EN 61753-111-9:2010
(Main)Fibre optic interconnecting devices and passive components - Performance standard - Part 111-9: Sealed closures for category S - Subterranean
Fibre optic interconnecting devices and passive components - Performance standard - Part 111-9: Sealed closures for category S - Subterranean
IEC 61753-111-9:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category S - subterranean, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil 111-9: Druckdichte Muffen für die Kategorie S - unterirdische Verlegung
Dispositifs d'interconnexion et composants passifs à fibres optiques - Norme de qualité de fonctionnement - Partie 111-9: Boîtiers scellés pour catégorie S - Souterrain
La CEI 61753-111-9:2009 contient les sévérités et les exigences minimales d'essai et de mesure auxquelles un boîtier à fibres optiques scellé doit satisfaire afin d'être classé comme conforme aux exigences de la norme CEI pour la catégorie S - souterrain, telle qu'elle est définie à l'Annexe A de la CEI 61753-1. Les boîtiers à ventilation libre ne sont pas couverts par la présente norme.
Optični spojni elementi in pasivne komponente - Izvedbeni standard - 111-9. del: Zatesnjene spojnice za kategorijo S (Subterranean) - Podzemna uporaba (IEC 61753-111-9:2009)
Ta del IEC 61753 vsebuje minimalne zahteve za preskus in merjenje ter natančnost, ki jih mora izpolnjevati zatesnjena optična spojnica, da zadošča standardu IEC za kategorijo S (Subterranean) – Podzemna uporaba, kot je opredeljeno v Dodatku A IEC 61753-1. Ta standard ne zajema spojnic z zračenjem.
General Information
- Status
- Withdrawn
- Publication Date
- 18-Feb-2010
- Withdrawal Date
- 31-Jan-2013
- Drafting Committee
- IEC/SC 86B - IEC_SC_86B
- Parallel Committee
- IEC/SC 86B - IEC_SC_86B
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 19-Oct-2024
- Completion Date
- 19-Oct-2024
Relations
- Effective Date
- 25-Jan-2023
Frequently Asked Questions
EN 61753-111-9:2010 is a standard published by CLC. Its full title is "Fibre optic interconnecting devices and passive components - Performance standard - Part 111-9: Sealed closures for category S - Subterranean". This standard covers: IEC 61753-111-9:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category S - subterranean, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
IEC 61753-111-9:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category S - subterranean, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
EN 61753-111-9:2010 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61753-111-9:2010 has the following relationships with other standards: It is inter standard links to EN IEC 61753-111-09:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61753-111-9:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2010
2SWLþQLVSRMQLHOHPHQWLLQSDVLYQHNRPSRQHQWH,]YHGEHQLVWDQGDUGGHO
=DWHVQMHQHVSRMQLFH]DNDWHJRULMR66XEWHUUDQHDQ3RG]HPQDXSRUDED,(&
Fibre optic interconnecting devices and passive components - Performance standard -
Part 111-9: Sealed closures for category S - Subterranean (IEC 61753-111-9:2009)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil
111-9: Druckdichte Muffen für die Kategorie S - unterirdische Verlegung (IEC 61753-111-
9:2009)
Dispositifs d'interconnexion et composants passifs à fibres optiques norme de qualité de
fonctionnement - Partie 111-9: Boîtiers scellés pour catégorie S - Souterrain (CEI 61753-
111-9:2009)
Ta slovenski standard je istoveten z: EN 61753-111-9:2010
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61753-111-9
NORME EUROPÉENNE
February 2010
EUROPÄISCHE NORM
ICS 33.180.20
English version
Fibre optic interconnecting devices and passive components
performance standard -
Part 111-9: Sealed closures for category S -
Subterranean
(IEC 61753-111-9:2009)
Dispositifs d'interconnexion et composants Lichtwellenleiter - Verbindungselemente
passifs à fibres optiques norme und passive Bauteile -
de qualité de fonctionnement - Betriebsverhalten -
Partie 111-9: Boîtiers scellés Teil 111-9: Druckdichte Muffen
pour catégorie S - Souterrain für die Kategorie S -
(CEI 61753-111-9:2009) unterirdische Verlegung
(IEC 61753-111-9:2009)
This European Standard was approved by CENELEC on 2010-02-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61753-111-9:2010 E
Foreword
The text of document 86B/2906/FDIS, future edition 1 of IEC 61753-111-9, prepared by SC 86B, Fibre
optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61753-111-9 on 2010-02-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2010-11-01
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2013-02-01
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61753-111-9:2009 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60068-1 NOTE Harmonized as EN 60068-1.
