Leather — Chemical determination of metal content — Part 1: Extractable metals

This document specifies a method for the determination of extractable metals in leather using extraction with an acid artificial-perspiration solution and subsequent determination with inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), atomic absorption spectrometry (AAS) or spectrometry of atomic fluorescence (SFA). This method determines extractable metals in leather; it is not compound-specific or specific to the oxidation state of the metals. This method is especially suitable for determining the extractable chromium in chromium-tanned leathers.

Cuir — Détermination chimique de la teneur en métal — Partie 1: Métaux extractibles

Le présent document spécifie une méthode de détermination des métaux extractibles du cuir s'appuyant sur l'extraction à l'aide d'une solution de sueur artificielle acide suivie d'une détermination par spectrométrie d'émission optique avec plasma à couplage inductif (ICP-OES), par spectrométrie de masse avec plasma à couplage inductif (ICP-MS), par spectrométrie d'absorption atomique (AAS) ou par spectrométrie de fluorescence atomique (SFA). La présente méthode détermine les métaux extractibles présents dans le cuir. Elle n'est pas spécifique à un composé ou à l'état d'oxydation des métaux. La présente méthode est particulièrement adaptée à la détermination du chrome extractible dans les cuirs tannés au chrome.

General Information

Status
Published
Publication Date
27-Feb-2019
Current Stage
9092 - International Standard to be revised
Due Date
29-Nov-2024
Completion Date
29-Nov-2024
Ref Project

Relations

Buy Standard

Standard
ISO 17072-1:2019 - Leather — Chemical determination of metal content — Part 1: Extractable metals Released:2/28/2019
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 17072-1:2019 - Leather -- Chemical determination of metal content
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 17072-1:2019 - Cuir — Détermination chimique de la teneur en métal — Partie 1: Métaux extractibles Released:2/28/2019
French language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 17072-1:2019 - Cuir -- Détermination chimique de la teneur en métal
French language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 17072-1
IULTCS/IUC27-1
Second edition
2019-02
Leather — Chemical determination of
metal content —
Part 1:
Extractable metals
Cuir — Détermination chimique de la teneur en métal —
Partie 1: Métaux extractibles
Reference numbers
IULTCS/IUC27-1:2019(E)
©
ISO 2019
IULTCS/IUC27-1:2019(E)
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

IULTCS/IUC27-1:2019(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 2
5 Reagents . 2
6 Apparatus and materials. 3
7 Sampling and sample preparation . 3
8 Procedure. 4
8.1 Preparation of acid artificial-perspiration solution . 4
8.2 Extraction of leather sample . 4
8.3 Analysis by ICP, AAS and SFA . 4
8.3.1 General. 4
8.3.2 ICP. 5
8.3.3 AAS . 5
8.3.4 Analysis by SFA technique . 5
9 Calculation and expression of results . 5
10 Test report . 6
Annex A (informative) Interlaboratory test results and quantification limits .7
Bibliography . 8
IULTCS/IUC27-1:2019(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/iso/foreword .html.
This document was prepared by the Chemical Test Commission of the International Union of Leather
Technologists and Chemists Societies (IUC Commission, IULTCS) in collaboration with the European
Committee for Standardization (CEN) Technical Committee CEN/TC 289, Leather, the secretariat of
which is held by UNI, in accordance with the agreement on technical cooperation between ISO and CEN
(Vienna Agreement).
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to
further the advancement of leather science and technology. IULTCS has three Commissions, which
are responsible for establishing international methods for the sampling and testing of leather. ISO
recognizes IULTCS as an international standardizing body for the preparation of test methods for
leather.
This second edition cancels and replaces the first edition (ISO 17072-1:2011), which has been technically
revised as follows:
— the Scope and Clauses 5, 6, 7, 8.3, 9 and 10 have been editorially modified;
— 7.2 and 8.2 have been technically modified. 7.2 refers to ISO 4044 for sample preparation, which
requires the user to grind sufficiently large pieces of leather or cut small pieces of leather;
— the previous subclauses 6.3 and 7.3 from ISO 17072-1:2011 have been deleted.
A list of all parts in the ISO 17072 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2019 – All rights reserved

