Child care articles - Bath tubs, stands and non-standalone bathing aids - Safety requirements and test methods

This document specifies safety requirements and test methods for children’s bath tubs and stands and for non-standalone bathing aids that are designed and intended to be used only in conjunction with a children’s bath tub.
This document does not cover children’s bath tubs and stands and non-standalone bathing aids designed for children with special needs.
NOTE 1   Standalone bathing aids are covered in EN 17022.
NOTE 2   Where the product has several functions or can be converted into another function it is due to comply with relevant standard(s).

Artikel für Säuglinge und Kleinkinder - Badewannen, Gestelle und nicht freistehende Badehilfen - Sicherheitsanforderungen und Prüfverfahren

Dieses Dokument legt sicherheitstechnische Anforderungen und Prüfverfahren für Kinderbadewannen und Gestelle sowie für nicht freistehende Badehilfen fest, die ausschließlich für die Verwendung in Kombination mit Kinderbadewannen ausgelegt und bestimmt sind.
Diese Europäische Norm gilt nicht für Badewannen und Gestelle sowie nicht freistehende Badehilfen, die für Kinder mit besonderen Bedürfnissen konzipiert sind.
ANMERKUNG 1   Freistehende Badehilfen werden in FprEN 17022 behandelt.
ANMERKUNG 2   Wenn das Produkt unterschiedliche Funktionen hat oder in eine andere Funktion umgewandelt werden kann, muss es mit der (den) entsprechenden Norm(en) übereinstimmen.

Articles de puériculture - Baignoires, supports et aides au bain non indépendantes - Exigences de sécurité et méthodes d’essai

Le présent document spécifie les exigences de sécurité et les méthodes d’essai relatives aux baignoires pour enfant et à leurs supports, et aux aides au bain non indépendantes conçues et destinées à être utilisées uniquement en conjonction avec une baignoire pour enfant.
Le présent document ne couvre pas les baignoires pour enfant et leurs supports et les aides au bain non indépendantes destinées aux enfants ayant des besoins particuliers.
NOTE 1   Les aides au bain non intégrées sont couvertes par l'EN 17022.
NOTE 2   Quand le produit possède plusieurs fonctions ou peut être converti en une autre fonction, la ou les normes applicables doivent être respectées.

Izdelki za otroke - Kopalne kadi, podstavki in nesamostoječi kopalni pripomočki - Varnostne zahteve in preskusne metode

Ta evropski standard določa varnostne zahteve in preskusne metode za otroške kopalne kadi in podstavke ter za nesamostoječe kopalne pripomočke, ki so namenjeni za uporabo v povezavi z otroško kadjo. Ta evropski standard ne zajema kopalnih kadi in kopalnih podstavkov, namenjenih otrokom s posebnimi potrebami. OPOMBA: Če ima izdelek več funkcij ali je mogoče njegovo funkcijo spremeniti, zanjo veljajo zadevni evropski standardi.

General Information

Status
Published
Publication Date
18-Dec-2018
Withdrawal Date
29-Jun-2019
Current Stage
9092 - Decision on results of review/2YR ENQ - revise - Review Enquiry
Start Date
26-Aug-2024
Completion Date
14-Apr-2025
Standard
EN 17072:2019 - BARVE
English language
46 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Artikel für Säuglinge und Kleinkinder - Badewannen und Gestelle - Sicherheitsanforderungen und PrüfverfahrenArticles de puériculture - Baignoires et supports - Exigences de sécurité et méthodes d'essaiChild care articles - Bath tubs, stands and non-standalone bathing aids - Safety requirements and test methods97.190Otroška opremaEquipment for childrenICS:Ta slovenski standard je istoveten z:EN 17072:2018SIST EN 17072:2019en,fr,de01-april-2019SIST EN 17072:2019SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 17072
December
t r s z ICS
{ yä s { r English Version
Child care articles æ Bath tubsá stands and nonæstandalone bathing aids æ Safety requirements and test methods Articles de puériculture æ Baignoiresá supports et aides au bain non indépendantes æ Exigences de sécurité et méthodes d 5essai
Artikel für Säuglinge und Kleinkinder æ Badewannená Gestelle und nicht freistehende Badehilfen æ Sicherheitsanforderungen und Prüfverfahren This European Standard was approved by CEN on
s { October
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s y r y tã t r s z ESIST EN 17072:2019

