General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.XQNFLRQDOQRVWTransmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 5-1: Plesiochronous Digital Hierarchy (PDH) path layer functions33.040.20Prenosni sistemTransmission systemsICS:Ta slovenski standard je istoveten z:EN 300 417-5-1 Version 1.1.2SIST EN 300 417-5-1 V1.1.2:2003en01-december-2003SIST EN 300 417-5-1 V1.1.2:2003SLOVENSKI
STANDARD
SIST EN 300 417-5-1 V1.1.2:2003
EN 300 417-5-1 V1.1.2 (1998-11)European Standard (Telecommunications series)Transmission and Multiplexing (TM);Generic requirements of transport functionality of equipment;Part 5-1: Plesiochronous Digital Hierarchy (PDH)path layer functionsSIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)2ReferenceREN/TM-01015-5-1 (3v199idc.PDF)KeywordsPDH, SDH, transmission, transport, pathETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1998.All rights reserved.SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)3ContentsIntellectual Property Rights.7Foreword.7Introduction.81Scope.92References.93Definitions, abbreviations and symbols.103.1Definitions.103.2Abbreviations.103.3Symbols and Diagrammatic Conventions.134P4e path layer functions.144.1P4e connection functions.164.2P4e trail termination functions.174.2.1P4e trail termination source P4e_TT_So.174.2.2P4e trail termination sink P4e_TT_Sk.184.3P4e adaptation functions.204.3.1P4e to P31x adaptation source P4e/P31x_A_So/i.204.3.2P4e to P31x Adaptation Sink P4e/P31x_A_Sk/i.224.3.3P4e to P31e adaptation source P4e/P31e_A_So/i.244.3.4P4e to P31e adaptation sink P4e/P31e_A_Sk/i.264.3.5P4e to P31s adaptation source P4e/P31s_A_So/i.284.3.6P4e to P31s adaptation sink P4e/P31s_A_Sk/i.304.4P4e layer monitoring functions.334.4.1P4e layer non-intrusive monitoring function P4em_TT_Sk.334.5P4e PDH equipment clock adaptation source P4e_PEC.355P31e path layer functions.365.1P31e connection functions.375.2P31e trail termination functions.385.2.1P31e trail termination source P31e_TT_So.385.2.2P31e trail termination sink P31e_TT_Sk.395.3P31e adaptation functions.415.3.1P31e to P22x adaptation source P31e/P22x_A_So/i.415.3.2P31e to P22x adaptation sink P31e/P22x_A_Sk/i.435.3.3P31e to P22e adaptation source P31e/P22e_A_So/i.455.3.4P31e to P22e adaptation sink P31e/P22e_A_Sk/i.475.4P31e layer monitoring functions.495.4.1P31e layer non-intrusive monitoring function P31em_TT_Sk.495.5P31e PDH equipment clock adaptation source P31e_PEC.516P22e path layer functions.526.1P22e connection functions.536.2P22e trail termination functions.546.2.1P22e trail termination source P22e_TT_So.546.2.2P22e trail termination sink P22e_TT_Sk.556.3P22e adaptation functions.576.3.1P22e to P12x adaptation source P22e/P12x_A_So/i.576.3.2P22e to P12x adaptation sink P22e/P12x_A_Sk/i.596.3.3P22e to P12s adaptation source P22e/P12s_A_So/i.616.3.4P22e to P12s adaptation sink P22e/P12s_A_Sk/i.636.4P22e layer monitoring functions.656.4.1P22e layer non-intrusive monitoring function P22em_TT_Sk.656.5P22e PDH equipment clock adaptation source P22e_PEC.67SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)47P12s path layer functions.687.1P12s connection functions.717.2P12s trail termination functions.717.2.1P12s trail termination source P12s_TT_So.717.2.2P12s trail termination sink P12s_TT_Sk.737.3P12s adaptation functions.767.3.1P12s to P0-31c adaptation source P12s/P0-31c_A_So.767.3.2P12s to P0-31c adaptation sink