Digital Enhanced Cordless Telecommunications (DECT); Cordless Terminal Mobility (CTM); CTM Access Profile (CAP); Profile Test Specification (PTS); Part 3: Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)

DEN/DECT-040120-3

Digitalne izboljšane brezvrvične telekomunikacije (DECT) - Mobilnost brezvrvičnega terminala (CTM) - Profil dostopa CTM (CAP) - Profil preskuševalne specifikacije (PTS) - 3. del: Preskuševalna specifikacija, odvisna od profila (PSTS) - Fiksna radijska zaključitev (FT)

General Information

Status
Published
Publication Date
08-Sep-1999
Technical Committee
Current Stage
12 - Completion
Due Date
30-Aug-1999
Completion Date
09-Sep-1999
Mandate

Buy Standard

Standard
P EN 301 371-3:1999
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 301 371-3:2001
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.RVWDigital Enhanced Cordless Telecommunications (DECT); Cordless Terminal Mobility (CTM); CTM Access Profile (CAP); Profile Test Specification (PTS); Part 3: Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)33.070.30'(&7Digital Enhanced Cordless Telecommunications (DECT)ICS:Ta slovenski standard je istoveten z:EN 301 371-3 V0.0.33SIST EN 301 371-3:en01-GHFHPEHU3SIST EN 301 371-3:SLOVENSKI
STANDARD



SIST EN 301 371-3:2001



ETSI EN 301 371-3 V0.0.3 (1999-09)European Standard (Telecommunications series)Digital Enhanced Cordless Telecommunications (DECT);Cordless Terminal Mobility (CTM);CTM Access Profile (CAP);Profile Test Specification (PTS);Part 3: Profile Specific Test Specification (PSTS) -Fixed radio Termination (FT)SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)2ReferenceDEN/DECT-040120-3 (cp0r0020.PDF)KeywordsCAP, CTM, DECT, FT, testingETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)3ContentsIntellectual Property Rights.5Foreword.51Scope.62References.63Definitions and abbreviations.83.1Definitions.83.2Abbreviations.84Relevant test cases list.94.1Network (NWK) layer.94.1.1Test suite structure (TSS).104.1.2Test case index.124.2Data Link Control (DLC) layer.134.3Medium Access Control (MAC) layer.134.3.1Test suite structure.134.3.2Test case index.144.4Physical (PH) layer.145Additional test cases list.145.1Test purposes.145.1.1NWK layer.145.1.2DLC layer.145.1.3MAC layer.145.1.4PH layer.145.2Test cases.145.2.1NWK layer.155.2.2DLC layer.155.2.3MAC layer.155.2.4PH layer.15Annex A (normative):Profile Implementation eXtra Information for Testing (IXIT)proforma.16A.1General.16A.2Profile IXIT Requirements List (XRL).16A.2.1NWK layer protocol.16A.2.2DLC layer protocol.16A.2.3MAC layer protocol.16A.2.4PH layer protocol.16A.3Profile specific IXIT.17A.3.1NWK layer.17A.3.2DLC layer.17A.3.3MAC layer.17A.3.4PH layer.17A.3.5Configuration constraints.17Annex B (normative):Profile Conformance Test Report (PCTR) proforma.18B.1Identification summary.18B.1.1Profile CTR.18B.1.2Implementation Under Test (IUT).18B.1.3Testing environment.19B.1.4Limits and reservations.19B.1.5Comments.19SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)4B.2IUT conformance status.19B.3Static conformance summary.20B.4Dynamic conformance summary.20B.5Static conformance review report.20B.6Test campaign report.21B.6.1NWK layer.21B.6.2DLC layer.21B.6.3MAC layer.21B.6.4PH layer.21B.7Observations.22Annex C (normative):System Conformance Test Report (SCTR) proforma.23C.1Identification summary.23C.1.1System Conformance Test Report (SCTR).23C.1.2Test laboratory.23C.1.3Client.24C.1.4System Under Test (SUT).24C.1.5Profile.24C.1.6Nature of conformance testing.25C.1.7Limits and reservations.25C.1.8Record of agreement.25C.1.9Comments.25C.2System report summary.26C.2.1Profile testing summary for CAP NWK layer FT.26C.2.2Profile testing summary for CAP DLC layer FT.26C.2.3Profile testing summary for CAP MAC layer FT.27C.2.4Profile testing summary for CAP PH layer FT.27Annex D (normative):System Conformance Statement (SCS) proforma.28D.1Identification summary.28D.1.1SCS identification.28D.1.2IUT identification.28D.1.3Client identification.29D.1.4Supplier identification.29D.1.5Manufacturer identification.30D.1.6Protocols identification.30D.1.7Profile identification.30D.2Miscellaneous system information.31D.2.1Configuration.31D.2.2Other information.31Bibliography.32History.33SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)5Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server(http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Project