General Information

Abstract

IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.

Status
Published
Publication Date
09-Apr-2014
Drafting Committee
MT 24 - TC 62/SC 62D/MT 24
Current Stage
PPUB - Publication issued
Start Date
10-Apr-2014
Completion Date
30-Apr-2014

Buy Documents

Standard

IEC 60601-2-36:2014 - Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy Released:4/10/2014

ISBN:978-2-8322-1498-5
English and French language (41 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 60601-2-36:2014 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on the basic safety and essential performance of medical electrical equipment used for extracorporeally induced lithotripsy (EIL). This particular standard is part 2-36 of the IEC 60601 series, which targets specific requirements supplementing the general safety standard IEC 60601-1.

Extracorporeally induced lithotripsy is a therapeutic procedure that applies focused pressure pulses outside the body to break down kidney stones and other calculi. IEC 60601-2-36:2014 governs equipment directly involved in EIL, including the pressure pulse generator and patient support device, ensuring safety and performance during clinical use.

This second edition updates and aligns the document structurally with IEC 60601-1:2005 and its amendment 1:2012, superseding the original 1997 edition. It excludes devices like patient treatment planning computers, X-ray and ultrasonic imaging devices, physiotherapy ultrasound equipment, and high-intensity therapeutic ultrasound (HITU) devices, which are regulated by other respective IEC standards.

Key Topics

  • Scope and Application
    The standard applies strictly to electrical medical equipment generating extracorporeally induced pressure pulses and their immediate associated components. It excludes diagnostic imaging tools and physiotherapy devices.

  • Basic Safety Requirements
    The document sets mandatory safety measures to protect patients and operators from electrical, mechanical, radiation, and temperature-related hazards during lithotripsy treatment.

  • Essential Performance Criteria
    Ensures that equipment reliably delivers therapeutic focused pressure pulses with precision in dosing and targeting in line with clinical needs, avoiding hazardous outputs or malfunctions.

  • Testing and Classification
    Detailed requirements for equipment testing procedures are outlined to verify compliance. Classification of medical electrical equipment (ME equipment) and medical electrical systems (ME systems) is specified for risk management.

  • Electromagnetic Compatibility (EMC)
    Addresses the EMC aspects to minimize electromagnetic interference and ensure proper functioning of lithotripsy devices in medical environments.

  • Documentation and Marking
    The standard mandates clear identification, instruction manuals, and labeling to facilitate safe operation and maintenance.

  • Programmable Electrical Medical Systems (PEMS)
    Special provisions apply to programmable components within the lithotripsy equipment, emphasizing software safety and fault control.

  • Annexes and Guidance
    Informative annexes provide technical rationale, coordinate definitions for focus and target location, and practical implementation guidance.

Applications

IEC 60601-2-36:2014 is crucial for:

  • Manufacturers designing and producing extracorporeal lithotripsy machines and related medical devices to ensure conformity with international safety standards.
  • Healthcare facilities employing lithotripsy equipment to comply with regulatory requirements for patient and staff safety.
  • Regulatory bodies evaluating equipment compliance as part of medical device approval processes worldwide.
  • Biomedical engineers and technicians involved in testing, maintenance, and calibration of extracorporeal lithotripsy systems.
  • Clinical researchers and developers designing innovation in lithotripsy technologies focused on therapeutic pressure pulse generation.

Implementing this standard supports reducing risks associated with electric shocks, mechanical failures, radiation hazards, and software malfunctions while maintaining treatment efficacy and patient safety.

Related Standards

IEC 60601-2-36:2014 is part of the broader IEC 60601 family addressing medical electrical equipment safety. Key related standards include:

  • IEC 60601-1:2005 (Amendment 1:2012) - General requirements for basic safety and essential performance of medical electrical equipment.
  • IEC 60601-2-37 - Particular requirements for ultrasonic medical diagnostic and monitoring equipment.
  • IEC 60601-1-2 - Requirements for electromagnetic compatibility of medical electrical equipment.
  • Standards for Ultrasound Physiotherapy Equipment - Separate standards govern therapeutic ultrasound devices not covered under IEC 60601-2-36.
  • ISO/IEC Directives, Part 2 - Guiding principles for drafting and structuring IEC standards.

By integrating the requirements of IEC 60601-2-36 with these complementary standards, stakeholders can achieve comprehensive compliance for devices used in lithotripsy and related therapeutic applications.


