Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 2 A to 25 A, switching capacity 65 /n - Part 004: UNC thread terminals - Product standard

This standard specifies the required characteristics for three-pole, temperature compensated circuit breakers, rated currents from 2 A to 25 A, switching capacity 65 In, UNC thread terminals, for use in aircraft electrical systems. Their oprating temperatures are between -55°C and 125°C for rated currents equal or lower than 15 A and between -55°C and 90°C for rated currents higher than 15 A, at amaximum altitude of Z = 22 000 m. It shall be used together with EN 3774-001. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.

Luft- und Raumfahrt - Schutzschalter, dreipolig, temperaturkompensiert, Nennströme von 2 A bis 25 A, Schaltvermögen 65 /n - Teil 004: UNC-Klemmengewinde - Produktnorm

Diese Norm legt die Anforderungen an temperaturkompensierte, dreipolige Schutzschalter mit Nennströmen von 2A bis 25A, Schaltvermögen 65 In, mit UNC-Klemmengewinde, für den Einsatz in elektrischen Bordnetzen fest. Ihre Betriebstemperaturen liegen zwischen -55 °C und 125 °C für Nennströme, die kleiner oder gleich 15 A sind und zwischen -55 °C und 90 °C für Nennströme, die größer als 15 A sind, bis zu einer Höhe von Z = 22 000 m. Sie ist in Verbindung mit EN 3774-001 anzuwenden. Diese Schutzschalter sind zum Einsatz in Luftfahrzeugen mit elektrischer Stromversorgung nach EN 2282 bestimmt.

Série aérospatiale - Disjoncteurs tripolaires compensés en température, intensités nominales 2 A à 25 A, pouvoir de coupure 65 /n - Partie 004: Bornes à filetage UNC - Norme de produit

La présente norme spécifie les caractéristiques requises des disjoncteurs tripolaires compensés en température, d'intensités nominales 2 A à 25 A, pouvoir de coupure 65 In, bornes à filetage UNC, utilisés dans les circuits électriques à bord d'aéronefs. Leurs températures de fonctionnement sont comprises entre -55 °C et 125 °C pour les intensités nominales égales ou inférieures à 15 A et entre -55°C et 90 °C pour les intensités nominales supérieures à 15 A, à une altitude Z = 22000 m. Elle doit être utilisée conjointement avec EN 3774-001.

Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 2 A to 25 A, switching capacity 65 /n - Part 004: UNC thread terminals - Product standard

General Information

Status
Withdrawn
Publication Date
22-Jun-1999
Withdrawal Date
20-Jan-2026
Technical Committee
ASD-STAN - Aerospace
Drafting Committee
ASD-STAN/D 2 - Electrical
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
30-Jun-2017
Completion Date
21-Jan-2026

Relations

Effective Date
06-Aug-2014
Standard

EN 3774-004:2002 - je enak SIST EN 3774-4:2001

English language
6 pages
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

National Aerospace and Defense Contractors Accreditation Program (NADCAP)

Global cooperative program for special process quality in aerospace.

ANAB United States Verified

NSF-ISR

NSF International Strategic Registrations.

ANAB United States Verified

Orion Registrar Inc.

US-based certification body for management systems.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN 3774-004:1999 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 2 A to 25 A, switching capacity 65 /n - Part 004: UNC thread terminals - Product standard". This standard covers: This standard specifies the required characteristics for three-pole, temperature compensated circuit breakers, rated currents from 2 A to 25 A, switching capacity 65 In, UNC thread terminals, for use in aircraft electrical systems. Their oprating temperatures are between -55°C and 125°C for rated currents equal or lower than 15 A and between -55°C and 90°C for rated currents higher than 15 A, at amaximum altitude of Z = 22 000 m. It shall be used together with EN 3774-001. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.

This standard specifies the required characteristics for three-pole, temperature compensated circuit breakers, rated currents from 2 A to 25 A, switching capacity 65 In, UNC thread terminals, for use in aircraft electrical systems. Their oprating temperatures are between -55°C and 125°C for rated currents equal or lower than 15 A and between -55°C and 90°C for rated currents higher than 15 A, at amaximum altitude of Z = 22 000 m. It shall be used together with EN 3774-001. These circuit breakers are intended for use in aircraft with electrical supplies in accordance with EN 2282.

EN 3774-004:1999 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 3774-004:1999 has the following relationships with other standards: It is inter standard links to EN 3774-004:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 3774-004:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 2 A to 25 A, switching capacity 65 /n - Part 004: UNC thread terminals - Product standardLuft- und Raumfahrt - Schutzschalter, dreipolig, temperaturkompensiert, Nennströme von 2 A bis 25 A, Schaltvermögen 65 /n - Teil 004: UNC-Klemmengewinde - ProduktnormSérie aérospatiale - Disjoncteurs tripolaires compensés en température, intensités nominales 2 A a 25 A, pouvoir de coupure 65 /n -
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...