Digital Enhanced CordlessTelecommunications (DECT).The CTM Access Profile (CAP) Profile Test Specification (PTS) comprises three parts:Part 1:"Summary";Part 2:"Profile Specific Test Specification (PSTS) - Portable radio Termination (PT)";Part 3:"Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)".National transposition datesDate of adoption of this EN:27 August 1999Date of latest announcement of this EN (doa):30 November 1999Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 May 2000Date of withdrawal of any conflicting National Standard (dow):31 May 2000SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)61ScopeThe present document contains the test specification for Digital Enhanced Cordless Telecommunications (DECT) CTMAccess Profile (CAP) Fixed Part (FP) applications.The main objective of the CAP test specification is to provide approval tests giving a high probability of air interfaceinter-operability between different manufacturer's equipment in different environments (i.e. public, business andresidential).The ISO standard for the methodology of conformance testing ISO/IEC 9646 Parts 1 [24] to 7 [30] is used as the basisfor the test methodology, and as the basis for the test case specification. This is considered to be unsuitable for Physicallayer testing, and therefore a text description is used.The test cases listed in the present document have been derived from the DECT Common Interface (CI) Test CaseLibrary (TCL) [14] to [22]. In addition as far as the Physical layer is concerned EN 300 176 [10] applies. AdditionalCAP specific test cases are included where required. The Profile IXIT is based on the DECT CI PIXITs specified inEN 300 497 [14] to [22].2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]EN 301 371-1: "Digital Enhanced Cordless Telecommunications (DECT); Cordless TerminalMobility (CTM); CTM Access Profile (CAP); Profile Test Specification (PTS); Part 1: Summary".[2]Void.[3]EN 300 175-1: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 1: Overview".[4]EN 300 175-2: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 2: Physical Layer (PHL)".[5]EN 300 175-3: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 3: Medium Access Control (MAC) layer".[6]EN 300 175-4: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 4: Data Link Control (DLC) layer".[7]EN 300 175-5: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 5: Network (NWK) layer".[8]EN 300 175-6: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 6: Identities and addressing".[9]EN 300 175-7: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 7: Security features".SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)7[10]EN 300 176: "Digital Enhanced Cordless Telecommunications (DECT); Approval testspecification".[11]EN 300 444: "Digital Enhanced Cordless Telecommunications (DECT); Generic Access Profile(GAP)".[12]ETS 300 476 (all parts): "Digital Enhanced Cordless Telecommunications (DECT); CommonInterface (CI); Protocol Implementation Conformance Statement (PICS) proforma".[13]EN 300 494-3: "Digital Enhanced Cordless Telecommunications (DECT); Generic Access Profile(GAP); Part 3: Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)".[14]EN 300 497-1: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 1: Test Suite Structure (TSS) and Test Purposes (TP) for MediumAccess Control (MAC) layer".[15]EN 300 497-2: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 2: Abstract Test Suite (ATS) for Medium Access Control (MAC)layer - Portable radio Termination (PT)".[16]EN 300 497-3: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 3: Abstract Test Suite (ATS) for Medium Access Control (MAC)layer - Fixed radio Termination (FT)".[17]EN 300 497-4: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 4: Test Suite Structure (TSS) and Test Purposes (TP) - Data LinkControl (DLC) layer".[18]EN 300 497-5: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 5: Abstract Test Suite (ATS) - Data Link Control (DLC) layer".[19]EN 300 497-6: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 6: Test Suite Structure (TSS) and Test Purposes (TP) - Network(NWK) layer - Portable radio Termination (PT)".[20]EN 300 497-7: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 7: Abstract Test Suite (ATS) for Network (NWK) layer - Portableradio Termination (PT)".