Keywords: IEC 60601-2-36, extracorporeally induced lithotripsy, medical electrical equipment, basic safety, essential performance, therapeutic pressure pulses, medical device standards, electromagnetic compatibility, patient safety, IEC standards, lithotripsy equipment requirements.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 60601-2-36:2014 - Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy Released:4/10/2014

ISBN:978-2-8322-1498-5
English and French language (41 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 60601-2-36:2014 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy". This standard covers: IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.

IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.

IEC 60601-2-36:2014 is classified under the following ICS (International Classification for Standards) categories: 11.040.01 - Medical equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60601-2-36:2014 has the following relationships with other standards: It is inter standard links to IEC 60601-2-36:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 60601-2-36:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 60601-2-36 ®
Edition 2.0 2014-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Medical electrical equipment –
Part 2-36: Particular requirements for the basic safety and essential performance
of equipment for extracorporeally induced lithotripsy

Appareils électromédicaux –
Partie 2-36: Exigences particulières pour la sécurité de base et les performances
essentielles des appareils pour lithotritie créée de façon extracorporelle

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,

77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
14 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
Plus de 55 000 entrées terminologiques électrotechniques, en
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des

CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 60601-2-36 ®
Edition 2.0 2014-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Medical electrical equipment –

Part 2-36: Particular requirements for the basic safety and essential performance

of equipment for extracorporeally induced lithotripsy

Appareils électromédicaux –
Partie 2-36: Exigences particulières pour la sécurité de base et les performances

essentielles des appareils pour lithotritie créée de façon extracorporelle

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX S
ICS 11.040.01 ISBN 978-2-8322-1498-5

– 2 – IEC 60601-2-36:2014  IEC 2014
CONTENTS
FOREWORD . 3
INTRODUCTION . 6
201.1 Scope, object and related standards . 7
201.2 Normative references . 8
201.3 Terms and definitions . 9
201.4 General requirements . 10
201.5 General requirements for testing ME EQUIPMENT . 10
201.6 Classification of ME EQUIPMENT and ME SYSTEMS . 11
201.7 ME EQUIPMENT identification, marking and documents . 11
201.8 Protection against electrical HAZARDS from ME EQUIPMENT . 12
201.9 Protection against MECHANICAL HAZARDS OF ME EQUIPMENT and ME SYSTEMS . 12
201.10 Protection against unwanted and excessive radiation HAZARDS . 13
201.11 Protection against excessive temperatures and other HAZARDS . 13
201.12 Accuracy of controls and instruments and protection against hazardous
outputs . 13
201.13 HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT . 14
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS) . 15
201.15 Construction of ME EQUIPMENT . 15
201.16 ME SYSTEMS . 15
201.17 ELECTROMAGNETIC COMPATIBILITY of ME EQUIPMENT and ME SYSTEMS . 15
202 * ELECTROMAGNETIC COMPATIBILITY – Requirements and tests . 15
Annexes . 15
Annex AA (informative) Particular guidance and rationale . 16
Annex BB (informative) Definition of coordinates, FOCUS and TARGET LOCATION . 17
Bibliography . 18
Index of defined terms used in this particular standard . 20

Figure BB.1 – Geometrical FOCUS distribution . 17

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MEDICAL ELECTRICAL EQUIPMENT –

Part 2-36: Particular requirements for the basic safety and essential
performance of equipment for extracorporeally induced lithotripsy

