Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 3-1: Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions

REN/TM-01042-3-1

Prenos in multipleksiranje (TM) – Generične zahteve za prenosno funkcionalnost opreme – 3-1. del: Funkcije plasti regeneratorskega in multipleksnega odseka za sinhroni prenosni modul-N (STM-N)

General Information

Status
Published
Publication Date
21-Oct-2001
Current Stage
12 - Completion
Due Date
29-Oct-2001
Completion Date
22-Oct-2001
Standard
EN 300 417-3-1 V1.2.1:2003
English language
249 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2003
3UHQRVLQPXOWLSOHNVLUDQMH 70 ±*HQHULþQH]DKWHYH]DSUHQRVQRIXQNFLRQDOQRVW
RSUHPH±GHO)XQNFLMHSODVWLUHJHQHUDWRUVNHJDLQPXOWLSOHNVQHJDRGVHND]D
VLQKURQLSUHQRVQLPRGXO1 6701
Transmission and Multiplexing (TM); Generic requirements of transport functionality of
equipment; Part 3-1: Synchronous Transport Module-N (STM-N) regenerator and
multiplex section layer functions
Ta slovenski standard je istoveten z: EN 300 417-3-1 Version 1.2.1
ICS:
33.040.20 Prenosni sistem Transmission systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

European Standard (Telecommunications series)

Transmission and Multiplexing (TM);
Generic requirements of transport functionality of equipment;
Part 3-1: Synchronous Transport Module-N (STM-N)
regenerator and multiplex section layer functions

2 ETSI EN 300 417-3-1 V1.2.1 (2001-10)

Reference
REN/TM-01042-3-1
Keywords
transmission, SDH, interface, architecture
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2001.
All rights reserved.
ETSI
3 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
Contents
Intellectual Property Rights.9
Foreword.9
1 Scope.11
2 References.11
3 Definitions, abbreviations and symbols .11
3.1 Definitions.11
3.2 Abbreviations.11
3.3 Symbols and Diagrammatic Conventions .14
3.4 Introduction.14
4 STM-1 Regenerator Section Layer Functions.14
4.1 STM-1 Regenerator Section Connection functions.15
4.2 STM-1 Regenerator Section Trail Termination functions.16
4.2.1 STM-1 Regenerator Section Trail Termination Source RS1_TT_So .16
4.2.2 STM-1 Regenerator Section Trail Termination Sink RS1_TT_Sk.17
4.3 STM-1 Regenerator Section Adaptation functions.19
4.3.1 STM-1 Regenerator Section to Multiplex Section Adaptation Source RS1/MS1_A_So .19
4.3.2 STM-1 Regenerator Section to Multiplex Section Adaptation Sink RS1/MS1_A_Sk .20
4.3.3 STM-1 Regenerator Section to DCC Adaptation Source RS1/DCC_A_So .21
4.3.4 STM-1 Regenerator Section to DCC Adaptation Sink RS1/DCC_A_Sk .22
4.3.5 STM-1 Regenerator Section to P0s Adaptation Source RS1/P0s_A_So/N .22
4.3.6 STM-1 Regenerator Section to P0s Adaptation Sink RS1/P0s_A_Sk/N .23
4.3.7 STM-1 Regenerator Section toV0x Adaptation Source RS1/V0x_A_So .24
4.3.8 STM-1 Regenerator Section to V0x Adaptation Sink RS1/V0x_A_Sk.25
5 STM-1 Multiplex Section Layer Functions.26
5.1 STM-1 Multiplex Section Connection functions.28
5.2 STM-1 Multiplex Section Trail Termination functions.28
5.2.1 STM-1 Multiplex Section Trail Termination Source MS1_TT_So .28
5.2.2 STM-1 Multiplex Section Trail Termination Sink MS1_TT_Sk.29
5.3 STM-1 Multiplex Section Adaptation functions .32
5.3.1 STM-1 Multiplex Section to S4 Layer Adaptation Source MS1/S4_A_So .32