[21]EN 300 497-8: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 8: Test Suite Structure (TSS) and Test Purposes (TP) - Network(NWK) layer - Fixed radio Termination (FT)".[22]EN 300 497-9: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 9: Abstract Test Suite (ATS) for Network (NWK) layer - Fixedradio Termination (FT)".[23]EN 300 824: "Digital Enhanced Cordless Telecommunications (DECT); Cordless TerminalMobility (CTM); CTM Access Profile (CAP)".[24]ISO/IEC 9646-1: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 1: General concepts".[25]ISO/IEC 9646-2: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 2: Abstract Test Suite Specification".[26]ISO/IEC 9646-3: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 3: The Tree and Tabular Combined Notation (TTCN)".[27]ISO/IEC 9646-4: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 4: Test realization".SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)8[28]ISO/IEC 9646-5: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 5: Requirements on test laboratories and clients for theConformance Assessment process".[29]ISO/IEC 9646-6: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 6: Protocol Profile Test Specification".[30]ISO/IEC 9646-7: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 7: Implementation Conformance statement".3Definitions and abbreviations3.1DefinitionsFor the purposes of the present document, the following terms and definitions apply:-terms defined in ISO/IEC 9646 Parts 1 to 7 [24] to [30];-definitions in EN 300 175 Parts 1 to 7 [3] to [9];-definitions in EN 300 444 [11];-definitions in EN 300 824 [23].3.2AbbreviationsFor the purposes of the present document, the following abbreviations apply:ATSAbstract Test SuiteCAPCTM Access ProfileCCCall ControlCICommon InterfaceCTMCordless Terminal MobilityDECTDigital Enhanced Cordless TelecommunicationsDLCData Link ControlFTFixed radio TerminationGAPGeneric Access ProfileICSImplementation Conformance StatementIUTImplementation Under TestIXITImplementation eXtra Information for TestingLCELink Control EntityLLMELower Layer Management EntityMACMedium Access ControlMMMobility ManagementNWKNetworkPHPhysicalPICSProtocol Implementation Conformance StatementPIXITProtocol Implementation eXtra Information for TestingPTPortable radio TerminationPSTSProfile Specific Test SpecificationPTSProfile Test SpecificationSUTSystem Under TestSIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)94Relevant test cases list4.1Network (NWK) layerThis subclause includes lists of the test groups and abstract test cases relevant for CAP Profile Test Specification (PTS)- NWK layer Fixed Termination (FT) derived from EN 300 497-9 [22]. In addition all the test groups and abstract testcases relevant for GAP PTS, contained in EN 300 494-3 [13] shall apply.NOTE:References when necessary shall be made based on the particular test case name unique through all testspecification EN 300 497 [14] to [22].SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)104.1.1Test suite structure (TSS)Table 1Test Suite StructureSuite Name:nwk_ftStandards Ref:EN 300 824 [23]; EN 300 497-9 [22]Profile ICS Ref:DEN/DECT-040121 Profile IXIT Ref:EN 300 494-3 [13]Test Method:remoteComments:Test Group ReferenceTest Group ObjectiveFT/To check the behaviour of the NWK layer of the FT(IUT)FT/CC/To check the IUT CC-state machine behaviourFT/CC/IT/To check that the IUT CC-state machine provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/CC/CA/Limited testing that the observable capabilities of the CC entity of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/CC/BV/To test the CC entity of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/CC/BV/OC/To check the IUT's behaviours to set-up an outgoing callFT/CC/BV/IC/To check the IUT's behaviours to set-up an incoming callFT/CC/BV/CI/To check the IUT's behaviour in information transfer proceduresFT/CC/BV/CR/To check the IUT's behaviours to release an outgoing/incoming callFT/CC/BV/HP/To check the IUT's behaviour during external handover proceduresFT/CC/RSTo check the IUT's behaviour during call related supplementary service procedures.FT/CC/BO/To check the behaviour of the CC entity of the IUT in response to the messages thatare syntactically correct but not allowed to occur in some states of the CC proceduresFT/CC/BI/To check the behaviour of the CC entity of the IUT in response to invalid messagesFT/CC/TI/To verify that the IUT CC timers are with correct values and the IUT