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International standard IEC 60601-2-36 has been prepared by IEC subcommittee 62D:
Electromedical equipment, of IEC technical committee 62: Electrical equipment in medical
practice.
This second edition cancels and replaces the first edition of IEC 60601-2-36 published in
1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005
and its Amendment 1:2012).
– 4 – IEC 60601-2-36:2014  IEC 2014
The text of this particular standard is based on the following documents:
FDIS Report on voting
62D/1109/FDIS 62D/1122/RVD
Full information on the voting for the approval of this particular standard can be found in the
report on voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
In this standard, the following print types are used:
– Requirements and definitions: roman type.
– Test specifications: italic type.
– Informative material appearing outside of tables, such as notes, examples and references: in smaller type.
Normative text of tables is also in a smaller type.
– TERMS DEFINED IN CLAUSE 3 OF THE GENERAL STANDARD, IN THIS PARTICULAR STANDARD OR AS
NOTED: SMALL CAPITALS.
In referring to the structure of this standard, the term
– “clause” means one of the numbered divisions within the table of contents, inclusive of all
subdivisions (e.g. Clause 7 includes subclauses 7.1, 7.2, etc.);
– “subclause” means a numbered subdivision of a clause (e.g. 7.1, 7.2 and 7.2.1 are all
subclauses of Clause 7).
References to clauses within this standard are preceded by the term “Clause” followed by the
clause number. References to subclauses within this particular standard are by number only.
In this standard, the conjunctive “or” is used as an “inclusive or” so a statement is true if any
combination of the conditions is true.
The verbal forms used in this standard conform to usage described in Annex H of the ISO/IEC
Directives, Part 2. For the purposes of this standard, the auxiliary verb:
– “shall” means that compliance with a requirement or a test is mandatory for compliance
with this standard;
– “should” means that compliance with a requirement or a test is recommended but is not
mandatory for compliance with this standard;
– “may” is used to describe a permissible way to achieve compliance with a requirement or
test.
An asterisk (*) as the first character of a title or at the beginning of a paragraph or table title
indicates that there is guidance or rationale related to that item in Annex AA.
A list of all parts of the IEC 60601 series, published under the general title Medical electrical
equipment, can be found on the IEC website.

The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – IEC 60601-2-36:2014  IEC 2014
INTRODUCTION
This particular standard concerns the BASIC SAFETY and ESSENTIAL PERFORMANCE of equipment
for EXTRACORPOREALLY INDUCED LITHOTRIPSY. It amends and supplements IEC 60601-1/A1:2012
(Ed. 3.1): Medical electrical equipment – Part 1: General requirements for basic safety and
essential performance), hereinafter referred to as the general standard.
The aim of this second edition is to bring this particular standard up to date with reference to
the third edition of the general standard through reformatting and technical changes.
The requirements of this particular standard take priority over those of the general standard.
A “General guidance and rationale” for the more important requirements of this particular
standard is included in Annex AA. It is considered that knowledge of the reasons for these
requirements will not only facilitate the proper application of the standard but will, in due
course, expedite any revision necessitated by changes in clinical practice or as a result of
developments in technology. However, Annex AA does not form part of the requirements of
this standard.
MEDICAL ELECTRICAL EQUIPMENT –

Part 2-36: Particular requirements for basic safety and essential
performance of equipment for extracorporeally induced lithotripsy

