EN 54-4:1997/AC:1999
(Corrigendum)Fire detection and fire alarm systems - Part 4: Power supply equipment
Fire detection and fire alarm systems - Part 4: Power supply equipment
TC - See historical background in the file
Brandmeldeanlagen - Teil 4: Energieversorgungseinrichtungen
Systèmes de détection et d'alarme incendie - Partie 4: Equipement d'alimentation électrique
Sistemi za odkrivanje in javljanje požara ter alarmiranje – 4. del: Oprema za napajanje
General Information
- Status
- Published
- Publication Date
- 24-Feb-1999
- Technical Committee
- CEN/TC 72 - Fire detection and fire alarm systems
- Drafting Committee
- CEN/TC 72 - Fire detection and fire alarm systems
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 25-Feb-1999
- Completion Date
- 25-Feb-1999
- Directive
- 89/106/EEC - Construction products
- Directive
- 96/98/EC - Marine equipment
Relations
- Effective Date
- 22-Dec-2008
Overview
EN 54-4:1997/AC:1999 is the European Committee for Standardization (CEN) standard for power supply equipment used in fire detection and fire alarm systems. It specifies requirements and expectations for the design, performance, fault signalling and reliability of power sources that feed fire detection and alarm installations. This standard was adopted nationally (e.g., SIST EN 54-4:1997/AC:2000 in Slovenia) and forms part of the wider EN 54 series for fire detection and alarm systems.
Key Topics
The standard focuses on technical and operational aspects of power supply equipment, including:
- Scope and applicability for power units used in fire alarm systems
- Design and construction expectations to ensure safe, durable power supply components
- Mains supply and backup power arrangements to maintain system operation during mains failure
- Battery/charging requirements and provisions for energy storage and charging (performance and reliability considerations)
- Fault monitoring and signalling to alert users and maintenance personnel of power faults or degraded supply
- Performance, testing and documentation requirements to verify reliability and to support installation, inspection and maintenance
- Installation and wiring considerations to ensure compatibility and safe integration with fire detection equipment
(Note: the above items reflect the typical scope for power-supply standards within the EN 54 family; see the official EN 54-4 document for exact clauses and technical specifications.)
Applications
EN 54-4 is intended for use where dependable power is critical to fire detection and alarm performance. Typical users and applications include:
- Manufacturers of power supply units, battery chargers and backup systems for fire alarm panels
- System designers and integrators specifying power architectures for building fire safety systems
- Installers and commissioning engineers ensuring correct installation and initial testing of alarm power supplies
- Maintenance and facilities teams conducting inspections, testing and remedial actions
- Certification and regulatory bodies assessing compliance with European fire safety requirements
- Buildings and facilities requiring certified fire detection systems: commercial complexes, hospitals, industrial plants, residential blocks and public infrastructure
Related Standards
- EN 54 series (other parts covering detectors, control panels, alarm devices)
- National adoptions (e.g., SIST EN 54-4) and relevant electrical installation standards
By following EN 54-4:1997/AC:1999, stakeholders can ensure reliable power design and operation for fire detection and alarm systems, improving overall fire safety and compliance with European standardization.
Frequently Asked Questions
EN 54-4:1997/AC:1999 is a amendment with corrigendum published by the European Committee for Standardization (CEN). Its full title is "Fire detection and fire alarm systems - Part 4: Power supply equipment". This standard covers: TC - See historical background in the file
TC - See historical background in the file
EN 54-4:1997/AC:1999 is classified under the following ICS (International Classification for Standards) categories: 13.220.20 - Fire protection. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 54-4:1997/AC:1999 has the following relationships with other standards: It is inter standard links to EN 54-4:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 54-4:1997/AC:1999 is associated with the following European legislation: EU Directives/Regulations: 2014/90/EU, 305/2011, 89/106/EEC, 96/98/EC; Standardization Mandates: M/109. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 54-4:1997/AC:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2000
Sistemi za odkrivanje in javljanje požara ter alarmiranje – 4. del: Oprema za
napajanje
Fire detection and fire alarm systems - Part 4: Power supply equipment
Brandmeldeanlagen - Teil 4: Energieversorgungseinrichtungen
Systemes de détection et d'alarme incendie - Partie 4: Equipement d'alimentation
électrique
Ta slovenski standard je istoveten z: EN 54-4:1997/AC:1999
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...