prEN ISO 17632
(Main)Welding consumables - Tubular cored electrodes for gas shielded and non-gas shielded metal arc welding of non-alloy and fine grain steels - Classification (ISO/DIS 17632:2026)
- Abstract
ISO 17632:2015 specifies requirements for classification of tubular cored electrodes with or without a gas shield for metal arc welding of non-alloy and fine grain steels in the as-welded condition or in the post-weld heat-treated condition with a minimum yield strength of up to 500 MPa or a minimum tensile strength of up to 570 MPa. One tubular cored electrode can be tested and classified with different shielding gases, if any.
This International Standard is a combined specification providing classification utilizing a system based upon the yield strength and the average impact energy of 47 J of all-weld metal or utilizing a system based upon the tensile strength and the average impact energy of 27 J of all-weld metal.
1) Paragraphs and tables which carry the suffix letter "A" are applicable only to tubular cored electrodes classified to the system based upon the yield strength and the average impact energy of 47 J of all-weld metal in accordance with this International Standard.
2) Paragraphs and tables which carry the suffix letter "B" are applicable only to tubular cored electrodes classified to the system based upon the tensile strength and the average impact energy of 27 J of all-weld metal in accordance with this International Standard.
3) Paragraphs and tables which have neither the suffix letter "A" nor the suffix letter "B" are applicable to all tubular cored electrodes classified in accordance with this International Standard.
It is recognized that the operating characteristics of tubular cored electrodes can be modified by the use of pulsed current, but for the purposes of this International Standard, pulsed current is not permitted for determining the electrode classification.
- Status
- Not Published
- Publication Date
- 09-Apr-2028
- Technical Committee
- CEN/TC 121 - Welding and allied processes
- Drafting Committee
- CEN/TC 121/WG 3 - Welding consumables
- Current Stage
- 4020 - Submission to enquiry - Enquiry
- Start Date
- 22-Oct-2026
- Due Date
- 22-Oct-2026
- Completion Date
- 22-Oct-2026
prEN ISO 17632 is the CEN draft aligned with ISO/DIS 17632:2026, published under the title Welding consumables - Tubular cored electrodes for gas shielded and non-gas shielded metal arc welding of non-alloy and fine grain steels - Classification. It specifies how these tubular cored electrodes are classified for manufacturers, purchasers, welding engineers, and quality teams by strength, impact performance, chemical composition, shielding gas, welding position, hydrogen content, and post-weld heat treatment condition.
What does prEN ISO 17632 specify?
prEN ISO 17632 specifies classification requirements for tubular cored electrodes used for metal arc welding of non-alloy and fine grain steels in the as-welded condition or after post-weld heat treatment. The scope covers steels with a minimum yield strength up to 500 MPa or a minimum tensile strength up to 570 MPa.
The document uses two classification systems:
- System A - based on yield strength and 47 J average impact energy of all-weld metal.
- System B - based on tensile strength and 27 J average impact energy of all-weld metal.
A single electrode can be tested and classified with different shielding gases where applicable. Pulsed current is acknowledged as affecting operating characteristics, but it is not used to determine the classification.
| Annex | What it covers |
|---|---|
| Annex A | The two classification systems and how the designators fit together |
| Annex B | Types of electrode core used in System A |
| Annex C | Usability characteristics used in System B |
| Annex D | Notes on hydrogen content and its practical meaning |
What are the key requirements of prEN ISO 17632?
prEN ISO 17632 builds the designation from compulsory symbols, with optional symbols added where relevant. In practice, this is the code that appears on packages, product literature, and data sheets, so it is the main way to identify what an electrode is intended to do.
Classification and designation structure
The designation starts with T for tubular cored electrode. It then adds symbols for tensile properties, impact properties, chemical composition, core type or usability characteristics, shielding gas, welding position, hydrogen content, and, in System B, the post-weld heat treatment condition.
System A and System B do not use the same property symbols. That matters because the same commercial product can often be classified in both systems, but the designation language and supporting tables are different.
Strength and impact performance
For multi-run techniques, System A classifies by yield strength and elongation of all-weld metal, while System B classifies by tensile strength and elongation. For single-run techniques, the standard classifies the welded joint against the parent material used in the test.