INTERNATIONAL STANDARD
IULTCS/IUC27-1:2019(E)
Leather — Chemical determination of metal content —
Part 1:
Extractable metals
1 Scope
This document specifies a method for the determination of extractable metals in leather using extraction
with an acid artificial-perspiration solution and subsequent determination with inductively coupled
plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-
MS), atomic absorption spectrometry (AAS) or spectrometry of atomic fluorescence (SFA).
This method determines extractable metals in leather; it is not compound-specific or specific to the
oxidation state of the metals. This method is especially suitable for determining the extractable
chromium in chromium-tanned leathers.
The method is applicable for the determination of many extractable metals, including:
Aluminium (Al) Copper (Cu) Nickel (Ni)
Antimony (Sb) Iron (Fe) Potassium (K)
Arsenic (As) Lead (Pb) Selenium (Se)
Barium (Ba) Magnesium (Mg) Tin (Sn)
Cadmium (Cd) Manganese (Mn) Titanium (Ti)
Calcium (Ca) Mercury (Hg) Zinc (Zn)
Chromium (Cr) Molybdenum (Mo) Zirconium (Zr)
Cobalt (Co)
Interlaboratory test results and the quantification limits possible with ICP-OES are given in Table A.1
and Table A.2 of Annex A.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 105-E04, Textiles — Tests for colour fastness — Part E04: Colour fastness to perspiration
ISO 2418, Leather — Chemical, physical and mechanical and fastness tests — Sampling location
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 4044, Leather — Chemical tests — Preparation of chemical test samples
ISO 4684, Leather — Chemical tests — Determination of volatile matter
ISO 11885, Water quality — Determination of selected elements by inductively coupled plasma optical
emission spectrometry (ICP-OES)
ISO 15586, Water quality — Determination of trace elements using atomic absorption spectrometry with
graphite furnace
IULTCS/IUC27-1:2019(E)
ISO 17294-2, Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) —
Part 2: Determination of selected elements including uranium isotopes
ISO 17852, Water quality — Determination of mercury — Method using atomic fluorescence spectrometry
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
4 Principle
A sample of leather is extracted at (37 ± 2) °C for 4 h ± 5 min in an acid artificial-perspiration solution.
The extract solution is filtered, acidified and analysed by ICP, SFA or AAS.
The results are reported on the dry matter of the leather.
5 Reagents
WARNING — The concentrated acids used in this method are very corrosive and/or oxidising
liquids, which could raise the possibility of fire in the event of contact with ignitable materials
and promote an existing fire considerably, or could decompose explosively with warming. They
might cause acute or chronic health dangers as well. Moreover, they are hazardous to water.
Suitable safety measures are therefore necessary.
5.1 General
Unless otherwise stated, only analytical grade chemicals shall be used. All solutions are aqueous
solutions.
5.2 Nitric acid, 60 % to 70 % concentration (by mass).
5.3 L-histidine monohydrochloride monohydrate.
5.4 Sodium chloride.
5.5 Sodium dihydrogen phosphate dihydrate.
5.6 Sodium hydroxide, 0,1 mol/l.
5.7 Element stock solutions, of the various metals with mass concentrations of 1 000 mg/l each.
5.8 Nitric acid, 0,1 mol/l.
5.9 Water, grade 3 in accordance with ISO 3696.
5.10 Solution of gold (Au), in hydrochloric acid or potassium permanganate, 1 000 µg/l.
2 © ISO 2019 – All rights reserved

