EN 60216-3-2:1995
(Main)Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups)
Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups)
Consists exclusively of calculation instuctions. A worked example, a computer program written in BASIC and appropriate statistical tables are given.
Leitlinie zur Bestimmung thermischer Langzeiteigenschaften von Elektroisolierstoffen - Teil 3: Vorschriften zur Berechnung thermischer Langzeitkennwerte - Hauptabschnitt 2: Berechnung für unvollständige Schwellwertsprüfergebnisse bis zu und einschließlich des Median für die Ausfallzeit (gleiche Prüfgruppen)
Guide pour la détermination des propriétés d'endurance thermique de matériaux isolants électriques - Partie 3: Instructions pour le calcul des caractéristiques d'endurance thermique - Section 2: Calculs applicables aux résultats incomplets: résultats des essais d'épreuve de durée inférieure ou égale au temps médian pour atteindre le point limite (groupes d'essai égaux)
Consiste exclusivement en instructions de calcul. Un exemple développé, un programme informatique écrit en BASIC et des tableaux statistiques sont donnés.
Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups) (IEC 60216-3-2:1993)
General Information
- Status
- Withdrawn
- Publication Date
- 18-Apr-1995
- Withdrawal Date
- 29-Feb-1996
- Technical Committee
- CLC/SR 15 - Insulating materials
- Drafting Committee
- IEC/TC 15 - IEC_TC_15
- Parallel Committee
- IEC/TC 15 - IEC_TC_15
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Mar-2005
- Completion Date
- 01-Mar-2005
Relations
- Effective Date
- 28-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
CESI Beijing Certification (Saisi)
Subsidiary of China Electronics Standardization Institute (CESI), established 1963.
Sponsored listings
Frequently Asked Questions
EN 60216-3-2:1995 is a standard published by CLC. Its full title is "Guide for the determination of thermal endurance properties of electrical insulating materials - Part 3: Instructions for calculating thermal endurance characteristics - Section 2: Calculations for incomplete data: proof test results up to and including the median time to end-point (equal test groups)". This standard covers: Consists exclusively of calculation instuctions. A worked example, a computer program written in BASIC and appropriate statistical tables are given.
Consists exclusively of calculation instuctions. A worked example, a computer program written in BASIC and appropriate statistical tables are given.
EN 60216-3-2:1995 is classified under the following ICS (International Classification for Standards) categories: 29.040.20 - Insulating gases. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60216-3-2:1995 has the following relationships with other standards: It is inter standard links to EN 60216-3:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60216-3-2:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-1998
Guide for the determination of thermal endurance properties of electrical
insulating materials - Part 3: Instructions for calculating thermal endurance
characteristics - Section 2: Calculations for incomplete data: proof test results up
to and including the median time to end-point (equal test groups) (IEC 60216-3-
2:1993)
Guide for the determination of thermal endurance properties of electrical insulating
materials -- Part 3: Instructions for calculating thermal endurance characteristics --
Section 2: Calculations for incomplete data: proof test results up to and including the
median time to end-point (equal test groups)
Leitlinie zur Bestimmung thermischer Langzeiteigenschaften von Elektroisolierstoffen --
Teil 3: Vorschriften zur Berechnung thermischer Langzeitkennwerte -- Hauptabschnitt 2:
Berechnung für unvollständige Schwellwertsprüfergebnisse bis zu und einschließlich des
Median für die Ausfallzeit (gleiche Prüfgruppen)
Guide pour la détermination des propriétés d'endurance thermique de matériaux isolants
électriques -- Partie 3: Instructions pour le calcul des caractéristiques d'endurance
thermique -- Section 2: Calculs applicables aux résultats incomplets: résultats des essais
d'épreuve de durée inférieure ou égale au temps médian pour atteindre le point limite
(groupes d'essai égaux)
Ta slovenski standard je istoveten z: EN 60216-3-2:1995
ICS:
29.035.01 Izolacijski materiali na Insulating materials in
splošno general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
-
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...