IEC 60861:2006
(Main)Equipment for monitoring of radionuclides in liquid effluents and surface waters
Equipment for monitoring of radionuclides in liquid effluents and surface waters
Defines technical requirements for equipment for monitoring of alpha-, beta- or gamma-emitting radionuclides in liquid effluents and surface waters, provides general guidance as to the possible detection capability of such equipment and indicates when and where its uses may be practicable.
Equipements pour la surveillance des radionucléides dans les effluents liquides et les eaux de surface
Définit les exigences techniques pour les appareils de surveillance des radionucléides émetteurs alpha, bêta ou gamma dans les effluents liquides et dans les eaux de surface. Donne des directives générales sur les aptitudes de tels équipements et indique où et quand ils peuvent être utilisés.
General Information
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2006-08
Equipements pour la surveillance
des radionucléides dans les effluents liquides
et les eaux de surface
Equipment for monitoring of radionuclides
in liquid effluents and surface waters
Numéro de référence
Reference number
CEI/IEC 60861:2006
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2006-08
Equipements pour la surveillance
des radionucléides dans les effluents liquides
et les eaux de surface
Equipment for monitoring of radionuclides
in liquid effluents and surface waters
IEC 2006 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
X
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60861 CEI:2006
SOMMAIRE
AVANT-PROPOS.6
1 Domaine d'application.10
2 Références normatives.12
3 Termes et définitions .14
4 Classification des appareils .24
5 Conception de l'équipement .24
5.1 Caractéristiques de mesure et de l'affichage .24
5.2 Fiabilité.26
5.3 Equipement d'échantillonnage.26
5.4 Ensemble de détection .28
5.5 Ensemble de contrôle.30
5.6 Ensemble de mesure.30
5.7 Ensemble d’alarme.30
5.8 Dispositifs d'affichage .32
5.9 Moyens d'essai en fonctionnement .32
5.10 Installation et moyens de maintenance .32
5.11 Dispositifs de protection du rayonnement ionisant ambiant.34
5.12 Sécurité de l'utilisateur .34
5.13 Compatibilité électromagnétique.34
5.14 Alimentation électrique .36
6 Procédures d'essai.36
6.1 Généralités.36
6.2 Essais réalisés dans les conditions normales d'essai .36
6.3 Essais réalisés avec une variation des grandeurs d'influence.38
6.4 Caractéristiques métrologiques.38
6.5 Sources d'essai.38
7 Essais des performances sous rayonnement .40
7.1 Réponse de référence.40
7.2 Sensibilité et réponse relative de l'équipement pour une source solide.42
7.3 Linéarité.42
7.4 Justesse de l’équipement .44
7.5 Reproductibilité des résultats de mesure .46
7.6 Temps de réponse.46
7.7 Uniformité des écran de protection du détecteur bêta.48
7.8 Essais de surexposition.50
7.9 Réponse à d'autres radionucléides artificiels .50
7.10 Réponse aux descendants du Rn dissous dans l'eau .50
7.11 Réponse au rayonnement gamma ambiant .52
7.12 Influence des matériaux en suspension dans le liquide sur la mesure de
l'activité.54
8 Essais de performance du circuit hydraulique.56
8.1 Généralité .56
8.2 Stabilité du débit .56
8.3 Efficacité du nettoyage.56
60861 IEC:2006 – 3 –
CONTENTS
FOREWORD.7
1 Scope.11
2 Normative references .13
3 Terms and definitions .15
4 Classification of equipment.25
5 Equipment design.25
5.1 Measurement and indication characteristics .25
5.2 Reliability .27
5.3 Sampling assembly .27
5.4 Detection assembly .29
5.5 Control assembly.31
5.6 Measurement assembly.31
5.7 Alarm assembly.31
5.8 Indication facilities.33
5.9 Facilities for operational testing.33
5.10 Installation and maintenance facilities .33
5.11 Ambient ionizing radiation protection devices .35
5.12 User safety.35
5.13 Electromagnetic compatibility .35
5.14 Power supply.37
6 Test procedures .37
6.1 General .37
6.2 Tests performed under standard test conditions .37
6.3 Tests performed with variation of influence quantities.39
6.4 Metrological characteristics .39
6.5 Test sources .39
7 Radiation performance tests .41
7.1 Reference response .41
7.2 Sensitivity and relative response of the equipment for a solid source .43
