Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room

IEC 60965:2016 establishes requirements for the Supplementary Control Room provided to enable the operating staff of nuclear power plants to shut down the reactor, where previously operating, and maintain the plant in a safe shut-down state in the event that control of the safety functions can no longer be exercised from the Main Control Room, due to unavailability of the Main Control Room or its facilities. The design has to ensure that the Supplementary Control Room is protected against the hazards, including any localised extreme hazards, leading to the unavailability of the Main Control Room. This new edition includes the following significant technical changes with respect to the previous edition: - requirements associated with regular testing of the supplementary control room (SCR); - requirements to assess the time available during which the reactor will be safe but unattended, in order to move from the main control room (MCR) to the SCR and for the SCR to become operational; - taking into account new requirements laid down by the IAEA.

Kernkraftwerke - Warten - Notsteuerstelle für das Abfahren des Reaktors ohne Verbindung zur Hauptwarte

Centrales nucléaires de puissance - Salles de commande - Salle de commande supplémentaire pour l’arrêt des réacteurs sans accès à la salle de commande principale

L'IEC 60965:2016 établit des exigences applicables à la salle de commande supplémentaire permettant au personnel d'exploitation des centrales nucléaires d'arrêter le réacteur, si celui-ci était en fonctionnement, et de maintenir l'installation dans un état d'arrêt sûr, pour le cas où les fonctions de sûreté ne pourraient plus être commandées de la salle de commande principale, en cas d'indisponibilité de celle-ci ou de ses équipements. La conception doit garantir que la salle de commande supplémentaire est protégée contre les risques, y compris les risques extrêmes locaux, entraînant l'indisponibilité de la salle de commande principale. Cette norme fournit aussi des exigences pour le choix des fonctions, la conception et l'organisation de l'interface homme-machine, ainsi que des procédures qui doivent être utilisées systématiquement pour vérifier et valider la conception fonctionnelle de la salle de commande supplémentaire. Les principales modifications techniques par rapport à l'édition précédente sont les suivantes: - exigences portant sur les essais classiques réalisés sur les SCS (salles de commande supplémentaires); - exigences permettant d'évaluer le temps disponible durant lequel le réacteur est en état sûr mais non surveillé, de façon à pouvoir se rendre de la SCP (salle de commande principale) à la SCS et à ce que la SCS devienne opérationnelle; - prise en compte de nouvelles exigences définies par l'AIEA.

Jedrske elektrarne - Nadzorne sobe - Dodatne nadzorne točke za prekinitev obratovanja reaktorja brez dostopa do glavne nadzorne sobe (IEC 60965:2016)