5.3.2 STM-1 Multiplex Section to S4 Layer Adaptation Sink MS1/S4_A_Sk.34
5.3.3 STM-1 Multiplex Section to DCC Adaptation Source MS1/DCC_A_So .35
5.3.4 STM-1 Multiplex Section to DCC Adaptation Sink MS1/DCC_A_Sk.36
5.3.5 STM-1 Multiplex Section to P0s Adaptation Source MS1/P0s_A_So .36
5.3.6 STM-1 Multiplex Section to P0s Adaptation Sink MS1/P0s_A_Sk.37
5.3.7 STM-1 Multiplex Section to Synchronization Distribution Adaptation Source MS1/SD_A_So .38
5.3.8 STM-1 Multiplex Section to Synchronization Distribution Adaptation Sink MS1/SD_A_Sk .38
5.3.9 STM-1 Multiplex Section Layer Clock Adaptation Source MS1-LC_A_So.38
5.4 STM-1 Multiplex Section Layer Monitoring Functions.38
5.5 STM-1 Multiplex Section Linear Trail Protection Functions.39
5.5.1 STM-1 Multiplex Section Linear Trail Protection Connection Functions.39
5.5.1.1 STM-1 Multiplex Section 1+1 Linear Trail Protection Connection MS1P1+1_C.39
5.5.1.2 STM-1 Multiplex Section 1:n Linear Trail Protection Connection MS1P1:n_C .40
5.5.2 STM-1 Multiplex Section Linear Trail Protection Trail Termination Functions.42
5.5.2.1 Multiplex Section Protection Trail Termination Source MS1P_TT_So .42
5.5.2.2 Multiplex Section Protection Trail Termination Sink MS1P_TT_Sk .43
5.5.3 STM-1 Multiplex Section Linear Trail Protection Adaptation Functions.44
5.5.3.1 STM-1 Multiplex Section to STM-1 Multiplex Section Protection Layer Adaptation Source
MS1/MS1P_A_So.44
5.5.3.2 STM-1 Multiplex Section to STM-1 Multiplex Section Protection Layer Adaptation Sink
MS1/MS1P_A_Sk.45
6 STM-4 Regenerator Section Layer Functions.46
6.1 STM-4 Regenerator Section Connection functions.47
ETSI
4 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
6.2 STM-4 Regenerator Section Trail Termination functions.47
6.2.1 STM-4 Regenerator Section Trail Termination Source RS4_TT_So .47
6.2.2 STM-4 Regenerator Section Trail Termination Sink RS4_TT_Sk.49
6.3 STM-4 Regenerator Section Adaptation functions.51
6.3.1 STM-4 Regenerator Section to Multiplex Section Adaptation Source RS4/MS4_A_So .51
6.3.2 STM-4 Regenerator Section to Multiplex Section Adaptation Sink RS4/MS4_A_Sk .52
6.3.3 STM-4 Regenerator Section to DCC Adaptation Source RS4/DCC_A_So .53
6.3.4 STM-4 Regenerator Section to DCC Adaptation Sink RS4/DCC_A_Sk .53
6.3.5 STM-4 Regenerator Section to P0s Adaptation Source RS4/P0s_A_So/N .54
6.3.6 STM-4 Regenerator Section to P0s Adaptation Sink RS4/P0s_A_Sk/N .55
6.3.7 STM-4 Regenerator Section to V0x Adaptation Source RS4/V0x_A_So .56
6.3.8 STM-4 Regenerator Section to V0x Adaptation Sink RS4/V0x_A_Sk.57
7 STM-4 Multiplex Section Layer Functions.58
7.1 STM-4 Multiplex Section Connection functions.60
7.2 STM-4 Multiplex Section Trail Termination functions.61
7.2.1 STM-4 Multiplex Section Trail Termination Source MS4_TT_So .61
7.2.2 STM-4 Multiplex Section Trail Termination Sink MS4_TT_Sk.62
7.3 STM-4 Multiplex Section Adaptation functions .64
7.3.1 STM-4 Multiplex Section to S4 Layer Adaptation Source MS4/S4_A_So/(B,0).64
7.3.2 STM-4 Multiplex Section to S4 Layer Adaptation Sink MS4/S4_A_Sk/(B,0) .67
7.3.3 STM-4 Multiplex Section to S4-4c Layer Adaptation Source MS4/S4-4c_A_So.68
7.3.4 STM-4 Multiplex Section to S4-4c Layer Adaptation Sink MS4/S4-4c_A_Sk.70
7.3.5 STM-4 Multiplex Section to DCC Adaptation Source MS4/DCC_A_So .72
