HD 22.10 S1:1994
(Main)Rubber insulated cables of rated voltages up to and including 450/750 V - Part 10: EPR insulated and polyurethane sheathed flexible cable
- Abstract
This Part 10 of the HD details the particular requirements for ethylene-propylene rubber insulated, and thermoplastic polyurethane sheathed cable for a maximum conductor temperature of 90øC and lowest handling temperature of -40øC. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requirements of this Part. NOTE 1 : The sheath specified in this Part of HD 22 is unvulcanised. The requirements and special additional test methods are therefore included as Annex A to this Part. NOTE 2: The overall dimensions of the cables in this Part of HD 22 have been calculated in accordance with EN 60719.
- Status
- Withdrawn
- Publication Date
- 30-Nov-2008
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- TC 20 - Electric cables
- Parallel Committee
- TC 20 - Electric cables
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Dec-2008
- Due Date
- 01-Dec-2008
- Completion Date
- 01-Dec-2008
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 28-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
HD 22.10 S1:1994 is a standardization document published by CLC. Its full title is "Rubber insulated cables of rated voltages up to and including 450/750 V - Part 10: EPR insulated and polyurethane sheathed flexible cable". This standard covers: This Part 10 of the HD details the particular requirements for ethylene-propylene rubber insulated, and thermoplastic polyurethane sheathed cable for a maximum conductor temperature of 90øC and lowest handling temperature of -40øC. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requirements of this Part. NOTE 1 : The sheath specified in this Part of HD 22 is unvulcanised. The requirements and special additional test methods are therefore included as Annex A to this Part. NOTE 2: The overall dimensions of the cables in this Part of HD 22 have been calculated in accordance with EN 60719.
This Part 10 of the HD details the particular requirements for ethylene-propylene rubber insulated, and thermoplastic polyurethane sheathed cable for a maximum conductor temperature of 90øC and lowest handling temperature of -40øC. Each cable shall comply with the appropriate requirements given in Part 1 of this HD and the particular requirements of this Part. NOTE 1 : The sheath specified in this Part of HD 22 is unvulcanised. The requirements and special additional test methods are therefore included as Annex A to this Part. NOTE 2: The overall dimensions of the cables in this Part of HD 22 have been calculated in accordance with EN 60719.
HD 22.10 S1:1994 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
HD 22.10 S1:1994 has the following relationships with other standards: It is inter standard links to HD 22.10 S2:2007, HD 22.10 S1:1994/A1:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
HD 22.10 S1:1994 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
HD 22.10 S1:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-1998
Rubber insulated cables of rated voltages up to and including 450/750 V - Part 10:
EPR insulated and polyurethane sheathed flexible cable
Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 10: EPR
insulated and polyurethane sheathed flexible cable
Gummi-isolierte Leitungen mit Nennspannungen bis 450/750 V -- Teil 10: EPR-isolierte
flexible Starkstromleitungen mit Polyurethanmantel
Conducteurs et câbles isolés au caoutchouc de tension assignée au plus égale à
450/750 V -- Partie 10: Câbles souples à isolation EPR et gaine polyuréthane
Ta slovenski standard je istoveten z: HD 22.10 S1:1994
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST
...