is reacting properlyto the expiry of a timerFT/MM/To check the behaviour of the Mobility Management entity of the IUTFT/MM/IT/To check that the MM entity of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/MM/CA/Limited testing that the observable capabilities of the MM entity of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/MM/BV/To test the MM entity of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/MM/BV/ID/To check the IUT's behaviour concerning identity proceduresFT/MM/BV/AU/To check the IUT's behaviour concerning the authentication proceduresFT/MM/BV/LO/To check the IUT's behaviour concerning the location proceduresFT/MM/BV/AR/To check the IUT's behaviour concerning the access rights proceduresFT/MM/BV/KA/To check the IUT's behaviour concerning the key allocation procedureFT/MM/BV/CH/To check the IUT's behaviour concerning the ciphering related proceduresFT/MM/BV/HP/To check the IUT's behaviour during external handover proceduresFT/MM/BO/To check the IUT behaviour in response to the messages that are syntactically correctbut not allowed to occur in some phase of the MM proceduresFT/MM/BI/To check the IUT in response to invalid MM messagesFT/MM/TI/To verify that the IUT MM timers are with correct values and the IUT is reacting properlyto the expiry of a timerFT/ME/To check the behaviour of the LLME of the IUTFT/ME/IT/To check that LLME of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/ME/CA/Limited testing that the observable capabilities of the LLME of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/ME/BV/To test the LLME of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/LC/To check the behaviour of the LCE of the IUTSIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)11Test Suite StructureSuite Name:nwk_ftStandards Ref:EN 300 824 [23]; EN 300 497-9 [22]Profile ICS Ref:DEN/DECT-040121 Profile IXIT Ref:EN 300 494-3 [13]Test Method:remoteComments:Test Group ReferenceTest Group ObjectiveFT/LC/IT/To check that LCE of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/LC/CA/Limited testing that the observable capabilities of the LCE of the IUT are in accordancewith the static conformance requirements and the additional capabilities claimed in thePROFILE ICS/PROFILE IXITFT/LC/BV/To test the LCE of the IUT in response to syntactically and contextual correct behaviourof the test systemFT/LC/BV/LE/To check the IUT's behaviour concerning the con
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.RVWDigital Enhanced Cordless Telecommunications (DECT); Cordless Terminal Mobility (CTM); CTM Access Profile (CAP); Profile Test Specification (PTS); Part 3: Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)33.070.30'(&7Digital Enhanced Cordless Telecommunications (DECT)ICS:Ta slovenski standard je istoveten z:EN 301 371-3 Version 0.0.3SIST EN 301 371-3:2001en01-februar-2001SIST EN 301 371-3:2001SLOVENSKI
STANDARD



SIST EN 301 371-3:2001



ETSI EN 301 371-3 V0.0.3 (1999-09)European Standard (Telecommunications series)Digital Enhanced Cordless Telecommunications (DECT);Cordless Terminal Mobility (CTM);CTM Access Profile (CAP);Profile Test Specification (PTS);Part 3: Profile Specific Test Specification (PSTS) -Fixed radio Termination (FT)SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)2ReferenceDEN/DECT-040120-3 (cp0r0020.PDF)KeywordsCAP, CTM, DECT, FT, testingETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)3ContentsIntellectual Property Rights.5Foreword.51Scope.62References.63Definitions and abbreviations.83.1Definitions.83.2Abbreviations.84Relevant test cases list.94.1Network (NWK) layer.94.1.1Test suite structure (TSS).104.1.2Test case index.124.2Data Link Control (DLC) layer.134.3Medium Access Control (MAC) layer.134.3.1Test suite structure.134.3.2Test case index.144.4Physical (PH) layer.145Additional test cases list.145.1Test purposes.145.1.1NWK layer.145.1.2DLC layer.145.1.3MAC layer.145.1.4PH layer.145.2Test cases.145.2.1NWK layer.155.2.2DLC layer.155.2.3MAC layer.155.2.4PH layer.15Annex A (normative):Profile Implementation eXtra Information for Testing (IXIT)proforma.16A.1General.16A.2Profile IXIT Requirements List (XRL).16A.2.1NWK layer protocol.16A.2.2DLC layer protocol.16A.2.3MAC layer protocol.16A.2.4PH layer protocol.16A.3Profile specific IXIT.17A.3.1NWK layer.17A.3.2DLC layer.17A.3.3MAC layer.17A.3.4PH layer.17A.3.5Configuration constraints.17Annex B (normative):Profile