7.3.6 STM-4 Multiplex Section to DCC Adaptation Sink MS4/DCC_A_Sk.72
7.3.7 STM-4 Multiplex Section to P0s Adaptation Source MS4/P0s_A_So .73
7.3.8 STM-4 Multiplex Section to P0s Adaptation Sink MS4/P0s_A_Sk.74
7.3.9 STM-4 Multiplex Section to Synchronization Distribution Adaptation Source MS4/SD_A_So .75
7.3.10 STM-4 Multiplex Section to Synchronization Distribution Adaptation Sink MS4/SD_A_Sk .75
7.3.11 STM-4 Multiplex Section Layer Clock Adaptation Source MS4-LC_A_So.75
7.4 STM-4 Multiplex Section Layer Monitoring Functions.75
7.5 STM-4 Multiplex Section Linear Trail Protection Functions.75
7.5.1 STM-4 Multiplex Section Linear Trail Protection Connection Functions.75
7.5.1.1 STM-4 Multiplex Section 1+1 Linear Trail Protection Connection MS4P1+1_C.75
7.5.1.2 STM-4 Multiplex Section 1:n Linear Trail Protection Connection MS4P1:n_C .77
7.5.2 STM-4 Multiplex Section Linear Trail Protection Trail Termination Functions.78
7.5.2.1 Multiplex Section Protection Trail Termination Source MS4P_TT_So .78
7.5.2.2 Multiplex Section Protection Trail Termination Sink MS4P_TT_Sk .79
7.5.3 STM-4 Multiplex Section Linear Trail Protection Adaptation Functions.80
7.5.3.1 STM-4 Multiplex Section to STM-4 Multiplex Section Protection Layer Adaptation Source
MS4/MS4P_A_So.80
7.5.3.2 STM-4 Multiplex Section to STM-4 Multiplex Section Protection Layer Adaptation Sink
MS4/MS4P_A_Sk.81
8 STM-16 Regenerator Section Layer Functions.82
8.1 STM-16 Regenerator Section Connection functions.83
8.2 STM-16 Regenerator Section Trail Termination functions.83
8.2.1 STM-16 Regenerator Section Trail Termination Source RS16_TT_So .83
8.2.2 STM-16 Regenerator Section Trail Termination Sink RS16_TT_Sk .85
8.3 STM-16 Regenerator Section Adaptation functions.87
8.3.1 STM-16 Regenerator Section to Multiplex Section Adaptation Source RS16/MS16_A_So.87
8.3.2 STM-16 Regenerator Section to Multiplex Section Adaptation Sink RS16/MS16_A_Sk .88
8.3.3 STM-16 Regenerator Section to DCC Adaptation Source RS16/DCC_A_So .88
8.3.4 STM-16 Regenerator Section to DCC Adaptation Sink RS16/DCC_A_Sk .89
8.3.5 STM-16 Regenerator Section to P0s Adaptation Source RS16/P0s_A_So/N .90
8.3.6 STM-16 Regenerator Section to P0s Adaptation Sink RS16/P0s_A_Sk/N .91
8.3.7 STM-16 Regenerator Section to V0x Adaptation Source RS16/V0x_A_So .92
8.3.8 STM-16 Regenerator Section to V0x Adaptation Sink RS16/V0x_A_Sk.92
9 STM-16 Multiplex Section Layer Functions.93
9.1 STM-16 Multiplex Section Connection functions.98
9.2 STM-16 Multiplex Section Trail Termination functions.98
9.2.1 STM-16 Multiplex Section Trail Termination Source MS16_TT_So .98
ETSI
5 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
9.2.2 STM-16 Multiplex Section Trail Termination Sink MS16_TT_Sk.99
9.3 STM-16 Multiplex Section Adaptation functions .101
9.3.1 STM-16 Multiplex Section to S4 Layer Adaptation Source MS16/S4_A_So/(C,B,0).101
9.3.2 STM-16 Multiplex Section to S4 Layer Adaptation Sink MS16/S4_A_Sk/(C,B,0).103
9.3.3 STM-16 Multiplex Section to S4-4c Layer Adaptation Source MS16/S4-4c_A_So/(C,0,0).104
9.3.4 STM-16 Multiplex Section to S4-4c Layer Adaptation Sink MS16/S4-4c_A_Sk/(C,0,0) .107
9.3.5 STM-16 Multiplex Section to S4-16c Layer Adaptation Source MS16/S4-16c_A_So.108