7.3 Linearity .43
7.4 Repeatability of the equipment .45
7.5 Reproducibility of results of measurements .47
7.6 Response time .47
7.7 Uniformity of the protective screens for the beta detector .49
7.8 Overload test.51
7.9 Response to other artificial radionuclides .51
7.10 Response to Rn progeny dissolved in water.51
7.11 Response to ambient gamma radiation.53
7.12 Influence of materials in suspension in liquid on activity measurement .55
8 Liquid circuit performance tests .57
8.1 General .57
8.2 Flow-rate stability .57
8.3 Cleaning efficiency .57
– 4 – 60861 CEI:2006
9 Essais de performances électriques .58
9.1 Temps de préchauffage – ensembles de détection et de mesure.58
9.2 Variation de l’alimentation électrique .58
9.3 Variations transitoires de l’alimentation électrique .60
9.4 Stabilité du déclenchement d’alarme .60
9.5 Gamme de déclenchement de l’alarme.60
9.6 Alarme de défaut.62
10 Essais de performances environnementales .62
10.1 Température ambiante.62
10.2 Humidité relative.64
10.3 Immunité électromagnétique externe et décharge électrostatique.64
10.4 Emission électromagnétique.64
11 Rapport d’essais de type .64
12 Certificat.66
13 Notice d’emploi et de maintenance .66
Annexe A (informative) Guide pour l’utilisation des moniteurs de contamination
radioactive de l’eau.76
Annexe B (informative) Réalisation d’un effluent artificiel pour les essais .80
Tableau 1 –Conditions de référence et conditions normales d’essais .68
Tableau 2 – Essais effectués dans les conditions normales d’essais .70
Tableau 3 – Essais réalises avec variation des grandeurs d’influence.72
Tableau 4 – Essais du circuit hydraulique .74
60861 IEC:2006 – 5 –
9 Electrical performance tests .59
9.1 Warm-up time – Detection and measurement assemblies .59
9.2 Power-supply variations .59
9.3 Power-supply transient effects.61
9.4 Alarm-trip stability .61
9.5 Alarm-trip range .61
9.6 Fault alarm .63
10 Environmental performance test .63
10.1 Ambient temperature .63
10.2 Relative humidity.65
10.3 External electromagnetic immunity and electrostatic discharge .65
10.4 Electromagnetic emission.65
11 Type test report .65
12 Certificate.67
13 Operation and maintenance manual .67
Annex A (informative) Guidance for use with radioactive water monitors.77
Annex B (informative) Realization of an artificial effluent for testing .81
Table 1 – Reference and standard test conditions.69
Table 2 – Tests performed under standard test conditions .71
Table 3 – Tests performed with variation of influence quantities.73
Table 4 – Tests of liquid circuit .75
– 6 – 60861 CEI:2006
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
ÉQUIPEMENTS POUR LA SURVEILLANCE DES RADIONUCLÉIDES
DANS LES EFFLUENTS LIQUIDES ET LES EAUX DE SURFACE
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60861 a été établie par le sous-comité 45B: Instrumentation pour
la radioprotection, du comité d'études 45 de la CEI: Instrumentation nucléaire.
Cette seconde édition annule et remplace la première édition de cette norme, parue en 1987,
ainsi que la première édition de la CEI 61311 parue en 1995.
Cette édition inclut les modifications techniques majeures suivantes par rapport à l’édition
précédente:
a) la prise en compte des évolutions technologiques, notamment la possibilité de surveil-
lance en continu de la radioactivité alpha des liquides;
b) les essais de compatibilité électromagnétique.
60861 IEC:2006 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
EQUIPMENT FOR MONITORING OF RADIONUCLIDES
IN LIQUID EFFLUENTS AND SURFACE WATERS
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60861 has been prepared by subcommittee 45B: Radiation
protection instrumentation, of IEC technical committee 45: Nuclear instrumentation.
This second edition cancels and replaces the first edition published in 1987 and the first
edition of IEC 61311 published in 1995.
This edition includes the following significant technical changes with respect to the previous
edition:
a) taking into account of the main technological evolutions, notably the feasibility of
continuous monitoring of alpha radioactivity in liquids;
b) tests of electromagnetic compatibility.
