FprEN IEC 62877-1:2023
(Main)Electrolyte and water for vented lead acid accumulators - Part 1: Requirements for electrolyte
Electrolyte and water for vented lead acid accumulators - Part 1: Requirements for electrolyte
IEC 62877-1:2023 is available as IEC 62877-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62877-1:2023 applies to electrolytes and their components used for filling vented lead acid batteries with dry-charged cells and for electrolyte replenishment, replacement or electrolyte density adjustment of batteries in operation. This document defines the composition, purity and properties of electrolyte, for application where specific instructions from the battery manufacturer are not available. This second edition cancels and replaces the first edition published in 2016. This edition includes the following significant technical changes with respect to the previous edition: - Addition of the concentration values of halogens in Table 4.
Elektrolyt und Wasser für geschlossene Blei-Akkumulatoren - Teil 1: Anforderungen an den Elektrolyt
Electrolyte et eau pour accumulateurs plomb-acide ouverts - Partie 1: Exigences pour l'électrolyte
IEC 62877-1:2023 est disponible sous forme de IEC 62877-1:2023 RLV qui contient la Norme internationale et sa version Redline, illustrant les modifications du contenu technique depuis l'édition précédente.L' IEC 62877-1:2023 s'applique aux électrolytes et à leurs composants utilisés pour le remplissage des batteries plomb-acide ouvertes avec éléments chargés secs et pour le réapprovisionnement, le remplacement de l'électrolyte ou le réglage de la densité de l'électrolyte des batteries en fonctionnement. Le présent document définit la composition, la pureté et les propriétés de l'électrolyte pour application en l'absence d'instructions spécifiques du fabricant de batteries. Cette deuxième édition annule et remplace la première édition parue en 2016. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - Ajout des valeurs de concentration des halogènes dans le Tableau 4.
Elektrolit in voda za oddušne svinčeve akumulatorje - 1. del: Zahteve za elektrolit
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN IEC 62877-1:2023
01-januar-2023
Elektrolit in voda za oddušne svinčeve akumulatorje - 1. del: Zahteve za elektrolit
Electrolyte and water for vented lead acid accumulators - Part 1: requirements for
electrolyte
Electrolyte et eau pour accumulateurs plomb-acide ouverts - Partie 1: Exigences pour
l'électrolyte
Ta slovenski standard je istoveten z: prEN IEC 62877-1:2022
ICS:
29.220.20 Kislinski sekundarni členi in Acid secondary cells and
baterije batteries
oSIST prEN IEC 62877-1:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN IEC 62877-1:2023
---------------------- Page: 2 ----------------------
oSIST prEN IEC 62877-1:2023
21/1158/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 62877-1 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2022-11-11 2023-02-03
SUPERSEDES DOCUMENTS:
21/1147/CD, 21/1152A/CC
IEC TC 21 : SECONDARY CELLS AND BATTERIES
SECRETARIAT: SECRETARY:
France Mr Yves Boudou
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:
Other TC/SCs are requested to indicate their interest, if any, in
this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which
they are aware and to provide supporting documentation.
TITLE:
Electrolyte and water for vented lead acid accumulators - Part 1: requirements for electrolyte
PROPOSED STABILITY DATE: 2028
NOTE FROM TC/SC OFFICERS:
Copyright © 2022 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to download this
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.
---------------------- Page: 3 ----------------------
oSIST prEN IEC 62877-1:2023
21/1158/CDV – 2 – IEC CDV 62877-1:2022 © IEC 2022
1 CONTENTS
2 CONTENTS . 2
3 FOREWORD . 3
4 1 Scope . 5
5 2 Normative references . 5
6 3 Terms and definitions . 5
7 4 Preparation of electrolyte for lead-acid accumulators . 7
8 5 Physical properties of diluted sulphuric acid as electrolyte . 8
9 5.1 Dependence of sulphuric acid electrolyte density on temperature . 8
10 5.2 Relationship of acid electrolyte density at 25 °C with the content of sulphuric
11 acid. 9
12 5.3 Electrolyte density in relation to the state of discharge . 9
13 6 Requirements for sulphuric acid used as electrolyte . 10
14 6.1 Impurities of sulphuric acid at high concentration . 10
15 6.2 Impurities limits of sulphuric acid electrolyte for first filling . 10
16 6.3 Impurities limits for sulphuric acid electrolyte in operation . 11
17 7 Storage of electrolyte . 12
18 8 Remedy in the event of damage due to electrolyte . 12
19 Bibliography . 13
20
21 Table 1 – Correction factor to convert the acid electrolyte density found at the
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.