IEC 61076-2-101:2012
(Main)Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking
Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking
IEC 61076-2-101:2012 describes M12 circular connectors typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable, with screw-locking. The connectors with glass to metal seal are fixed connectors only which consist of fixed glass to metal sealed styles with rewireable male contacts and are intermateable with corresponding free connectors according to this International Standard. Male connectors have round contacts 0,6 mm, 0,76 mm, 0,8 mm and 1,0 mm. The different codings prevent the mating of these coded male or female connectors to any other interfaces and cross-mating between the different codings. This third edition cancels and replaces the second edition published in 2008 and its corrigendum published in 2010. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The drawings of some styles have been corrected,
- A new style with maximum 17 poles, with A-coding, has been added, as new applications for the industrial process measurement and control require a high number of poles in M12 circular connectors. The existing styles and dimensions which were specified in IEC 61076-2-101 Ed.2 are further applicable for the added interface dimension of the 17 poles versions,
- Removal of the type designation and ordering information, former Tables 6 and 7 have been updated accordingly and
- Inclusion of the technical content of IEC PAS 61076-2-108, which will be withdrawn after publication of this International Standard. The drawings have been updated and correction to the title of Figure 9 was made. Keywords: M12 connectors, Circular connector
Connecteurs pour équipements électroniques - Exigences de produit - Partie 2-101: Connecteurs circulaires - Spécification particulière pour les connecteurs M12 à vis
La CEI 61076-2-101:2012 décrit les connecteurs circulaires M12 qui sont généralement utilisés pour les mesures et les commandes dans les processus industriels. Ces connecteurs se composent d'embases et de fiches, démontables ou non et sont équipés d'un système à vis. Les connecteurs à joints verre-métal sont uniquement des embases constituées de modèles à joints verre-métal avec contacts mâles démontables et qui sont accouplables aux fiches correspondantes conformes à la présente Norme Internationale. Les connecteurs mâles possèdent des contacts arrondis de 0,6 mm, 0,76 mm, 0,8 mm et 1,0 mm. Les différents codages empêchent l'accouplement de ces connecteurs codés mâles ou femelles avec toute autre interface ainsi que l'accouplement croisé entre les différents codages. Cette troisième édition annule et remplace la deuxième édition parue en 2008 et son corrigendum paru en 2010. Elle constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:
- Les dessins de certains modèles ont été corrigés, Un nouveau modèle avec 17 pôles au maximum et un codage A, a été ajouté, car les nouvelles applications pour les dispositifs de mesure et de commande dans les processus industriels exigent un nombre élevé de pôles dans les connecteurs circulaires M12. Les modèles et les dimensions qui existent et qui étaient spécifiés dans la CEI 61076-2-101 Ed.2 sont toujours applicables pour la dimension d'interface ajoutée des versions à 17 pôles,
- Suppression de la désignation de type et des renseignements pour les commandes, les anciens Tableaux 6 et 7 ont été mis à jour en conséquence,
- Ajout du contenu technique de la CEI/PAS 61076-2-108, qui sera annulée après publication de la présente Norme Internationale. Les dessins ont été mis à jour et le titre de la Figure 9 a été corrigé. Mots clé: connecteurs M12, connecteurs circulaires.
General Information
Relations
Standards Content (Sample)
IEC 61076-2-101 ®
Edition 3.0 2012-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 2-101: Circular connectors – Detail specification for M12 connectors
with screw-locking
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 2-101: Connecteurs circulaires – Spécification particulière pour les
connecteurs M12 à vis
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les
microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.
IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Liens utiles:
Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.
