ASTM E2316-14
(Test Method)Standard Test Method for Determination of Particles Resulting from the Attrition of Granular Pesticides
Standard Test Method for Determination of Particles Resulting from the Attrition of Granular Pesticides
SIGNIFICANCE AND USE
5.1 This test method is designed specifically for granular pesticide formulations.
5.2 This test method helps provide information on health hazards likely to arise from exposures by the inhalation route. It can be of use in selecting dose levels for chronic studies and for establishing safety criteria for human exposure.
5.3 The amount of fines determined by this method is a measure of potential inhalation and respiration toxicity because the hazards of inhaled solid substances are influenced by physical factors such as particle size.
SCOPE
1.1 This test method is used to determine the amount and particle size distribution curve of particles with diameter 106 micrometers or smaller resulting from the attrition of granular pesticides.
1.2 The values stated in SI units are to be regarded as standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 8.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2316 − 14
Standard Test Method for
Determination of Particles Resulting from the Attrition of
1
Granular Pesticides
This standard is issued under the fixed designation E2316; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.2 micron and µm— synonyms for micrometer.
1.1 This test method is used to determine the amount and
4. Summary of Test Method
particle size distribution curve of particles with diameter 106
micrometers or smaller resulting from the attrition of granular 4.1 The initial weight of a test sample of granular pesticide
is determined. The sample is then air jet sieved using 106
pesticides.
micron openings to remove the inherent fines. The fines-free
1.2 The values stated in SI units are to be regarded as
granules are then combined with glass beads in a glass jar, the
standard.
lid is placed on the jar, and the jar is placed on a roller system
1.3 This standard does not purport to address all of the
with a drive bed capable of rotating the jar at a known rpm.
safety concerns, if any, associated with its use. It is the
After rolling for a specified time period, the jar is removed
responsibility of the user of this standard to establish appro-
from the rollers and the contents of the jar are poured through
priate safety and health practices and determine the applica-
a sieve sized to remove the glass beads. The sample minus the
bility of regulatory limitations prior to use. For specific hazard
glassbeadsisagainairjetsievedusing106micronopeningsto
statement, see Section 8.
remove the fines attrited during the rolling of the jar. The total
of particles smaller than 106 microns for the test sample is the
2. Referenced Documents
inherent fines plus the attrited fines. The particle size distribu-
2
2.1 ASTM Standards:
tion curve of the combined inherent and attrited fines is
E11 Specification for Woven Wire Test Sieve Cloth and Test
determined by laser light diffraction using CIPAC Test Method
Sieves
MT 187.
E725 Test Method for Sampling Granular Carriers and
Granular Pesticides
5. Significance and Use
2.2 CIPAC Standard:
3 5.1 This test method is designed specifically for granular
CIPAC Test Method MT 187
pesticide formulations.
3. Terminology
5.2 This test method helps provide information on health
3.1 Definitions: hazards likely to arise from exposures by the inhalation route.
It can be of use in selecting dose levels for chronic studies and
3.1.1 fines—a synonym for particles with diameter of 106
micrometers or smaller. for establishing safety criteria for human exposure.
5.3 The amount of fines determined by this method is a
1
measureofpotentialinhalationandrespirationtoxicitybecause
This test method is under the jurisdiction of ASTM Committee E35 on
Pesticides, Antimicrobials, and Alternative Control Agentsand is the direct respon-
the hazards of inhaled solid substances are influenced by
sibility of Subcommittee E35.22 on Pesticide Formulations and Delivery Systems.
physical factors such as particle size.
Current edition approved Oct. 1, 2014. Published December 2014. Originally
approvedin2003.Lastpreviouseditionapprovedin2014asE2316–03(2014).DOI:
10.1520/E2316-14. 6. Apparatus
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
6.1 Roller System, two or more rollers with a drive bed,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on capable of rotating the specified glass jar at 75 6 15 rpm.
the ASTM website.