Conformance Test Report (PCTR) proforma.18B.1Identification summary.18B.1.1Profile CTR.18B.1.2Implementation Under Test (IUT).18B.1.3Testing environment.19B.1.4Limits and reservations.19B.1.5Comments.19SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)4B.2IUT conformance status.19B.3Static conformance summary.20B.4Dynamic conformance summary.20B.5Static conformance review report.20B.6Test campaign report.21B.6.1NWK layer.21B.6.2DLC layer.21B.6.3MAC layer.21B.6.4PH layer.21B.7Observations.22Annex C (normative):System Conformance Test Report (SCTR) proforma.23C.1Identification summary.23C.1.1System Conformance Test Report (SCTR).23C.1.2Test laboratory.23C.1.3Client.24C.1.4System Under Test (SUT).24C.1.5Profile.24C.1.6Nature of conformance testing.25C.1.7Limits and reservations.25C.1.8Record of agreement.25C.1.9Comments.25C.2System report summary.26C.2.1Profile testing summary for CAP NWK layer FT.26C.2.2Profile testing summary for CAP DLC layer FT.26C.2.3Profile testing summary for CAP MAC layer FT.27C.2.4Profile testing summary for CAP PH layer FT.27Annex D (normative):System Conformance Statement (SCS) proforma.28D.1Identification summary.28D.1.1SCS identification.28D.1.2IUT identification.28D.1.3Client identification.29D.1.4Supplier identification.29D.1.5Manufacturer identification.30D.1.6Protocols identification.30D.1.7Profile identification.30D.2Miscellaneous system information.31D.2.1Configuration.31D.2.2Other information.31Bibliography.32History.33SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)5Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server(http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Project Digital Enhanced CordlessTelecommunications (DECT).The CTM Access Profile (CAP) Profile Test Specification (PTS) comprises three parts:Part 1:"Summary";Part 2:"Profile Specific Test Specification (PSTS) - Portable radio Termination (PT)";Part 3:"Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)".National transposition datesDate of adoption of this EN:27 August 1999Date of latest announcement of this EN (doa):30 November 1999Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 May 2000Date of withdrawal of any conflicting National Standard (dow):31 May 2000SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)61ScopeThe present document contains the test specification for Digital Enhanced Cordless Telecommunications (DECT) CTMAccess Profile (CAP) Fixed Part (FP) applications.The main objective of the CAP test specification is to provide approval tests giving a high probability of air interfaceinter-operability between different manufacturer's equipment in different environments (i.e. public, business andresidential).The ISO standard for the methodology of conformance testing ISO/IEC 9646 Parts 1 [24] to 7 [30] is used as the basisfor the test methodology, and as the basis for the test case specification. This is considered to be unsuitable for Physicallayer testing, and therefore a text description is used.The test cases listed in the present document have been derived from the DECT Common Interface (CI) Test CaseLibrary (TCL) [14] to [22]. In addition as far as the Physical layer is concerned EN 300 176 [10] applies. AdditionalCAP specific test cases are included where required. The Profile IXIT is based on the DECT CI PIXITs specified inEN 300 497 [14] to [22].2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]EN 301 371-1: "Digital Enhanced Cordless Telecommunications (DECT); Cordless TerminalMobility (CTM); CTM Access Profile (CAP); Profile Test Specification (PTS); Part 1: Summary".[2]Void.[3]EN 300 175-1: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 1: Overview".[4]EN 300 175-2: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 2: Physical Layer (PHL)".[5]EN 300 175-3: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 3: Medium Access Control (MAC) layer".[6]EN 300 175-4: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 4: Data Link Control (DLC) layer".[7]EN 300 175-5: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 5: Network (NWK) layer".[8]EN 300 175-6: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 6: Identities and addressing".[9]EN 300 175-7: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Part 7: Security features".SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)7[10]EN 300 176: "Digital Enhanced Cordless Telecommunications (DECT); Approval testspecification".