IEC 61076-2-101 ®
Edition 3.0 2012-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 2-101: Circular connectors – Detail specification for M12 connectors
with screw-locking
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 2-101: Connecteurs circulaires – Spécification particulière pour les
connecteurs M12 à vis
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
XA
CODE PRIX
ICS 31.220.10 ISBN 978-2-8322-0058-2
– 2 – 61076-2-101 © IEC:2012
CONTENTS
FOREWORD . 5
1 Scope . 8
2 Normative references . 8
3 Technical information . 9
3.1 Terms and definitions . 9
3.2 Recommended method of termination . 9
3.2.1 General . 9
3.2.2 Number of contacts or contact cavities . 10
3.3 Ratings and characteristics . 10
3.4 Marking . 10
3.5 Safety aspects. 10
4 Dimensional information . 11
4.1 General . 11
4.2 Survey of styles and variants . 11
4.2.1 Fixed connectors . 11
4.2.2 Free connectors . 22
4.3 Interface dimensions . 27
4.3.1 Pin front view A-coding . 27
4.3.2 Pin front view B-coding . 32
4.3.3 Pin front view C-coding . 33
4.3.4 Pin front view D-coding . 36
4.3.5 Pin front view P-coding . 37
4.4 Engagement (mating) information . 38
4.5 Gauges . 40
5 Characteristics . 41
5.1 Climatic category . 41
5.2 Electrical characteristics . 41
5.2.1 Rated voltage – Rated impulse voltage – Pollution degree . 41
5.2.2 Voltage proof . 42
5.2.3 Current-carrying capacity. 43
5.2.4 Contact resistance . 43
5.2.5 Insulation resistance . 44
5.3 Mechanical characteristics . 44
5.3.1 IP degree of protection . 44
5.3.2 Mechanical operation . 44
5.3.3 Insertion and withdrawal forces . 44
5.3.4 Contact retention in insert . 44
5.3.5 Polarizing method . 45
5.3.6 Vibration (sinusoidal) . 45
5.3.7 Pressure differential . 45
6 Test schedule . 45
6.1 General . 45
6.2 Arrangement for contact resistance measurements . 46
6.3 Arrangement for dynamic stress tests (vibration) . 46
6.4 Test schedule . 48
61076-2-101 © IEC:2012 – 3 –
6.4.1 Test group P – Preliminary . 48
6.4.2 Test group AP – Dynamic/ Climatic . 49
6.4.3 Test group BP – Mechanical endurance . 52
6.4.4 Test group CP – Electrical load . 54
6.4.5 Test group DP – Chemical resistivity . 55
6.4.6 Test group EP – Connection method tests . 55
6.4.7 Test group FP – Electrical transmission requirements . 56
Annex A (informative) Diameter of the female connector body . 57
Annex B (informative) Steel conduit thread, sizes . 58
Figure 1 – Tube insert, male contacts, mounting without thread (thread on tube) . 12
Figure 2 – Tube insert, male contacts, mounting with thread M12 × 1 . 12
Figure 3 – Fixed connector, male contacts, mounting with thread M12 × 1, square
flange front mounting . 13
Figure 4 – Fixed connector, male contacts, mounting with thread M12 × 1, with wire
ends, single hole mounting thread M16 × 1,5 . 14
Figure 5 – Fixed connector, male contacts, mounting with thread M12 × 1, with wire
ends, single hole mounting thread M20 × 1,5 . 14
Figure 6 – Fixed connector, male contacts, mounting with thread M12 × 1 with wire
ends, single hole mounting thread M16 × 1,5, mounting orientation . 15
Figure 7 – Fixed connector, male contacts, mounting with thread M12 × 1, with wire
ends, single hole mounting thread M20 × 1,5, mounting orientation . 15
Figure 8 – Fixed connector, glass to metal seal, square flange front mounting, male
contacts . 16
Figure 9 – Fixed connector, glass to metal seal, single hole front mounting, male
contacts . 17
Figure 10 – Fixed connector, glass to metal seal, jam nut rear mounting, male
contacts . 18
Figure 11 – Fixed connector, glass to metal seal, through flange mounting, male
contacts . 19
Figure 12 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire
ends, single hole mounting thread M16 × 1,5 . 19
Figure 13 – Fixed connector, female contacts, mounting with thread M12 × 1, with wire
ends, single hole mounting thread M20 × 1,5 . 20
Figure 14 – Fixed connector, female contacts, mounting with thread
...
Questions, Comments and Discussion