P12s/P0-31c_A_Sk.777.3.3P12s to SD adaptation source P12s/SD_A_So.787.3.4P12s to SD adaptation sink P12s/SD_A_Sk.787.3.5P12s to ATM VP compound adaptation source P12s/Avp_A_So.787.3.6P12s to ATM VP compound adaptation sink P12s/Avp_A_Sk.787.3.7P12s Layer Clock adaptation source P12s-LC_A_So.787.4P12s layer monitoring functions.787.4.1P12s layer non-intrusive monitoring function P12sm_TT_Sk.788P31s path layer functions.818.1P31s connection functions.828.2P31s trail termination functions.828.2.1P31s trail termination source P31s_TT_So.828.2.2P31s trail termination sink P31s_TT_Sk.848.3P31s adaptation functions.868.3.1P31s layer to VC-12, VC-11 layer compound adaptation source function P31s/SX_A_So.868.3.1.1P31s layer to TUG adaptation source function P31s/TUG_A_So.878.3.1.2TUG termination source function TUG_T_So.908.3.1.3TUG to VC-12 layer adaptation source function TUG/S12_A_So/M.918.3.1.4TUG to VC-11 layer adaptation source function TUG/S11_A_So/M.948.3.2P31s layer to VC-12, VC-11 layer compound adaptation sink function P31s/SX_A_Sk.978.3.2.1P31s layer to TUG adaptation sink function P31s/TUG_A_Sk.988.3.2.2TUG termination sink function TUG_T_Sk.1008.3.2.3TUG to VC-12 layer adaptation sink function TUG/S12_A_Sk/M.1018.3.2.4TUG to VC-11 layer adaptation sink function TUG/S11*_A_Sk/M.1038.3.3P31s layer to P0s layer adaptation source P31s/P0s_A_So.1058.3.4P31s layer to P0s layer adaptation sink P31s/P0s_A_Sk.1068.3.5P31s to V0x adaptation source P31s/V0x_A_So.1078.3.6P31s to V0x adaptation sink P31s/V0x_A_Sk.1088.3.7P31s to DCC adaptation source P31s/DCC_A_So.1098.3.8P31s to DCC adaptation sink P31s/DCC_A_Sk.1108.3.9P31s to SD adaptation source P31s/SD_A_So.1118.3.10P31s to SD adaptation sink P31s/SD_A_Sk.1118.3.11P31s to ATM VP compound adaptation source P31s/Avp_A_So.1118.3.12P31s to ATM VP compound adaptation sink P31s/Avp_A_Sk.1118.3.13P31s Layer Clock adaptation source P31s-LC_A_So.1118.4P31s layer monitoring functions.1128.4.1P31s non-intrusive monitoring function P31sm_TT_Sk.1128.5P31s layer trail protection functions.1148.6P31s tandem connection sublayer functions.1148.6.1P31s tandem connection trail termination source function (P31sD_TT_So).1148.6.2P31s tandem connection trail termination sink function (P31sD_TT_Sk).1178.6.3P31s tandem connection to p31s adaptation source function (P31sD/P31s_A_So).1228.6.4P31s tandem connection to p31s adaptation sink function (P31sD/P31s_A_Sk).1238.6.5P31s tandem connection non-intrusive trail termination sink function (P31sDm_TT_Sk).1249P4s path layer functions.1289.1P4s connection functions.1299.2P4s trail termination functions.1309.2.1P4s trail termination source P4s_TT_So.1309.2.2P4s trail termination sink P4s_TT_Sk.1329.3P4s adaptation functions.1349.3.1P4s layer to VC-3, VC-2, VC-12, and VC-11 layer compound adaptation source function P4s/SX-TUG3_A_So.134SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)59.3.1.1P4s layer to TUG3 adaptation source function P4s/TUG3_A_So.1359.3.1.2TUG3 trail termination source function TUG3_T_So.1389.3.1.3TUG3 to VC-3 layer adaptation source function TUG3/S3_A_So/K.0.0.1399.3.1.4TUG3 to VC-2 layer adaptation source function TUG3/S2_A_So/K.L.0.1419.3.1.5TUG3 to VC-12 layer adaptation source function TUG3/S12_A_So/K.L.M.1449.3.1.6TUG3 to VC-11 layer adaptation source function TUG3/S11*_A_So/K.L.M.1479.3.2P4s layer to VC-3, VC-2, VC-12, and VC-11 layer compound adaptation