Technical Specification
Access, Terminals, Transmission and Multiplexing (ATTM);
External Common Power Supply for
Customer Premises Network and Access Equipment;
Part 4: CPS Type 2.b implementation details

2 ETSI TS 102 874-4 V1.1.1 (2010-12)

Reference
DTS/ATTM-02011-4
Keywords
connector, EMC, power supply, terminal
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2010.
All rights reserved.
TM TM TM TM
DECT , PLUGTESTS , UMTS , TIPHON , the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered
for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
LTE™ is a Trade Mark of ETSI currently being registered
for the benefit of its Members and of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
3 ETSI TS 102 874-4 V1.1.1 (2010-12)
Contents
Intellectual Property Rights . 7
Foreword . 7
Introduction . 7
1 Scope . 9
2 References . 9
2.1 Normative references . 9
2.2 Informative references . 10
3 Definitions and abbreviations . 11
3.1 Definitions . 11
3.2 Abbreviations . 11
4 Electrical Specifications . 12
4.1 Input Requirements . 12
4.2 Output Requirement . 12
4.2.1 Output Voltage, Current And Ripple . 12
4.2.2 Short Circuit Protection And Over Current Protection . 12
4.2.3 Output Over Voltage Protection . 12
4.2.4 Output Polarity . 13
4.3 Performance Requirement . 13
4.3.1 Efficiency . 13
4.3.2 Turn On Delay Time . 13
4.3.3 Hold-up Time . 13
4.3.4 Brown-out and recovery . 13
4.3.5 Dynamic Load . 14
4.3.6 Max Open Circuit Voltage . 14
4.3.7 Overshoot at turn on/Turn off . 14
4.3.8 Output transient response/Transient load slew . 14
4.3.9 Rise time . 14
5 Operational, Storage and Transportation Requirements. 14
5.1 Temperature and Humidity. 14
6 EMC, safety and Environmental requirements . 15
6.1 EMC Specification . 15
6.1.1 CISPR Requirements . 15
6.1.2 AC Input Voltage Periodic and random disturbances . 15
6.1.3 Electrostatic Discharge (ESD) . 15
6.1.4 Lightning Surge . 15
6.1.5 Harmonic Current . 15
6.1.6 Harmonic Distortion Susceptibility . 15
6.2 Product Safety . 15
6.2.1 Safety Approval . 16
6.2.2 Leakage Current . 16
6.2.3 Dielectric voltage withstand . 16
6.3 Environmental and Eco-Design Requirements . 16
7 Reliability . 16
7.1 Burn-in . 16
7.2 MTBF Calculation . 16
7.3 Quality classes . 17
8 Mechanical Specification . 17
8.1 AC plug . 17
8.2 DC cord . 17
8.3 Label specification . 18
ETSI
4 ETSI TS 102 874-4 V1.1.1 (2010-12)
9 PLT filters to limit interference and improve coexistence . 18
Annex A (normative): Tests Plans and Procedures . 19
A.1 Overview of Tests . . 19
A.1.1 Test Equipment . 20
A.2 Performance test . 20
A.2.1 Test purpose . 20
A.2.2 Test Condition . 20
A.2.3 Test Criteria . 20
A.2.4 Results report examples . 20
A.3 Switcher Loop Stability Test . 22
A.3.1 Test Purpose . 22
A.3.2 Test Condition . 22
A.3.3 Test Criteria . 23
A.3.4 Results report example . 23
A.4 Internal Thermal Profile . 23
A.4.1 Test Purpose . 23
A.4.2 Test Condition . 23
A.4.3 Test Criteria . 23
A.4.4 Results report example . 24
A.5 External Thermal Profile . 24
A.5.1 Test Purpose . 24
A.5.2 Test Condition . 24
A.5.3 Test Criteria . 24
A.5.4 Results report example . 25
A.6 Life test . 25
A.6.1 Test Purpose . 25
A.6.2 Test Condition . 25
A.6.3 Test Criteria . 25
A.6.4 Results report example . 26
A.7 Dynamic load switching test . 26
A.7.1 Test Purpose . 26
A.7.2 Test Condition . 26
A.7.3 Test Criteria . 26
A.7.4 Results report example . 27
A.8 Output trans response-load slew and step . 27
A.8.1 Test Purpose . 27
A.8.2 Test Condition . 27
A.8.3 Test Criteria . 27
A.8.4 Results report example . 27
A.9 AC input inrush current test . 27
A.9.1 Test Purpose . 27
A.9.2 Test Condition . 27
A.9.3 Test Criteria . 28
A.9.4 Results report example . 28