9.3.6 STM-16 Multiplex Section to S4-16c Layer Adaptation Sink MS16/S4-16c_A_Sk.110
9.3.7 STM-16 Multiplex Section to DCC Adaptation Source MS16/DCC_A_So .112
9.3.8 STM-16 Multiplex Section to DCC Adaptation Sink MS16/DCC_A_Sk .112
9.3.9 STM-16 Multiplex Section to P0s Adaptation Source MS16/P0s_A_So .113
9.3.10 STM-16 Multiplex Section to P0s Adaptation Sink MS16/P0s_A_Sk.114
9.3.11 STM-16 Multiplex Section to Synchronization Distribution Adaptation Source MS16/SD_A_So .115
9.3.12 STM-16 Multiplex Section to Synchronization Distribution Adaptation Sink MS16/SD_A_Sk .115
9.3.13 STM-16 Multiplex Section Layer Clock Adaptation Source MS16-LC_A_So.115
9.4 STM-16 Multiplex Section Layer Monitoring Functions.115
9.5 STM-16 Multiplex Section Linear Trail Protection Functions.115
9.5.1 STM-16 Multiplex Section Linear Trail Protection Connection Functions.115
9.5.1.1 STM-16 Multiplex Section 1+1 Linear Trail Protection Connection MS16P1+1_C.115
9.5.1.2 STM-16 Multiplex Section 1:n Linear Trail Protection Connection MS16P1:n_C .117
9.5.2 STM-16 Multiplex Section Linear Trail Protection Trail Termination Functions.119
9.5.2.1 Multiplex Section Protection Trail Termination Source MS16P_TT_So .119
9.5.2.2 Multiplex Section Protection Trail Termination Sink MS16P_TT_Sk .120
9.5.3 STM-16 Multiplex Section Linear Trail Protection Adaptation Functions.121
9.5.3.1 STM-16 Multiplex Section to STM-16 Multiplex Section Protection Layer Adaptation Source
MS16/MS16P_A_So.121
9.5.3.2 STM-16 Multiplex Section to STM-16 Multiplex Section Protection Layer Adaptation Sink
MS16/MS16P_A_Sk.122
9.6 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Functions.122
9.6.1 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Connection MS16P2fsh_C .123
9.6.2 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination Functions.127
9.6.2.1 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination Source
MS16P2fsh_TT_So.127
9.6.2.2 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Trail Termination Sink
MS16P2fsh_TT_Sk.128
9.6.3 STM-16 Multiplex Section 2 Fibre Shared Protection Ring Adaptation Functions.129
9.6.3.1 STM-16 Multiplex Section to STM-16 Multiplex Section 2 Fibre Shared Protection Ring
Adaptation Source MS16/MS16P2fsh_A_So .129
9.6.3.2 STM-16 Multiplex Section to STM-16 Multiplex Section 2 Fibre Shared Protection Ring
Adaptation Sink MS16/MS16P2fsh_A_Sk .130
10 STM-64 Regenerator Section layer functions .131
10.1 STM-64 Regenerator Section Connection functions.132
10.2 STM-64 Regenerator Section Trail Termination functions.132
10.2.1 STM-64 Regenerator Section Trail Termination Source RS64_TT_So .132
10.2.2 STM-64 Regenerator Section Trail Termination Sink RS64_TT_Sk.134
10.3 STM-64 Regenerator Section Adaptation functions.136
10.3.1 STM-64 Regenerator Section to Multiplex Section Adaptation Source RS64/MS64_A_So.136
10.3.2 STM-64 Regenerator Section to Multiplex Section Adaptation Sink RS64/MS64_A_Sk .137
10.3.3 STM-64 Regenerator Section to DCC Adaptation Source RS64/DCC_A_So .137
10.3.4 STM-64 Regenerator Section to DCC Adaptation Sink RS64/DCC_A_Sk .138
10.3.5 STM-64 Regenerator Section to P0s Adaptation Source RS64/P0s_A_So/N .139
10.3.6 STM-64 Regenerator Section to P0s Adaptation Sink RS64/P0s_A_Sk/N .140