IULTCS/IUC27-1:2019(E)
6 Apparatus and materials
6.1 General
All glassware, analytical devices and materials, including filters, shall be suitable for analysis of
trace metals.
Use normal laboratory apparatus and, in particular, the following.
6.2 Laboratory oven, capable of maintaining (102 ± 2) °C.
6.3 Analytical balance, with an accuracy of 0,1 mg.
6.4 Laboratory balance, with an accuracy of 0,01 g.
6.5 Membrane filters and holder, suitable for filtering aqueous solutions, with a pore size of 0,45 μm.
6.6 Filtration device, using glass fibre (GFC) or membrane type filters.
6.7 Volumetric flasks, of various sizes (50 ml, 100 ml, 1 000 ml).
6.8 Erlenmeyer flasks, of approximately 250 ml capacity, with stoppers.
6.9 Volumetric conical flasks, of various sizes.
6.10 Water bath, capable of maintaining (37 ± 2) °C, fitted with a horizontal flask shaker, frequency
(60 ± 5) rpm, or orbital shaker, frequency (100 ± 10) rpm.
6.11 Inductively coupled plasma optical emission spectrometer (ICP-OES) (see ISO 11885), with a
hydride-generator module. The gases used shall be of analytical grade.
6.12 Flame or graphite-furnace atomic absorption spectrometer (AAS) (see ISO 15586), with a
hydride-generator module and suitable burner heads, and hollow-cathode-lamps. The gases used shall
be of analytical grade.
6.13 Inductively coupled plasma mass spectrometer (ICP-MS) (see ISO 17294-2). The gases used
shall be of analytical grade.
6.14 Atomic fluorescence spectrometer (SFA), for mercury analysis.
7 Sampling and sample preparation
7.1 If the leather piece available for testing is a
...


INTERNATIONAL ISO
STANDARD 17072-1
IULTCS/IUC27-1
Second edition
2019-02
Leather — Chemical determination of
metal content —
Part 1:
Extractable metals
Cuir — Détermination chimique de la teneur en métal —
Partie 1: Métaux extractibles
Reference numbers
IULTCS/IUC27-1:2019(E)
©
ISO 2019
IULTCS/IUC27-1:2019(E)
© ISO 2019
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved

IULTCS/IUC27-1:2019(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Principle . 2
5 Reagents . 2
6 Apparatus and materials. 3
7 Sampling and sample preparation . 3
8 Procedure. 4
8.1 Preparation of acid artificial-perspiration solution . 4
8.2 Extraction of leather sample . 4
8.3 Analysis by ICP, AAS and SFA . 4
8.3.1 General. 4
8.3.2 ICP. 5
8.3.3 AAS . 5
8.3.4 Analysis by SFA technique . 5
9 Calculation and expression of results . 5
10 Test report . 6
Annex A (informative) Interlaboratory test results and quantification limits .7
Bibliography . 8
IULTCS/IUC27-1:2019(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: www .iso .org/iso/foreword .html.
This document was prepared by the Chemical Test Commission of the International Union of Leather
Technologists and Chemists Societies (IUC Commission, IULTCS) in collaboration with the European
Committee for Standardization (CEN) Technical Committee CEN/TC 289, Leather, the secretariat of
which is held by UNI, in accordance with the agreement on technical cooperation between ISO and CEN
(Vienna Agreement).
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to
further the advancement of leather science and technology. IULTCS has three Commissions, which
are responsible for establishing international methods for the sampling and testing of leather. ISO
recognizes IULTCS as an international standardizing body for the preparation of test methods for
leather.
This second edition cancels and replaces the first edition (ISO 17072-1:2011), which has been technically
revised as follows:
— the Scope and Clauses 5, 6, 7, 8.3, 9 and 10 have been editorially modified;
— 7.2 and 8.2 have been technically modified. 7.2 refers to ISO 4044 for sample preparation, which
requires the user to grind sufficiently large pieces of leather or cut small pieces of leather;
— the previous subclauses 6.3 and 7.3 from ISO 17072-1:2011 have been deleted.
A list of all parts in the ISO 17072 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/members .html.
iv © ISO 2019 – All rights reserved