Impact performance is tied to the classification system and the chosen test temperature. System A uses a 47 J requirement, while System B uses a 27 J requirement, with an optional supplemental designator for 47 J in System B. For the user, that means the designation tells you not only the strength level but also the toughness level the consumable has been tested to meet.
Test methods and specimen conditions
System A uses multi-run all-weld metal testing in the as-welded condition. System B can use the as-welded condition, the post-weld heat-treated condition, or both, depending on how the product is classified. For System B, the symbol A, P, or AP identifies the condition.
The standard also distinguishes between multi-run and single-run techniques. Products suitable for both single- and multi-run welding do not need the single-run test, which helps avoid unnecessary testing when the broader classification already applies.
Welding and heat-treatment conditions
For System A, no preheating is required and the interpass temperature is limited. For System B, preheating and interpass temperature are selected from the stated table for the relevant composition designation. If the classification includes post-weld heat treatment, the test assembly is heat treated under the specified furnace and holding conditions before testing.
These controls matter because classification is only valid when the test weld is made under the required thermal conditions. A welding team cannot assume a classification applies if the procedure used for testing was outside the stated limits.
Chemical composition, gas, position, and hydrogen
The standard classifies all-weld metal chemistry with separate tables for System A and System B. It also uses symbols for shielding gas in line with ISO 14175, except that NO is used for non-gas shielded tubular cored electrodes. Welding position is coded by the listed positions, and hydrogen content is identified with H5, H10, or H15.
This matters in procurement and procedure selection because the designation tells you whether the electrode has been classified for the position, shielding gas, and hydrogen level needed by the application. When hydrogen content is part of the designation, the manufacturer must state the handling and operating limits needed to stay within that hydrogen level.
Verification, rounding, and retesting
Mechanical tests are performed according to the referenced ISO test methods, and chemical analysis follows the stated pad or all-weld metal methods. Results are rounded using ISO 80000-1 rules, and retests are required if a test fails.
For a buyer or quality manager, that means the classification is not based on informal trial welding. It depends on defined test assemblies, accepted calculation rules, and repeat testing when results do not meet the specified requirement.
What changed in prEN ISO 17632 from the previous edition?
prEN ISO 17632 is described as the third edition and it cancels and replaces ISO 17632:2015. The foreword states that the document has been technically revised.
Which standards are used with prEN ISO 17632?
prEN ISO 17632 relies on several referenced standards that supply the test and purchasing framework around the classification:
- ISO 544 - technical delivery conditions, including product type, dimensions, tolerances, and markings.
- ISO 3690 - determination of hydrogen content in arc weld metal.
- ISO 6847 - deposition of a weld metal pad for chemical analysis.
- ISO 14175 - gas and gas mixtures for fusion welding and allied processes.
- ISO 14344 - procurement of filler materials and fluxes.
- ISO 15792-1:2020 - preparation of all-weld metal test pieces and specimens.
- ISO 15792-2:2020 - preparation of single-run and two-run technique test pieces and specimens.
- ISO 80000-1:2022 - quantities and units, including the rounding rule used for reported values.
- ISO 13916 - cited for measuring preheating and interpass temperature.
These references show that prEN ISO 17632 is not just a naming scheme. It connects classification to the actual test, measurement, and procurement methods used in welding practice.
What does the prEN ISO 17632 document contain?
prEN ISO 17632 contains 11 clauses, 4 informative annexes, a bibliography, and worked designation examples. Clause 4 sets out the two classification systems and the compulsory and optional sections of the designation.
Clause 5 gives the symbols for product type, strength, impact properties, chemical composition, core or usability type, shielding gas, welding position, hydrogen content, and post-weld heat treatment condition. Clause 6 describes the mechanical test assemblies, welding conditions, pass and layer sequences, interpass control, and PWHT conditions used to qualify the classification.
Clause 7 covers chemical analysis, Clause 8 gives the rounding procedure, and Clause 9 covers retests. Clause 10 links the document to delivery conditions, and Clause 11 shows designation examples for both systems. Annexes A to D explain the classification logic, the core types, the usability characteristics, and hydrogen-related notes that help users interpret the symbols in practice.
