Smart Cards; UICC-Terminal interface; Physical, electrical and logical test specification; Part 1: Terminal features (Release 12)

RTS/SCP-00102230Tvc00

General Information

Status
Published
Publication Date
08-May-2019
Technical Committee
Current Stage
12 - Completion
Due Date
24-Apr-2019
Completion Date
09-May-2019
Ref Project

Buy Standard

Standard
ETSI TS 102 230-1 V12.0.0 (2019-05) - Smart Cards; UICC-Terminal interface; Physical, electrical and logical test specification; Part 1: Terminal features (Release 12)
English language
96 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

ETSI TS 102 230-1 V12.0.0 (2019-05)






TECHNICAL SPECIFICATION
Smart Cards;
UICC-Terminal interface;
Physical, electrical and logical test specification;
Part 1: Terminal features
(Release 12)

---------------------- Page: 1 ----------------------
Release 12 2 ETSI TS 102 230-1 V12.0.0 (2019-05)



Reference
RTS/SCP-00102230TVc00
Keywords
smart card, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2019.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.
TM TM
3GPP and LTE are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and
of the oneM2M Partners.
®
GSM and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI

---------------------- Page: 2 ----------------------
Release 12 3 ETSI TS 102 230-1 V12.0.0 (2019-05)
Contents
Intellectual Property Rights . 12
Foreword . 12
Modal verbs terminology . 12
Introduction . 13
1 Scope . 14
2 References . 14
2.1 Normative references . 14
2.2 Informative references . 15
3 Definition of terms, symbols, abbreviations and coding conventions . 15
3.1 Terms . 15
3.2 Symbols . 15
3.3 Abbreviations . 16
3.4 Coding conventions . 17
3.5 Applicability . 17
3.5.1 Applicability of the present document . 17
3.5.2 Applicability of the individual test cases . 17
3.5.3 Applicability to terminal equipment . 17
3.6 Definitions . 17
3.6.1 Format of table of the table of optional features . 17
3.6.2 Format of the applicability table . 18
3.6.3 Status and Notations . 18
3.7 Table of optional features . 18
3.8 Applicability table . 19
4 Physical characteristic tests . 23
4.1 Contact pressure . 23
4.1.1 Definition and applicability . 23
4.1.2 Conformance requirement . 23
4.1.2.0 Description . 23
4.1.2.1 Reference . 23
4.1.3 Test purpose . 23
4.1.4 Method of test . 23
4.1.4.1 Initial conditions . 23
4.1.4.2 Procedure . 23
4.1.5 Acceptance criteria . 23
4.2 Curvature of the contacting elements . 23
4.2.1 Definition and applicability . 23
4.2.2 Conformance requirement . 24
4.2.2.0 Description . 24
4.2.2.1 Reference . 24
4.2.3 Test purpose . 24
4.2.4 Method of test . 24
4.2.4.1 Initial conditions . 24
4.2.4.2 Procedure . 24
4.2.5 Acceptance criteria . 24
5 Electrical characteristic tests . 24
5.1 Test of the power transition phases . 24
5.1.1 Phase preceding Terminal power on . 24
5.1.1.1 Definition and applicability . 24
5.1.1.2 Conformance requirement . 24
5.1.1.3 Reference . 24
5.1.1.4 Test purpose . 25
5.1.1.5 Method of test . 25
5.1.1.5.1 Initial condition . 25
ETSI

---------------------- Page: 3 ----------------------
Release 12 4 ETSI TS 102 230-1 V12.0.0 (2019-05)
5.1.1.5.2 Procedure . 25
5.1.1.6 Acceptance criteria . 25
5.1.2 Phase during UICC power on . 25
5.1.2.1 Phase during UICC power on: 3 V - 5 V . 25
5.1.2.1.1 Definition and applicability . 25
5.1.2.1.2 Conformance requirement . 25
5.1.2.1.3 Reference . 25
5.1.2.1.4 Test purpose . 26
5.1.2.1.5 Method of test . 26
5.1.2.1.6 Acceptance criteria . 26
5.1.2.2 Phase during UICC power on: 1,8 V - 3 V . 26
5.1.2.2.1 Definition and applicability . 26
5.1.2.2.2 Conformance requirement . 26
5.1.2.2.3 Reference . 26
5.1.2.2.4 Test purpose . 26
5.1.2.2.5 Method of test . 27
5.1.2.2.6 Acceptance criteria . 27
5.1.3 Phase during Terminal power off . 27
5.1.3.1 Phase during Terminal power off: 3 V - 5 V . 27
5.1.3.1.1 Definition and applicability . 27
5.1.3.1.2 Conformance requirement . 27
5.1.3.1.3 Reference . 27
5.1.3.1.4 Test purpose . 28
5.1.3.1.5 Method of test . 28
5.1.3.1.6 Acceptance criteria . 28
5.1.3.2 Phase during Terminal power off: 1,8 V - 3 V . 28
5.1.3.2.1 Definition and applicability . 28
5.1.3.2.2 Conformance requirement . 28
5.1.3.2.3 Reference . 29
5.1.3.2.4 Test purpose . 29
5.1.3.2.5 Method of test . 29
5.1.3.2.6 Acceptance criteria . 29
5.1.4 Warm reset timing . 29
5.1.4.1 Definition and applicability . 29
5.1.4.2 Conformance requirement . 29
5.1.4.2.0 Description . 29
5.1.4.2.1 Reference . 30
5.1.4.3 Test purpose . 30
5.1.4.4 Method of test . 30
5.1.4.4.1 Initial conditions . 30
5.1.4.4.2 Procedure . 30
5.1.4.5 Acceptance criteria . 30
5.1.5 UICC type recognition and voltage switching . 30
5.1.5.1 Reaction of 3 V technology Terminals on type recognition of 3 V technology UICCs . 30
5.1.5.1.1 Definition and applicability . 30
5.1.5.1.2 Conformance requirement . 30
5.1.5.1.3 Reference . 30
5.1.5.1.4 Test purpose . 31
5.1.5.1.5 Method of test . 31
5.1.5.1.6 Acceptance criteria . 31
5.1.5.2 Reaction of 3 V technology Terminals on type recognition of 1,8 V technology UICCs . 31
5.1.5.2.1 Definition and applicability . 31
5.1.5.2.2 Conformance requirement . 31
5.1.5.2.3 Reference . 31
5.1.5.2.4 Test purpose . 32
5.1.5.2.5 Method of test . 32
5.1.5.2.6 Acceptance criteria . 32
5.1.5.3 Reaction of 1,8 V technology Terminals on type recognition of 1,8 V technology UICCs . 32
5.1.5.3.1 Definition and applicability . 32
5.1.5.3.2 Conformance requirement . 32
5.1.5.3.3 Reference . 32
5.1.5.3.4 Test purpose . 32
ETSI

