Standard Specification for Reinforced Concrete Low-Head Pressure Pipe

ABSTRACT
This specification covers reinforced concrete low-head pressure pipe. Acceptability of the pipe in all diameters and classes shall be determined by the results of such material tests. The reinforced concrete shall consist of Portland cement, mineral aggregates, and water, in which steel has been embedded in such a manner that the steel and concrete act together. Portland cement shall conform to the requirements specified. Aggregates shall conform to the requirements specified, except that the requirements for grading are waived. Admixtures, except for air-entraining agents, shall not be added to the concrete unless permitted by the owner. Reinforcement shall consist of wire conforming to the requirements prescribed. Steel castings for fittings shall conform to grade 70-36. Steel plates for specials and fittings shall conform to requirements specified. All rubber gaskets shall be extruded or molded and cured in such a manner that any cross section will be dense, homogeneous, and free of porosity, blisters, pitting, and other imperfections. Joints shall utilize steel joint rings, steel bells and concrete spigots, or be formed entirely of concrete. The aggregates shall be graded, proportioned, and thoroughly mixed with the proportions of cementitious material and water that will produce a workable, uniform, homogeneous concrete mixture. Compression tests of cylinders and hydrostatic tests of pipes shall be performed to meet the requirements prescribed.
SCOPE
1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low internal hydrostatic heads generally not exceeding 125 ft.  
1.2 This specification is the inch-pound companion to Specification C361; therefore, no SI equivalents are presented in the specification.Note 1—Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included in specifications for pipe laying.

