Amendment 1 - Household and similar electrical appliances - Safety - Part 2-69: Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use

Amendement 1 - Appareils électrodomestiques et analogues - Sécurité - Partie 2-69: Règles particulières pour les aspirateurs fonctionnant en présence d'eau ou à sec, y compris les brosses motorisées, à usage industriel et commercial

General Information

Status
Published
Publication Date
02-Nov-2004
Current Stage
DELPUB - Deleted Publication
Completion Date
22-Feb-2012
Ref Project

Relations

Buy Standard

Standard
IEC 60335-2-69:2002/AMD1:2004 - Amendment 1 - Household and similar electrical appliances - Safety - Part 2-69: Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use Released:11/3/2004 Isbn:2831876567
English language
30 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 60335-2-69:2002/AMD1:2004 - Amendment 1 - Household and similar electrical appliances - Safety - Part 2-69: Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use Released:11/3/2004 Isbn:2831883180
English and French language
61 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL IEC
STANDARD 60335-2-69
AMENDMENT 1
2004-11
Amendment 1
Household and similar electrical appliances –
Safety –
Part 2-69:
Particular requirements for wet and dry
vacuum cleaners, including power brush,
for industrial and commercial use

 IEC 2004 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale U

International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue

– 2 – 60335-2-69 Amend. 1  IEC:2004(E)

FOREWORD
This amendment has been prepared by subcommittee 61J: Electrical motor-operated cleaning

appliances for industrial use, of IEC technical committee 61: Safety of household and similar

electrical appliances.
The text of this amendment is based on the following documents:

FDIS Report on voting
61J/169/FDIS 61J/172/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
___________
CONTENTS
Add the titles of the new Annexes CC and DD as follows:
Annex CC (normative) Particular requirements for vacuum cleaners, suction sweeping
machines and dust extractors for the collection of dusts which are an explosion risk
Annex DD (normative) Particular requirements for vacuum cleaners for use in ESD protected
areas
Add the titles of the following new figures:
Figure 102 – Apparatus for testing the abrasion resistance of current-carrying hoses
Figure 103 – Apparatus for testing the resistance to flexing of current-carrying hoses

Figure 104 – Configuration of the hose for the freezing treatment
Figure 105 – Flexing positions for the hose after removal from the freezing cabinet
Figure AA.2 – Test method for essential filter material
Figure AA.3 – In situ essential filter element test
Figure AA.4 – Assembled appliance test
Figure CC.1 – Marking – Type 22 vacuum cleaners and suction sweeping machines
Figure CC.2 – Marking – Type 22 dust extractor
Replace the title of Table AA.1 as follows:
Table AA.1 – Penetration limits

60335-2-69 Amend. 1  IEC:2004(E) – 3 –

FOREWORD
Add the following new item to the list of differences existing in some countries:

– 7.12: No requirements for sound marking exist (USA)

2  Normative references
Add the following new references:
IEC 60704-2-1, Household and similar electrical appliances – Test code for the determination
of airborne acoustical noise – Part 2-1: Particular requirements for vacuum cleaners
IEC 61241-1-1, Electrical apparatus for use in the presence of combustible dust – Part 1-1:
Electrical apparatus protected by enclosures and surface temperature limitation –
Specification for apparatus
IEC 61241-10:2004, Electrical apparatus for use in the presence of combustible dust –
Part 10: Classification of areas where combustible dusts are or may be present
ISO 2602, Ergonomics – Danger signals for public and work areas – Auditory danger signals
ISO 6344-2, Coated abrasives – Grain size analysis – Part 2: Determination of grain size
distribution of macrogrits P12 to P220
ISO 7731, Safety of machinery; Auditory danger signals; General requirements, design and
testing
ISO 11428, Ergonomics – Visual danger signals – General requirements, design and testing
3  Definitions
Add the following new definitions:
3.102
water-suction cleaning appliance
appliance for aspirating an aqueous solution that may contain foaming detergent

3.103
motorized cleaning head
accessory containing a motor that is supplied from the appliance and which is attached to the
end of a hand-held hose or tube
NOTE The main cleaning head permanently attached is not regarded as a motorized cleaning head.
6 Classification
6.1 Replace the existing second paragraph of this subclause with the following:
Metal parts that may continuously contact the body shall be considered as handles for which
22.36 applies.
– 4 – 60335-2-69 Amend. 1  IEC:2004(E)