10.3.7 STM-64 Regenerator Section to V0x Adaptation Source RS64/V0x_A_So .141
10.3.8 STM-64 Regenerator Section to V0x Adaptation Sink RS64/V0x_A_Sk.141
10.3.9 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation supporting FEC.142
10.3.9.1 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC transparent .142
10.3.9.1.1 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC transparent
Source Function RS64/MSF64_A _So.142
10.3.9.1.2 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC transparent Sink
Function RS64/MSF64_A _Sk.143
10.3.9.2 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC generation .144
ETSI
6 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
10.3.9.2.1 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC generation
Source Function RS64/MS64-fec_A _So.144
10.3.9.2.2 STM-64 Regenerator Section to STM-64 Multiplex Section Adaptation FEC generation Sink
Function RS64/MS64-fec_A _Sk.146
11 STM-64 Multiplex Section layer functions.148
11.1 STM-64 Multiplex Section Connection functions.151
11.2 STM-64 Multiplex Section Trail Termination functions.151
11.2.1 STM-64 Multiplex Section Trail Termination Source MS64_TT_So .151
11.2.2 STM-64 Multiplex Section Trail Termination Sink MS64_TT_Sk.152
11.3 STM-64 Multiplex Section Adaptation functions .155
11.3.1 STM-64 Multiplex Section to S4 Layer Adaptation Source MS64/S4_A_So/(D,C,B,0) .155
11.3.2 STM-64 Multiplex Section to S4 Layer Adaptation Sink MS64/S4_A_Sk/(D,C,B,0).157
11.3.3 STM-64 Multiplex Section to S4-4c Layer Adaptation Source MS64/S4-4c_A_So/(D,C,0,0).158
11.3.4 STM-64 Multiplex Section to S4-4c Layer Adaptation Sink MS64/S4-4c_A_Sk/(D,C,0,0) .161
11.3.5 STM-64 Multiplex Section to S4-16c Layer Adaptation Source MS64/S4-16c_A_So/(D,0,0,0) .162
11.3.6 STM-64 Multiplex Section to S4-16c Layer Adaptation Sink MS64/S4-16c_A_Sk/(D,0,0,0) .165
11.3.7 STM-64 Multiplex Section to S4-64c Layer Adaptation Source MS64/S4-64c_A_So.166
11.3.8 STM-64 Multiplex Section to S4-64c Layer Adaptation Sink MS64/S4-64c_A_Sk.168
11.3.9 STM-64 Multiplex Section to DCC Adaptation Source MS64/DCC_A_So .170
11.3.10 STM-64 Multiplex Section to DCC Adaptation Sink MS64/DCC_A_Sk .170
11.3.11 STM-64 Multiplex Section to P0s Adaptation Source MS64/P0s_A_So .171
11.3.12 STM-64 Multiplex Section to P0s Adaptation Sink MS64/P0s_A_Sk.172
11.3.13 STM-64 Multiplex Section to Synchronization Distribution Adaptation Source MS64/SD_A_So .173
11.3.14 STM-64 Multiplex Section to Synchronization Distribution Adaptation Sink MS64/SD_A_Sk .173
11.3.15 STM-64 Multiplex Section Layer Clock Adaptation Source MS64-LC_A_So.173
11.4 STM-64 Multiplex Section Layer Monitoring Functions.173
11.5 STM-64 Multiplex Section Linear Trail Protection Functions.173
11.5.1 STM-64 Multiplex Section Linear Trail Protection Connection Functions.173
11.5.1.1 STM-64 Multiplex Section 1+1 Linear Trail Protection Connection MS64P1+1_C.173
11.5.1.2 STM-64 Multiplex Section 1:n Linear Trail Protection Connection MS64P1:n_C .175
11.5.2 STM-64 Multiplex Section Linear Trail Protection Trail Termination Functions.176
11.5.2.1 Multiplex Section Protection Trail Termination Source MS64P_TT_So .176
11.5.2.2 Multiplex Section Protection Trail Termination Sink MS64P_TT_Sk .177
