Sectional Specification: Radio frequency coaxial connectors - Series MMCX

IEC/SC 46D projects transferred into IEC/SC 46F

Rahmenspezifikation: Hochfrequenz-Steckverbinder - Serie MMCX

Spécification intermédiaire: Connecteurs pour fréquence radioélectrique - Série MMCX

Področna specifikacija - Radiofrekvenčni koaksialni konektorji - Serija MMCX

General Information

Status
Withdrawn
Publication Date
21-Mar-2002
Withdrawal Date
31-Oct-2004
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
10-Jul-2018
Completion Date
10-Jul-2018

Relations

Buy Standard

Standard
EN 122340:2005
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


STANDARDPodročna specifikacija - Radiofrekvenčni koaksialni konektorji - Serija MMCXSectional specification: Radio frequency coaxial connectors - Series MMCX©
Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 122340:2005(en)ICS33.120.30

EUROPEAN STANDARDEN 122340NORME EUROPÉENNEEUROPÄISCHE NORMMarch 2002CENELECEuropean Committee for Electrotechnical StandardizationComité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2002 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 122340:2002 EICS 33.120.30English versionSectional Specification:Radio frequency coaxial connectors -Series MMCXSpécification intermédiaire:Connecteurs pour fréquenceradioélectrique -Série MMCXRahmenspezifikation:Hochfrequenz-Steckverbinder -Serie MMCXThis European Standard was approved by CENELEC on 2001-11-01. CENELEC members are bound tocomply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any otherlanguage made by translation under the responsibility of a CENELEC member into its own language andnotified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.

- 3 -EN 122340:2002ContentsPageCECC-specification system for HF connectors.
41Scope.
62Mating face and gauge information.
62.1Dimensions - General purpose connectors.
62.2Gauges for general purpose connectors.
72.3Dimensions - Standard test connectors (Grade 0).
103Properties.
113.1Ratings and characteristics.
114Quality assessment procedures.
144.1Test schedules and inspection requirements.
A detail specification is a ‘completed’ blank detail specification.

- 5 -EN 122340:2002Document numbering for RF connector specifications is in the process of conversion to conformwith CENELEC PNE Rules, affecting generic, sectional and blank detail specifications but notCECC detail specifications.Detail specifications (DS) shall be prepared using general blank detail specifications (BDS)EN 122001 (for military connectors), EN 122002 (for commercial connectors).When completed, the detail specification (DS) applicable to this sectional specification (SS) shallbe renumbered in accordance with 4.2 of CECC 00 700 (Section IV) Issue 1, as if a 'dedicatedBDS’ EN 122341 had been used.

1E---3,15F1,581,62Diameter
2G1,45---H0,380,42DiameterI---0,20Diameter

- 7 -EN 122340:2002NOTE 1Diameter of centre conductor and of uniform transmission line to give required characteristic impedanceof 50 Ω.NOTE 2Diameter chosen to meet mechanical and electrical requirements and to compensate for electrical effect ofslots.NOTE 3Angular tolerance ± 2 °.2.1.2SocketFigure 2 - Socket with female centre contactTable 2mmRef.min.max.NoteA2,41---DiameterB2,60---C0,901,20D2,322,35Diameter
1E1,40---F3,003,04DiameterG2,882,90DiameterH1,571,63I2,302,34K---0,23NOTE 1Diameter of centre conductor and of uniform section of transmission line to give required characteristicimpedance of 50 Ω.NOTE 2Bore diameter of centre conductor and closure to meet electrical and mechanical requirements.NOTE 3Angular tolerance ± 2°.2.2Gauges for general purpose connectorsMetric dimensions are original dimensions. All undimensioned pictorial configurations are forreference purposes only.

- 9 -EN 122340:20022.2.2Gauge for outer contact of plugFigure 4 - Outer contact retention and se
...