Rationales . 36 A.1 General . 36 A.2 Chemical hazards (see Clause 6) . 36 A.3 Mechanical hazards (see Clause 7) . 36 A.3.1 General . 36 A.3.2 Entrapment hazards . 36 A.3.3 Hazards due to moving parts . 36 A.3.4 Entanglement hazards . 37 A.3.5 Choking and ingestion hazards . 37 A.3.6 Suffocation hazards. 37 A.3.7 Hazardous edges, corners and protruding parts . 37 A.3.8 Hazards from inadequate structural integrity . 37 A.3.9 Hazards due to folding or adjusting of the product . 37 A.3.10 Plastic decals . 38 A.3.11 Hazards due to inadequate stability . 38 A.4 Drowning hazard . 38 A.5 Thermal hazards . 38 Annex B (normative)
Warnings . 39 Bibliography . 46 SIST EN 17072:2019

Key A non-standalone bathing aid B child’s bath tub Figure 1 — Example of non-standalone bathing aids 3.3.1 non-standalone bath cradle non standalone bathing aid designed to keep a child in a reclined position during bathing Note 1 to entry: These products are intended for use from birth and until the child is able to sit upright unassisted. 3.3.2 non-standalone bath seat non-standalone bathing aid designed to keep a child in a seated position during bathing Note 1 to entry: These products are intended for use with a child who is able to sit upright unassisted and until the child begins pulling up to a standing position. 3.4 integrated bath cradle non-removable part of a children’s bath tub designed to keep a child in a reclined position during bathing. See Figure 2. Note 1 to entry: These products are intended for use from birth and until the child is able to sit upright unassisted. SIST EN 17072:2019

Figure 2 — Example of integrated bath cradle 4 Test equipment 4.1 Test probes for finger entrapment 4.1.1 Test probes with hemispherical end Probes made from plastic or other hard, smooth material of diameters ()−0017, mm and ()+01012, mm with a full hemispherical end that can be mounted on a force-measuring device, see Figure 3. Mesh probe made from plastic or other hard, smooth material as shown in Figure 4. Dimensions in millimetres
Key Probe type 7 mm probe 12 mm probe Diameter A 0-017, +01012, Radius RB half of diameter A half of diameter A 1 Line scribed around circumference showing depth of penetration Figure 3 — Test probes with hemispherical end SIST EN 17072:2019

Key Probe type mesh probe Diameter A −0017, Diameter B −00156,, Radius RB half of diameter B Figure 4 — Test probe for mesh 4.1.2 Shape assessment probe Probe made from plastics or other hard, smooth material with the dimensions shown in Figure 5. Dimensions in millimetres
Key A front view B top view C side view D 3D view Figure 5 — Shape assessment probe 4.2 Test probes for head entrapment 4.2.1 Small head probe Probe made of hard and smooth material with dimensions as shown in Figure 6. SIST EN 17072:2019

Key 1 handle Figure 6 — Small head probe 4.2.2 Large head probe Probe made of hard and smooth material with dimensions as shown in Figure 7. Dimensions in millimetres
Key 1 handle Figure 7 — Large head probe 4.2.3 Template for partially bound and V shaped openings Probe made of hard and smooth material with dimensions as shown in Figure 8. SIST EN 17072:2019

a) b) Key 1 B portion 2 A portion a) front view b) side view Figure 8 — Template for partially bound and V shaped openings 4.3 Test mass A A rigid cylinder (160 ± 5) mm in diameter and (300 ± 5) mm in height, having a mass of 9 kg and with its centre of gravity in the centre of the cylinder. All edges shall have a radius of (5 ± 1) mm. Two anchorage points shall be provided. These shall be positioned (150 ± 2,5) mm from the base and at 180° to each other around the circumference (see Figure 9). SIST EN 17072:2019

Key 1 radius: (5 ± 1) mm 2 two anchorage points Figure 9 — Test mass A 4.4 Small parts cylinder Small parts cylinder for the assessment of small components, having dimensions in accordance with Figure 10. SIST EN 17072:2019

Figure 10 — Small parts cylinder 4.5 Feeler gauge Gauge with a thickness of (0,4 ± 0,02) mm and an insertion edge radius of (3 ± 0,5) mm (Figure 11). Dimensions in millimetres
Figure 11 — Feeler gauge 4.6 Test glass surface A rigid plane covered with uncoated tempered float glass that has a smooth surface and thickness of 6 mm. 4.7 Test surface for drop test and impact test A 2 mm thick rubber mat, with hardness (75 ± 10) Shore A according to ISO 7619-1, and which is placed on a horizontal concrete surface. 4.8 Tube Tube with an inner diameter of 60 mm. SIST EN 17072:2019