sink function P4s/SX-TUG3_A_Sk.1509.3.2.1P4s layer to TUG3 adaptation sink function P4s/TUG3_A_Sk.1529.3.2.2TUG3 trail termination sink function TUG3_T_Sk.1549.3.2.3TUG3 to VC-3 layer adaptation sink function TUG3/S3_A_Sk/K.0.0.1559.3.2.4TUG3 to VC-2 layer adaptation sink function TUG3/S2_A_Sk.1579.3.2.5TUG3 to VC-12 layer adaptation sink function TUG3/S12_A_Sk/K.L.M.1599.3.2.6TUG3 to VC-11 layer adaptation sink function TUG3/S11*_A_Sk/K.L.M.1619.3.3P4s layer to VC-2, VC-12, and VC-11 layer compound adaptation source function P4s/SX-TUG2_A_So.1639.3.3.1P4s layer to TUG2 adaptation source function P4s/TUG2_A_So.1649.3.3.2TUG2 trail termination source function TUG2_T_So.1669.3.3.3TUG2 to VC-2 layer adaptation source function TUG2/S2_A_So/L.0.1679.3.3.4TUG2 to VC-12 layer adaptation source function TUG2/S12_A_So/L.M.1709.3.3.5TUG2 to VC-11 layer adaptation source function TUG2/S11*_A_So/L.M.1739.3.4P4s layer to VC-2, VC-12, and VC-11 layer compound adaptation sink function P4s/SX-TUG2_A_Sk.1769.3.4.1P4s layer to TUG2 adaptation sink function P4s/TUG2_A_Sk.1789.3.4.2TUG2 trail termination sink function TUG2_T_Sk.1809.3.4.3TUG2 to VC-2 layer adaptation sink function TUG2/S2_A_Sk/L.0.1819.3.4.4TUG2 to VC-12 layer adaptation sink function TUG2/S12_A_Sk/L.M.1839.3.4.5TUG2 to VC-11 layer adaptation sink function TUG2/S11*_A_Sk/L.M.1859.3.5P4s layer to P0s layer adaptation source P4s/P0s_A_So.1879.3.6P4s layer to P0s layer adaptation sink P4s/P0s_A_Sk.1889.3.7P4s to V0x adaptation source P4s/V0x_A_So.1899.3.8P4s to V0x adaptation sink P4s/V0x_A_Sk.1909.3.9P4s to DCC adaptation source P4s/DCC_A_So.1919.3.10P4s to DCC adaptation sink P4s/DCC_A_Sk.1929.3.11P4s to SD adaptation source P4s/SD_A_So.1939.3.12P4s to SD adaptation sink P4s/SD_A_Sk.1939.3.13P4s to ATM VP compound adaptation source P4s/Avp_A_So.1939.3.14P4s to ATM VP compound adaptation sink P4s/Avp_A_Sk.1939.3.15P4s Layer Clock adaptation source P4s-LC_A_So.1939.4P4s layer monitoring functions.1949.4.1P4s non-intrusive monitoring function P4sm_TT_Sk.1949.5P4s layer trail protection functions.1959.6P4s tandem connection sublayer functions.1969.6.1P4s tandem connection trail termination source function (P4sD_TT_So).1969.6.2P4s tandem connection trail termination sink function (P4sD_TT_Sk).1999.6.3P4s tandem connection to p4s adaptation source function (P4sD/P4s_A_So).2049.6.4P4s tandem connection to p4s adaptation sink function (P4sD/P4s_A_Sk).2059.6.5P4s tandem connection non-intrusive trail termination sink function (P4sDm_TT_Sk).206SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)610P4x path layer functions.20911P32x path layer functions.20912P31x path layer functions.20913P22x path layer functions.20914P12x path layer functions.20915P11x path layer functions.20916P0s path layer functions.21017P0-31c path layer functions.210Annex A (informative):Relationship between TU-2/12 address, and location of columnswithin a P4s TUG3 structured payload.211Annex B (informative):Relationship between TU-2/12 address, and location of columnswithin a P4s TUG2 structured payload.214Annex C (informative):Bibliography.217History.218SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)7Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available free of charge from the ETSI Secretariat. Latest updates are available on theETSI Web server (http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical Committee