INTERNATIONAL STANDARD
IULTCS/IUC27-1:2019(E)
Leather — Chemical determination of metal content —
Part 1:
Extractable metals
1 Scope
This document specifies a method for the determination of extractable metals in leather using extraction
with an acid artificial-perspiration solution and subsequent determination with inductively coupled
plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-
MS), atomic absorption spectrometry (AAS) or spectrometry of atomic fluorescence (SFA).
This method determines extractable metals in leather; it is not compound-specific or specific to the
oxidation state of the metals. This method is especially suitable for determining the extractable
chromium in chromium-tanned leathers.
The method is applicable for the determination of many extractable metals, including:
Aluminium (Al) Copper (Cu) Nickel (Ni)
Antimony (Sb) Iron (Fe) Potassium (K)
Arsenic (As) Lead (Pb) Selenium (Se)
Barium (Ba) Magnesium (Mg) Tin (Sn)
Cadmium (Cd) Manganese (Mn) Titanium (Ti)
Calcium (Ca) Mercury (Hg) Zinc (Zn)
Chromium (Cr) Molybdenum (Mo) Zirconium (Zr)
Cobalt (Co)
Interlaboratory test results and the quantification limits possible with ICP-OES are given in Table A.1
and Table A.2 of Annex A.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 105-E04, Textiles — Tests for colour fastness — Part E04: Colour fastness to perspiration
ISO 2418, Leather — Chemical, physical and mechanical and fastness tests — Sampling location
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 4044, Leather — Chemical tests — Preparation of chemical test samples
ISO 4684, Leather — Chemical tests — Determination of volatile matter
ISO 11885, Water quality — Determination of selected elements by inductively coupled plasma optical
emission spectrometry (ICP-OES)
ISO 15586, Water quality — Determination of trace elements using atomic absorption spectrometry with
graphite furnace
IULTCS/IUC27-1:2019(E)
ISO 17294-2, Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) —
Part 2: Determination of selected elements including uranium isotopes
ISO 17852, Water quality — Determination of mercury — Method using atomic fluorescence spectrometry
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https: //www .iso .org/obp
— IEC Electropedia: available at http: //www .electropedia .org/
4 Principle
A sample of leather is extracted at (37 ± 2) °C for 4 h ± 5 min in an acid artificial-perspiration solution.
The extract solution is filtered, acidified and analysed by ICP, SFA or AAS.
The results are reported on the dry matter of the leather.
5 Reagents
WARNING — The concentrated acids used in this method are very corrosive and/or oxidising
liquids, which could raise the possibility of fire in the event of contact with ignitable materials
and promote an existing fire considerably, or could decompose explosively with warming. They
might cause acute or chronic health dangers as well. Moreover, they are hazardous to water.
Suitable safety measures are therefore necessary.
5.1 General
Unless otherwise stated, only analytical grade chemicals shall be used. All solutions are aqueous
solutions.
5.2 Nitric acid, 60 % to 70 % concentration (by mass).
5.3 L-histidine monohydrochloride monohydrate.
5.4 Sodium chloride.
5.5 Sodium dihydrogen phosphate dihydrate.
5.6 Sodium hydroxide, 0,1 mol/l.
5.7 Element stock solutions, of the various metals with mass concentrations of 1 000 mg/l each.
5.8 Nitric acid, 0,1 mol/l.
5.9 Water, grade 3 in accordance with ISO 3696.
5.10 Solution of gold (Au), in hydrochloric acid or potassium permanganate, 1 000 µg/l.
2 © ISO 2019 – All rights reserved

IULTCS/IUC27-1:2019(E)
6 Apparatus and materials
6.1 General
All glassware, analytical devices and materials, including filters, shall be suitable for analysis of
trace metals.
Use normal laboratory apparatus and, in particular, the following.
6.2 Laboratory oven, capable of maintaining (102 ± 2) °C.
6.3 Analytical balance, with an accuracy of 0,1 mg.
6.4 Laboratory balance, with an accuracy of 0,01 g.
6.5 Membrane filters and holder, suitable for filtering aqueous solutions, with a pore size of 0,45 μm.
6.6 Filtration device, using glass fibre (GFC) or membrane type filters.
6.7 Volumetric flasks, of various sizes (50 ml, 100 ml, 1 000 ml).
6.8 Erlenmeyer flasks, of approximately 250 ml capacity, with stoppers.
6.9 Volumetric conical flasks, of various sizes.
6.10 Water bath, capable of maintaining (37 ± 2) °C, fitted with a horizontal flask shaker, frequency
(60 ± 5) rpm, or orbital shaker, frequency (100 ± 10) rpm.
6.11 Inductively coupled plasma optical emission spectrometer (ICP-OES) (see ISO 11885), with a
hydride-generator module. The gases used shall be of analytical grade.
6.12 Flame or graphite-furnace atomic absorption spectrometer (AAS) (see ISO 15586), with a
hydride-generator module and suitable burner heads, and hollow-cathode-lamps. The gases used shall
be of analytical grade.
6.13 Inductively coupled plasma mass spectrometer (ICP-MS) (see ISO 17294-2). The gases used
shall be of analytical grade.
6.14 Atomic fluorescence spectrometer (SFA), for mercury analysis.
7 Sampling and sample preparation
7.1 If the leather piece available for testing is a
...