Relations
- Effective Date
- 23-Jul-2025
Get Certified
Connect with accredited certification bodies for this standard

DVS-ZERT GmbH
German welding certification society.
CARES (UK Certification Authority for Reinforcing Steels)
UK certification for reinforcing steels and construction.

EWF/IIW (European/International Welding Federation)
International welding personnel certification.
Sponsored listings
Frequently Asked Questions
prEN ISO 17632 is a draft published by the European Committee for Standardization (CEN). Its full title is "Welding consumables - Tubular cored electrodes for gas shielded and non-gas shielded metal arc welding of non-alloy and fine grain steels - Classification (ISO/DIS 17632:2026)". This standard covers: ISO 17632:2015 specifies requirements for classification of tubular cored electrodes with or without a gas shield for metal arc welding of non-alloy and fine grain steels in the as-welded condition or in the post-weld heat-treated condition with a minimum yield strength of up to 500 MPa or a minimum tensile strength of up to 570 MPa. One tubular cored electrode can be tested and classified with different shielding gases, if any. This International Standard is a combined specification providing classification utilizing a system based upon the yield strength and the average impact energy of 47 J of all-weld metal or utilizing a system based upon the tensile strength and the average impact energy of 27 J of all-weld metal. 1) Paragraphs and tables which carry the suffix letter "A" are applicable only to tubular cored electrodes classified to the system based upon the yield strength and the average impact energy of 47 J of all-weld metal in accordance with this International Standard. 2) Paragraphs and tables which carry the suffix letter "B" are applicable only to tubular cored electrodes classified to the system based upon the tensile strength and the average impact energy of 27 J of all-weld metal in accordance with this International Standard. 3) Paragraphs and tables which have neither the suffix letter "A" nor the suffix letter "B" are applicable to all tubular cored electrodes classified in accordance with this International Standard. It is recognized that the operating characteristics of tubular cored electrodes can be modified by the use of pulsed current, but for the purposes of this International Standard, pulsed current is not permitted for determining the electrode classification.
ISO 17632:2015 specifies requirements for classification of tubular cored electrodes with or without a gas shield for metal arc welding of non-alloy and fine grain steels in the as-welded condition or in the post-weld heat-treated condition with a minimum yield strength of up to 500 MPa or a minimum tensile strength of up to 570 MPa. One tubular cored electrode can be tested and classified with different shielding gases, if any. This International Standard is a combined specification providing classification utilizing a system based upon the yield strength and the average impact energy of 47 J of all-weld metal or utilizing a system based upon the tensile strength and the average impact energy of 27 J of all-weld metal. 1) Paragraphs and tables which carry the suffix letter "A" are applicable only to tubular cored electrodes classified to the system based upon the yield strength and the average impact energy of 47 J of all-weld metal in accordance with this International Standard. 2) Paragraphs and tables which carry the suffix letter "B" are applicable only to tubular cored electrodes classified to the system based upon the tensile strength and the average impact energy of 27 J of all-weld metal in accordance with this International Standard. 3) Paragraphs and tables which have neither the suffix letter "A" nor the suffix letter "B" are applicable to all tubular cored electrodes classified in accordance with this International Standard. It is recognized that the operating characteristics of tubular cored electrodes can be modified by the use of pulsed current, but for the purposes of this International Standard, pulsed current is not permitted for determining the electrode classification.
