Buy Standard

Standard
IEC 61156-5:2009/COR1:2009 - Corrigendum 1 - Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Horizontal floor wiring - Sectional specification Released:5/13/2009
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 61156-5
(Second edition – 2009)
Multicore and symmetrical pair/quad cables for digital communications – Part 5: Symmetrical pair/quad
cables with transmission characteristics up to 1 000 MHz – Horizontal floor wiring – Sectional

specification
C O R R I G E N D U M 1
6  Characteristics and requirements
6.2  Electrical characteristics and tests
Add the following note:
NOTE  For cat7 , unless the test is performed with very sensitive test equipment, it is recommended to limit the cable length to
A
50 m for a better accuracy in high frequencies.
6.3.6  Far-end crosstalk (FEXT)
Table 7 – Worst-pair PS EL FEXT(1) values
In the PS EL FEXT(1) column for Category 7, instead of:
“92,3”
read :
“91”.
6.3.10  Impedance
Replace the existing text of 6.3.10 by the following. There is no change to Figure 1.
The impedance requirement is specified by either case A or case B below as specified in the
relevant detail specification.

Case A (Fitted or mean characteristic impedance):

The impedance measured in accordance with 6.3.10.2 or 6.3.10.3 of IEC 61156-1 shall be
100 Ω ± 5 Ω at 100 MHz. In this case, the return loss shall also be
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.