Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies

This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE. This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard. The requirements correspond to each of the four security grades given in the European Standard EN 50131 1, Alarm Systems - Intrusion and Hold-Up Systems - Part 1: System requirements. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations. This standard covers: a) mandatory functions which will be provided on all PS; and b) optional functions which may be provided. This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions and reduced functional test for EMC susceptibility testing as required by EN 50130 4. Other functions associated with I&HAS not specified in this standard may be provided. Such functions will not affect the requirements of any mandatory or optional functions.

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen

Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 6: Alimentation

La présente Norme européenne spécifie les exigences, les critères de performance et les procédures d’essai pour les PS destinées à être utilisées comme partie de systèmes d’alarme contre l’intrusion et les hold-up. La PS est intégrée à un composant d’un I&HAS ou un ensemble séparé. Les fonctions de commande de la PS peuvent être intégrées comme partie du dispositif de la PS, ou peuvent être fournies par un autre composant de l’I&HAS, par exemple un CIE. La présente Norme européenne ne s’applique pas lorsque les exigences de la PS pour des composants d’un I&HAS sont incluses dans la norme de produit applicable. Les exigences correspondent à chacun des quatre grades de sécurité donnés dans la Norme européenne EN 50131-1, Systèmes d’alarme - Systèmes d’alarme contre l’intrusion et les hold-up - Partie 1: Exigences système. Des exigences sont également données pour les quatre classes d’environnement couvrant les applications localisées en intérieur et en extérieur. La présente norme couvre: a) les fonctions obligatoires fournies sur toutes les PS; et b) les fonctions facultatives pouvant être fournies. La présente Norme européenne ne couvre pas les exigences de conformité aux directives réglementaires CE, comme la directive CEM, la directive Basse Tension, etc., mais elle spécifie les conditions de fonctionnement des matériels et l’essai fonctionnel réduit en ce qui concerne les essais de susceptibilité CEM comme cela est exigé par l’EN 50130-4. D’autres fonctions associées à un I&HAS, non spécifiées dans la présente norme, peuvent être fournies. Ces fonctions n’ont pas de conséquence sur une quelconque des exigences relatives aux fonctions obligatoires ou facultatives.

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6 del: Napajalniki

Ta evropski standard določa zahteve, merila uspešnosti in preskusne postopke za napajalnike za uporabo kot del alarmnega sistema za javljanje vloma in ropa. Napajalnik je lahko sestavni del komponente I&HAS ali samostojen. Krmilne funkcije napajalnika je mogoče vključiti kot del napajalne naprave ali pa jih lahko zagotavlja drug sestavni del I&HAS, npr. CIE.
Ta evropski standard se ne uporablja, kadar so zahteve napajalnika za sestavne dele I&HAS zajete v ustreznem standardu za proizvode.
Zahteve ustrezajo vsem štirim varnostnim razredom, ki so navedeni v evropskem standardu EN 50131-1 Alarmni sistemi - Sistemi za javljanje vloma in ropa - 1. del: Sistemske zahteve. Zahteve so podane tudi za štiri okoljske razrede, ki zajemajo uporabe v notranjih in zunanjih lokacijah.
Ta standard vključuje:
a) obvezne funkcije, ki so na voljo pri vseh napajalnikih; in
b) izbirne funkcije, ki so lahko na voljo.
Ta evropski standard ne obravnava zahtev glede skladnosti z regulativnimi direktivami ES, kot je direktiva o elektromagnetni združljivosti, direktiva o nizki napetosti itd., določa pa pogoje za uporabo opreme za preskušanje občutljivosti v okviru elektromagnetne združljivosti, kot to zahteva standard EN 50130-4.
Morda so na voljo druge funkcije, povezane z I&HAS, ki niso navedene v tem standardu. Take funkcije ne smejo vplivati na zahteve obveznih ali izbirnih funkcij.