---------------------- Page: 4 ----------------------
Release 12 5 ETSI TS 102 230-1 V12.0.0 (2019-05)
5.1.5.3.5 Method of test . 33
5.1.5.3.6 Acceptance criteria . 33
5.1.5.4 Reaction of 1,8 V technology Terminals on type recognition of 3 V technology UICCs . 33
5.1.5.4.1 Definition and applicability . 33
5.1.5.4.2 Conformance requirement . 33
5.1.5.4.3 Reference . 33
5.1.5.4.4 Test purpose . 33
5.1.5.4.5 Method of test . 34
5.1.5.4.6 Acceptance criteria . 34
5.1.5.5 Void. 34
5.1.5.6 Reaction of Terminals receiving no ATR . 34
5.1.5.6.1 Reaction of Terminals receiving no ATR: 3 V - 5 V . 34
5.1.5.6.2 Reaction of Terminals receiving no ATR: 1,8 V - 3 V . 35
5.2 Electrical tests on each Terminal contact . 36
5.2.1 Nominal test conditions . 36
5.2.2 Electrical tests on contact C1 (Card power supply - VCC). 36
5.2.2.1 Electrical tests on contact C1, Test 1: 3 V - 5 V . 36
5.2.2.1.1 Definition and applicability . 36
5.2.2.1.2 Conformance requirement . 37
5.2.2.1.3 Reference . 37
5.2.2.1.4 Test purpose . 37
5.2.2.1.5 Method of test . 37
5.2.2.1.6 Acceptance criteria . 37
5.2.2.2 Electrical tests on contact C1, Test 2: 3 V - 5 V . 37
5.2.2.2.1 Definition and applicability . 37
5.2.2.2.2 Conformance requirement . 37
5.2.2.2.3 Reference . 38
5.2.2.2.4 Test purpose . 38
5.2.2.2.5 Method of test . 38
5.2.2.2.6 Acceptance criteria . 40
5.2.2.3 Electrical tests on contact C1, Test 1: 1,8 V - 3 V . 40
5.2.2.3.1 Definition and applicability . 40
5.2.2.3.2 Conformance requirement . 40
5.2.2.3.3 Reference . 40
5.2.2.3.4 Test purpose . 40
5.2.2.3.5 Method of test . 40
5.2.2.3.6 Acceptance criteria . 41
5.2.2.4 Electrical tests on contact C1, Test 2: 1,8 V - 3 V . 41
5.2.2.4.1 Definition and applicability . 41
5.2.2.4.2 Conformance requirement . 41
5.2.2.4.3 Reference . 41
5.2.2.4.4 Test purpose . 41
5.2.2.4.5 Method of test . 41
5.2.2.4.6 Acceptance criteria . 43
5.2.3 Electrical tests on contact C2 (Reset - RST) . 43
5.2.3.1 Electrical tests on contact C2: 3 V - 5 V . 43
5.2.3.1.1 Definition and applicability . 43
5.2.3.1.2 Conformance requirement . 43
5.2.3.1.3 Reference . 43
5.2.3.1.4 Test purpose . 43
5.2.3.1.5 Method of test . 43
5.2.3.1.6 Acceptance criteria . 43
5.2.3.2 Electrical tests on contact C2: 1,8 V - 3 V . 44
5.2.3.2.1 Definition and applicability . 44
5.2.3.2.2 Conformance requirement . 44
5.2.3.2.3 Reference . 44
5.2.3.2.4 Test purpose . 44
5.2.3.2.5 Method of test . 44
5.2.3.2.6 Acceptance criteria .
...