7 Marking and instructions
7.1 Delete this subclause.
Add the following subclause:
7.6 Addition:
[symbol IEC 60417-5935 (DB:2000-10] motorized cleaning head for

water-suction cleaning
7.12 Replace the existing text of the addition by the following:
The front cover of the instruction manual shall include the substance of the following:
CAUTION Read the instruction manual before using the appliance.
This wording may be replaced by symbols ISO 7000-0434A/B and ISO 7000-1641
(DB:2004:01). If these symbols are used, their meaning is to be explained in the instructions
for use.
The instruction manual shall include the substance of the following warnings, as applicable.
– CAUTION  This appliance is not suitable for picking up hazardous dust.
– CAUTION  This appliance is for dry use only and is not to be used or stored outdoors in
wet conditions.
– WARNING  Only use the brushes provided with the appliance or those specified in the
instruction manual. The use of other brushes may impair safety.
The instruction manual shall give details regarding the following, as applicable:
– the precautions to be taken when using the appliance under specific conditions such as
handling flammable liquids or dust and dust hazardous to health;
– a statement that the appliance is to be disconnected from its power source during cleaning
or maintenance, and that when replacing parts or converting the appliance to another
function:
• for mains operated appliances, the plug is to be removed from the socket-outlet;

• for battery operated appliances, the key of the supply switch is to be removed or an
equivalent disconnection is to be made;
– the intended use of brushes which are specified for the appliance.
The instruction manual shall state the A-weighted sound pressure level L in dB(A) emitted
PA
by the appliance. If the A-weighted sound pressure level exceeds 85 dB(A), it shall also state
the sound power level L in dB(A) and that appropriate ear protection has to be used (the
WA
sound level is measured in accordance with IEC 60704-2-1).
The instruction manual shall include the substance of the following.
This appliance is suitable for commercial use, for example in hotels, schools, hospitals,
factories, shops, offices and rental businesses.

60335-2-69 Amend. 1  IEC:2004(E) – 5 –

The instruction manual for mains operated appliances shall include the substance of the
following:
– do not allow the rotating brushes to come into contact with the supply cord;

– regularly examine the supply cord for damage, such as cracking or ageing. If damage is

found, replace the cord before further use;

– only replace the supply cord with the type specified in the instruction manual;

– only use the socket outlet on the appliance for purposes specified in the instruction

manual.
For wet suction appliances, the instruction manual shall state the substance of the following:
– CAUTION  If foam or liquid escapes from the appliance, switch off immediately.
– regularly clean the water level limiting device in accordance with the instructions and
examine it for signs of damage.
The instructions for appliances having a current-carrying hose operating at other than safety
extra-low voltage shall include the substance of the following:
CAUTION: This hose contains electrical connections:
– do not use to collect water;
– do not immerse in water for cleaning;
– the hose should be checked regularly and shall not be used if damaged.
If symbol IEC 60417-5935 is used, its meaning shall be explained.
Add the following subclauses:
7.14 Addition:
The height of symbol IEC 60417-5935 shall be at least 15 mm.
Compliance is checked by measurement.
7.101 Motorized cleaning heads shall be marked with
– rated voltage or rated voltage range in volts;
– rated power input in watts;
– name, trade mark or identification mark of the manufacturer or responsible vendor;

– model or type reference.
Motorized cleaning heads for water-suction cleaning appliances, except those of class III
construction having a working voltage up to 24 V shall be marked with symbol IEC 60417-
5935.
NOTE This symbol is an information sign and, except for the colours, the rules of ISO 3864 apply.
Compliance is checked by inspection.
7.102 Appliance outlets for accessories shall be marked with the maximum load in watts.
NOTE This marking may be on the appliance close to the appliance outlet.
Compliance is checked by inspection.

– 6 – 60335-2-69 Amend. 1  IEC:2004(E)

10 Power input and current
Add the following subclause:
10.1 Addition:
The power input of motorized cleaning heads is measured separately.