prEN ISO 17632 is classified under the following ICS (International Classification for Standards) categories: 25.160.20 - Welding consumables. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN ISO 17632 has the following relationships with other standards: It is inter standard links to EN ISO 17632:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN ISO 17632 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Classification
- 4.1 General
- 4.2 Classification systems
- 4.3 Compulsory and optional sections
- 5 Symbols and requirements
- 5.1 Symbol for the product/process
- 5.2 Symbol for tensile properties of all-weld metal or welded joint
- 5.3 Symbol for impact properties of all-weld metal or welded joint
- 5.4 Symbol for chemical composition of all-weld metal
- 5.5 Symbol for type of electrode core or for the usability characteristics of the electrode
- 5.6 Symbol for shielding gas
- 5.7 Symbol for welding position
- 1 PA, PB, PC, PD, PE, PF, PG
- 0 PA, PB
- 2 PA, PB, PC, PD, PE, PF
- 3 PA, PB
- 5 PA, PB, PG
- 5.8 Symbol for hydrogen content of deposited metal
- 5.9 Symbol for condition of postweld heat treatment of all-weld metal
- 6 Mechanical tests
- 6.1 Multi-run technique
- 6.2 Single-run technique
- 7 Chemical analysis
- 8 Rounding procedure
- 9 Retests
- 10 Technical delivery conditions
- 11 Examples of designation
- 11.1 General
- 11.2 Example 1 – System A
- 11.3 Example 2 – System B
- 11.4 Example 3 - System A
- 11.5 Example 4 – System B
- 11.6 Example 5 – System A
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
Introduction
This document provides a classification system for tubular cored electrodes in terms of tensile properties, impact properties, chemical composition of the all-weld metal, type of electrode core, shielding gas, and welding position. The ratio of yield to tensile strength of weld metal is generally higher than that of the parent metal. Matching weld metal yield strength to parent metal yield strength will not necessarily ensure that the weld metal tensile strength matches that of the parent metal. Where the application demands matching tensile strengths, selection of consumables is made by reference to Table 3, column 3 or 7, Tensile strength or Table 4, column 3 or 5, Minimum tensile strengths. Of note is that the mechanical properties of all-weld metal test specimens used to classify the tubular cored electrodes will vary from those obtained in production joints because of the differences in welding procedure such as electrode size, width of weave, welding position, and parent metal composition. The classification in accordance with System A is mainly based on EN 758:1997. The classification in accordance with System B is mainly based upon standards used around the Pacific Rim.
oSIST prEN ISO 17632:2026 DRAFT International Standard ISO/DIS 17632:2026(en) Welding consumables — Tubular cored electrodes for gas shielded and non-gas shielded metal arc welding of non-alloy and fine grain steels — Classification
1 Scope
This document specifies requirements for classification of tubular cored electrodes with or without a gas shield for metal arc welding of non-alloy and fine grain steels in the as-welded condition or in the post-weld heat-treated condition with a minimum yield strength of up to 500 MPa or a minimum tensile strength of up to 570 MPa. One tubular cored electrode can be tested and classified with different shielding gases, if any. This document is a combined specification providing classification utilizing a system based upon the yield strength and the average impact energy of 47 J of all-weld metal or utilizing a system based upon the tensile strength and the average impact energy of 27 J of all-weld metal. a) Clauses, subclauses and tables which carry the suffix “System A” are applicable only to tubular cored electrodes classified to the system based upon the yield strength and the average impact energy of 47 J of all-weld metal in accordance with this document.
b) Clauses, subclauses and tables which carry the suffix “System B” are applicable only to tubular cored electrodes classified to the system based upon the tensile strength and the average impact energy of 27 J of all-weld metal in accordance with this document.
c) Clauses, subclauses and tables which have neither the suffix "System A” nor the suffix "System B” are applicable to all tubular cored electrodes classified in accordance with this document. It is recognized that the operating characteristics of tubular cored electrodes can be modified by the use of pulsed current, but for the purposes of this document Standard, pulsed current is not to be used for determining the electrode classification.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 544, Welding consumables — Technical delivery conditions for filler materials and fluxes — Type of product, dimensions, tolerances and markings ISO 3690, Welding and allied processes — Determination of hydrogen content in arc weld metal ISO 6847, Welding consumables — Deposition of a weld metal pad for chemical analysis ISO 14175, Welding consumables — Gases and gas mixtures for fusion welding and allied processes ISO 14344, Welding consumables — Procurement of filler materials and fluxes ISO 15792-1:2020, Welding consumables — Test methods — Part 1: Preparation of all-weld metal test pieces and specimens in steel, nickel and nickel alloys ISO 15792-2:2020, Welding consumables — Test methods — Part 2: Preparation of single-run and two-run technique test pieces and specimens in steel ISO 80000-1:2022, Quantities and units — Part 1: General
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
4 Classification
4.1 General
Classification designations are based upon two approaches, A and B, to indicate the tensile properties and the impact properties of the all-weld metal obtained with a given electrode. System A is applicable to tubular cored electrodes classified under the system based on the yield strength and an average impact energy of 47 J of the all-weld metal given in this document. System B is applicable to tubular cored electrodes classified under the system based on the tensile strength and an average impact energy of 27 J of the all-weld metal given in this document. The two designation approaches include additional designators for some other classification requirements, but not all as will be clear from the following. In most cases, a given commercial product can be classified in both systems. Then, either or both classification designations can be used for the product (see Annex A). The classification includes all-weld metal properties obtained with a tubular cored electrode and appropriate shielding gas combination as given below. The classification of gas shielded tubular cored electrodes is based on the 1,2 mm electrode size or if this size is not manufactured, the next larger diameter manufactured. The classification of self-shielded tubular cored electrodes is based on the 2,4 mm diameter or the largest diameter manufactured if less than 2,4 mm.