– 8 – 60861 CEI:2006
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
45B/499/FDIS 45B/518/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60861 IEC:2006 – 9 –
The text of this standard is based on the following documents:
FDIS Report on voting
45B/499/FDIS 45B/518/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 10 – 60861 CEI:2006
ÉQUIPEMENTS POUR LA SURVEILLANCE DES RADIONUCLÉIDES
DANS LES EFFLUENTS LIQUIDES ET LES EAUX DE SURFACE
1 Domaine d'application
Cette Norme internationale définit les exigences techniques pour les appareils de surveillance
des radionucléides émetteurs alpha, bêta ou gamma dans les effluents liquides et dans les
eaux de surface. Elle donne des directives générales sur les aptitudes de tels équipements et
indique où et quand ils peuvent être utilisés.
NOTE La possibilité de mesurer en continu la radioactivité alpha des liquides par concentration et collecte du
concentrât sur un filtre a été démontré. Aussi cette norme peut-elle être également applicable à la surveillance en
continu de la radioactivité alpha des liquides.
Cette norme s'applique aux équipements pour la surveillance en continu de l’activité:
– dans les effluents liquides qui peuvent être rejetés en fonctionnement normal;
– dans les eaux de l'environnement.
Cette norme ne s'applique pas aux équipements spécialement conçus pour l'utilisation dans
des conditions accidentelles pour lesquels des capacités supplémentaires peuvent être
requises.
Cette norme concerne exclusivement les équipements de surveillance en continu de l'activité
alpha globale, l'activité bêta globale pour les émetteurs bêta d'énergie supérieure à 150 keV
ou l'activité gamma, dans les rejets d'effluents liquides ou dans les eaux environnementales.
Elle ne concerne pas le prélèvement d'échantillon et l'analyse en laboratoire.
L'objet de cette norme est de présenter les exigences générales et de donner des exemples
de méthodes acceptables d'utilisation des équipements pour la surveillance en continu de
l’activité de l'eau.
Cette Norme internationale précise les caractéristiques générales, les procédures générales
d'essai, les caractéristiques sous rayonnement, électriques, de sécurité et environnementales
et l'identification et certification de l'équipement pour les équipements définis dans le domaine
d'application. Les exigences concernant la sécurité des équipements électriques figurent dans
la CEI 61010-1. Ces exigences de sécurité et les essais correspondants sont applicables si
l’industriel souhaite obtenir un label pour cet équipement avec le marquage correspondant
(par exemple CE, UL, etc.).
Cette norme s'applique aux moniteurs de surveillance de l'eau conçus pour remplir les
fonctions suivantes:
– mesure de l'activité volumique ou du taux de comptage (voir 5.1.2) dû à la présence de
radionucléides dans le liquide et de ses variations dans le temps;
– déclenchement d'une alarme en cas de dépassement d'une valeur limite de l'activité
volumique ou du taux de comptage dans l'eau.
L'Annexe A donne quelques lignes directrices pour l'utilisation de moniteurs de la
radioactivité dans l'eau.
60861 IEC:2006 – 11 –
EQUIPMENT FOR MONITORING OF RADIONUCLIDES
IN LIQUID EFFLUENTS AND SURFACE WATERS
1 Scope
This International Standard defines technical requirements for equipment for monitoring of
alpha-, beta- or gamma-emitting radionuclides in liquid effluents and surface waters, provides
some general guidance as to the possible detection capability of such equipment and
indicates when and where its uses may be practicable.
NOTE Alpha monitoring in liquids is a possibility that has been demonstrated using a concentration device and
collection of the concentrate in a filter, so this standard may also be applicable to alpha monitoring in liquids.
This standard is applicable to equipment for continuous monitoring of the activity:
– in liquid effluents which could be released in the environment during normal operations;
– in environmental waters.
This standard does not apply to equipment specifically for use in accident conditions that may
require additional capabilities.
This standard is restricted to equipment for continuous monitoring of gross alpha or gross
beta of maximum energy higher than 150 keV or gamma activity in liquid effluent streams and
environmental waters. It does not deal with sample extraction and laboratory analysis.
The object of this standard is to lay down general requirements and give examples of
acceptable methods for equipment to monitor continuously the activity of water.
