Primary batteries –
Part 3: Watch batteries
C O R R I G E N D U M 1
Table 11 – Leakage levels and classification
Replace, in Table 11, the heading “Diagramme”, by
“Diagram”
Annex A – Designation
Replace the existing annex by the following new annex:
Annex A
(normative)
Designation
Watch batteries manufactured with the express purpose of complying with this standard
should be designated by a system of coded letters and numbers as shown below. However,
the letter W is used to i
...
This May Also Interest You
- Standard2 pagesEnglish and French languagesale 15% off
IEC 60086-3:2021 is available as IEC 60086-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3-5:2021 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.
The contents of the corrigendum of June 2023 have been included in this copy.
- Standard24 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish languagesale 15% off
- Standard49 pagesEnglish and French languagesale 15% off
IEC 60086-3:2016 is available as IEC 60086-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3:2016 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- A harmonization of the cell sizes and service output tests with IEC 60086-2;
- Clarifications of Clauses 6: Sampling and Quality Assurance, 7: Test methods, and 8: Visual examination and acceptance condition;
- Harmonization of temperature and humidity conditions with IEC 60086-1. This publication is published as a double logo standard. Keywords: primary batteries for watches
- Standard77 pagesEnglish languagesale 15% off
- Standard50 pagesEnglish and French languagesale 15% off
IEC 60086-3:2011 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. This third edition cancels and replaces the second edition (2004) and constitutes a technical revision. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard. The contents of the corrigendum of September 2011 have been included in this copy. This bilingual version (2014-01) corresponds to the monolingual English version, published in 2011-01. Keywords: requirements and information for primary watch batteries.
- Standard26 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish and French languagesale 15% off
This part of IEC 60086 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a list of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer should specify which test method was used.
- Standard24 pagesEnglish languagesale 15% off
- Standard24 pagesFrench languagesale 15% off
- Standard47 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
IEC 60086-3:2021 is available as IEC 60086-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3-5:2021 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.
The contents of the corrigendum of June 2023 have been included in this copy.
- Standard24 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish languagesale 15% off
- Standard49 pagesEnglish and French languagesale 15% off
IEC 60086-3:2016 is available as IEC 60086-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3:2016 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- A harmonization of the cell sizes and service output tests with IEC 60086-2;
- Clarifications of Clauses 6: Sampling and Quality Assurance, 7: Test methods, and 8: Visual examination and acceptance condition;
- Harmonization of temperature and humidity conditions with IEC 60086-1. This publication is published as a double logo standard. Keywords: primary batteries for watches
- Standard77 pagesEnglish languagesale 15% off
- Standard50 pagesEnglish and French languagesale 15% off
IEC 60086-3:2011 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. This third edition cancels and replaces the second edition (2004) and constitutes a technical revision. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard. The contents of the corrigendum of September 2011 have been included in this copy. This bilingual version (2014-01) corresponds to the monolingual English version, published in 2011-01. Keywords: requirements and information for primary watch batteries.
- Standard26 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish and French languagesale 15% off
This part of IEC 60086 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a list of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer should specify which test method was used.
- Standard24 pagesEnglish languagesale 15% off
- Standard24 pagesFrench languagesale 15% off
- Standard47 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.