4.2 Classification systems
Each classification system, A and B, is split into parts as given in Table 1. Table 1 — Classification systems Part of Classification system classification System A System B designation 1 Symbol T indicates a tubular cored electrode.
Symbol indicating the yield strength and elongation Symbol indicating the tensile strength and elonof all-weld metal for multi-run technique or the gation of all-weld metal for multi-run technique 2 strength of the parent material used in classification or the strength of the parent material used in for the single-run technique (see Table 3 or Table 4). classification for the single-run technique (see Table 3 or Table 4).
Symbol indicating the impact properties of all-weld Symbol indicating the impact properties of allmetal or welded joint (see Table 5). weld metal (see Table 5). The symbol “U” added as an optional supplemental designator at or near 3 the end of the complete tubular cored electrode designation indicates that the deposit meets an average optional requirement of 47 J at the designated Charpy test temperature. Symbol indicating the chemical composition of Symbol indicating the usability characteristics of
all-weld metal (see Table 6). the electrode (see Table 9).
Symbol indicating the type of electrode core (see Symbol indicating the welding position (see Table 9).
Table 8).
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en) TTabablele 1 1 ((ccoonnttiinnueuedd)) Part of Classification system classification System A System B designation Symbol indicating the shielding gas (see 5.6). Symbol indicating the shielding gas (see 5.6). The 6 letter “S” added to this designator indicates that the electrode is classified for single-pass welding.
Symbol indicating the welding position (see Symbol indicating whether the classification tests Table 10); were conducted in the as-welded (A) or post-weld heat-treated condition (P). If the electrode has been classified in both conditions, the symbol AP
shall be added to the classification. This designator is omitted in the classification for single-pass welding electrodes as these are tested only in the as-welded condition.
Symbol indicating the hydrogen content of depos- Symbol indicating the chemical composition of allited metal (see Table 11). weld metal (see Table 7). The symbol is omitted
for weld deposits conforming to the “No symbol” in Table 7.
Symbol indicating the hydrogen content of deposited metal (see Table 11).
Electrodes can be classified under any number of classifications for either or both the as-welded and post-weld heat-treated condition.
For both Systems A and B, the electrode classification shall include all compulsory sections and can include optional sections as outlined in 4.3.
4.3 Compulsory and optional sections
The compulsory and optional sections are given in Table 2.
The full designation shall comprise the compulsory symbols and can include optional symbols chosen by the manufacturer. The full designation (see Clause 10) shall be used on packages and in the manufacturer’s literature and data sheets.
Table 2 — Compulsory and optional sections Classification system Section System A System B includes the symbols for type of product, strength includes the symbols for type of product, strength and elongation, impact properties, chemical compo- and elongation in the as-welded condition or postsition, type of electrode core, and shielding gas, i.e. weld heat-treated condition, welding positions for Compulsory the symbols defined in 5.1, 5.2, 5.3, 5.4, 5.5, and 5.6. which the electrode is suitable, usability characteristics, shielding gas, impact properties, and chemical composition, i.e. the symbols defined in 5.1, 5.2, 5.3, 5.4, 5.5, 5.6, 5.7, and 5.9.
includes the symbols for the welding positions for includes the symbol “U” to indicate that the weld which the electrode is suitable and the symbol for metal has an average of 47 J impact energy at the Optional hydrogen content, i.e. the symbols defined in 5.7 classification test temperature and the symbol and 5.8. for hydrogen content, i.e. the symbol “U” defined in 5.2 and the symbols defined in 5.8.