201.1 Scope, object and related standards
Clause 1 of the general standard applies, except as follows:
201.1.1 Scope
Replacement:
This particular standard applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of equipment for
EXTRACORPOREALLY INDUCED LITHOTRIPSY as defined in 201.3.206 including equipment for
other medical applications of therapeutic extracorporeally induced focused PRESSURE PULSES,
hereafter referred to as ME EQUIPMENT. The applicability of this particular standard is limited to
components directly involved in the LITHOTRIPSY treatment, such as, but not limited to, the
generator of the PRESSURE PULSE, PATIENT support device, and their interactions with imaging
and monitoring devices. Other devices, such as PATIENT treatment planning computers, X-ray
and ultrasonic devices, are excluded from this standard, because they are treated in other
applicable IEC standards.
This particular standard does not apply to:
– ULTRASOUND PHYSIOTHERAPY EQUIPMENT intended to be used for physiotherapy;
– ULTRASOUND equipment intended to be used for high intensity therapeutic ULTRASOUND
(HITU) and other therapy equipment as described in Annex AA;
201.1.2 * Object
Replacement:
The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL
PERFORMANCE requirements of equipment for EXTRACORPOREALLY INDUCED LITHOTRIPSY as
defined in 201.3.206 including equipment for other medical applications of therapeutic
extracorporeal focused PRESSURE PULSES.
201.1.3 Collateral standards
Addition:
This particular standard refers to those applicable collateral standards that are listed in
Clause 2 of the general standard and Clause 201.2 of this particular standard.
IEC 60601-1-2:2007 applies as modified in Clause 202. IEC 60601-1-3 and IEC 60601-1-10
do not apply. All other published collateral standards in the IEC 60601-1 series apply as
published.
—————————
The general standard is IEC 60601-1:2005/A1:2012, Medical electrical equipment – Part 1: General
requirements for basic safety and essential performance.
IEC 60601-1-10:2007, Medical electrical equipment – Part 1-10: General requirements for basic safety and
essential performance – Collateral Standard: Requirements for the development of physiologic closed-loop
controllers
– 8 – IEC 60601-2-36:2014  IEC 2014
201.1.4 Particular standards
Replacement:
In the IEC 60601 series, particular standards may modify, replace or delete requirements
contained in the general standard and collateral standards as appropriate for the particular
ME EQUIPMENT under consideration, and may add other BASIC SAFETY and ESSENTIAL
PERFORMANCE requirements.
A requirement of a particular standard takes priority over the general standard.
For brevity, IEC 60601-1 is referred to in this particular standard as the general standard.
Collateral standards are referred to by their document number.
The numbering of clauses and subclauses of this particular standard corresponds to that of
the general standard with the prefix “201” (e.g. 201.1 in this standard addresses the content
of Clause 1 of the general standard) or applicable collateral standard with the prefix “20x”
where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this
particular standard addresses the content of Clause 4 of the IEC 60601-1-2 collateral
standard, 203.4 in this particular standard addresses the content of Clause 4 of the
IEC 60601-1-3 collateral standard, etc.). The changes to the text of the general standard are
specified by the use of the following words:
"Replacement" means that the clause or subclause of the general standard or applicable
collateral standard is replaced completely by the text of this particular standard.
"Addition" means that the text of this particular standard is additional to the requirements of
the general standard or applicable collateral standard.
"Amendment" means that the clause or subclause of the general standard or applicable
collateral standard is amended as indicated by the text of this particular standard.
Subclauses, figures or tables which are additional to those of the general standard are
numbered starting from 201.101. However due to the fact that definitions in the general
standard are numbered 3.1 through 3.139, additional definitions in this standard are
numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and
additional items aa), bb), etc.
Subclauses, figures or tables which are additional to those of a collateral standard are
numbered starting from 20x, where “x” is the number of the collateral standard, e.g. 202 for
IEC 60601-1-2, 203 for IEC 60601-1-3, etc.
The term "this standard" is used to make reference to the general standard, any applicable
collateral standards and this particular standard taken together.
Where there is no corresponding clause or subclause in this particular standard, the clause or
subclause of the general standard or applicable collateral standard, although possibly not
relevant, applies without modification; where it is intended that any part of the general
standard or applicable collateral standard, although possibly relevant, is not to be applied, a
statement to that effect is given in this particular standard.
201.2 Normative references
Clause 2 of the general standard applies, except as follows:
Replacement:
IEC 60601-1-2:2007, Medical electrical equipment – Part 1-2: General requirements for basic
safety and essential performance – Collateral standard: Electromagnetic compatibility –
Requirements and tests
Addition:
IEC 60601-1:2005, Medical electrical equipment – Part 1: General requirements for basic
safety and essential performance
Amendment 1:2012
IEC 60601-2-5:2009, Medical electrical equipment – Part 2-5: Particular requirements for the
basic safety and essential performance of ultrasonic physiotherapy equipment
IEC 61846:1998, Ultrasonics – Pressure pulse lithotripters: Characterization of fields
201.3 Terms and definitions
NOTE An index of defined terms is found beginning on page 20.
For the purpose of this document, the terms and definitions given in IEC 60601-1:2005/A1:2012
apply, except as follows:
Additional definitions:
201.3.201
ENERGY FLUX DENSITY
derived pulse-intensity integral as defined in 3.4 and 7.3.2 of IEC 61846 at the position of the
FOCUS
201.3.202
ENERGY PER PULSE
derived acoustic pulse energy as defined in 7.3.4 of IEC 61846
Note 1 to entry: The temporal integration limits (3.23 of IEC 61846) and the radius R of the chosen circular cross
section area shall be stated in order to allow for proper interpretation of the values.
201.3.203
EXTRACORPOREALLY INDUCED LITHOTRIPSY
LITHOTRIPSY inside the PATIENT by pressure pulses generated outside the PATIENT
201.3.204
FOCAL VOLUME
volume in space contained within the surface defined by the –6 dB isobar of the maximum
peak compressional acoustic pressure
201.3.205
LITHOTRIPSY
comminution or fragmentation of calculi
201.3.206
LITHOTRIPSY EQUIPMENT
ME-EQUIPMENT intended to be used for LITHOTRIPSY treatment
201.3.207
* LOCALIZATION DEVICE
device used to determine the position of the calculi in (three-dimensional) space