IEC 60068-2 NOTE Harmonized in EN 60068-2 series (not modified).
IEC 60721-3-1 NOTE Harmonized as EN 60721-3-1.
IEC 60793-2 NOTE Harmonized as EN 60793-2.
IEC 60794-1-2 NOTE Harmonized as EN 60794-1-2.
IEC 60794-2 NOTE Harmonized as EN 60794-2.
IEC 60794-3 NOTE Harmonized as EN 60794-3.
IEC 61300 NOTE Harmonized in EN 61300 series (not modified).
IEC 62005 NOTE Harmonized in EN 62005 series (not modified).
__________
- 3 - EN 61753-111-9:2010
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60068-2-10 - Environmental testing - EN 60068-2-10 -
Part 2-10: Tests - Test J and guidance: Mould
growth
IEC 60721-3-2 - Classification of environmental conditions - EN 60721-3-2 -
Part 3: Classification of groups of
environmental parameters
and their severities - Section 2: Transportation
IEC 60793-2-50 2008 Optical fibres - EN 60793-2-50 2008
Part 2-50: Product specifications - Sectional
specification for class B single-mode fibres
IEC 61300-1 - Fibre optic interconnecting devices and EN 61300-1 -
passive components - Basic test and
measurement procedures -
Part 1: General and guidance
IEC 61300-2-1 - Fibre optic interconnecting devices and EN 61300-2-1 -
passive components - Basic test and
measurement procedures -
Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-4 - Fibre optic interconnecting devices and EN 61300-2-4 -
passive components - Basic test and
measurement procedures -
Part 2-4: Tests - Fibre/cable retention
IEC 61300-2-5 - Fibre optic interconnecting devices and EN 61300-2-5 -
passive components - Basic test and
measurement procedures -
Part 2-5: Tests - Torsion
IEC 61300-2-9 - Fibre optic interconnecting devices and EN 61300-2-9 -
passive components - Basic test and
measurement procedures -
Part 2-9: Tests - Shock
IEC 61300-2-10 - Fibre optic interconnecting devices and EN 61300-2-10 -
passive components - Basic test and
measurement procedures -
Part 2-10: Tests - Crush resistance
IEC 61300-2-11 - Fibre optic interconnecting devices and EN 61300-2-11 -
passive components - Basic test and
measurement procedures -
Part 2-11: Tests - Axial compression
IEC 61300-2-12 2009 Fibre optic interconnecting devices and EN 61300-2-12 2009
passive components - Basic test and
measurement procedures -
Part 2-12: Tests - Impact
Publication Year Title EN/HD Year
IEC 61300-2-22 - Fibre optic interconnecting devices and EN 61300-2-22 -
passive components - Basic test and
measurement procedures -
Part 2-22: Tests - Change of temperature
IEC 61300-2-23 - Fibre optic interconnecting devices and EN 61300-2-23 -
passive components - Basic test and
measurement procedures -
Part 2-23: Tests - Sealing for non-pressurized
closures of fibre optic devices
IEC 61300-2-26 - Fibre optic interconnecting devices and EN 61300-2-26 -
passive components - Basic test and
measurement procedures -
Part 2-26: Tests - Salt mist
IEC 61300-2-33 - Fibre optic interconnecting devices and EN 61300-2-33 -
passive components - Basic test and
measurement procedures -
Part 2-33: Tests - Assembly and disassembly
of fibre optic closures
IEC 61300-2-34 - Fibre optic interconnecting devices and EN 61300-2-34 -
passive components - Basic test and
measurement procedures -
Part 2-34: Tests - Resistance to solvents and
contaminating fluids of interconnecting
components and closures
IEC 61300-2-37 - Fibre optic interconnecting devices and EN 61300-2-37 -
passive components - Basic test and
measurement procedures -
Part 2-37: Tests - Cable bending for fibre optic
closures
IEC 61300-2-38 2006 Fibre optic interconnecting devices and EN 61300-2-38 2006
passive components - Basic test and
measurement procedures -
Part 2-38: Tests - Sealing for pressurized fibre
optic closures
IEC 61300-3-1 - Fibre optic interconnecting devices and EN 61300-3-1 -
passive components - Basic test and
measurement procedures -
Part 3-1: Examinations and measurements -
Visual examination
IEC 61300-3-3 2009 Fibre optic interconnecting devices and EN 61300-3-3 2009
passive components - Basic test and
measurement procedures -
Part 3-3: Examinations and measurements -
Active monitoring of changes in attenuation
and return loss
IEC 61300-3-28 - Fibre optic interconnecting devices and EN 61300-3-28 -
passive components - Basic test and
measurement procedures -
Part 3-28: Examinations and measurements -
Transient loss
IEC 61753-1 2007 Fibre optic interconnecting devices and EN 61753-1 2007
passive components performance standard -
Part 1: General and guidance for performance
standards
- 5 - EN 61753-111-9:2010
Publication Year Title EN/HD Year
IEC 61753-111-7 - Fibre optic interconnecting devices and EN 61753-111-7 -
passive components - Performance standard -