Key 1 inside 2 outside 3 bath mounted support 4 bath test base Figure 12 — Test base for bath mounted supports The profiles shall be fixed parallel to the distance equal to the minimum bath dimension recommended by the manufacturer of the bath mounted supports. 5 General requirements 5.1 Product conditioning Products containing vulcanized rubber and thermoplastic elastomer parts (but not silicone parts) shall be artificially aged for seven days in an aerated drying cabinet at a temperature of (70 ± 2) °C. All products shall be conditioned for at least 24 h, in a standard atmosphere (as specified in EN ISO 291) at a temperature of (23 ± 2) °C and relative humidity of (50 ± 5) %. SIST EN 17072:2019

mg/kg Aluminium
70 000 Antimony
560 Arsenic
47 Barium
18 750 Boron
15 000 Cadmium
17 Chromium (III)
460 SIST EN 17072:2019
0,2 Cobalt
130 Copper
7 700 Lead
23 Manganese
15 000 Mercury
94 Nickel
930 Selenium
460 Strontium
56 000 Tin
180 000 Organic tin
12 Zinc
46 000 When testing is performed the method specified in EN 71-3 shall be used. A separate sample may be used for these tests. 7 Mechanical hazards (see A.3) 7.1 General No harness shall be provided as a child restraint system. 7.2 Entrapment hazards 7.2.1 Entrapment of fingers 7.2.1.1 Requirement There shall be no accessible completely bounded openings in rigid materials, in the inner and upper surface that supports the child and on the exterior side of the bath tub up to 100 mm from the bath tub rim, between 7 mm and 12 mm unless the depth is less than 10 mm or unless the shape assessment probe, see 4.1.2, enters, when tested in accordance with 7.2.1.2. There shall be no accessible openings in mesh, in the inner and upper surface that supports the child and on the exterior side of the bath tub up to 100 mm from the bath tub rim, that allow the test probe for mesh, 4.1.1, to penetrate up to the 7 mm diameter section, when tested in accordance with 7.2.1.2. The test shall be carried out with the product in any intended position of use without any test mass and with test mass A (see 4.3). 7.2.1.2 Test method Check whether the 7 mm probe, 4.1.1, with an applied force of up to 30 N, enters 10 mm or more into any accessible completely bounded opening in any possible orientation. If the 7 mm probe enters 10 mm or more, then the 12 mm probe, 4.1.1, shall also enter 10 mm or more with an applied force of up to 5 N. If the 7 mm probe enters with an applied force of up to 30 N but the 12 mm probe does not enter 10 mm or more with an applied force of up to 5 N, check whether the 12 mm shape assessment probe (see 4.1.2) enters with an applied force of up to 5 N. Check whether the test probe for mesh, 4.1.1, with an applied force of up to 30 N, penetrates accessible openings in mesh up to the 7 mm diameter section. SIST EN 17072:2019

Key 1 PASS 2 PASS 3 continue with the test 4 continue with the test Figure 13 — Method of insertion of portion B
Key 1 PASS 2 continue with the test Figure 14 — Method of insertion of portion B SIST EN 17072:2019

Key 1 PASS 2 FAIL Figure 15 — Method of insertion of portion A 7.3 Hazards due to moving parts 7.3.1 Requirements for compression points After the product has been set up for use in accordance with the manufacturer’s instructions, there shall be no accessible compression points, in the inner and upper surface that supports the child and on the exterior side of the bath tub up to 100 mm from the bath tub rim, which can close to less than 12 mm unless they are always less than 5 mm, as the result of: a) the movement of the product; or b) the movement of body weight by the child using the product; or c) the application of an external force (either unintentionally by the carer, or by a powered mechanism). Movement due to elasticity of materials shall not be considered as compression hazard. SIST EN 17072:2019

Key D distance between attachment points L length of cords, ribbons and parts used as ties Figure 16 — Examples of measuring cords, ribbons or similar parts 7.4.2 Test method The length of a cord, ribbon or similar part is measured from the fixing point on the product to the free end of the cord, ribbon or similar part while a 25 N tensile force is applied. The peripheral dimension of a loop shall be measured while a 25 N tensile force is applied. 7.5 Choking and ingestion hazards 7.5.1 Requirements Any component or filling material, in the inner and upper surface that supports the child and on the exterior side of the bath tub up to 100 mm from the bath tub rim, that is considered able to be gripped by a child in accordance with 7.5.2.1 shall be tested in accordance with 7.5.2.2 and 7.5.2.3. Any component or part of a component or filling material that is removed shall not fit wholly in any orientation, without compressing or manipulating it, within the small parts cylinder specified in 4.4. Foam pads with a thickness lower than 2 mm are excluded from these requirements. 7.5.2 Test methods 7.5.2.1 Assessment of child’s ability to grip components A component is considered to be able to be gripped if the child can grip the component between its thumb and forefinger or between its teeth. SIST EN 17072:2019
...