A.10 Turn on delay test . . 28
A.10.1 Test Purpose . 28
A.10.2 Test Condition . 28
A.10.3 Test Criteria . 28
A.10.4 Results report example . 28
A.11 Output hold-up time test . 29
A.11.1 Test Purpose . 29
A.11.2 Test Condition . 29
A.11.3 Test Criteria . 29
A.11.4 Results report example . 29
ETSI
5 ETSI TS 102 874-4 V1.1.1 (2010-12)
A.12 Rise time and overshoot test . 29
A.12.1 Test Purpose . 29
A.12.2 Test Condition . 29
A.12.3 Test Criteria . 30
A.12.4 Results report example . 30
A.13 Output transient response deviation test . 30
A.13.1 Test Purpose . 30
A.13.2 Test Condition . 30
A.13.3 Test Criteria . 30
A.13.4 Results report example . 31
A.14 Dynamic load test . 31
A.14.1 Test Purpose . 31
A.14.2 Test Condition . 31
A.14.3 Test Criteria . 31
A.14.4 Results report example . 31
A.15 Brown out and recovery test . 32
A.15.1 Test Purpose . 32
A.15.2 Test Condition . 32
A.15.3 Test Criteria . 32
A.15.4 Results report example . 32
A.16 Temperature storage test . 32
A.16.1 Test Purpose . 32
A.16.2 Test Condition . 32
A.16.3 Test Criteria . 33
A.16.4 Results report example . 33
A.17 Humidity storage test. 33
A.17.1 Test Purpose . 33
A.17.2 Test Condition . 33
A.17.3 Test Criteria . 34
A.17.4 Results report example . 34
A.18 Power cycle test . 34
A.18.1 Test Purpose . 34
A.18.2 Test Condition . 34
A.18.3 Test Criteria . 34
A.18.4 Results report example . 34
A.19 Shipping, single drop, vibration test . 34
A.19.1 Test Purpose . 34
A.19.2 Test Condition . 34
A.19.3 Test Criteria . 35
A.19.4 Results report example . 36
A.20 Short circuit protection test . 36
A.20.1 Test Purpose . 36
A.20.2 Test Condition . 36
A.20.3 Test Criteria . 36
A.20.4 Results report example . 36
A.21 Over voltage protection test . 37
A.21.1 Test Purpose . 37
A.21.2 Test Condition . 37
A.21.3 Test Criteria . 37
A.21.4 Results report example . 37
A.22 Over current protection test . 37
A.22.1 Test Purpose . 37
A.22.2 Test Condition . 37
A.22.3 Test Criteria . 38
A.22.4 Results report example . 38
ETSI
6 ETSI TS 102 874-4 V1.1.1 (2010-12)
A.22.5 Test purpose . 38
A.22.6 Test Condition . 38
A.22.7 Test Criteria . 38
A.22.8 Results report example . 39
A.23 Hi-Pot test . 39
A.23.1 Test Purpose . 39
A.23.2 Test Condition . 39
A.23.3 Test Criteria . 39
A.23.4 Results report example . 39
A.24 Dielectric withstand test . . 40
A.24.1 Test Purpose . 40
A.24.2 Test Condition . 40
A.24.3 Test Criteria . 40
A.24.4 Results report example . 40
A.25 Leakage current test. 40
A.25.1 Test Purpose . 40
A.25.2 Test Condition . 40
A.25.3 Test Criteria . 40
A.25.4 Results report example . 41
A.26 DC cord set and plug test . 41
A.26.1 Test Purpose . 41
A.26.2 Test Condition 1 . 41
A.26.3 Test Condition 2 . 41
A.26.4 Test Criteria . 41
A.26.5 Results report example . 42
A.27 Energy efficiency test . 42
A.27.1 Test Purpose . 42
A.27.2 Test Condition . 42
A.27.3 Test Criteria . 42
A.27.4 Results report example . 42
A.28 Capacitive load test . 43
A.28.1 Test Purpose . 43
A.28.2 Test Condition . 43
A.28.3 Test Criteria . 43
A.28.4 Results report example . 43
A.29 Maximum open circuit voltage test . 43
A.29.1 Test Purpose . 43
A.29.2 Test Condition . 43
A.29.3 Test Criteria . 43
A.29.4 Results report example . 44
A.30 Other tests . 44
Annex B (informative): Testing immunity of PLT equipment to CPS disturbances . 45
B.1 Test Purpose . 45
B.1.1 Test Condition . 45
B.1.2 Test Criteria . 45
B.1.3 Results report example . 45
Annex C (informative): Bibliography . 46
History . 47

ETSI
7 ETSI TS 102 874-4 V1.1.1 (2010-12)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This Technical Specification (TS) has been produced by ETSI Technical Committee Access, Terminals, Transmission
and Multiplexing (ATTM).