NORME ISO
INTERNATIONALE 17072-1
IULTCS/IUC27-1
Deuxième édition
2019-02
Cuir — Détermination chimique de la
teneur en métal —
Partie 1:
Métaux extractibles
Leather — Chemical determination of metal content —
Part 1: Extractable metals
Numéros de référence
IULTCS/IUC27-1:2019(F)
©
ISO 2019
IULTCS/IUC27-1:2019(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés

IULTCS/IUC27-1:2019(F)
Sommaire Page
Avant-propos .iv
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Principe . 2
5 Réactifs . 2
6 Appareillage et matériel . 3
7 Échantillonnage et préparation des échantillons . 3
8 Mode opératoire. 4
8.1 Préparation d’une solution de sueur artificielle acide . 4
8.2 Extraction d’un échantillon de cuir . 4
8.3 Analyse par ICP, AAS et SFA . 4
8.3.1 Généralités . 4
8.3.2 ICP. 5
8.3.3 AAS . 5
8.3.4 Analyse par la technique SFA . 5
9 Calcul et expression des résultats . 5
10 Rapport d’essai . 6
Annexe A (informative) Résultats de l’essai interlaboratoires et limites de quantification .7
Bibliographie . 8
IULTCS/IUC27-1:2019(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos.
Le présent document a été élaboré par la Commission des essais chimiques de l’Union internationale des
sociétés de techniciens et chimistes du cuir (commission IUC, IULTCS), en collaboration avec le comité
technique du Comité européen de normalisation (CEN) CEN/TC 289, Cuir, dont le secrétariat est tenu
par l'UNI, conformément à l’accord de coopération technique entre l’ISO et le CEN (Accord de Vienne).
L’IULTCS est une organisation mondiale de sociétés professionnelles des industries du cuir fondée en
1897 ayant pour mission de favoriser l’avancement des sciences et technologies du cuir. L’IULTCS a trois
commissions, qui sont responsables de l’établissement des méthodes internationales d’échantillonnage
et d’essai des cuirs. L’ISO reconnaît l’IULTCS en tant qu’organisme international à activités normatives
pour l’élaboration de méthodes d’essai relatives au cuir.
Cette deuxième édition annule et remplace la première édition (ISO 17072-1:2011), qui a fait l’objet
d’une révision technique comme suit:
— le Domaine d’application et les Articles 5, 6, 7, 8.3, 9 et 10 ont fait l’objet de modifications éditoriales;
— 7.2 et 8.2 ont fait l’objet de modifications techniques. 7.2 fait référence à l’ISO 4044 pour la préparation
des échantillons, laquelle exige des utilisateurs de broyer des morceaux de cuir suffisamment larges
ou de découper de petits morceaux de cuir;
— les précédents paragraphes 6.3 et 7.3 de l’ISO 17072-1:2011 ont été supprimés.
Une liste de toutes les parties de la série ISO 17072 peut être trouvée sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
iv © ISO 2019 – Tous droits réservés