[11]EN 300 444: "Digital Enhanced Cordless Telecommunications (DECT); Generic Access Profile(GAP)".[12]ETS 300 476 (all parts): "Digital Enhanced Cordless Telecommunications (DECT); CommonInterface (CI); Protocol Implementation Conformance Statement (PICS) proforma".[13]EN 300 494-3: "Digital Enhanced Cordless Telecommunications (DECT); Generic Access Profile(GAP); Part 3: Profile Specific Test Specification (PSTS) - Fixed radio Termination (FT)".[14]EN 300 497-1: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 1: Test Suite Structure (TSS) and Test Purposes (TP) for MediumAccess Control (MAC) layer".[15]EN 300 497-2: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 2: Abstract Test Suite (ATS) for Medium Access Control (MAC)layer - Portable radio Termination (PT)".[16]EN 300 497-3: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 3: Abstract Test Suite (ATS) for Medium Access Control (MAC)layer - Fixed radio Termination (FT)".[17]EN 300 497-4: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 4: Test Suite Structure (TSS) and Test Purposes (TP) - Data LinkControl (DLC) layer".[18]EN 300 497-5: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 5: Abstract Test Suite (ATS) - Data Link Control (DLC) layer".[19]EN 300 497-6: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 6: Test Suite Structure (TSS) and Test Purposes (TP) - Network(NWK) layer - Portable radio Termination (PT)".[20]EN 300 497-7: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 7: Abstract Test Suite (ATS) for Network (NWK) layer - Portableradio Termination (PT)".[21]EN 300 497-8: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 8: Test Suite Structure (TSS) and Test Purposes (TP) - Network(NWK) layer - Fixed radio Termination (FT)".[22]EN 300 497-9: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI);Test Case Library (TCL); Part 9: Abstract Test Suite (ATS) for Network (NWK) layer - Fixedradio Termination (FT)".[23]EN 300 824: "Digital Enhanced Cordless Telecommunications (DECT); Cordless TerminalMobility (CTM); CTM Access Profile (CAP)".[24]ISO/IEC 9646-1: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 1: General concepts".[25]ISO/IEC 9646-2: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 2: Abstract Test Suite Specification".[26]ISO/IEC 9646-3: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 3: The Tree and Tabular Combined Notation (TTCN)".[27]ISO/IEC 9646-4: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 4: Test realization".SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)8[28]ISO/IEC 9646-5: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 5: Requirements on test laboratories and clients for theConformance Assessment process".[29]ISO/IEC 9646-6: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 6: Protocol Profile Test Specification".[30]ISO/IEC 9646-7: "Information technology; Open Systems Interconnection; Conformance testingmethodology and framework; Part 7: Implementation Conformance statement".3Definitions and abbreviations3.1DefinitionsFor the purposes of the present document, the following terms and definitions apply:-terms defined in ISO/IEC 9646 Parts 1 to 7 [24] to [30];-definitions in EN 300 175 Parts 1 to 7 [3] to [9];-definitions in EN 300 444 [11];-definitions in EN 300 824 [23].3.2AbbreviationsFor the purposes of the present document, the following abbreviations apply:ATSAbstract Test SuiteCAPCTM Access ProfileCCCall ControlCICommon InterfaceCTMCordless Terminal MobilityDECTDigital Enhanced Cordless TelecommunicationsDLCData Link ControlFTFixed radio TerminationGAPGeneric Access ProfileICSImplementation Conformance StatementIUTImplementation Under TestIXITImplementation eXtra Information for TestingLCELink Control EntityLLMELower Layer Management EntityMACMedium Access ControlMMMobility ManagementNWKNetworkPHPhysicalPICSProtocol Implementation Conformance StatementPIXITProtocol Implementation eXtra Information for TestingPTPortable radio TerminationPSTSProfile Specific Test SpecificationPTSProfile Test SpecificationSUTSystem Under TestSIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)94Relevant test cases list4.1Network (NWK) layerThis subclause includes lists of the test groups and abstract test cases relevant for CAP Profile Test Specification (PTS)- NWK layer Fixed Termination (FT) derived from EN 300 497-9 [22]. In addition all the test groups and