Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner

SIGNIFICANCE AND USE
4.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the rehabilitation of sewer service laterals and its connection to the main through the use of a resin-impregnated tube installed within an existing sewer lateral. As for any practice, modifications may be required for specific job conditions.
SCOPE
1.1 This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner diameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0 cm) and up the lateral a maximum of 150 ft without excavation. The lateral pipe is accessed remotely from the main pipe and from a lateral access point. This will be accomplished by the installation of a resin impregnated one-piece main and lateral cured-in-place lining (MLCIPL) by means of air inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe, providing a verifiable non-leaking structural connection and seal.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 There is no similar or equivalent ISO Standard.  
1.4 Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, may be prohibited by local or national law.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
30-Nov-2017
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F2561-17 - Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F2561-17 - Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F2561 − 17
Standard Practice for
Rehabilitation of a Sewer Service Lateral and Its Connection
to the Main Using a One Piece Main and Lateral Cured-in-
1,2
Place Liner
This standard is issued under the fixed designation F2561; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* containing products. See the applicable product Safety Data
Sheet (SDS) for additional information. Users should be aware
1.1 This practice covers requirements and test methods for
that selling mercury or mercury-containing products, or both,
the reconstruction of a sewer service lateral pipe having an
may be prohibited by local or national law.
innerdiameterof3to12in.(7.6to30.5cm)anditsconnection
1.5 This standard does not purport to address all of the
to the main pipe having an inner diameter of 6 to 24 in. (15.2
safety concerns, if any, associated with its use. It is the
to 61.0 cm) and up the lateral a maximum of 150 ft without
responsibility of the user of this standard to establish appro-
excavation.Thelateralpipeisaccessedremotelyfromthemain
priate safety, health, and environmental practices and deter-
pipe and from a lateral access point.This will be accomplished
mine the applicability of regulatory limitations prior to use.
by the installation of a resin impregnated one-piece main and
1.6 This international standard was developed in accor-
lateral cured-in-place lining (MLCIPL) by means of air infla-
dance with internationally recognized principles on standard-
tion and inversion. The MLCIPL is pressed against the host
ization established in the Decision on Principles for the
pipe by pressurizing a bladder and is held in place until the
Development of International Standards, Guides and Recom-
thermosetresinshavecured.Whencured,theMLCIPLshallbe
mendations issued by the World Trade Organization Technical
a continuous, one piece, tight fitting, corrosion resistant lining
Barriers to Trade (TBT) Committee.
extending over a predetermined length of the lateral pipe and
the adjacent section of the main pipe, providing a verifiable
2. Referenced Documents
non-leaking structural connection and seal.
3
2.1 ASTM Standards:
1.2 The values stated in inch-pound units are to be regarded
D618 Practice for Conditioning Plastics for Testing
as standard. The values given in parentheses are mathematical
D790 Test Methods for Flexural Properties of Unreinforced
conversions to SI units that are provided for information only
and Reinforced Plastics and Electrical Insulating Materi-
and are not considered standard.
als
1.3 There is no similar or equivalent ISO Standard.
D1600 TerminologyforAbbreviatedTermsRelatingtoPlas-
1.4 Warning—Mercury has been designated by many regu-
tics
latory agencies as a hazardous substance that can cause serious D3681 TestMethodforChemicalResistanceof“Fiberglass”
medicalissues.Mercury,oritsvapor,hasbeendemonstratedto
(Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a
be hazardous to health and corrosive to materials. Caution Deflected Condition
should be taken when handling mercury and mercury-
D5813 Specification for Cured-In-Place Thermosetting
Resin Sewer Piping Systems
F412 Terminology Relating to Plastic Piping Systems
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic
F1216 Practice for Rehabilitation of Existing Pipelines and
Piping Systems and is the direct responsibility of Subcommittee F17.67 on
Conduits by the Inversion and Curing of a Resin-
Trenchless Plastic Pipeline Technology.
Impregnated Tube
Current edition approved Dec. 1, 2017. Published January 2018. Originally
approved in 2006. Last previous edition approved in 2016 as F2561–16. DOI: F3097 Practice for Installation of an Outside Sewer Service
10.1520/F2561-17.
Cleanout through a Minimally Invasive Small Bore
2
Therehabilitationofasewerservicelateralanditsconnectiontothemainusing
Vacuum Excavation
a one-piece main and lateral cured-in-place liner is covered by patents (LMK
Enterprises, Inc. 1779 Chessie Lane, Ottawa, IL 61350). Interested parties are
invited to submit information regarding the identification of acceptable alternatives
3
to this patented item to the Committee on Standards,ASTM Headquarters, 100 Barr For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Harbor Drive, West Conshohocken, PA 19428-2959. Your comments will receive contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
carefulconsiderationatameetingoftheresponsibletechnicalcommitteewhichmay Standards volume information, refer to the standard’s Document Summary page on
attend. the ASTM
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2561 − 16 F2561 − 17
Standard Practice for
Rehabilitation of a Sewer Service Lateral and Its Connection
to the Main Using a One Piece Main and Lateral Cured-in-
1,2
Place Liner
This standard is issued under the fixed designation F2561; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner
diameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0
cm) and up the lateral a maximum of 150 ft without excavation. The lateral pipe is accessed remotely from the main pipe and from
a lateral cleanout. access point. This will be accomplished by the installation of a resin impregnated one-piece main and lateral
cured-in-place lining (MLCIPL) by means of air or water inflation and inversion. The MLCIPL is pressed against the host pipe
by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous,
one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section
of the main pipe, providing a verifiable non-leaking structural connection and seal.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 There is no similar or equivalent ISO Standard.
1.4 Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious
medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should
be taken when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for
additional information. Users should be aware that selling mercury or mercury-containing products, or both, may be prohibited by
local or national law.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements
involving entering into and working in confined spaces.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
3
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless Plastic
Pipeline Technology.
Current edition approved April 1, 2016Dec. 1, 2017. Published May 2016January 2018. Originally approved in 2006. Last previous edition approved in 20112016 as
F2561.–16. DOI: 10.1520/F2561-16.10.1520/F2561-17.
2
The rehabilitation of a sewer service lateral and its connection to the main using a one-piece main and lateral cured-in-place liner is covered by patents (LMK Enterprises,
Inc. 1779 Chessie Lane, Ottawa, IL 61350). Interested parties are invited to submit information regarding the identification of acceptable alternatives to this patented item
to the Committee on Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. Your comments will receive careful consideration at a
meeting of the responsible technical committee which may attend.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standar
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.