5 Symbols and requirements
5.1 Symbol for the product/process
The symbol for the tubular cored electrode used in the metal arc welding process is the letter T.
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
5.2 Symbol for tensile properties of all-weld metal or welded joint
5.2.1 Multi-run technique
The symbols in Table 3 indicate:
a) System A – for products suitable for single- and multi-run welding, the symbol in Table 3 indicates yield strength, tensile strength, and elongation of the all-weld metal in the as-welded condition determined in accordance with 6.1.
b) System B – for electrodes suitable for single- and multi-run welding, the symbol in Table 3 indicates yield strength, tensile strength, and elongation of the all-weld metal in the as-welded condition or in the post-weld heat-treated condition determined in accordance with 6.1. Classification of products suitable for both single- and multi-run welding does not require the single-run test of 6.2.
Table 3 — Symbols for tensile properties – multi-run technique System A System B Minimum yield Tensile Minimum Minimum yield Tensile Minimum a b a b strength strength elongation strength strength elongation Symbol Symbol MPa MPa % MPa MPa % 35 355 440 to 570 22 43 330 430 to 600 20 38 380 470 to 600 20 49 390 490 to 670 18 42 420 500 to 640 20 55 460 550 to 740 17 46 460 530 to 680 20 57 490 570 to 770 17 50 500 560 to 720 18 a For yield strength, the lower yield, R , is used when yielding occurs. Otherwise, the 0,2 % proof strength, R , is used. eL p0,2 b Gauge length is equal to five times the test specimen diameter.
5.2.2 Single-run technique
For tubular cored electrodes suitable for single-run welding only, the symbols in Table 4 indicate the strength of the welded joint in the as-welded condition in relation to the parent material used in single-run tests satisfactorily completed in accordance with 6.2.
Table 4 — Symbol for tensile properties by single-run technique System A System B Minimum parent Minimum tensile Minimum tensile strength of the material yield strength of the parent metal and of the welded joint Symbol Symbol strength welded joint MPa MPa MPa 3T 355 470 43 430 4T 420 520 49 490 55 550 5T 500 600 57 570
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
5.3 Symbol for impact properties of all-weld metal or welded joint
The symbols in Table 5 indicate the temperature at which a minimum average impact energy of 47 J or 27 J is achieved. The testing conditions for System A and System B are:
a) System A: the conditions given in 6.1 or 6.2 shall be followed. Three test specimens shall be tested. Only one individual value can be lower than 47 J, but not lower than 32 J.
b) System B: testing can be in the as-welded condition or in the post-weld heat-treated condition under the conditions given in 6.1 or 6.2.
Five test specimens shall be tested. The lowest and highest values obtained shall be disregarded. Two of the three remaining values shall be greater than or equal to the specified 27 J level. One of the three can be lower, but shall be no less than 20 J. The average of the three remaining values shall be at least 27 J. Three test specimens shall be tested when the optional supplemental designator “ (see” is used to indicate that the weld deposit will meet a minimum impact energy of 47 J at the test temperature. The impact value shall be determined by the average of the three test specimens. The average of three values shall be 47 J or greater. Only one individual value can be lower than 47 J, but not lower than 32 J. When an all-weld metal has been classified for a certain temperature, it automatically covers any higher temperature listed in Table 5.
NOTE Impact testing is not required to classify electrodes for the single-run technique. Table 5 — Symbol for impact properties of all-weld metal or welded joint a,b c Temperature for minimum average impact energy of 47 J or 27 J Symbol °C a Z No requirements b c A or Y +20 0 0 2 −20 3 −30 4 −40 5 −50 6 −60 7 −70 8 −80 9 −90 10 −100 a Only the symbol Z is used for electrodes for the single-run technique. b Classification by yield strength and 47 J impact energy.
Classification by tensile strength and 27 J impact energy.
5.4 Symbol for chemical composition of all-weld metal
The symbols in Table 6 for System A and Table 7 for System B indicate the chemical composition of all-weld metal determined in accordance with Clause 7.