– 10 – IEC 60601-2-36:2014  IEC 2014
201.3.208
POSITIONING DEVICE
device which brings the calculi into coincidence with the TARGET LOCATION
Note 1 to entry: See also IEC 61846:1998, 3.22, TARGET LOCATION.
201.3.209
PRESSURE PULSE
acoustic wave emitted by the LITHOTRIPSY EQUIPMENT
[SOURCE: IEC 61846, definition 3.18 and Clause C.4]
201.3.210
PRESSURE PULSE COUPLING
any means allowing transition of the PRESSURE PULSE from the ME EQUIPMENT into the PATIENT
201.3.211
TARGET MARKER
marker which is used to indicate the TARGET LOCATION¨
EXAMPLE A marker on the imaging device.
Note 1 to entry: See also IEC 61846:1998, 3.22, TARGET LOCATION.
201.4 General requirements
Clause 4 of the general standard applies, except as follows:
201.4.3 ESSENTIAL PERFORMANCE
Addition:
201.4.3.101 Additional requirements for ESSENTIAL PERFORMANCE
The ME EQUIPMENT shall be free from incorrect display of energy levels (see 201.12.1.102).
The ME EQUIPMENT shall be free from unintended shock wave release (see 201.12.4.6).
201.4.7 SINGLE FAULT CONDITION for ME EQUIPMENT
Addition:
Safety in SINGLE FAULT CONDITION of the PRESSURE PULSE release (avoiding faulty release) and
safety in SINGLE FAULT CONDITION in motor supported positioning (to avoid unintentional
changes of position during PRESSURE PULSE release and mechanical danger) shall be ensured.
These requirements may be met by mutually interlocking the two systems, e.g. by mutually
interlocking the PRESSURE PULSE release with a SINGLE FAULT CONDITION secured positioning
device, or by mutually interlocking the POSITIONING DEVICE with a SINGLE FAULT CONDITION
secured PRESSURE PULSE release. This mutual interlocking may be overridden by a deliberate
action of the OPERATOR, for example by pressing a separate switch, if the position of the
calculus is monitored.
Compliance is checked by functional testing and fault analysis.
201.5 General requirements for testing ME EQUIPMENT
Clause 5 of the general standard applies.

201.6 Classification of ME EQUIPMENT and ME SYSTEMS
Clause 6 of the general standard applies.
201.7 ME EQUIPMENT identification, marking and documents
Clause 7 of the general standard applies, except as follows:
201.7.9.2 Instructions for use
Addition:
201.7.9.2.101 Additional instructions for use
The instructions for use shall also include:
a) description of the relevant safety precautions to be used to avoid HAZARDOUS SITUATIONS,
e.g. the danger resulting from delivering PRESSURE PULSES to organs which contain gas;
b) caution that PRESSURE PULSES may cause unwanted cardiac activity;
c) when using ECG monitoring equipment to trigger the generation of the PRESSURE PULSE,
only those ECG monitors specified by the MANUFACTURER of the ME EQUIPMENT shall be
used;
d) caution that the OPERATOR shall check the position of the calculi as often as necessary to
ensure proper treatment;
e) description of the schedule and measures to be performed within the scope of a regular
performance check;
f) description concerning the correct use of the PRESSURE PULSE COUPLING including a
reminder that it shall be free of bubbles;
g) reminder that the PRESSURE PULSE is attenuated during passage through tissue, and that
additional energy is absorbed by bone;
h) reminder that, even if anti-collision devices are installed, the OPERATOR shall always watch
for any movements that may cause danger to the PATIENT or OPERATOR.
201.7.9.3 * Technical description
Addition:
201.7.9.3.101 Additional technical description
The technical description for use shall also include:
a) positional precision of the TARGET MARKER with respect to the TARGET LOCATION;
b) position and size of the FOCAL VOLUME at minimum, typical and maximum shockwave
generator output settings with respect to the TARGET LOCATION, stating the positions of the
-6 dB pressure values along the shockwave source axis and perpendicular to the shock
wave axis at the position of the FOCUS (See Annex BB);
c) peak compressional and rarefactional acoustic pressures at the minimum, typical and
maximum output settings;
d) ENERGY FLUX DENSITY at the minimum, typical and maximum output settings, including the
specification of the temporal integration limits;
e) ENERGY PER PULSE including the specification of the temporal integration limits and the
radius R of the chosen circular cross section area at the minimum, typical and maximum
output settings.
– 12 – IEC 60601-2-36:2014  IEC 2014
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
Clause 8 of the general standard applies, except as follows:
201.8.7 LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
201.8.7.1 * General requirements
Addition to the third dash:
PATIENT LEAKAGE CURRENT shall not be measured during the PRESSURE PULSE release.
The
201.8.8.3 Dielectric strength
Table 6 – Test voltages for solid insulation forming a MEANS OF PROTECTION
Addition:
Voltages higher than 14 140 V shall be tested with a factor of 1,2.
Table 7 – Test voltages for MEANS OF OPERATOR PROTECTION
Addition:
Voltages higher than 10 000 V shall be tested with a factor of 1,2.
201.9 Protection against MECHANICAL HAZARDS OF ME EQUIPMENT and
ME SYSTEMS
Clause 9 of the general standard applies, except as follows:
201.9.2.2.5 Continuous activation
Addition:
Systems which have powered movements shall be designed to avoid excessive force being
exerted on the PATIENT. ME EQUIPMENT movements which may endanger the PATIENT during
compression shall be prevented.
ACCESSORY parts shall be secured against falling out in all operating positions.
201.9.4.2.4.3 Movement over a threshold
Replacement of the compliance statement:
Compliance is checked by the following test: MOBILE ME EQUIPMENT shall be moved forward
using a contact as close as possible to the floor in its usual direction, at a speed to be
specified by the MANUFACTURER, but not more than 0,1 m/s, over a dimensionally stable
obstacle which has a rectangular cross-section, 10 mm high by 80 mm wide, which is placed
flat on the plane. The ME EQUIPMENT shall operate normally after this test.
201.9.6.2.1 * Audible acoustic energy
Replacement of the first dash by the two following dashes:

– 90 dBA for a cumulative exposure of 8 h over a 24 h period; an offset of 3 dBA is to be
added to this value when halving the cumulative exposure time over a 24 h period (e.g.
93 dBA for 4 h over a 24 h period);
– 105 dBA for a cumulative exposure of 1 h over a 24 h period; an offset of 3 dBA is to be
added to this value when halving the cumulative exposure time over a 24 h period (e.g.
108 dBA for 1/2 h over a 24 h period);
Addition before the compliance statement:
If the A-weighted sound pressure level exceeds 80 dBA, noise protection measures should be
considered
201.9.8.4.1 General
Addition:
Ropes, chains or belts running parallel to other ropes, chains or belts may be regarded as
antidrop safety devices if they remain unloaded during operation. Wire ropes may be used as
anti-drop devices only if they are checked at regular intervals.
201.10 Protection against unwanted and excessive radiation HAZARDS
Clause 10 of the general standard applies.
201.11 Protection against excessive temperatures and other HAZARDS
Clause 11 of the general standard applies, except as follows:
201.11.1.2.1 * APPLIED PARTS intended to supply heat to a PATIENT
Addition:
The surface temperature of the APPLIED PART shall not be lower than 5 °C below ambient
temperature, after a warm-up period specified by the MANUFACTURER.
201.11.7 Biocompatibility of ME EQUIPMENT and ME SYSTEMS
Addition:
If a coupling liquid (e.g. ULTRASOUND gel, oil, etc.) is used, then this liquid is considered to be
the ACCESSORY to come into direct or indirect contact with the biological tissues, cell or body
fluids.
201.11.8 Interruption of the power supply / SUPPLY MAINS to ME EQUIPMENT
Addition:
Upon restoration of the power supply, a deliberate action, for example the release and
repressing of a switch, is required to initiate PRESSURE PULSE release.
201.12 Accuracy of controls and instruments and protection against
hazardous outputs
Clause 12 of the general standard applies, except as follows:

– 14 – IEC 60601-2-36:2014  IEC 2014
201.12.1 Accuracy of controls and instruments
Addition:
201.12.1.101 Precision of TARGET MARKERS and TARGET LOCATIONS
Specifications of testing methods to test the alignment precision of TARGET MARKER and
TARGET LOCATION, including permissible deviations, shall be provided by the MANUFACTURER in
the instructions for use.
Compliance is checked by inspection.
201.12.1.102 Testing methods to recognize any deviation
Specification of testing methods to recognize any deviation of physical variables that may
result in an increased RISK to the PATIENT shall be provided by the MANUFACTURER.
Compliance is checked by inspection.
201.12.1.103 Constancy testing methods
Constancy testing methods shall be the responsibility of the MANUFACTURER, for both initial
ME EQUIPMENT quality control and for testing over the lifetime of the ME EQUIPMENT.
Compliance is checked by inspection.
201.12.4.3 Accidental selection of excessive output values
Addition:
The means to protect PATIENTS from unintended levels of the PRESSURE PULSES shall be safe in
SINGLE FAULT CONDITION.
Compliance is checked by inspection.
201.12.4.4 Incorrect output
Addition:
If the PRESSURE PULSE control device can be controlled by more than one device, these
devices shall be mutually interlocked.
Compliance is checked by inspection.
201.12.4.6 * Diagnostic or therapeutic acoustic pressure
Addition:
The release of PRESSURE PULSES shall be under the control of the OPERATOR through
deliberate and continued action.
Compliance is checked by inspection.
201.13 HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT
Clause 13 of the general standard applies.

