ABSTRACT
This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring members designed to receive screw-attached gypsum panel products. Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. Each element of the assembly, that is, the studs, runners, rigid furring channels, tie wires, hanger wires, grid suspension systems (consisting of the main beam, cross furring members, and rod and flat hangers) shall be manufactured in the specified dimensions. Specified installation procedures for the metal framing, which includes the runners, studs, chase wall partitions, rigid furring channels, wall furring-bracket systems, and soffits, are detailed thoroughly. Installation requirements for the suspended and furred ceilings, including the main runners, flat hangers and inserts, wood constructions, furring members, rigid furring channels, and grid suspension systems, are discussed methodically as well.
SCOPE
1.1 This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring members designed to receive screw-attached gypsum panel products. The steel framing and furring members covered in this specification are limited to those complying with Specification C645.
1.2 Details of construction for a specific assembly to achieve the required fire resistance, sound or acoustic rating shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing, sound or acoustic laboratories.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C754 −11
StandardSpecification for
Installation of Steel Framing Members to Receive Screw-
1
Attached Gypsum Panel Products
This standard is issued under the fixed designation C754; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C645Specification for Nonstructural Steel Framing Mem-
bers
1.1 This specification covers the minimum requirements for
C840SpecificationforApplicationandFinishingofGypsum
the installation of interior nonstructural steel framing and
Board
furring members designed to receive screw-attached gypsum
3
2.2 AISI Standard:
panel products. The steel framing and furring members cov-
AISI COSPCode of Standard Practice for Cold-Formed
ered in this specification are limited to those complying with
Steel Structural Framing - 2006 Edition
Specification C645.
4
2.3 ICC-ES Document
1.2 Details of construction for a specific assembly to
ICC-ES-AC86 Acceptance Criteria for Steel Studs and
achieve the required fire resistance, sound or acoustic rating
Gypsum-Board Interior Nonload-Bearing Walls—
shallbeobtainedfromreportsoffire-resistancetests,engineer-
Complete Construction—AC86—Approved July 1995
ing evaluations, or listings from recognized fire testing, sound
(Editorially revised September 2005) (Formerly ICBO
or acoustic laboratories.
AC86 dated July 1995)
1.3 The values stated in inch-pound units are to be regarded
3. Terminology
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only 3.1 Definitions—Terms shall be as defined in Terminology
and are not considered standard. C11.
3.2 Definitions of Terms Specific to This Standard:
2. Referenced Documents
3.2.1 channel, n—the material described in 4.3 to which
2
2.1 ASTM Standards:
furring members are attached.
A641/A641MSpecification for Zinc–Coated (Galvanized)
3.2.2 cross furring, n—furring member attached perpen-
Carbon Steel Wire
dicular to main runners or framing members.
A653/A653MSpecification for Steel Sheet, Zinc-Coated
3.2.3 cross furring member, n—a member installed perpen-
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed)
dicularlytothemainbeamsdesignedtoreceivescrewattached
by the Hot-Dip Process
gypsum panel products.
A1008/A1008MSpecification for Steel, Sheet, Cold-Rolled,
Carbon, Structural, High-Strength Low-Alloy, High- 3.2.4 direct furring, n—furringmembersattacheddirectlyto
Strength Low-Alloy with Improved Formability, Solution the structural members of the building.
Hardened, and Bake Hardenable
3.2.5 framing member, n—metal studs, runners (track), and
C11Terminology Relating to Gypsum and Related Building
rigid furring channels designed to receive screw attached
Materials and Systems
gypsum panel products.
3.2.6 furred ceiling, n—a ceiling in which the rigid furring
1
channels and studs are attached directly to the structural
This specification is under the jurisdiction of ASTM Committee C11 on
GypsumandRelatedBuildingMaterialsandSystemsandisthedirectresponsibility
members of the building.
ofSubcommitteeC11.03onSpecificationsfortheApplicationofGypsumandOther
3.2.7 furring, v—preparingawallorceilingwithframingor
Products in Assemblies.