General Information

Status
Published
Publication Date
26-Oct-2017
Withdrawal Date
17-Sep-2020
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
07-Dec-2022

Relations

Buy Standard

Standard
EN 50131-6:2018
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2018
1DGRPHãþD
SIST EN 50131-6:2008
SIST EN 50131-6:2008/A1:2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6 del: Napajalniki
Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen
Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 6:
Alimentation
Ta slovenski standard je istoveten z: EN 50131-6:2017
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50131-6
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2017
ICS 13.310 Supersedes EN 50131-6:2008
English Version
Alarm systems - Intrusion and hold-up systems - Part 6: Power
supplies
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 6: Alimentation 6: Energieversorgungen
This European Standard was approved by CENELEC on 2017-09-18. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50131-6:2017 E
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references. 6
3 Terms, definitions and abbreviations . 7
3.1 Terms and definitions . 7
3.2 Abbreviations . 9
4 Functional requirements . 9
4.1 PS configurations . 9
4.2 General requirements .10
4.3 Monitoring of PS .13
4.4 APS capability .17
4.5 Recharging for PS Type A .17
4.6 Over-voltage protection .18
4.7 Short circuit protection.18
4.8 Overload protection .18
4.9 Deep discharge protection .18
4.10 Ripple .18
4.11 Tamper security .18
4.12 Environmental .21
4.13 Safety .22
4.14 EMC susceptibility .22
4.15 Electrical .22
5 Marking .23
6 Documentation .23
7 Tests .24
7.1 General .24
7.2 General test conditions .25
7.3 Reduced functional test .26
7.4 Monitoring: Loss of EPS .26
7.5 Monitoring: Storage Device Low Residual Energy .27
7.6 Monitoring: Storage Device Failure .30
7.7 Monitoring: Low Output Voltage .30
7.8 Monitoring: Power Unit Failure – Loss of PU Power Output .31
7.9 Monitoring: Power Unit Failure – Loss of SD Recharge .32
7.10 Test on demand .32
7.11 APS Capability .33
7.12 Recharging for PS Type A .34
7.13 Over voltage protection .35
7.14 Short Circuit Protection .36
7.15 Overload Protection .37
7.16 Deep Discharge Protection .38
7.17 Tamper security - Protection .39
7.18 Tamper Detection – Access to inside of the housing .39
7.19 Tamper detection – Removal from mounting .40
7.20 Tamper detection – Penetration of the housing .41
7.21 Environmental and EMC .42
7.22 PS Rating .42
7.23 Output voltage stability - Gradual load variation .45
7.24 Output Voltage Stability – Switched Load Variation .46
7.25 Marking and Documentation .47
Annex A (informative) Determination of Storage Device failure .48
Annex B (normative) Measurement of ripple voltage .49
B.1 General .49
B.2 Principle .49
B.3 Test conditions .49
B.4 Measurement .49
B.5 Pass/Fail Criteria .49
Annex C (normative) Measurement of transients .50
C.1 General .50
C.2 Principle .50
C.3 Test conditions .50
C.4 Measurement .50
C.5 Pass/Fail Criteria .50
Annex D (informative) Test on Demand signal or message timing and usage protocol .51
Annex E (informative) Cross-reference between requirements and corresponding tests .52

European foreword
This document (EN 50131-6:2017) has been prepared by CLC/TC 79 “Alarm systems”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2018-09-18
implemented at national level by publication of an
identical national standard or by endorsement
• latest date by which the national standards (dow) 2020-09-18
conflicting with this document have to
be withdrawn
This document supersedes EN 50131-6:2008.
The revision is to make the document less technology specific and more inclusive of the different
types of power supplies found in I&HAS and the different types of technologies that are, and can be,
employed within a power supply. It will make the document easier to use and more clearly applicable
to the range of PSU configurations to be found in I&HAS.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Introduction
This European Standard deals with power supplies (PS) of intrusion and hold-up alarm systems
(I&HAS) installed in buildings. It includes devices that are installed inside or outside of the supervised
premises and mounted in indoor or outdoor environments.
The PS may be fully contained in its own housing or it may be integrated with other components within
an I&HAS, e.g. the control and indicating equipment (CIE).
An I&HAS may use one or more PS.
1 Scope
This European Standard specifies the requirements, performance criteria and testing procedures for
PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of
an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of
the PS device, or may be provided by another I&HAS component, e.g. a CIE.
This European Standard is not applicable when the PS requirements for I&HAS components are
included within the relevant product standard.
The requirements correspond to each of the four security grades given in the European Standard
EN 50131-1, Alarm Systems – Intrusion and Hold-Up Systems – Part 1: System requirements.
Requirements are also given for four environmental classes covering applications in indoor and
outdoor locations.
This standard covers:
a) mandatory funct
...