15 Moisture resistance
15.2 Replace the text after note 101 by the following:
Nozzles and motorized cleaning heads of water-suction cleaning appliances are placed in
a container, the base of which is level with the surface supporting the appliance. The
container is filled with a detergent solution to a level of 5 mm above its base, this level being
maintained throughout the test.
The solution consists of 20 g of NaCl and 1 ml of a solution of 28 % by mass of dodecyl
sodium sulphate in each 8 l of water.
The appliance is operated until its liquid container is completely full and for a further 5 min.
NOTE 102 The solution should be stored in a cool atmosphere and used within seven days of its preparation.
NOTE 103 The chemical designation of dodecyl sodium sulphate is C12H25NaSO4.
NOTE 104 If it is not possible to overfill the container for soiled liquid owing to the construction of the appliance,
the test specified in 19.101 is considered to be adequate.
After each of these tests, the appliance shall withstand the electric strength test of 16.3.
Inspection shall show that there is no trace of liquid on insulation that could result in a
reduction of clearances or creepage distances below the values specified in Clause 29.
NOTE 105 The appliance is allowed to stand in normal test room atmosphere for 24h before being subjected to
the test of 15.3
Add the following subclause:
15.101 Motorized cleaning heads of water suction cleaning appliances shall be resistant
to liquids that may come into contact with them.
Compliance is checked by the following tests.

The motorized cleaning head is subjected to an impact test as described in IEC 60068-2-75,
the value of the impact being 2 J. The motorized cleaning head is rigidly supported and
three blows are applied to every point of the enclosure that is likely to be weak.
It is then subjected to the free fall test procedure 1 of IEC 60068-2-32. It is dropped 4 000
times from a height of 100 mm onto a steel plate having a thickness of not less than 15 mm. It
is dropped
– 1000 times on its right side;
– 1000 times on its left side;
– 1000 times on its front face;
– 1000 times on its cleaning surface.

60335-2-69 Amend. 1  IEC:2004(E) – 7 –

The motorized cleaning head is then subjected to the test described in 14.2.7 of IEC 60529,
the water containing approximately 1 % NaCl.

The motorized cleaning head shall then withstand the electric strength test of 16.3, the
voltage being applied between the live parts and the solution, and inspection shall show that

there is no trace of saline solution on insulation which could result in a reduction of

clearances and creepage distances below the values specified in Clause 29.

NOTE The test is not carried out on motorized cleaning heads of class III construction having a working
voltage up to 24 V.
16 Leakage current and electric strength
Add the following subclause:
16.3 Addition:
Current-carrying hoses, except for their electrical connections, are immersed for 1 h in water
containing approximately 1 % NaCl, at a temperature of 20 °C ± 5 °C. While the hose is still
immersed, a voltage of 2 000 V is applied for 5 min between each conductor and all the other
conductors connected together. A voltage of 3 000 V is then applied for 1 min between all the
conductors and the saline solution.
19 Abnormal operation
19.1 Add the following new paragraph:
The test of 19.7 is only carried out on motorized cleaning heads.
19.7 Replace the existing text with the following:
Motorized cleaning heads are tested with the rotating brush or similar device locked for
30 s.
20 Stability and mechanical hazards
Add the following subclauses:
20.1 Addition:
NOTE 101 Motorized cleaning heads are not subjected to this test.
20.101 Shaft ends and similar rotating parts shall be protected if they protrude by more than
a quarter of their diameter, unless the end is rounded and less than 50 mm in length.
Injury due to unintentional closing or slamming of parts, such as movable side walls and
covers, shall be prevented.
Wheels or rollers for the transport of appliances heavier than 20 kg shall be located or
protected so that injury to the feet of the operator is prevented.
Compliance is checked by inspection, by measurement and by manual test.

– 8 – 60335-2-69 Amend. 1  IEC:2004(E)

21 Mechanical strength
Add the following new subclauses:

21.102 Current-carrying hoses shall be resistant to crushing.

Compliance is checked by the following test.

The hose is placed between two parallel steel plates each having a length of 100 mm, a width
of 50 mm and the edges of the longer sides rounded with a radius of 1 mm. The axis of the

hose is positioned at right angles to the longer sides of the plates. The plates are placed at a

distance of approximately 350 mm from one end of the hose.
The steel plates are pressed together at a rate of
...