NORME INTERNATIONALE
IULTCS/IUC27-1:2019(F)
Cuir — Détermination chimique de la teneur en métal —
Partie 1:
Métaux extractibles
1 Domaine d’application
Le présent document spécifie une méthode de détermination des métaux extractibles du cuir
s’appuyant sur l’extraction à l’aide d’une solution de sueur artificielle acide suivie d’une détermination
par spectrométrie d’émission optique avec plasma à couplage inductif (ICP-OES), par spectrométrie de
masse avec plasma à couplage inductif (ICP-MS), par spectrométrie d’absorption atomique (AAS) ou
par spectrométrie de fluorescence atomique (SFA).
La présente méthode détermine les métaux extractibles présents dans le cuir. Elle n’est pas spécifique à
un composé ou à l’état d’oxydation des métaux. La présente méthode est particulièrement adaptée à la
détermination du chrome extractible dans les cuirs tannés au chrome.
La méthode s’applique également à la détermination de nombreux métaux extractibles, dont:
Aluminium (Al) Cuivre (Cu) Nickel (Ni)
Antimoine (Sb) Fer (Fe) Potassium (K)
Arsenic (As) Plomb (Pb) Sélénium (Se)
Baryum (Ba) Magnésium (Mg) Étain (Sn)
Cadmium (Cd) Manganèse (Mn) Titane (Ti)
Calcium (Ca) Mercure (Hg) Zinc (Zn)
Chrome (Cr) Molybdène (Mo) Zirconium (Zr)
Cobalt (Co)
Les résultats de l’essai interlaboratoires et les limites de quantification possibles avec l’ICP-OES sont
indiqués dans les Tableaux A.1 et A.2 de l’Annexe A.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s'applique (y compris les
éventuels amendements).
ISO 105-E04, Textiles — Essais de solidité des coloris — Partie E04: Solidité des coloris à la sueur
ISO 2418, Cuir — Essais chimiques, physiques, mécaniques et de solidité — Emplacement de l'échantillonnage
ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
ISO 4044, Cuir — Essais chimiques - Préparation des échantillons pour essais chimiques
ISO 4684, Cuir — Essais chimiques — Détermination des matières volatiles
ISO 11885, Qualité de l'eau — Dosage d'éléments choisis par spectroscopie d'émission optique avec plasma
induit par haute fréquence (ICP-OES)
IULTCS/IUC27-1:2019(F)
ISO 15586, Qualité de l'eau — Dosage des éléments traces par spectrométrie d'absorption atomique en four
graphite
ISO 17294-2, Qualité de l'eau — Application de la spectrométrie de masse avec plasma à couplage inductif
(ICP-MS) — Partie 2: Dosage des éléments sélectionnés y compris les isotopes d'uranium
ISO 17852, Qualité de l'eau — Dosage du mercure — Méthode par spectrométrie de fluorescence atomique
3 Termes et définitions
Aucun terme n’est défini dans le présent document.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https: //www .iso .org/obp;
— IEC Electropedia: disponible à l’adresse http: //www .electropedia .org/.
4 Principe
Un échantillon de cuir est placé pour extraction à (37 ± 2) °C pendant 4 h ± 5 min dans une solution de
sueur artificielle acide. La solution extraite est filtrée, acidifiée et analysée par ICP, SFA ou AAS.
Les résultats sont donnés par rapport à la matière sèche du cuir.
5 Réactifs
AVERTISSEMENT — Les acides concentrés utilisés dans la présente méthode sont des liquides
très corrosifs et/ou oxydants qui peuvent augmenter la possibilité d’incendie en cas de contact
avec des matériaux inflammables et attiser fortement un incendie existant, ou qui peuvent se
décomposer de manière explosive en chauffant. Ils peuvent également entraîner des risques
graves ou chroniques pour la santé. En outre, ils sont dangereux pour l’eau. Des mesures de
sécurité appropriées sont par conséquent nécessaires.
5.1 Généralités
Sauf indication contraire, seuls des produits chimiques de qualité analytique doivent être utilisés.
Toutes les solutions sont aqueuses.
5.2 Acide nitrique de concentration massique comprise entre 60 % et 70 %.
5.3 Monochlorohydrate de l-histidine monohydraté
5.4 Chlorure de sodium
5.5 Dihydrogénophosphate de sodium dihydraté
5.6 Hydroxyde de sodium, 0,1 mol/l.
5.7 Solutions mères des éléments des différents métaux, présentant des concentrations massiques
de 1 000 mg/l chacune.
5.8 Acide nitrique, 0,1 mol/l.
2 © ISO 2019 – Tous droits réservés

IULTCS/IUC27-1:2019(F)
5.9 Eau de qualité 3 conformément à l’ISO 3696.
5.10 Solution d’or (Au), dans de l’acide chlorhydrique ou du permanganate de potassium, 1 000 µg/l.
6 Appareillage et matériel
6.1 Généralités
L’ensemble de la verrerie, des dispositifs d’analyse et du matériel de laboratoire, filtres compris, doivent
être adaptés à l’analyse des métaux à l’état de trace.
Utiliser l’appareillage de laboratoire courant et, en particulier, ce qui suit.
6.2 Étuve de laboratoire pouvant être maintenue à (102 ± 2) °C.
6.3 Balance analytique d’une exactitude de 0,1 mg.
6.4 Balance de laboratoire d’une exactitude de 0,01
...