11.5.3 STM-64 Multiplex Section Linear Trail Protection Adaptation Functions.178
11.5.3.1 STM-64 Multiplex Section to STM-64 Multiplex Section Protection Layer Adaptation Source
MS64/MS64P_A_So.178
11.5.3.2 STM-64 Multiplex Section to STM-64 Multiplex Section Protection Layer Adaptation Sink
MS64/MS64P_A_Sk.179
11.6 STM-64 Multiplex Section 2 Fibre Shared Protection Ring Functions.179
12 STM-256 Regenerator Section layer functions .180
12.1 STM-256 Regenerator Section Connection functions.181
12.2 STM-256 Regenerator Section Trail Termination functions.181
12.2.1 STM-256 Regenerator Section Trail Termination Source RS256_TT_So .181
12.2.2 STM-256 Regenerator Section Trail Termination Sink RS256_TT_Sk.183
12.3 STM-256 Regenerator Section Adaptation functions.185
12.3.1 STM-256 Regenerator Section to Multiplex Section Adaptation Source RS256/MS256_A_So.185
12.3.2 STM-256 Regenerator Section to Multiplex Section Adaptation Sink RS256/MS256_A_Sk .186
12.3.3 STM-256 Regenerator Section to DCC Adaptation Source RS256/DCC_A_So .187
12.3.4 STM-256 Regenerator Section to DCC Adaptation Sink RS256/DCC_A_Sk .187
12.3.5 STM-256 Regenerator Section to P0s Adaptation Source RS256/P0s_A_So/N .188
12.3.6 STM-256 Regenerator Section to P0s Adaptation Sink RS256/P0s_A_Sk/N .189
12.3.7 STM-256 Regenerator Section to V0x Adaptation Source RS256/V0x_A_So .190
12.3.8 STM-256 Regenerator Section to V0x Adaptation Sink RS256/V0x_A_Sk.191
12.3.9 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation supporting FEC.192
12.3.9.1 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC transparent .192
12.3.9.1.1 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC transparent
Source Function RS256/MSF256_A _So.192
12.3.9.1.2 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC transparent
Sink Function RS256/MSF256_A _Sk.193
12.3.9.2 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC generation .194
ETSI
7 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
12.3.9.2.1 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC generation
Source Function RS256/MS256-fec_A _So .194
12.3.9.2.2 STM-256 Regenerator Section to STM-256 Multiplex Section Adaptation FEC generation
Sink Function RS256/MS256-fec_A _Sk.196
13 STM-256 Multiplex Section layer functions.198
13.1 STM-256 Multiplex Section Connection functions.201
13.2 STM-256 Multiplex Section Trail Termination functions.201
13.2.1 STM-256 Multiplex Section Trail Termination Source MS256_TT_So .201
13.2.2 STM-256 Multiplex Section Trail Termination Sink MS256_TT_Sk.202
13.3 STM-256 Multiplex Section Adaptation functions .205
13.3.1 STM-256 Multiplex Section to S4 Layer Adaptation Source MS256/S4_A_So/(E,D,C,B,0).205
13.3.2 STM-256 Multiplex Section to S4 Layer Adaptation Sink MS256/S4_A_Sk/(E,D,C,B,0).207
13.3.3 STM-256 Multiplex Section to S4-4c Layer Adaptation Source MS256/S4-4c_A_So/(E,D,C,0,0) .208
13.3.4 STM-256 Multiplex Section to S4-4c Layer Adaptation Sink MS256/S4-4c_A_Sk/(E,D,C,0,0).211
13.3.5 STM-256 Multiplex Section to S4-16c Layer Adaptation Source MS256/S4-16c_A_So/(E,D,0,0,0).212
13.3.6 STM-256 Multiplex Section to S4-16c Layer Adaptation Sink MS256/S4-16c_A_Sk/(E,D,0,0,0).215
13.3.7 STM-256 Multiplex Section to S4-64c Layer Adaptation Source MS256/S4-64c_A_So/(E,0,0,0,0).216