201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
Clause 14 of the general standard applies.
201.15 Construction of ME EQUIPMENT
Clause 15 of the general standard applies, except as follows:
201.15.4.7.1 Mechanical strength
Addition:
The force required to actuate the foot switches shall not be smaller than 10 N.
Compliance is checked by measuring the operating force.
201.16 ME SYSTEMS
Clause 16 of the general standard applies.
201.17 ELECTROMAGNETIC COMPATIBILITY of ME EQUIPMENT and ME SYSTEMS
Clause 17 of the general standard applies.
202 * ELECTROMAGNETIC COMPATIBILITY – Requirements and tests
IEC 60601-1-2 applies except as follows:
Addition:
Compliance with IEC 60601-1-2 will be maintained, except during the triggering and
generation cycle of the PRESSURE PULSE release.

Annexes
The annexes of the general standard apply.

– 16 – IEC 60601-2-36:2014  IEC 2014
Annex AA
(informative)
Particular guidance and rationale

The following are rationales for specific clauses and subclause in this particular standard, with
clause and subclause numbers parallel to those in the body of the document.
Subclause 201.1.2 – Object
Parts of this standard that may not be applicable are: ME EQUIPMENT for other medical
applications of therapeutic pressure pulses which include unfocused pressure pulse sources,
pneumatically generated ballistic sources or ME EQUIPMENT without LOCALIZATION and/or
POSITIONING DEVICES, however, subclause 201.7.9.3.101 c) and d) may be applicable.
Subclause 201.3.207 – LOCALIZATION DEVICE
Means currently in use include X-ray, fluoroscopy and ULTRASOUND.
Subclause 201.7.9.3 – Technical description
The test methodologies for reporting item a) are at the discretion of the MANUFACTURER. Items
c), d) and e) refer to IEC 61846 ("Ultrasonics – Pressure pulse lithotripters – Characteristics
of field").
Subclause 201.8.7.1 – General requirements
During PRESSURE PULSE release it is not technically feasible to measure PATIENT LEAKAGE
CURRENT.
Subclause 201.9.6.2.1 – Audible acoustic energy
These levels were established by the Occupational Safety and Health Administration (OSHA)
in the United States. Transmission of excessive structureborne noise into the building is to be
minimized by appropriate design.
Subclause 201.11.1.2 – APPLIED PARTS intended to supply heat to a PATIENT
This additional paragraph has been inserted to prevent temperature shock to the PATIENT.
NOTE The surface temperature of the applied part should be chosen such as to avoid patient discomfort or pain
Subclause 201.12.4.6 – Diagnostic and therapeutic acoustic pressure
This requirement is motivated by the desire to ensure that the treatment is always under
control of the OPERATOR.
Clause 202 – ELECTROMAGNETIC COMPATIBILITY – Requirements and tests
During the triggering and generation cycle of the PRESSURE PULSE, it is not technically feasible
to maintain EMC, because this ME EQUIPMENT involves high-voltage electric discharges

