inspection
examen sur site dans le cadre du contrôle qualité et de l'évaluation de l'état visant à évaluer l'état présent d'une structure (3.71)
3.36 gestion de l'intégrité
processus systématique destiné à assurer l'intégrité d'une structure (3.71) ou d'un système marin (3.40)
3.37 plate-forme auto-élévatrice
unité mobile en mer (3.43) dotée d'une coque à poussée hydrostatique et d'une ou plusieurs jambes auxquelles un mouvement ascendant et descendant par rapport à la coque peut être imprimé Note 1 à l'article: Une plate-forme auto-élévatrice atteint son mode de fonctionnement en abaissant la ou les jambes jusqu'à ce qu'elles viennent prendre appui sur le sous-sol marin (3.64), puis en soulevant la coque jusqu'à la hauteur exigée. La majorité des plates-formes auto-élévatrices comptent trois jambes ou plus dont chacune peut être déplacée indépendamment et qui sont supportées dans le sous-sol marin (3.64) par des caissons de support.
3.38 état limite
état au-delà duquel la structure (3.71) ou l'élément de structure (3.68) ne satisfait plus aux critères de conception (3.16) Note 1 à l'article: Trois états limites sont classés à l'Article 8: ultime, de service et de fatigue.
ISO/FDIS 19900:2026(fr)
3.39 maintenance
travaux de routine entrepris pour assurer la continuité des performances d'une installation (3.27)
3.40 système marin
système contribuant à la sécurité structurelle, à la stabilité et à la capacité de maintien en position d'une installation (3.27) flottante
3.41 intégrité du système marin
aptitude d'un système marin (3.40) à maintenir sa performance (3.50) pendant sa durée de vie en service (3.18) au regard de la sécurité structurelle, de la robustesse (3.61), de l'aptitude au service et de la pérennité (3.25)
3.42 valeur nominale
valeur attribuée à une variable de base (3.8) sur une base non statistique, déterminée à partir de l'expérience acquise ou des conditions physiques, ou telle que spécifiée dans un code ou une norme publié(e)
3.43 en mer
situé dans l'eau à une certaine distance du rivage Note 1 à l'article: L'expression «proche du rivage» ou «côtier/côtière» peut être utilisée pour spécifier des emplacements proches de la côte ou dans des embouchures de fleuves.
3.44 parc éolien en mer
groupe de structures d'éolienne en mer (3.47) et de sous-stations éoliennes en mer (3.46) au même emplacement
3.45 structure éolienne en mer
partie d'une installation (3.27) d'éolienne en mer qui s'étend vers le haut depuis le sous-sol marin (3.64) et raccorde la fondation au mât de l'éolienne, ou partie d'une sous-station éolienne en mer (3.46) qui supporte les superstructures (3.73) Note 1 à l'article: La structure éolienne en mer peut comprendre une pièce de transition.
...