Transmissionand Multiplexing (TM).The present document is one of a family of documents that has been produced in order to provide inter-vendor andinter-operator compatibility of Synchronous Digital Hierarchy (SDH) equipment.The present document is part 5-1 of a multi-part EN covering the Generic requirements of transport functionality ofequipment, as identified below:Part 1-1:"Generic processes and performance".Part 1-2:"General information about Implementation Conformance Statement (ICS) proforma".Part 1-3 "Generic processes and performance; Abstract Test Suite (ATS)".Part 2-1:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions".Part 2-2:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions; Implementation Conformance Statement (ICS) proforma specification".Part 2-3:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions; Abstract Test Suite (ATS)".Part 3-1:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions".Part 3-2:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions;Implementation Conformance Statement (ICS) proforma specification".Part 3-3:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions; AbstractTest Suite (ATS)".Part 4-1:"Synchronous Digital Hierarchy (SDH) path layer functions".Part 4-2:"Synchronous Digital Hierarchy (SDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 4-3:"Synchronous Digital Hierarchy (SDH) path layer functions; Abstract Test Suite (ATS)".Part 5-1:"Plesiochronous Digital Hierarchy (PDH) path layer functions".Part 5-2:"Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 5-3:"Plesiochronous Digital Hierarchy (PDH) path layer functions; Abstract Test Suite (ATS)".Part 6-1:"Synchronization layer functions".SIST EN 300 417-5-1 V1.1.2:2003
ETSIEN 300 417-5-1 V1.1.2 (1998-11)8Part 6-2:"Synchronization layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 6-3:"Synchronization layer functions; Abstract Test Suite (ATS)".Part 7-1:"Auxiliary layer functions".Part 7-2:"Auxiliary layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 7-3:"Auxiliary layer functions; Abstract Test Suite (ATS)".Parts 2 to 7 specify the layers and their atomic functions.NOTE 1:The present document does not currently address configuration management.NOTE 2:The SDH radio equipment functional blocks are addressed by ETSI WG TM4.Various of the above parts have previously been published as parts of ETS 300 417.They have been converted to parts of EN 300 417 without technical changes, but some editorial changes have beennecessary (e.g. references). In particular:-Parts 2-1 and 3-2 have been modified to take account of editorial errors present in edition 1.-Part 1-1 has had its title change of to align with other parts published at a later date.Also note that in the meantime parts 8-1, 8-2 and 8-3 have been stopped.Transposition datesDate of adoption of this EN:6 March 1998Date of latest announcement of this EN (doa):30 June 1998Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 December 1998Date of withdrawal of any conflicting National Standard (dow):31 December 1998IntroductionThe atomic PDH path layer functions are defined below used in plesiochronous and synchronous operation. Theydescribe the functionality of PDH multiplex equipments described in the CCITT Recommendations G.751 [6] andG.742 [5] for signal hierarchies P4e, P31e and P22e. In addition they desc
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.