NORME ISO
INTERNATIONALE 17072-1
IULTCS/IUC27-1
Deuxième édition
2019-02
Cuir — Détermination chimique de la
teneur en métal —
Partie 1:
Métaux extractibles
Leather — Chemical determination of metal content —
Part 1: Extractable metals
Numéros de référence
IULTCS/IUC27-1:2019(F)
©
ISO 2019
IULTCS/IUC27-1:2019(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2019
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii © ISO 2019 – Tous droits réservés

IULTCS/IUC27-1:2019(F)
Sommaire Page
Avant-propos .iv
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Principe . 2
5 Réactifs . 2
6 Appareillage et matériel . 3
7 Échantillonnage et préparation des échantillons . 3
8 Mode opératoire. 4
8.1 Préparation d’une solution de sueur artificielle acide . 4
8.2 Extraction d’un échantillon de cuir . 4
8.3 Analyse par ICP, AAS et SFA . 4
8.3.1 Généralités . 4
8.3.2 ICP. 5
8.3.3 AAS . 5
8.3.4 Analyse par la technique SFA . 5
9 Calcul et expression des résultats . 5
10 Rapport d’essai . 6
Annexe A (informative) Résultats de l’essai interlaboratoires et limites de quantification .7
Bibliographie . 8
IULTCS/IUC27-1:2019(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www .iso .org/iso/fr/avant -propos.
Le présent document a été élaboré par la Commission des essais chimiques de l’Union internationale des
sociétés de techniciens et chimistes du cuir (commission IUC, IULTCS), en collaboration avec le comité
technique du Comité européen de normalisation (CEN) CEN/TC 289, Cuir, dont le secrétariat est tenu
par l'UNI, conformément à l’accord de coopération technique entre l’ISO et le CEN (Accord de Vienne).
L’IULTCS est une organisation mondiale de sociétés professionnelles des industries du cuir fondée en
1897 ayant pour mission de favoriser l’avancement des sciences et technologies du cuir. L’IULTCS a trois
commissions, qui sont responsables de l’établissement des méthodes internationales d’échantillonnage
et d’essai des cuirs. L’ISO reconnaît l’IULTCS en tant qu’organisme international à activités normatives
pour l’élaboration de méthodes d’essai relatives au cuir.
Cette deuxième édition annule et remplace la première édition (ISO 17072-1:2011), qui a fait l’objet
d’une révision technique comme suit:
— le Domaine d’application et les Articles 5, 6, 7, 8.3, 9 et 10 ont fait l’objet de modifications éditoriales;
— 7.2 et 8.2 ont fait l’objet de modifications techniques. 7.2 fait référence à l’ISO 4044 pour la préparation
des échantillons, laquelle exige des utilisateurs de broyer des morceaux de cuir suffisamment larges
ou de découper de petits morceaux de cuir;
— les précédents paragraphes 6.3 et 7.3 de l’ISO 17072-1:2011 ont été supprimés.
Une liste de toutes les parties de la série ISO 17072 peut être trouvée sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www .iso .org/fr/members .html.
iv © ISO 2019 – Tous droits réservés

