General Information

Abstract

This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100.
The primary aim of this test is:
- to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and
- to examine the aptitude of the insulation to track, to propagate electric arc  to the electrical origin.
Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.

Status
Withdrawn
Publication Date
22-Nov-2011
Withdrawal Date
16-Sep-2026
Technical Committee
ASD-STAN - Aerospace
Drafting Committee
ASD-STAN/D 2 - Electrical
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
10-Jan-2018
Completion Date
17-Sep-2026

Buy Documents

Corrigendum

EN 3475-603:2011/AC:2012

English language (2 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
31-Jan-2018
Effective Date
08-Jun-2022

Buy Documents

Corrigendum

EN 3475-603:2011/AC:2012

English language (2 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany

Bureau Veritas certification in Germany.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

AQMS Ltd.

AQMS provides ISO certification to SMEs across the UK.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 3475-603:2011/AC:2011 is a corrigendum published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking". This standard covers: This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and - to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.

This European Standard specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This standard should be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects, which are representative of those, which may occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; and - to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin. Originally defined for 115 Vac network, this test also proposes conditions for 230 Vac network. Unless otherwise specified in product standard, only 115 Vac conditions shall be satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 7). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard sizes 002, 006 and 020 cable should be assessed.

EN 3475-603:2011/AC:2011 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 3475-603:2011/AC:2011 has the following relationships with other standards: It is inter standard links to EN 3475-603:2018, EN 3475-603:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 3475-603:2011/AC:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 603: Lichtbogenfestigkeit, feuchtSérie aérospatiale - Câbles électriques à usage aéronautique - Méthodes d' essais - Partie 603: Résistance à l'amorcage et à la propagation d'arc èlectrique, essai humideAerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-603:2011/AC:2011SIST EN 3475-603:2011/AC:2012en01-februar-2012SIST EN 3475-603:2011/AC:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 3475-603:2011/AC
November 2011
Novembre 2011
November 2011 ICS 49.060 English version Version Française Deutsche Fassung
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking
Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d' essais - Partie 603: Résistance à l'amorcage et à la propagation
...