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
Table 6 — System A symbols for chemical composition of all-weld metal a, b Chemical composition (percentage mass fraction) Composition
designation C Mn Si P S Cr Ni Mo V Nb Al Cu No symbol — 2,0 — — — 0,2 0,5 0,2 0,08 0,05 2,0 0,3 Mo — 1,4 — — — 0,2 0,5 0,3 to 0,6 0,08 0,05 2,0 0,3 MnMo — 1,4 to 2,0 — — — 0,2 0,5 0,3 to 0,6 0,08 0,05 2,0 0,3 1Ni — 1,4 0,80 — — 0,2 0,6 to 1,2 0,2 0,08 0,05 2,0 0,3 1,5Ni — 1,6 — — — 0,2 1,2 to 1,8 0,2 0,08 0,05 2,0 0,3 2Ni — 1,4 — — — 0,2 1,8 to 2,6 0,2 0,08 0,05 2,0 0,3 3Ni — 1,4 — — — 0,2 2,6 to 3,8 0,2 0,08 0,05 2,0 0,3 Mn1Ni — 1,4 to 2,0 — — — 0,2 0,6 to 1,2 0,2 0,08 0,05 2,0 0,3 1NiMo — 1,4 — — — 0,2 0,6 to 1,2 0,3 to 0,6 0,08 0,05 2,0 0,3 d Z Any other agreed composition a Single values are maximum values.
b Analysis for boron is required if intentionally added.
Self-shielded electrodes only.
d Consumables for which the chemical composition is not listed shall be symbolized similarly and prefixed by the letter Z. The chemical composition ranges are not specified and therefore it is possible that two electrodes with the same Z classification are not interchangeable.
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
Table 7 — System B symbols for chemical composition of all-weld metal a,b Chemical composition (percentage mass fraction) Composition
designation C Mn Si P S Cr Ni Mo Cu V Al d e e e e No symbol 0,18 2,00 0,90 0,030 0,030 0,20 0,50 0,30 — 0,08 2,0 e e e e K 0,20 1,60 1,00 0,030 0,030 0,20 0,50 0,30 — 0,08 — 2M3 0,12 1,50 0,80 0,030 0,030 — — 0,40 to 0,65 — — 1,8 3M2 0,15 1,25 to 2,00 0,80 0,030 0,030 — — 0,25 to 0,55 — — 1,8 N1 0,12 1,75 0,80 0,030 0,030 — 0,30 to 1,00 0,35 — — 1,8 N2 0,12 1,75 0,80 0,030 0,030 — 0,80 to 1,20 0,35 — — 1,8 N3 0,12 1,75 0,80 0,030 0,030 — 1,00 to 2,00 0,35 — — 1,8 N5 0,12 1,75 0,80 0,030 0,030 — 1,75 to 2,75 — — — 1,8 N7 0,12 1,75 0,80 0,030 0,030 — 2,75 to 3,75 — — — 1,8 CC 0,12 0,60 to 1,40 0,20 to 0,80 0,030 0,030 0,30 to 0,60 — — 0,20 to 0,50 — 1,8 NCC 0,12 0,60 to 1,40 0,20 to 0,80 0,030 0,030 0,45 to 0,75 0,10 to 0,45 — 0,30 to 0,75 — 1,8 NCC1 0,12 0,50 to 1,30 0,20 to 0,80 0,030 0,030 0,45 to 0,75 0,30 to 0,80 — 0,30 to 0,75 — 1,8 N1M2 0,15 2,00 0,80 0,030 0,030 0,20 0,40 to 1,00 0,20 to 0,65 — 0,05 1,8 N2M2 0,15 2,00 0,80 0,030 0,030 0,20 0,80 to 1,20 0,20 to 0,65 — 0,05 1,8 N3M2 0,15 2,00 0,80 0,030 0,030 0,20 1,00 to 2,00 0,20 to 0,65 — 0,05 1,8 f G Any other agreed composition a Single values s are maximum values.
b Analysis for boron is required if intentionally added.
Self-shielded electrodes only.
d 0,30 % for self-shielded electrodes.
e The analysis of these elements shall be reported only if added intentionally. f Consumables for which the chemical composition is not listed shall be symbolized by the letter G. The chemical composition ranges are not specified and therefore it is possible that two electrodes with the same G classification are not interchangeable.
oSIST prEN ISO 17632:2026 ISO/DIS 17632:2026(en)
...