abstract testcases relevant for GAP PTS, contained in EN 300 494-3 [13] shall apply.NOTE:References when necessary shall be made based on the particular test case name unique through all testspecification EN 300 497 [14] to [22].SIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)104.1.1Test suite structure (TSS)Table 1Test Suite StructureSuite Name:nwk_ftStandards Ref:EN 300 824 [23]; EN 300 497-9 [22]Profile ICS Ref:DEN/DECT-040121 Profile IXIT Ref:EN 300 494-3 [13]Test Method:remoteComments:Test Group ReferenceTest Group ObjectiveFT/To check the behaviour of the NWK layer of the FT(IUT)FT/CC/To check the IUT CC-state machine behaviourFT/CC/IT/To check that the IUT CC-state machine provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/CC/CA/Limited testing that the observable capabilities of the CC entity of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/CC/BV/To test the CC entity of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/CC/BV/OC/To check the IUT's behaviours to set-up an outgoing callFT/CC/BV/IC/To check the IUT's behaviours to set-up an incoming callFT/CC/BV/CI/To check the IUT's behaviour in information transfer proceduresFT/CC/BV/CR/To check the IUT's behaviours to release an outgoing/incoming callFT/CC/BV/HP/To check the IUT's behaviour during external handover proceduresFT/CC/RSTo check the IUT's behaviour during call related supplementary service procedures.FT/CC/BO/To check the behaviour of the CC entity of the IUT in response to the messages thatare syntactically correct but not allowed to occur in some states of the CC proceduresFT/CC/BI/To check the behaviour of the CC entity of the IUT in response to invalid messagesFT/CC/TI/To verify that the IUT CC timers are with correct values and the IUT is reacting properlyto the expiry of a timerFT/MM/To check the behaviour of the Mobility Management entity of the IUTFT/MM/IT/To check that the MM entity of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/MM/CA/Limited testing that the observable capabilities of the MM entity of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/MM/BV/To test the MM entity of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/MM/BV/ID/To check the IUT's behaviour concerning identity proceduresFT/MM/BV/AU/To check the IUT's behaviour concerning the authentication proceduresFT/MM/BV/LO/To check the IUT's behaviour concerning the location proceduresFT/MM/BV/AR/To check the IUT's behaviour concerning the access rights proceduresFT/MM/BV/KA/To check the IUT's behaviour concerning the key allocation procedureFT/MM/BV/CH/To check the IUT's behaviour concerning the ciphering related proceduresFT/MM/BV/HP/To check the IUT's behaviour during external handover proceduresFT/MM/BO/To check the IUT behaviour in response to the messages that are syntactically correctbut not allowed to occur in some phase of the MM proceduresFT/MM/BI/To check the IUT in response to invalid MM messagesFT/MM/TI/To verify that the IUT MM timers are with correct values and the IUT is reacting properlyto the expiry of a timerFT/ME/To check the behaviour of the LLME of the IUTFT/ME/IT/To check that LLME of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/ME/CA/Limited testing that the observable capabilities of the LLME of the IUT are inaccordance with the static conformance requirements and the additional capabilitiesclaimed in the PROFILE ICS/PROFILE IXITFT/ME/BV/To test the LLME of the IUT in response to syntactically and contextual correctbehaviour of the test systemFT/LC/To check the behaviour of the LCE of the IUTSIST EN 301 371-3:2001



ETSIETSI EN 301 371-3 V0.0.3 (1999-09)11Test Suite StructureSuite Name:nwk_ftStandards Ref:EN 300 824 [23]; EN 300 497-9 [22]Profile ICS Ref:DEN/DECT-040121 Profile IXIT Ref:EN 300 494-3 [13]Test Method:remoteComments:Test Group ReferenceTest Group ObjectiveFT/LC/IT/To check that LCE of the IUT provides sufficient conformance for possibleinterconnection without trying to perform thorough testingFT/LC/CA/Limited testing that the observable capabilities of the LCE of the IUT are in accordancewith the static conformance requirements and the additional capabilities claimed in thePROFILE ICS/PROFILE IXITFT/LC/BV/To test the LCE of the IUT in response to syntactically and contextual correct behaviourof the test systemFT/LC/BV/LE/To check the IUT's behaviour c
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.