Ta mednarodni standard določa zahteve za dodatno nadzorno sobo, iz katere lahko operativno osebje jedrske elektrarne prekine obratovanje reaktorja in ohranja stanje njene varne zaustavitve, kadar nadzor varnostnih funkcij iz glavne nadzorne sobe ni več mogoč zaradi nerazpoložljivosti glavne nadzorne sobe ali njenih predelov. Dodatna nadzorna soba mora biti zasnovana tako, da zagotavlja zaščito pred nevarnostmi, vključno z morebitnimi lokaliziranimi izrednimi nevarnostmi, zaradi katerih glavna nadzorna soba ni razpoložljiva.
Standard določa tudi zahteve za izbiro funkcij, zasnove in ureditve vmesnika človek-stroj ter postopke, ki se morajo sistematično uporabljati za preverjanje in validacijo funkcionalne zasnove dodatne nadzorne sobe. Predvideva se, da se dodatna nadzorna soba, ki je na voljo za izvajanje postopkov zaustavitve zunaj glavne nadzorne sobe, v času običajnega obratovanja elektrarne ne uporablja, razen za namene rednega preskušanja. Zahteve odražajo uporabo načel človeškega inženiringa, saj se uporabljajo za vmesnik človek-stroj pri tovrstnem rednem preskušanju in neobičajnih pogojih v elektrarni.
Ta standard ne obravnava posebnih prostorov za odziv na izredne razmere (npr. center za tehnično podporo) ali prostorov, namenjenih za ravnanje z radioaktivnimi odpadki. Zunaj področja uporabe tega standarda je tudi podrobna zasnova opreme.
Ta standard upošteva načela posebnih varnostnih zahtev SSR-2/1 in varnostnih napotkov NS-G-1.3 Mednarodne agencije za atomsko energijo (IAEA).
Namen tega standarda je podajanje zahtev glede funkcionalne zasnove, ki se uporabljajo pri zasnovi dodatne nadzorne sobe jedrske elektrarne za izpolnitev varnostnih zahtev.
Ta standard je namenjen za uporabo za dodatno nadzorno sobo, katere konceptualna zasnova je vzpostavljena po izdaji tega standarda. Če ga želite uporabiti za obstoječe elektrarne ali zasnove, bodite še posebej previdni pri zagotavljanju dosledne podlage za zasnovo. To se navezuje na primer na dejavnike, kot je doslednost med dodatno nadzorno sobo in glavno nadzorno sobo, ergonomski vidik, stopnjo avtomatizacije in informacijsko tehnologijo, ter obseg sprememb za uvajanje v merilnih in nadzornih sistemih.

General Information

Status
Published
Publication Date
15-Sep-2016
Withdrawal Date
17-Jul-2019
Current Stage
6060 - Document made available - Publishing
Start Date
16-Sep-2016
Due Date
28-Jan-2018
Completion Date
16-Sep-2016

Relations

Buy Standard

Standard
EN 60965:2016
English language
24 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2016
1DGRPHãþD
SIST EN 60965:2011
-HGUVNHHOHNWUDUQH1DG]RUQHVREH'RGDWQHQDG]RUQHWRþNH]DSUHNLQLWHY
REUDWRYDQMDUHDNWRUMDEUH]GRVWRSDGRJODYQHQDG]RUQHVREH ,(&
Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown
without access to the main control room (IEC 60965:2016)
Kernkraftwerke - Warten - Notsteuerstelle für das Abfahren des Reaktors ohne
Verbindung zur Hauptwarte (IEC 60965:2016)
Centrales nucléaires de puissance - Salles de commande - Salle de commande
supplémentaire pour l’arrêt des réacteurs sans accès à la salle de commande principale
(IEC 60965:2016)
Ta slovenski standard je istoveten z: EN 60965:2016
ICS:
27.120.20 Jedrske elektrarne. Varnost Nuclear power plants. Safety
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60965
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2016
ICS 27.120.20 Supersedes EN 60965:2011
English Version
Nuclear power plants - Control rooms - Supplementary control
room for reactor shutdown without access to the main control
room
(IEC 60965:2016)
Centrales nucléaires de puissance - Salles de commande - Kernkraftwerke - Warten - Notsteuerstelle für das Abfahren
Salle de commande supplémentaire pour l'arrêt des des Reaktors ohne Verbindung zur Hauptwarte
réacteurs sans accès à la salle de commande principale (IEC 60965:2016)
(IEC 60965:2016)
This European Standard was approved by CENELEC on 2016-07-18. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60965:2016 E
European foreword
This document (EN 60965:2016) consists of the text of IEC 60965:2016 prepared by
SC 45A “Instrumentation, control and electrical systems of nuclear facilities” of IEC/TC 45 “Nuclear
instrumentation".
The following dates are fixed:
(dop) 2017-07-18
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2019-07-18
standards conflicting with the
document have to be withdrawn
This document supersedes EN 60965:2011.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
As stated in the nuclear safety directive 2009/71/EURATOM, Chapter 1, Article 2, item 2, Member
States are not prevented from taking more stringent safety measures in the subject-matter covered by
the Directive, in compliance with Community law. In a similar manner, this European standard does
not prevent Member States from taking more stringent nuclear safety measures in the subject-matter
covered by this standard.
Endorsement notice
The text of the International Standard IEC 60965:2016 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 60880 NOTE Harmonized as EN 60880.
IEC 61227 NOTE Harmonized as EN 61227.
IEC 61508-1 NOTE Harmonized as EN 61508-1.
IEC 61508-2 NOTE Harmonized as EN 61508-2.
IEC 61508-3 NOTE Harmonized as EN 61508-3.
IEC 61508-4 NOTE Harmonized as EN 61508-4.
IEC 61772 NOTE Harmonized as EN 61772.
IEC 61839 NOTE Harmonized as EN 61839.
IEC 62138 NOTE Harmonized as EN 62138.
IEC 62241 NOTE Harmonized as EN 62241.
IEC 9241 Series NOTE Harmonized as EN ISO 9241 Series.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year