13.3.8 STM-256 Multiplex Section to S4-64c Layer Adaptation Sink MS256/S4-64c_A_Sk/(E,0,0,0,0).219
13.3.9 STM-256 Multiplex Section to S4-256c Layer Adaptation Source MS256/S4-256c_A_So.220
13.3.10 STM-256 Multiplex Section to S4-256c Layer Adaptation Sink MS256/S4-256c_A_Sk.222
13.3.11 STM-256 Multiplex Section to DCC Adaptation Source MS256/DCC_A_So .224
13.3.12 STM-256 Multiplex Section to DCC Adaptation Sink MS256/DCC_A_Sk .224
13.3.13 STM-256 Multiplex Section to Extended DCC Adaptation Source MS256/XDCC_A_So.225
13.3.14 STM-256 Multiplex Section to Extended DCC Adaptation Sink MS256/XDCC_A_Sk .226
13.3.15 STM-256 Multiplex Section to P0s Adaptation Source MS256/P0s_A_So .227
13.3.16 STM-256 Multiplex Section to P0s Adaptation Sink MS256/P0s_A_Sk.228
13.3.17 STM-256 Multiplex Section to Synchronization Distribution Adaptation Source MS256/SD_A_So .228
13.3.18 STM-256 Multiplex Section to Synchronization Distribution Adaptation Sink MS256/SD_A_Sk .229
13.3.19 STM-256 Multiplex Section Layer Clock Adaptation Source MS256-LC_A_So.229
13.4 STM-256 Multiplex Section Layer Monitoring Functions.229
13.5 STM-256 Multiplex Section Linear Trail Protection Functions.229
13.5.1 STM-256 Multiplex Section Linear Trail Protection Connection Functions.229
13.5.1.1 STM-256 Multiplex Section 1+1 Linear Trail Protection Connection MS256P1+1_C.229
13.5.1.2 STM-256 Multiplex Section 1:n Linear Trail Protection Connection MS256P1:n_C .231
13.5.2 STM-256 Multiplex Section Linear Trail Protection Trail Termination Functions.233
13.5.2.1 Multiplex Section Protection Trail Termination Source MS256P_TT_So .233
13.5.2.2 Multiplex Section Protection Trail Termination Sink MS256P_TT_Sk .234
13.5.3 STM-256 Multiplex Section Linear Trail Protection Adaptation Functions.235
13.5.3.1 STM-256 Multiplex Section to STM-256 Multiplex Section Protection Layer Adaptation Source
MS256/MS256P_A_So.235
13.5.3.2 STM-256 Multiplex Section to STM-256 Multiplex Section Protection Layer Adaptation Sink
MS256/MS256P_A_Sk.236
13.6 STM-256 Multiplex Section 2 Fibre Shared Protection Ring Functions.236
Annex A (normative): Generic specification of linear protection switching operation .237
Annex B (informative): STM-16 regenerator functional model (example).238
Annex C (informative): Void .239
Annex D (informative): MS protection examples .240
Annex E (informative): FEC for STM-16 Regenerator Section Layer .242
E.1 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation supporting FEC.242
E.1.1 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC transparent .242
E.1.1.1 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC transparent Source
Function RS16/MSF16_A _So .242
E.1.1.2 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC transparent Sink
Function RS16/MSF16_A _Sk .243
E.1.2 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC generation .244
ETSI
8 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
E.1.2.1 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC generation Source
Function RS16/MS16-fec_A _So .244
E.1.2.2 STM-16 Regenerator Section to STM-16 Multiplex Section Adaptation FEC generation Sink
Function RS16/MS16-fec_A _Sk .246
Annex F (informative): Bibliography.248
History .249

ETSI