Part 111-7: Sealed closures for category A -
Aerial
IEC 62134-1 - Fibre optic interconnecting devices and EN 62134-1 -
passive components - Fibre optic closures -
Part 1: Generic specification
ISO 1998 Series Petroleum industry - Terminology - -
ISO 4892-3 2006 Plastics - Methods of exposure to laboratory EN ISO 4892-3 2006
light sources -
Part 3: Fluorescent UV lamps
IEC 61753-111-9 ®
Edition 1.0 2009-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components performance
standard –
Part 111-9: Sealed closures for category S – Subterranean
Dispositifs d'interconnexion et composants passifs à fibres optiques norme de
qualité de fonctionnement –
Partie 111-9: Boîtiers scellés pour catégorie S – Souterrain
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
T
CODE PRIX
ICS 33.180.20 ISBN 2-8318-1067-5
– 2 – 61753-111-9 © IEC:2009
CONTENTS
FOREWORD.3
INTRODUCTION.5
1 Scope.6
2 Normative references.6
3 Terms, definitions and abbreviations .8
4 General requirements .8
4.1 Storage, transportation and packaging .8
4.2 Marking and identification .8
4.3 Materials .8
4.4 Closure overpressure safety .9
4.5 Test report.9
5 Test.9
5.1 General .9
5.2 Test specimen preparation.9
5.3 Test and measurement methods .10
5.4 Installation or intervention.10
5.5 Pass/fail criteria.10
6 Performance requirements.11
6.1 Sample size.11
6.2 Sealing, optical and appearance performance criteria .11
6.3 Mechanical sealing performance requirements.12
6.4 Environmental sealing performance requirements .14
6.5 Mechanical optical performance requirements.15
6.6 Environmental optical performance requirements .17
Annex A (normative) Sample definition .18
Annex B (normative) Sample size.20
Annex C (normative) Intervention and reconfiguration/resplicing .22
Bibliography .24
Figure A.1 – Track joint configuration sample .18
Figure A.2 – Distribution joint configuration sample.19
Table 1 – Tightness, optical and appearance performance criteria .11
Table 2 – Mechanical sealing performance requirements .12
Table 3 – Environmental sealing performance requirements .14
Table 4 – Mechanical optical performance requirements.15
Table 5 – Environmental optical performance requirements .17
Table A.1 – Fibre type for testing.18
Table B.1 – Sample size.20
61753-111-9 © IEC:2009 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS
PERFORMANCE STANDARD –
Part 111-9: Sealed closures for category S –
Subterranean
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61753-111-9 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2906/FDIS 86B/2936/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 4 – 61753-111-9 © IEC:2009
A list of all parts of IEC 61753 series, published under the general title Fibre optic
interconnecting devices and passive components – Performance standard, can be found on the
IEC website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
61753-111-9 © IEC:2009 – 5 –
INTRODUCTION
Performance standards for closures define the requirements for standard optical performance
under a set of specified conditions. This part of IEC 61753 contains a series or a set of tests
and measurements with clearly stated conditions, severities and pass/fail criteria. The set of
tests are intended to be a basis to prove the product’s ability to satisfy the requirements of a
specific application, market sector or user group.
A product that has been shown to meet all the requirements of this performance standard may
be declared as complying with this performance standard. Products having the same
classification from one manufacturer that satisfy this performance standard will operate within
the boundaries set by the performance standard. There is no guarantee that products from
different manufacturers, having the same classification and which conform to the same
performance standard, will provide an equivalent level of performance when they are used
together.
Conformance with IEC environmental policy according to IEC Guide 109 and concerning the
need to reduce the impact on the natural environment of fibre optic closures during all phases
of their life – from acquiring materials to manufacturing, distribution, use, and end-of-life
treatment (i.e. re-use, recycling (recovery and disposal)) are not part of this standard, but will
be covered in the generic specification.
Conformance to a performance standard demonstrates that a product has passed a design
verification test. It is not a guarantee of lifetime assured performance or reliability. Reliability
testing must be the subject of a separate test schedule, where the tests and severities selected
are such that they are truly representative of the requirements of this reliability test programme.