NORME INTERNATIONALE
IULTCS/IUC27-1:2019(F)
Cuir — Détermination chimique de la teneur en métal —
Partie 1:
Métaux extractibles
1 Domaine d’application
Le présent document spécifie une méthode de détermination des métaux extractibles du cuir
s’appuyant sur l’extraction à l’aide d’une solution de sueur artificielle acide suivie d’une détermination
par spectrométrie d’émission optique avec plasma à couplage inductif (ICP-OES), par spectrométrie de
masse avec plasma à couplage inductif (ICP-MS), par spectrométrie d’absorption atomique (AAS) ou
par spectrométrie de fluorescence atomique (SFA).
La présente méthode détermine les métaux extractibles présents dans le cuir. Elle n’est pas spécifique à
un composé ou à l’état d’oxydation des métaux. La présente méthode est particulièrement adaptée à la
détermination du chrome extractible dans les cuirs tannés au chrome.
La méthode s’applique également à la détermination de nombreux métaux extractibles, dont:
Aluminium (Al) Cuivre (Cu) Nickel (Ni)
Antimoine (Sb) Fer (Fe) Potassium (K)
Arsenic (As) Plomb (Pb) Sélénium (Se)
Baryum (Ba) Magnésium (Mg) Étain (Sn)
Cadmium (Cd) Manganèse (Mn) Titane (Ti)
Calcium (Ca) Mercure (Hg) Zinc (Zn)
Chrome (Cr) Molybdène (Mo) Zirconium (Zr)
Cobalt (Co)
Les résultats de l’essai interlaboratoires et les limites de quantification possibles avec l’ICP-OES sont
indiqués dans les Tableaux A.1 et A.2 de l’Annexe A.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s'applique (y compris les
éventuels amendements).
ISO 105-E04, Textiles — Essais de solidité des coloris — Partie E04: Solidité des coloris à la sueur
ISO 2418, Cuir — Essais chimiques, physiques, mécaniques et de solidité — Emplacement de l'échantillonnage
ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
ISO 4044, Cuir — Essais chimiques - Préparation des échantillons pour essais chimiques
ISO 4684, Cuir — Essais chimiques — Détermination des matières volatiles
ISO 11885, Qualité de l'eau — Dosage d'éléments choisis par spectroscopie d'émission optique avec plasma
induit par haute fréquence (ICP-OES)
IULTCS/IUC27-1:2019(F)
ISO 15586, Qualité de l'eau — Dosage des éléments traces par spectrométrie d'absorption atomique en four
graphite
ISO 17294-2, Qualité de l'eau — Application de la spectrométrie de masse avec plasma à couplage inductif
(ICP-MS) — Partie 2: Dosage des éléments sélectionnés y compris les isotopes d'uranium
ISO 17852, Qualité de l'eau — Dosage du mercure — Méthode par spectrométrie de fluorescence atomique
3 Termes et définitions
Aucun terme n’est défini dans le présent document.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https: //www .iso .org/obp;
— IEC Electropedia: disponible à l’adresse http: //www .electropedia .org/.
4 Principe
Un échantillon de cuir est placé pour extraction à (37 ± 2) °C pendant 4 h ± 5 min dans une solution de
sueur artificielle acide. La solution extraite est filtrée, acidifiée et analysée par ICP, SFA ou AAS.
Les résultats sont donnés par rapport à la matière sèche du cuir.
5 Réactifs
AVERTISSEMENT — Les acides concentrés utilisés dans la présente méthode sont des liquides
très corrosifs et/ou oxydants qui peuvent augmenter la possibilité d’incendie en cas de contact
avec des matériaux inflammables et attiser fortement un incendie existant, ou qui peuvent se
décomposer de manière explosive en chauffant. Ils peuvent également entraîner des risques
graves ou chroniques pour la santé. En outre, ils sont dangereux pour l’eau. Des mesures de
sécurité appropriées sont par conséquent nécessaires.
5.1 Généralités
Sauf indication contraire, seuls des produits chimiques de qualité analytique doivent être utilisés.
Toutes les solutions sont aqueuses.
5.2 Acide nitrique de concentration massique comprise entre 60 % et 70 %.
5.3 Monochlorohydrate de l-histidine monohydraté
5.4 Chlorure de sodium
5.5 Dihydrogénophosphate de sodium dihydraté
5.6 Hydroxyde de sodium, 0,1 mol/l.
5.7 Solutions mères des éléments des différents métaux, présentant des concentrations massiques
de 1 000 mg/l chacune.
5.8 Acide nitrique, 0,1 mol/l.
2 © ISO 2019 – Tous droits réservés

IULTCS/IUC27-1:2019(F)
5.9 Eau de qualité 3 conformément à l’ISO 3696.
5.10 Solution d’or (Au), dans de l’acide chlorhydrique ou du permanganate de potassium, 1 000 µg/l.
6 Appareillage et matériel
6.1 Généralités
L’ensemble de la verrerie, des dispositifs d’analyse et du matériel de laboratoire, filtres compris, doivent
être adaptés à l’analyse des métaux à l’état de trace.
Utiliser l’appareillage de laboratoire courant et, en particulier, ce qui suit.
6.2 Étuve de laboratoire pouvant être maintenue à (102 ± 2) °C.
6.3 Balance analytique d’une exactitude de 0,1 mg.
6.4 Balance de laboratoire d’une exactitude de 0,01
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.