Current edition approved Aug. 1, 2011. Published August 2011. Originally
furring members to provide a level surface or airspace.
approved in 1974. Last previous edition approved in 2009 as C754–09a. DOI:
10.1520/C0754-11.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from American Iron and Steel Institute (AISI), 1140 Connecticut
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Ave., NW, Suite 705, Washington, DC 20036, http://www.steel.org.
4
Standards volume information, refer to the standard’s Document Summary page on Available from ICC Evaluation Services, Inc., 5360 Workman Mill Road,
the ASTM website. Whittier, CA 90601, www.icc-es.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C754−11
3.2.8 furring member, n—metal studs, rigid furring 4.4.2 Cross Furring Members—Formed from cold-rolled
channels, or channels used either as direct furring or as cross steel, designed to permit screw attachment of gypsum panel
furring. products, and formed with an end configuration that permits
mechanical interlock with the indexed slots of the main beam.
3.2.9 grid suspension system, n—ac
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C754–09a Designation: C754 – 11
Standard Specification for
Installation of Steel Framing Members to Receive Screw-
1
Attached Gypsum Panel Products
This standard is issued under the fixed designation C754; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring
members designed to receive screw-attached gypsum panel products. The steel framing and furring members covered in this
specification are limited to those complying with Specification C645.
1.2 Details of construction for a specific assembly to achieve the required fire resistance, sound or acoustic rating shall be
obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing, sound or acoustic
laboratories.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
2. Referenced Documents
2
2.1 ASTM Standards:
A641/A641M Specification for ZincCoated (Galvanized) Carbon Steel Wire
A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the
Hot-Dip Process
A1008/A1008M Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength
Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
C11 Terminology Relating to Gypsum and Related Building Materials and Systems
C645 Specification for Nonstructural Steel Framing Members
C840 Specification for Application and Finishing of Gypsum Board
2.2 ICC-ES Document
3
2.2 AISI Standard:
AISI COSP Code of Standard Practice for Cold-Formed Steel Structural Framing - 2006 Edition
4
2.3 ICC-ES Document
ICC-ES-AC86 Acceptance Criteria for Steel Studs and Gypsum-Board Interior Nonload-Bearing Walls—Complete
Construction—AC86—Approved July 1995 (Editorially revised September 2005) (Formerly ICBO AC86 dated July 1995)
3. Terminology
3.1 Definitions—Terms shall be as defined in Terminology C11.
3.2 Descriptions of Terms Specific to This Standard:
3.2.1 channel, n—the material described in 4.3 to which furring members are attached.
3.2.2 cross furring, n—furring member attached perpendicular to main runners or framing members.
3.2.3 cross furring member, n—a member installed perpendicularly to the main beams designed to receive screw attached
gypsum panel products.
3.2.4 direct furring, n—furring members attached directly to the structural members of the building.
1
This specification is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of
Subcommittee C11.03 on Specifications for the Application of Gypsum and Other Products in Assemblies.
Current edition approved Nov.Aug. 1, 2009.2011. Published December 2009.August 2011. Originally approved in 1974. Last previous edition approved in 2009 as
C754 – 09a. DOI: 10.1520/C0754-09a.10.1520/C0754-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from ICC Evaluation Services, Inc., 5360 Workman Mill Road, Whittier, CA 90601, www.icc-es.org.
3
Available from American Iron and Steel Institute (AISI), 1140 Connecticut Ave., NW, Suite 705, Washington, DC 20036, http://www.steel.org.
4
Available from ICC Evaluation Services, Inc., 5360 Workman Mill Road, Whittier, CA 90601, www.icc-es.org.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C754 – 11
3.2.5 framing member, n—metal studs, runners (track), and rigid furring channels designed to receive screw attached gypsum
panel products.
3.2.6 furred ceiling, n—a ceiling in which the rigid furring channels and studs are attached directly to the structural me
...
Questions, Comments and Discussion