3 6.2 Glass Jar,withlid,capacity~500mL,outerdiameter~8
The size distribution of the particles with sieve diameter less than 106 µm is
determined by laser light diffraction using CIPAC Test Method MT 187. cm, height ~15 cm.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E2316 − 14
6.3 Glass Beads, diameter 4.0 6 0.2 mm, bulk density ~1.5 11.3 Weigh the cyclone collection jar to the nearest 0.01 g
g/cc. and record as J1. Attach the jar to the apparatus.
6.4 Micron Air Jet Sieve, with GAZ 125 cyclone fines 11.4 Measure and record the relative humidity of the air that
will come in contact with the granules. In the absence of
collector or Alpine Air Jet Sieve, with GAZ 125 cyclone fines
4
collector, or equivalent. humidity controlled air, the air of concern will be the air of the
room in which the tests are performed.
6.5 Sieves, U.S. standard series conforming to Specification
11.5 Place the 106 µm sieve in the air jet manifold
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2316 − 03 (Reapproved 2014) E2316 − 14
Standard Test Method for
Determination of Particles Resulting from the Attrition of
1
Granular Pesticides
This standard is issued under the fixed designation E2316; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
6
1.1 This test method is used to determine the amount and particle size distribution curve of particles with diameter 10106
micrometers or smaller resulting from the attrition of granular pesticides.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. For specific hazard statement, see Section 8.
2. Referenced Documents
2
2.1 ASTM Standards:
E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves
E725 Test Method for Sampling Granular Carriers and Granular Pesticides
2.2 CIPAC Standard:
3
CIPAC Test Method MT 187
3. Terminology
3.1 Definitions:
6
3.1.1 fines—a synonym for particles with diameter of 10106 micrometers or smaller.
3.1.2 micron and μm— synonyms for micrometer.
4. Summary of Test Method
6
4.1 The initial weight of a test sample of granular pesticide is determined. The sample is then air jet sieved using 10106 micron
openings to remove the inherent fines. The fines-free granules are then combined with glass beads in a glass jar, the lid is placed
on the jar, and the jar is placed on a roller system with a drive bed capable of rotating the jar at a known rpm. After rolling for
a specified time period, the jar is removed from the rollers and the contents of the jar are poured through a sieve sized to remove
6
micron openings to remove the fines attrited
the glass beads. The sample minus the glass beads is again air jet sieved using 10106
6
during the rolling of the jar. The total of particles smaller than 10106 microns for the test sample is the inherent fines plus the
attrited fines. The particle size distribution curve of the combined inherent and attrited fines is determined by laser light diffraction
using CIPAC Test Method MT 187.
5. Significance and Use
5.1 This test method is designed specifically for granular pesticide formulations.
5.2 This test method helps provide information on health hazards likely to arise from exposures by the inhalation route. It can
be of use in selecting dose levels for chronic studies and for establishing safety criteria for human exposure.
1
This test method is under the jurisdiction of ASTM Committee E35 on Pesticides, Antimicrobials, and Alternative Control Agentsand is the direct responsibility of
Subcommittee E35.22 on Pesticide Formulations and Delivery Systems.
Current edition approved Aug. 1, 2014Oct. 1, 2014. Published November 2014December 2014. Originally approved in 2003. Last previous edition approved in 20092014
as E2316–03(2009).E2316–03(2014). DOI: 10.1520/E2316-03R14.10.1520/E2316-14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
6
3
The size distribution of the particles with sieve diameter less than 10106 μm is determined by laser light diffraction using CIPAC Test Method MT 187.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E2316 − 14
5.3 The amount of fines determined by this method is a measure of potential inhalation and respiration toxicity because the
hazards of inhaled solid substances are influenced by physical factors such as particle size.
6. Apparatus
6.1 Roller System, two or more rollers with a drive bed, capable of rotating the specified glass jar at 75 6 15 rpm.
6.2 Glass Jar, with lid, capacity ~500 mL, outer diameter ~8 cm, height ~15 cm.
6.3 Glass Beads, diameter 4.0 6 0.2 mm, bulk density ~1.5 g/cc.
4
6.4 Micron Air Jet Sieve, with GAZ 125 cyclone fines collector or Alpine Air Jet Sieve, with GAZ 125 c
...
Questions, Comments and Discussion