Annex BB
(informative)
Definition of coordinates, FOCUS and TARGET LOCATION

In order to achieve consistent statements on the geometrical FOCUS distribution, the following
sketch gives definitions of an appropriate coordinate system and the positions of relevant
parameters:
z z
1 2
f = z + z
z 1 2
z
f (or f )
x y
(toward pressure
z axis (away from
pulse source)
Target location
pressure pulse source)
Focus (max. p+)
−6 dB isobar line
x axis
(or y axis)
IEC  1058/14
Figure BB.1 – Geometrical FOCUS distribution
NOTE The –6 dB isobar line represents a physical property of the pressure pulse source, it does not per se state
the elegible therapy area
– 18 – IEC 60601-2-36:2014  IEC 2014
Bibliography
IEC 60601-2-5:2009, Medical electrical equipment – Part 2-5: Particular requirements for the
basic safety and essential performance of ultrasonic physiotherapy equipment
IEC 60601-2-62, Particular requirements for the basic safety and essential performance of
high intensity therapeutic ultrasound (HITU) equipment
IEC 61689:2013, Ultrasonics – Physiotherapy systems – Field specifications and methods of
measurement in the frequency range 0,5 MHz to 5 MHz
IEC 62555, Ultrasonics – Power measurement – High intensity therapeutic ultrasound (HITU)
transducers and systems
IEC/TS 62556, Ultrasonics – Surgical systems – Specification and measurement of field
parameters for high intensity therapeutic ultrasound (HITU) transducers and systems
EN 10002/AC 1, Tensile testing of metallic materials – Part 1: Method of test, amendment to
EN 10002-1
DIN 50 100/02.78, Testing of materials, continuous vibration test – Definitions, symbols,
procedure, evaluation
CHAUSSY. Berührungsfreie Nierensteinzertrümmerung durch extrakorporal erzeugte,
fokussierte Stoßwellen. S. Karger Verlag, Basel,1980
RASSWEILER, HENKEL, KÖHRMANN, POTEMPA, JÜNEMANN, ALKEN. Lithotriptor
Technology: present and future. J. Endourology,1992, 6(1): 1–15
UEBERLE . Acoustic Parameters of Pressure Pulse Sources Used in Lithotripsy and Pain
Therapy. in: Chaussy et al (eds), High Energy Shock Waves in Medicine, pp 76–85, Thieme
Stuttgart, New York 1997
WESS, UEBERLE, DÜHRßEN, HILCKEN, REUNER, SCHULTHEIß, STAUDENRAUS,
RATTNER, HAAKS, GRANZ Working Group Technical Developments – Consensus Report. in
Chaussy et al (eds), High Energy Shock Waves in Medicine. Thieme, Stuttgart New York,
1997, pp 59–71
UEBERLE. Pressure Pulses in Medicine. In: Srivastava, Leutloff, Takayama, Groenig (eds)
Shock Focussing Effects in Medical Science and Sonoluminescence. Springer, Heidelberg
New York,2003
RASSWEILER, BERGSDORF, GINTER et al. Progress in Lithotripter Technology. In Chaussy,
Haupt, Jocham et al. (eds) Therapeutic Energy Applications in Urology. Thieme, Stuttgart
New York, 2005
RASSWEILER, TAILLY, CHAUSSY. Progress in Lithotriptor Technology, EAU Update Series
3 (2005) 17–36
LINGEMAN, MCATEER, GNESSIN, EVAN. Shock wave lithotripsy: advances in technology
and technique. Nature Reviews / Urology, 2009, Vol.6, pp. 660-670
RASSWEILER, BERGSDORF, BOHRIS, BURKHARDT, BURNES, FORSSMANN, MEINERT,
PARTHEYMÜLLER, VALLON, WESS, WILLIGER, CHAUSSY. Shock wave technology and
application – state of the art in 2009., Konsensus-Meeting der Deutschen Gesellschaft für
Stosswellenlithotripsie, 2010
UEBERLE Application of Shock Waves and Pressure Pulses in Medicine, in: Kramme,
Hoffmann, Pozos (eds.) Handbook of Medical Technology, Springer Berlin Heidelberg, 2011,
pp. 641-676
– 20 – IEC 60601-2-36:2014  IEC 2014
Index of defined terms used in this particular standard

ACCESSORY . IEC 60601-1:2005+A:2012, 3.3
APPLIED PART . IEC 60601-1:2005+A:2012, 3.8
BASIC SAFETY . IEC 60601-1:2005+A:2012, 3.10
ELECTROMAGNETIC COMPATIBILITY . IEC 60601-1-2:2007, 3.4
ENERGY FLUX DENSITY . 201.3.201
ENERGY PER PULSE . 201.3.202
ESSENTIAL PERFORMANCE . IEC 60601-1:2005+A:2012, 3.27
EXTRACORPOREALLY INDUCED LITHOTRIPSY . 201.3.203
FOCAL VOLUME . 201.3.204
HAZARD . IEC 60601-1:2005+A:2012, 3.39
HAZARDOUS SITUATION . IEC 60601-1:2005+A:2012, 3.40
LEAKAGE CURRENT . IEC 60601-1:2005+A:2012, 3.47
LITHOTRIPSY . 201.3.205
LITHOTRIPSY EQUIPMENT .
...