Standard Test Methods for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers

SIGNIFICANCE AND USE
The emissivity of a specimen can cause surface temperature measurement errors. Two test methods are provided for measuring and compensating for this error source.
These test methods can be used in the field or laboratory, using commonly available materials.
These test methods can be used with any infrared radiometers that have the required computer capabilities.
SCOPE
1.1 These test methods cover procedures for measuring and compensating for emissivity when measuring the surface temperature of a specimen with an infrared imaging radiometer.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 These test methods may involve use of equipment and materials in the presence of heated or electrically-energized equipment, or both.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2005
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1933-99a(2005)e1 - Standard Test Methods for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:E1933–99a (Reapproved 2005)
Standard Test Methods for
Measuring and Compensating for Emissivity Using Infrared
Imaging Radiometers
This standard is issued under the fixed designation E1933; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
´ NOTE—Footnote 2 was editorially changed to include the publication supplier’s new address in March 2005.
1. Scope 4. Summary of Test Method
1.1 These test methods cover procedures for measuring and 4.1 Twotestmethodsaregivenformeasuringthe emissivity
compensating for emissivity when measuring the surface of a specimen surface, the contact thermometer method and the
temperature of a specimen with an infrared imaging radiom- non-contact thermometer method.
eter. 4.2 A test method is also given for compensating for the
1.2 The values stated in SI units are to be regarded as the error produced by emissivity using the computer built into an
standard. infrared imaging radiometer.
1.3 These test methods may involve use of equipment and
5. Significance and Use
materials in the presence of heated or electrically-energized
equipment, or both. 5.1 The emissivity of a specimen can cause surface tem-
perature measurement errors. Two test methods are provided
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the for measuring and compensating for this error source.
5.2 Thesetestmethodscanbeusedinthefieldorlaboratory,
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- using commonly available materials.
5.3 These test methods can be used with any infrared
bility of regulatory limitations prior to use.
radiometers that have the required computer capabilities.
2. Referenced Documents
3 6. Interferences
2.1 ASTM Standards:
6.1 Contact Thermometer Method—Contact thermometers
E1316 Terminology for Nondestructive Examinations
can act as heat sinks and change the temperature of the
3. Terminology
specimen.
3.1 Definitions of Terms Specific to This Standard: 6.2 Noncontact Thermometer Method:
3.1.1 reflected temperature—the temperature of the energy 6.2.1 The use of surface-modifying materials can change
incident upon and reflected from the measurement surface of the heat transfer properties and temperature of the specimen.
the specimen. Any such errors can be minimized by applying surface-
3.1.2 surface-modifying material—any tape, spray, paint or modifying materials to the smallest area that satisfies the
the like that is used to change the emissivity of the specimen measurement accuracy requirements of the radiometer and
surface. infrared thermographer.
3.2 See also Terminology E1316. 6.2.2 Before the surface-modifying material is applied to an
area of the specimen adjacent to the area where the emissivity
is to be measured (as directed in 8.2.4), errors can be
These test methods are under the jurisdiction of ASTM Committee E07 on
minimized by viewing the imager display to ensure that both
Nondestructive Testing and is the direct responsibility of Subcommittee E07.10 on
areas have the same temperature.
Emerging NDT Methods.
Current edition approved March 1, 2005. Published May 2005. Originally
6.2.3 When removing a surface-modifying material, as di-
approved in 1997. Last previous edition approved in 1999 as E1933 - 99a. DOI:
rected in 8.2.7, errors can be minimized by ensuring that the
10.1520/E1933-99AR05E01.
surface is returned to its original condition.
These test methods are adapted from the Guideline for Measuring and
Compensating for Reflected Temperature, Emittance and Transmittance developed 6.3 Both test methods require the specimen to be at a
by the Infraspection Institute, 425 Ellis Street, Burlington, NJ 08016.
temperature that is at least 10°C warmer or cooler than the
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ambient temperature. Potential errors can be minimized by
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
ensuring the stability of the temperature difference between the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
´1
E1933–99a (2005)
specimenandtheambienttemperatureduringthetest.Also,the 8.1.5 Without moving the imager, adjust its computer’s
emissivity measurement accuracy can be increased by increas- emissivity control until the imager’s computer indicates the
ing this temperature difference.
same temperature recorded in 8.1.4. The indicated emissivity
6.4 The emissivity of a specimen may be specific to the
value is the measured emissivity of the specimen, at this
temperature of the specimen and the spectral waveband of the temperature and spectral waveband.
infrared imaging radiometer used to make the measurement.
8.1.6 Repeat procedures 8.1.1 through 8.1.5 a minimum of
Therefore, the temperature of the specimen and the spectral
three times and average the emissivity values to yield an
waveband of the radiometer should be noted along with the
average emissivity.
measured emissivity value.
8.2 Noncontact Thermometer Method:
6.5 These test methods are valid only for specimens that are
8.2.1 Place the infrared imaging radiometer on the tripod or
opaque in the waveband of the infrared imaging radiometer.
support device at the desired location and distance from the
6.6 As the emissivity of a specimen decr
...