9 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://www.etsi.org/legal/home.htm).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Transmission
and Multiplexing (TM).
The present document is one of a family of documents that has been produced in order to provide inter-vendor and
inter-operator compatibility of Synchronous Digital Hierarchy (SDH) equipment.
The present document is part 3, sub-part 1 of a multi-part deliverable covering the Generic requirements of transport
functionality of equipment, as identified below:
Part 1-1: "Generic processes and performance";
Part 1-2: "General information about Implementation Conformance Statement (ICS) proforma";
Part 2-1: "Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section
layer functions";
Part 2-2: "Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section
layer functions; Implementation Conformance Statement (ICS) proforma specification";
Part 3-1: "Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions";
Part 3-2: "Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions;
Implementation Conformance Statement (ICS) proforma specification";
Part 4-1: "Synchronous Digital Hierarchy (SDH) path layer functions";
Part 4-2: "Synchronous Digital Hierarchy (SDH) path layer functions; Implementation Conformance Statement
(ICS) proforma specification";
Part 5-1: "Plesiochronous Digital Hierarchy (PDH) path layer functions";
Part 5-2: "Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement
(ICS) proforma specification";
Part 6-1: "Synchronization layer functions";
Part 6-2: "Synchronization layer functions; Implementation Conformance Statement (ICS) proforma specification";
Part 7-1: "Equipment management and auxiliary layer functions";
Part 9-1: "Synchronous Digital Hierarchy (SDH) concatenated path layer functions; Requirements".
Parts 2 to 7 specify the layers and their atomic functions.
Parts 2 to 7 specify the layers and their atomic functions.
NOTE: The SDH radio equipment functional blocks are addressed by ETSI WG TM4.
ETSI
10 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
Various of the above parts have previously been published as parts of ETS 300 417.
They have been converted to parts of EN 300 417 without technical changes, but some editorial changes have been
necessary (e.g. references). In particular:
- Parts 2-1 and 3-2 have been modified to take account of editorial errors present in edition 1.
- Part 1-1 has had its title change of to align with other parts published at a later date.
Also note that in the meantime parts 8-1, 8-2 and 8-3 have been stopped.

National transposition dates
Date of adoption of this EN: 12 October 2001
Date of latest announcement of this EN (doa): 31 January 2002
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 July 2002
Date of withdrawal of any conflicting National Standard (dow): 31 July 2002

ETSI
11 ETSI EN 300 417-3-1 V1.2.1 (2001-10)
1 Scope
The present document specifies a library of basic building blocks and a set of rules by which they are combined in order
to describe transport functionality of equipment. The library comprises the functional building blocks needed to
completely specify the generic functional structure of the European Transmission Hierarchies. Equipment which is
compliant with the present doc
...