IEC 60335-2-69
Edition 3.0 2004-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 2-69: Particular requirements for wet and dry vacuum cleaners, including
power brush, for industrial and commercial use

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-69: Règles particulières pour les aspirateurs fonctionnant en présence
d’eau ou à sec, y compris les brosses motorisées, à usage industriel et
commercial
IEC 60335-2-69:2002/A1:2004
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60335-2-69
Edition 3.0 2004-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Household and similar electrical appliances – Safety –
Part 2-69: Particular requirements for wet and dry vacuum cleaners, including
power brush, for industrial and commercial use

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-69: Règles particulières pour les aspirateurs fonctionnant en présence
d’eau ou à sec, y compris les brosses motorisées, à usage industriel et
commercial
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
V
CODE PRIX
ICS 97.080 ISBN 2-8318-8318-0
– 2 – 60335-2-69 Amend. 1 © CEI:2004
AVANT-PROPOS
Cet amendement a été établi par le sous-comité 61J: Appareils électriques à moteur de
nettoyage pour usage industriel, du comité d'études 61 de la CEI: Sécurité des appareils
électrodomestiques et analogues.
Cette version bilingue, publiée en 2005-12, correspond à la version anglaise.
Le texte anglais de cet amendement est issu des documents 61J/169/FDIS et 61J/172/RVD. Le
rapport de vote 61J/172/RVD donne toute information sur le vote ayant abouti à l’approbation
de cet amendement.
La version française de cet amendement n’a pas été soumise au vote.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
«http://webstore.iec.ch» dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
___________
SOMMAIRE
Ajouter les titres des nouvelles Annexes CC et DD comme indiqué ci-dessous:
Annexe CC (normative) Exigences particulières pour les aspirateurs, les balayeuses à
aspiration et les extracteurs de poussières destinés au ramassage des poussières qui
présentent un risque d’explosion
Annexe DD (normative) Exigences particulières pour les aspirateurs qui sont utilisés en zone
protégée contre les décharges électrostatiques
Ajouter les titres des nouvelles figures, comme indiqué ci-dessous:
Figure 102 – Appareillage pour les essais de résistance à l’abrasion des flexibles conducteurs
Figure 103 – Appareil pour l'essai de la résistance à la flexion des tuyaux parcourus par le courant
Figure 104 – Configuration du flexible pour le traitement à basse température
Figure 105 – Positions de flexion pour le tuyau après retrait de l’armoire de congélation
Figure AA.2 – Méthode d'essai pour le matériau du filtre principal
Figure AA.3 – Essai in situ de l'élément du filtre principal
Figure AA.4 – Essai de l'appareil assemblé
Figure CC.1 – Marquage – Aspirateurs de Type 22 et balayeuses à aspiration
Figure CC.2 – Marquage – Extracteur de poussières de Type 22
Remplacer le titre du Tableau AA.1 comme suit:
Tableau AA.1 – Limites de pénétration

60335-2-69 Amend. 1 © IEC:2004 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 61J: Electrical motor-operated cleaning
appliances for industrial use, of IEC technical committee 61: Safety of household and similar
electrical appliances.
This bilingual version, published in 2005-12, corresponds to the English version.
The text of this amendment is based on the following documents:
FDIS Report on voting
61J/169/FDIS 61J/172/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The French version of this amendment has not been voted upon.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
___________
CONTENTS
Add the titles of the new Annexes CC and DD as follows:
Annex CC (normative) Particular requirements for vacuum cleaners, suction sweeping
machines and dust extractors for the collection of dusts which are an explosion risk
Annex DD (normative) Particular requirements for vacuum cleaners for use in ESD protected
areas
Add the titles of the following new figures:
Figure 102 – Apparatus for testing the abrasion resistance of current-carrying hoses
Figure 103 – Apparatus for testing the resistance to flexing of current-carrying hoses
Figure 104 – Configuration of the hose for the freezing treatment
Figure 105 – Flexing positions for the hose after removal from the freezing cabinet
Figure AA.2 – Test method for essential filter material
Figure AA.3 – In situ essential filter element test
Figure AA.4 – Assembled appliance test
Figure CC.1 – Marking – Type 22 vacuum cleaners and suction sweeping machines
Figure CC.2 – Marking – Type 22 dust extractor
Replace the title of Table AA.1 as follows:
Table AA.1 – Penetration limits