General Information

Status
Historical
Publication Date
31-Jan-2014
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C361-14 - Standard Specification for Reinforced Concrete Low-Head Pressure Pipe
English language
27 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C361-14 - Standard Specification for Reinforced Concrete Low-Head Pressure Pipe
English language
27 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C361 −14
StandardSpecification for
1
Reinforced Concrete Low-Head Pressure Pipe
This standard is issued under the fixed designation C361; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope A576Specification for Steel Bars, Carbon, Hot-Wrought,
Special Quality
1.1 This specification covers reinforced concrete pipe in-
A615/A615MSpecificationforDeformedandPlainCarbon-
tended to be used for the construction of pressure pipelines
Steel Bars for Concrete Reinforcement
with low internal hydrostatic heads generally not exceeding
A675/A675MSpecification for Steel Bars, Carbon, Hot-
125 ft.
Wrought, Special Quality, Mechanical Properties
1.2 This specification is the inch-pound companion to
A706/A706MSpecification for Low-Alloy Steel Deformed
Specification C361; therefore, no SI equivalents are presented
and Plain Bars for Concrete Reinforcement
in the specification.
A1008/A1008MSpecification for Steel, Sheet, Cold-Rolled,
NOTE 1—Field tests on completed portions of the pipeline are not
Carbon, Structural, High-Strength Low-Alloy, High-
coveredbythisspecificationforthemanufactureofthepipebutshouldbe
Strength Low-Alloy with Improved Formability, Solution
included in specifications for pipe laying.
Hardened, and Bake Hardenable
A1011/A1011MSpecification for Steel, Sheet and Strip,
2. Referenced Documents
Hot-Rolled, Carbon, Structural, High-Strength Low-
2
2.1 ASTM Standards:
Alloy, High-Strength Low-Alloy with Improved
A27/A27MSpecification for Steel Castings, Carbon, for
Formability, and Ultra-High Strength
General Application
C31/C31MPractice for Making and Curing Concrete Test
A36/A36MSpecification for Carbon Structural Steel
Specimens in the Field
A82/A82MSpecification for Steel Wire, Plain, for Concrete
C33Specification for Concrete Aggregates
3
Reinforcement (Withdrawn 2013)
C39/C39MTest Method for Compressive Strength of Cylin-
A185/A185M Specification for Steel Welded Wire
drical Concrete Specimens
3
Reinforcement, Plain, for Concrete (Withdrawn 2013)
C150Specification for Portland Cement
A283/A283MSpecification for Low and Intermediate Ten-
C260Specification for Air-Entraining Admixtures for Con-
sile Strength Carbon Steel Plates
crete
A496/A496MSpecification for Steel Wire, Deformed, for
3 C309Specification for Liquid Membrane-Forming Com-
Concrete Reinforcement (Withdrawn 2013)
pounds for Curing Concrete
A497/A497M Specification for Steel Welded Wire
C497MTest Methods for Concrete Pipe, Manhole Sections,
Reinforcement, Deformed, for Concrete (Withdrawn
3 or Tile (Metric)
2013)
C595Specification for Blended Hydraulic Cements
A575 Specification for Steel Bars, Carbon, Merchant
C618Specification for Coal Fly Ash and Raw or Calcined
Quality, M-Grades
Natural Pozzolan for Use in Concrete
C655 Specification for Reinforced Concrete D-Load
Culvert, Storm Drain, and Sewer Pipe
1
This specification is under the jurisdiction of ASTM Committee C13 on
C822Terminology Relating to Concrete Pipe and Related
ConcretePipeandisthedirectresponsibilityofSubcommitteeC13.04onLowHead
Products
Pressure Pipe.
Current edition approved Feb. 1, 2014. Published February 2014. Originally
C1602/C1602MSpecification for Mixing Water Used in the
approved in 1955. Last previous edition approved in 2012 as C361–12. DOI:
Production of Hydraulic Cement Concrete
10.1520/C0361-14.
2 C1619Specification for Elastomeric Seals for Joining Con-
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
crete Structures
Standards volume information, refer to the standard’s Document Summary page on
D698Test Methods for Laboratory Compaction Character-
the ASTM website.
3
3
istics of Soil Using Standard Effort (12 400 ft-lbf/ft (600
The last approved version of this historical standard is referenced on
3
www.astm.org. kN-m/m ))
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C361−14
D4253Test Methods for Maximum Index Density and Unit 6.2.1.2 Blended Hydraulic Cement—Blended cement shall
Weight of Soils Using a Vibratory Table conform to the requirements of Specification C595 forType IS
D4254Test Methods for Minimum Index Density and Unit portland blast furnace slag cement or Type IP portland pozzo-
Weight of Soils and Calculation of Relative Density lan cement, except that the pozzolan constituent in theType IP
portland pozzolan cement shall not exceed 20% by weig
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C361 − 12 C361 − 14
Standard Specification for
1
Reinforced Concrete Low-Head Pressure Pipe
This standard is issued under the fixed designation C361; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low
internal hydrostatic heads generally not exceeding 125 ft.
1.2 This specification is the inch-pound companion to Specification C361; therefore, no SI equivalents are presented in the
specification.
NOTE 1—Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included
in specifications for pipe laying.
2. Referenced Documents
2
2.1 ASTM Standards:
A27/A27M Specification for Steel Castings, Carbon, for General Application
A36/A36M Specification for Carbon Structural Steel
3
A82/A82M Specification for Steel Wire, Plain, for Concrete Reinforcement (Withdrawn 2013)
3
A185/A185M Specification for Steel Welded Wire Reinforcement, Plain, for Concrete (Withdrawn 2013)
A283/A283M Specification for Low and Intermediate Tensile Strength Carbon Steel Plates
3
A496/A496M Specification for Steel Wire, Deformed, for Concrete Reinforcement (Withdrawn 2013)
3
A497/A497M Specification for Steel Welded Wire Reinforcement, Deformed, for Concrete (Withdrawn 2013)
A575 Specification for Steel Bars, Carbon, Merchant Quality, M-Grades
A576 Specification for Steel Bars, Carbon, Hot-Wrought, Special Quality
A615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
A675/A675M Specification for Steel Bars, Carbon, Hot-Wrought, Special Quality, Mechanical Properties
A706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A1008/A1008M Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength
Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
A1011/A1011M Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-
Strength Low-Alloy with Improved Formability, and Ultra-High Strength
C31/C31M Practice for Making and Curing Concrete Test Specimens in the Field
C33 Specification for Concrete Aggregates
C39/C39M Test Method for Compressive Strength of Cylindrical Concrete Specimens
C150 Specification for Portland Cement
C260 Specification for Air-Entraining Admixtures for Concrete
C309 Specification for Liquid Membrane-Forming Compounds for Curing Concrete
C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile (Metric)
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
1
This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.04 on Low Head Pressure
Pipe.
Current edition approved Nov. 1, 2012Feb. 1, 2014. Published December 2012February 2014. Originally approved in 1955. Last previous edition approved in 20112012
as C361 – 11.C361 – 12. DOI: 10.1520/C0361-12.10.1520/C0361-14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
Withdrawn.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C361 − 14
C655 Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe
C822 Terminology Relating to Concrete Pipe and Related Products
C1602/C1602M Specification for Mixing Water Used in the Production of Hydraulic Cement Concrete
C1619 Specification for Elastomeric Seals for Joining Concrete Structures
3 3
D698 Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12 400 ft-lbf/ft (600 kN-m/m ))
D4253 Test Methods for Maximum Index Density and Unit Weight of Soils Using a Vibratory
...

Questions, Comments and Discussion