IEC 60709 -  Nuclear power plants - Instrumentation EN 60709 -
and control systems important to safety -
Separation
IEC 60964 2009 Nuclear power plants - Control rooms - EN 60964 2010
Design
IEC 61226 -  Nuclear power plants - Instrumentation EN 61226 -
and control important to safety -
Classification of instrumentation and
control functions
IEC 61513 -  Nuclear power plants - Instrumentation EN 61513 -
and control important to safety - General
requirement for systems
IEC 61771 -  Nuclear power plants - Main control-room - - -
Verification and validation of design
IEC 62646 -  Nuclear power plants - Control rooms - - -
Computer based procedures
ISO 11064 Series Ergonomic design of control centres EN ISO 11064 Series
ISO 11064-1 -  Ergonomic design of control centres - EN ISO 11064-1 -
Part 1: Principles for the design of control
centres
ISO 11064-3 -  Ergonomic design of control centres - EN ISO 11064-3 -
Part 3: Control room layout
ISO 11064-6 -  Ergonomic design of control centres - EN ISO 11064-6 -
Part 6: Environmental requirements for
control centres
IAEA SSR-2/1 2012 Safety of nuclear power plants: Design
IAEA NS-G-1.3 2002 Instrumentation and Control Systems
Important to Safety in Nuclear Power
Plants (to be replaced by SSG-39)

IEC 60965 ®
Edition 3.0 2016-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Nuclear power plants – Control rooms – Supplementary control room for reactor

shutdown without access to the main control room

Centrales nucléaires de puissance – Salles de commande – Salle de commande

supplémentaire pour l’arrêt des réacteurs sans accès à la salle de commande

principale
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 27.120.20 ISBN 978-2-8322-3203-3

– 2 – IEC 60965:2016 © IEC 2016
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 7
2 Normative references. 7
3 Terms and definitions . 8
4 Abbreviations . 9
5 Design principles . 9
5.1 General . 9
5.2 Main objectives . 10
5.3 Safety principles . 11
5.3.1 Design basis and design extension conditions . 11
5.3.2 Functionality and qualification . 12
5.3.3 Accessibility and operator transfer time . 12
5.3.4 Control transfer, control prioritisation and security . 12
5.3.5 Operational considerations . 13
5.4 Human factors engineering principles . 14
6 Design process . 14
7 Functional design . 15
7.1 General . 15
7.2 Human factors . 15
7.3 Location and access route . 15
7.4 SCR environment . 16
7.5 Space and configuration . 16
7.6 Information and control equipment . 17
7.7 Communication systems . 17
7.8 Other equipment . 18
7.9 Testing and inspection . 18
8 System verification and validation . 18
Annex A (informative) Assessment of safe transfer time window . 20
Bibliography . 21

IEC 60965:2016 © IEC 2016 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
NUCLEAR POWER PLANTS – CONTROL ROOMS –
SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN
WITHOUT ACCESS TO THE MAIN CONTROL ROOM

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that the
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.