– 4 – 60335-2-69 Amend. 1 © CEI:2004
AVANT-PROPOS
Ajouter à la liste des différences existant dans les pays le nouveau point suivant:
– 7.12: Il n’existe pas d’exigence relative au marquage du niveau acoustique (USA)
2 Références normatives
Ajouter à la liste existante les nouvelles références ci-dessous:
CEI 60704-2-1, Appareils électrodomestiques et analogues – Code d'essai pour la détermi-
nation du bruit aérien – Partie 2-1: Règles particulières pour les aspirateurs de poussière
CEI 61241-1-1, Matériels électriques destinés à être utilisés en présence de poussières
combustibles – Partie 1: Appareils électriques protégés par enveloppes et limitation de la
température de surface – Section 1: Spécification pour les matériels
CEI 61241-10:2004, Matériels électriques pour utilisation en présence de poussières
combustibles – Partie 10: Classification des emplacements où des poussières combustibles
sont ou peuvent être présentes
ISO 2602, Interprétation statistique de résultats d’essais – Estimation de la moyenne –
Intervalle de confiance
ISO 6344-2, Abrasifs appliqués – Granulométrie – Partie 2: Détermination de la distribution
granulométrique des macrograins P12 à P220
ISO 7731, Ergonomie – Signaux de danger pour lieux publics et lieux de travail – Signaux de
danger auditifs
ISO 11428, Ergonomie – Signaux visuels de danger – Exigences générales, conception et
essais
3 Définitions
Ajouter les nouvelles définitions suivantes.
3.102
appareil de nettoyage à aspiration d'eau
appareil prévu pour aspirer une solution aqueuse qui peut contenir de la mousse de détergent
3.103
tête de nettoyage à moteur
accessoire contenant un moteur qui est alimenté à partir de l'appareil et qui est attaché à
l'extrémité d'un tuyau ou d'un tube manuel
NOTE La tête de nettoyage principale fixée de façon permanente n’est pas considérée comme une tête de
nettoyage à moteur.
6 Classification
6.1 Remplacer le second alinéa de ce paragraphe par ce qui suit:
Les parties métalliques qui peuvent être en contact continu avec le corps doivent être
considérées comme des poignées pour lesquelles le 22.36 s’applique.

60335-2-69 Amend. 1 © IEC:2004 – 5 –
FOREWORD
Add the following new item to the list of differences existing in some countries:
– 7.12: No requirements for sound marking exist (USA)
2 Normative references
Add the following new references:
IEC 60704-2-1, Household and similar electrical appliances – Test code for the determination
of airborne acoustical noise – Part 2-1: Particular requirements for vacuum cleaners
IEC 61241-1-1, Electrical apparatus for use in the presence of combustible dust – Part 1-1:
Electrical apparatus protected by enclosures and surface temperature limitation –
Specification for apparatus
IEC 61241-10:2004, Electrical apparatus for use in the presence of combustible dust –
Part 10: Classification of areas where combustible dusts are or may be present
ISO 2602, Ergonomics – Danger signals for public and work areas – Auditory danger signals
ISO 6344-2, Coated abrasives – Grain size analysis – Part 2: Determination of grain size
distribution of macrogrits P12 to P220
ISO 7731, Safety of machinery; Auditory danger signals; General requirements, design and
testing
ISO 11428, Ergonomics – Visual danger signals – General requirements, design and testing
3 Definitions
Add the following new definitions:
3.102
water-suction cleaning appliance
appliance for aspirating an aqueous solution that may contain foaming detergent
3.103
motorized cleaning head
accessory containing a motor that is supplied from the appliance and which is attached to the
end of a hand-held hose or tube
NOTE The main cleaning head permanently attached is not regarded as a motorized cleaning head.
6 Classification
6.1 Replace the existing second paragraph of this subclause with the following:
Metal parts that may continuously contact the body shall be considered as handles for which
22.36 applies.
– 6 – 60335-2-69 Amend. 1 © CEI:2004
7 Marquage et instructions
L’article de la Partie 1 est applicable avec l’exception suivante.
7.1 Supprimer ce paragraphe.
Ajouter le paragraphe ci-dessous.
7.6 Addition:
[symbole CEI 60417-5935 (DB:2000-10] tête de nettoyage motorisée pour
nettoyage à aspiration d'eau
7.12 Remplacer le texte existant de l’addition par ce qui suit:
La première page de l
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.