The present document is part 4 of a multi-part deliverable covering the External Common Power Supply for Customer
Premises Network and Access Equipment, as identified below:
ES 202 874-1: "Functional requirements";
TS 102 874-2: "Integrated Broadband Cable and Television Networks";
TS 102 874-3: "CPS Type 1 implementation details";
TS 102 874-4: "CPS Type 2.b implementation details";
TS 102 874-5: "CPS Type 2.c implementation".
Introduction
The present document is part of a multi-part deliverable covering External Common Power Supply (CPS) for Customer
Premises Network and Access Equipment.
This multi-part deliverable represents a set of cohesive interwoven technical information that has jointly evolved to
define solution of most efficient equipment, as defined below:
• ES 202 874-1 [i.1] defines functional requirements for four different categories of CPS.
• TS 102 874-2 [i.2] defines detailed implementation and operational aspects for CPS Type 2.a.
• TS 102 874-3 [i.3] defines detailed implementation and operational aspects for CPS Type 1.
• TS 102 874-4 (the present document) defines detailed implementation and operational aspects for CPS
Type 2.b.
• TS 102 874-5 [i.4] defines detailed implementation and operational aspects for CPS Type 2.c.
The intended applications of these CPS categories are specified in ES 202 874-1 [i.1].
ETSI
8 ETSI TS 102 874-4 V1.1.1 (2010-12)
Table 1 summarizes the structure of the present document.
Table 1: Multi-part deliverable structure
CPS category Functional requirements Implementation aspects
Type 1: 5V, 2A TS 102 874-3 [i.3]
Type 2.a: 12V, 1A TS 102 874-2 [i.2]
ES 202 874-1 [i.1]
Type 2.b: 12V, 2A TS 102 874-4
Type 2.c: 12V, 5A TS 102 874-5 [i.4]

The present document addresses the implementation details of the External Common Power Supply (CPS) for Customer
Premises Network and Access Equipment - Type 2.b, rated to a maximum of 12V dc and a maximum current of 2Amp
for use with CPEs, set top boxes and other customer network devices with similar power needs.
Other methods for providing power to end devices are not in the scope of the document (e.g. Power Over Ethernet,
power on USB, etc.).
Test are specified to verify the compliance of the external power supply against the requirements given by the present
specification.
The present document specifies design requirements and tests to ensure compliance of the CPS as well as reference to
relevant European Directives including power efficiency on-load and no-load requirements given by European
Commission Regulation No 278/2009 of 6 April 2009 [1].
ETSI
9 ETSI TS 102 874-4 V1.1.1 (2010-12)
1 Scope
The present document describes the specification for a high performance External Power Supply Unit for powering the
Customer Premises Equipment to a maximum voltage rating of 12V dc.
The specifications define the input, output characteristics and performance requirements for a switching mode AC to
DC CPS rated to a maximum 12V dc, and maximum 2 A.
The present document also specifies tests to verify the compliance of the external CPS.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC
of the European Parliament and of the Council with regard to ecodesign requirements for no-load
condition electric power consumption and average active efficiency of external power supplies.
[2] CENELEC EN 55022:2006 (+ Amendment 1: 2007): "Information technology equipment - Radio
disturbance characteristics - Limits and methods of measurement".
[3] CISPR 22: "Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement".
[4] CENELEC EN 61000-3-2: "Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for
harmonic current emissions (equipment input current <= 16 A per phase)".
[5] CENELEC EN 61000-4-2: "Electromagnetic compatibility (EMC) -- Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[6] CENELEC EN 61000-4-4: "Electromagnetic compatibility (EMC) -- Part 4-4: Testing and
measurement techniques - Electrical fast transient/burst immunity test".
[7] CENELEC EN 61000-4-5: "Electromagnetic compatibility (EMC) -- Part 4-5: Testing and
measurement techniques - Surge immunity test".
[8] CENELEC EN 61000-4-11: "Electromagnetic compatibility (EMC) -- Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[9] CENELEC EN 61000-4-12: "Electromagnetic compatibility (EMC) -- Part 4-12: Testing and
measurement techniques - Ring wave immunity test".
[10] Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the
restriction of the use of certain hazardous substances in electrical and electronic equipment.
[11] Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste
electrical and electronic equipment (WEEE) (ROHS Directive and amendments).
ETSI
10 ETSI TS 102 874-4 V1.1.1 (2010-12)
[12] CENELEC EN 60950-1: "Information technology equipment - Safety -- Part 1: General
requirements".
[13] CENELEC EN 50075: "Flat non-rewirable two-pole plugs, 2,5 A 250 V, with cord, for the
connection of class II-equipment for household and similar purposes".
[14] Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the
harmonisation of the laws of Member States relating to electrical equipment designed for use
within certain voltage limits (LVD directive).
[15] Council Directive 93/68/EEC (CE Marketing) of 22 July 1993 amending Directives 87/404/EEC
(simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products),
89/336/EEC (electromagnetic compatibility), 89/392/EEC (machinery), 89/686/EEC (personal
p
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...