Corrigendum 1 to Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of nerve and muscle stimulators

General Information

Status
Published
Publication Date
11-Feb-2002
Current Stage
DELPUB - Deleted Publication
Start Date
27-Jun-2012
Completion Date
13-Feb-2026

Relations

Effective Date
05-Sep-2023
Effective Date
05-Sep-2023
Standard

IEC 60601-2-10:1987/AMD1:2001/COR1:2002 - Corrigendum 1 to Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of nerve and muscle stimulators Released:2/12/2002

English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 60601-2-10:1987/AMD1:2001/COR1:2002 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 to Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of nerve and muscle stimulators". This standard covers: Corrigendum 1 to Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of nerve and muscle stimulators

Corrigendum 1 to Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of nerve and muscle stimulators

IEC 60601-2-10:1987/AMD1:2001/COR1:2002 is classified under the following ICS (International Classification for Standards) categories: 11.040.60 - Therapy equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60601-2-10:1987/AMD1:2001/COR1:2002 has the following relationships with other standards: It is inter standard links to IEC 60601-2-10:1987/AMD1:2001, IEC 60601-2-10:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 60601-2-10:1987/AMD1:2001/COR1:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 60601-2-10 amend. 1
(First edition – 1987)
Medical electrical equipment –
Part 2-10: Particular requirements for the
safety of nerve and muscle stimulators
Amendment 1
CORRIGENDUM 1
Page 7
42 Excessive temperatures
Replace the existing Clause 42 as follows:
42 Excessive temperatures
This clause of the General Standard applies except as follows:
Amend the
...