This International Standard specifies, for the equipment described in the scope, the general
characteristics, general test procedures, radiation, electrical, safety and environmental
characteristics, and the identification and certification of the equipment. Performance
requirements for the safe operation of electrical equipment are provided in IEC 61010-1.
These safety requirements and corresponding tests are applicable if the manufacturer wants
to, or is required to, label its equipment with the appropriate safety mark (for example, CE,
UL, etc.).
This standard is applicable to water monitors intended to fulfil the following functions:
– measurement of the volumetric activity or count rate (see 5.1.2) due to radionuclides in
the liquid and its variation with time;
– actuation of an alarm when a limit value of volumetric activity or count rate in water is
exceeded.
Annex A gives some guidance for use with radioactive water monitors.
– 12 – 60861 CEI:2006
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60038:1983, Tensions normales de la CEI
Amendement 1 (1994)
Amendement 2 (1997)
CEI 60050-393:2003, Vocabulaire Electrotechnique International (VEI) – Chapitre 393:
Instrumentation nucléaire: Phénomènes physiques et notions fondamentales
CEI 60050-394:1995, Vocabulaire Electrotechnique International (VEI) – Chapitre 394:
Instrumentation nucléaire: Instruments
Amendement 1 (1996)
Amendement 2 (2000)
CEI 60068-2-38:1974, Essais fondamentaux climatiques et de robustesse mécanique –
Deuxième partie: Essais. Essais Z/AD: Essai cyclique composite de température et d’humidité
CEI 61000-4-2:2001, Compatibilité électromagnétique (CEM) – Partie 4-2: Techniques d'essai
et de mesure – Essai d'immunité aux décharges électrostatiques
Amendement 1 (1998)
Amendement 2 (2000)
CEI 61000-4-3:2006, Compatibilité électromagnétique (CEM) – Partie 4-3: Techniques d'essai
et de mesure – Essai d'immunité aux champs électromagnétiques rayonnés aux fréquences
radioélectriques
CEI 61000-4-4:2004, Compatibilité électromagnétique (CEM) – Partie 4-4: Techniques d'essai
et de mesure –Essais d'immunité aux transitoires électriques rapides en salves.
CEI 61000-4-5:2005, Compatibilité électromagnétique (CEM) – Partie 4-5: Techniques d'essai
et de mesure – Essai d'immunité aux ondes de choc
CEI 61000-4-6:2004, Compatibilité électromagnétique (CEM) – Partie 4-6: Techniques d'essai
et de mesure – Immunité aux perturbations conduites, induites par les champs
radioélectriques
Amendement 1 (2004)
CEI 61000-4-11:2004, Compatibilité électromagnétique (CEM) – Partie 4-11: Techniques
d'essai et de mesure – Essais d'immunité aux creux de tension, coupures brèves et variations
de tension
CEI 61000-4-12:1995, Compatibilité électromagnétique (CEM) – Partie 4-12: Techniques
d'essai et de mesure – Essai d'immunité aux ondes oscillatoires
Amendement 1 (2000)
CEI 61000-6-4:1997, Compatibilité électromagnétique (CEM) – Partie 6: Normes génériques –
Section 4: Norme sur l'émission pour les environnements industriels
———————
Il existe une édition consolidée 6.2 (2002) incluant l’édition 6.0 et ses amendements 1 et 2.
Il existe une édition consolidée 1.2 (2001) incluant l’édition 1.0 et ses amendements 1 et 2.
Il existe une édition consolidée 2.1 (2004) incluant l’édition 2.0 et son amendement 1.
Il existe une édition consolidée 1.1 (2001) incluant l’édition 1.0 et son amendement 1.