Consistency of manufacture should be maintained using a recognised Quality Assurance
programme whilst the reliability of product should be evaluated using the procedures
recommended in IEC 62005 series.
Tests and measurements are selected from the IEC 61300 series.
– 6 – 61753-111-9 © IEC:2009
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS
PERFORMANCE STANDARD –
Part 111-9: Sealed closures for category S –
Subterranean
1 Scope
This part of IEC 61753 contains the minimum test and measurement requirements and
severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting
the IEC standard for category S – subterranean, as defined in Annex A of IEC 61753-1. Free
breathing closures are not covered in this standard.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60068-2-10, Environmental testing – Part 2-10: Tests – Test J and guidance: Mould growth
IEC 60721-3-2, Classification of environmental conditions – Part 3: Classification of groups of
environmental parameters and their severities – Section 2: Transportation
IEC 60793-2-50:2008, Optical fibres – Part 2-50 : Product specifications – Sectional
specification for class B single-mode fibres
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-5, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-5: Tests – Torsion (only available in English)
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock
IEC 61300-2-10, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-10: Tests – Crush resistance
___________
This publication was withdrawn in 2002. A project is currently under consideration.
61753-111-9 © IEC:2009 – 7 –
IEC 61300-2-11, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-11: Tests – Axial compression
IEC 61300-2-12:2009, Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures – Part 2-12: Tests – Impact
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-23, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-23: Tests – Sealing for non-pressurized closures of fibre
optic devices
IEC 61300-2-26, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-26: Tests – Salt mist
IEC 61300-2-33, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic
closures
IEC 61300-2-34, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-34: Tests – Resistance to solvents and contaminating fluids
of interconnecting components and closures (only available in English)
IEC 61300-2-37, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-37: Tests – Cable bending for fibre optic closures
IEC 61300-2-38:2006, Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures – Part 2-38: Tests – Sealing for pressurized fibre optic
closures
IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-1: Examinations and measurements – Visual examination
IEC 61300-3-3:2009, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-3: Examinations and measurements – Active monitoring
of changes in attenuation and return loss (only available in English)
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-28: Examinations and measurements – Transient loss
IEC 61753-1:2007, Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
IEC 61753-111-7, Fibre optic interconnecting devices and passive components – Performance
standard – Part 111-7: Sealed closures for category A – Aerial
IEC 62134-1, Fibre optic interconnecting devices and passive components – Fibre optic
closures – Part 1: Generic specification
ISO 1998 (all parts), Petroleum industry – Terminology
___________
This publication was withdrawn in 2002. A project is currently under consideration.
– 8 – 61753-111-9 © IEC:2009
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part
3:Fluorescent UV lamps
3 Terms, definitions and abbreviations
For the purposes of this document, the terms, definitions and abbreviations given in
IEC 61753-111-7 apply.
4 General requirements
4.1 Storage, transportation and packaging
The classes of environmental conditions and their severities to which closures may be exposed
during transportation are defined in IEC 60721-3-2. Normal transportation time is considered to
be 30 days or less.
The product, in its original packaging, shall be suitable for normal public or commercial
transportation and storage in weather protected non-temperature controlled storage
environments.
4.2 Marking and identification
Marking of the closure and its package shall be according to IEC 62134-1.
Product marking and identification shall survive the storage and transportation.
Each test sample should contain the following information at a minimum:
– manufacturer’s identification mark or logo;
– product designation, model or type,
– one of the following: lot number, batch number, date (at least month and year) of production
or serial number;
– expiry date (at least year) if the product contains components with a limited shelf life.
4.3 Materials
For all applied materials, a Material Safety Data Sheet shall be made available upon request.
The materials of the closure and fibre management system shall be compatible with the other
materials or solvents that can come into contact with it, for example cable filling compounds
and degreasing agents.
All materials that can come in contact with personnel shall meet appropriate health and safety
regulations.
The effect of UV light on all polymeric materials that are directly exposed to the environment,
shall not adversely affect the product’s performance. UV test shall be according to ISO 4892-3
Mode 1 lamp type 2. The effect of UV light shall be determined by measuring a suitable
property (e.g. tensile strength) both before and after exposure of the material slabs.
Polymeric materials shall not support mould growth causing mechanical degradation of the
materials. Mould growth shall be tested according to IEC 60068-2-10. The effect of mould
growth shall be determined by measuring a suitable property (e.g. tensile strength) both before
and after exposure of the material slabs.
...