60861 IEC:2006 – 13 –
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60038:1983, IEC standard voltages
Amendment 1 (1994)
Amendment 2 (1997)
IEC 60050-393:2003, International Electrotechnical Vocabulary (IEV) – Part 393: Nuclear
instrumentation – Physical phenomena and basic concepts
IEC 60050-394:1995, International Electrotechnical Vocabulary (IEV) – Chapter 394: Nuclear
instrumentation – Instruments
Amendment 1 (1996)
Amendment 2 (2000)
IEC 60068-2-38:1974, Basic environmental testing procedures – Part 2-38: Tests − Test Z/AD:
Composite temperature/humidity cyclic test
IEC 61000-4-2:2001 Electromagnetic compatibility (EMC) − Part 4-2: Testing and measure-
ment techniques – Electrostatic discharge immunity test
Amendment 1 (1998)
Amendment 2 (2000)
IEC 61000-4-3:2006, Electromagnetic compatibility (EMC) – Part 4-3: Testing and measure-
ment techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4:2004, Electromagnetic compatibility (EMC) – Part 4-4: Testing and
measurement techniques – Electrical fast transient/burst immunity test
IEC 61000-4-5:2005, Electromagnetic compatibility (EMC) – Part 4-5: Testing and measure-
ment techniques – Surge immunity test
IEC 61000-4-6:2004, Electromagnetic compatibility (EMC) – Part 4-6: Testing and measure-
ment techniques – Immunity to conducted disturbances, induced by radio-frequency fields
Amendment 1 (2004)
IEC 61000-4-11:2004, Electromagnetic compatibility (EMC) – Part 4-11: Testing and measure-
ment techniques – Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-12:1995, Electromagnetic compatibility (EMC) – Part 4-12: Testing and measure-
ment techniques – Oscillatory waves immunity test
Amendment 1 (2000)
IEC 61000-6-4:1997, Electromagnetic compatibility (EMC) – Part 6: Generic standards –
Section 4: Emission standard for industrial environments
———————
There exists a consolidated edition 6.2 (2002) including edition 6.0 and its amendments 1 and 2.
There exists a consolidated edition 1.2 (2001) including edition 1.0 and its amendments 1 and 2.
There exists a consolidated edition 2.1 (2004) including edition 2.0 and its amendment 1.
There exists a consolidated edition 1.1 (2001) including edition 1.0 and its amendment 1.
– 14 – 60861 CEI:2006
CEI 61010-1:2001, Règles de sécurité pour appareils électriques de mesurage, de régulation
et de laboratoire – Partie 1: Prescriptions générales
CEI 61187:1993, Equipements de mesure électrique et électronique – Documentation
ISO Guide pour l’expression de l’incertitude de mesure (GUM), 1995.
ISO 10012: 2003, Systèmes de management de la mesure – Exigences pour les processus et
les équipements de mesure
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions concernant la mesure des
rayonnements ionisants et l'instrumentation nucléaire, qui sont donnés dans la CEI 60050-393
et dans la CEI 60050-394, ainsi que les termes et définitions suivants, s'appliquent.
3.1
moniteur eau
équipement destiné à la surveillance de la radioactivité des effluents liquides rejetés dans
l’environnement et des eaux de l’environnement
3.2
surveillance de l’activité
différentes méthodes de surveillance:
Moniteurs avec échantillonnage,
mesure simultanée,
mesure séquentielle discrète,
Moniteurs sans échantillonnage:
mesure directe
3.3
mesure continue
mesure simultanée et la mesure séquentielle discrète
3.4
mesure simultanée
mesure d’un prélèvement effectuée en même temps que celui-ci est collecté
NOTE Des mesures réalisées avec un détecteur en contact avec le liquide (détecteur bêta) ou immergé dans
celui-ci (détecteur gamma) sont considérées comme des mesures simultanées.
3.5
mesure séquentielle discrète
mesure d’un prélèvement réalisée séparément de la collecte de l’échantillon avec une durée
de collecte et un temps courts depuis la collecte de la mesure
3.6
mesure directe
mesure avec un détecteur immergé dans le flux liquide ou adjacent au conduit dans lequel
coule le liquide, sans prélèvement
3.7
ensemble de prélèvement
ensemble utilisé pour le prélèvement d’un échantillon représentatif
60861 IEC:2006 – 15 –
IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control,
and laboratory use – Part 1: General requirements.
IEC 61187:1993, Electrical and electronic measuring equipment – Documentation
ISO Guide to the expression of uncertainty in measurement (GUM), 1995.
ISO 10012:2003, Measurement management systems – Requirements for measurement
processes and measuring equipment
3 Terms and definitions
For the purposes of this document, the terms and definitions concerning detection and
measurement of ionizing radiation and nuclear instrumentation given in IEC 60050-393 and
IEC 60050-394, as well as the following, apply.
3.1
water monitor
...








Questions, Comments and Discussion